Overview
- Preloaded with 24 OM4 ribbon pigtails (250um fiber)
- MPO male interface for high-density, secure terminations
- Removable bevel for improved cable routing and installation ease
- Supports OM4 multimode fiber with low insertion loss
- UL 94 V-0 rated flame-retardant housing for safety and durability
Specifications
Connection Type | MPO Male |
Material | Poly |
Series | Opticom |
Package Dimensions (L x W x H) | 9.2 IN x 4.5 IN x 2.6 IN |
Package Dimensions (L x W x H) | 23.368 cm x 11.43 cm x 6.604 cm |
Package Weight (Imperial) | 0.3500 L |
Package Weight (Metric) | 0.1588 kg |

FCS29O-48-MPR
This Opticom MPO Male Splice Cassette is Preloaded with 48 OS2 Ribbon Pigtails (250um), Opt IL. Cassettes have removable bevelFrequently Asked Questions
How many fibers does the FCS2ZO-24-MPR cassette support?
The FCS2ZO-24-MPR cassette supports a fiber count of 24.
What fiber type is used in the FCS2ZO-24-MPR cassette?
The FCS2ZO-24-MPR cassette uses OM4 multimode fiber.
What connector type does the FCS2ZO-24-MPR cassette use?
The FCS2ZO-24-MPR cassette uses MPO-12 connectors.
What type of pigtail is included with FCS2ZO-24-MPR?
The FCS2ZO-24-MPR cassette includes ribbon pigtails.
What is the operating temperature range for the cassette?
The operating temperature range for the cassette is 0°C to 70°C (32°F to 158°F).
What is the storage temperature range for the cassette?
The storage and shipping temperature range for the cassette is -40°C to 75°C (-40°F to 167°F).
What is the insertion loss for the FCS2ZO-24-MPR?
The MPO:OM4 Optimized insertion loss for this cassette is 0.35dB plus splice loss.
What is the return loss for the multimode fibers?
The return loss per multimode fiber is greater than 26dB.
What is the FCS2ZO-24-MPR product?
The FCS2ZO-24-MPR is an Opticom fiber optic splice cassette designed for quick and easy field splicing in high-density applications.
What accessories are included with the splice cassette?
The cassette includes 1-meter pigtails, splice protection sleeves, cable ties, and a splice holder for field splicing.
How to Install and Splice the FCS2ZO-24-MPR Opticom MPO Splice Cassette
This guide provides step-by-step instructions for installing and splicing incoming fiber cables to the FCS2ZO-24-MPR Opticom MPO Splice Cassette, including preparing the cassette and securing it into a compatible panel or enclosure.
Estimated time: 1h 30m
Tools needed:
#2 Phillips screwdriver, Scissors, Fiber optic fusion splicer, Fiber cleaver, Fiber strippers
Supplies needed:
Pan-Ty Cable Ties (PLT1M-M20WIP), 1/4" Phillips Screws (for Aramid yarn strain relief), Ribbon Splice Sleeves, Isopropyl alcohol, Lint-free wipes
- Prepare the Cassette and Observe Safety Warnings
WARNING: Unmated connectors may emit invisible laser radiation; maintain dust caps on unmated connectors. CAUTION: Fiber optic cable is sensitive to excessive pulling, bending, and crushing forces. Push down the Cover Removal Latch in the rear of the cassette and slide the Cover back until the 4 tabs clear to remove it. If equipped and necessary for splicing on the base, squeeze the two tabs on the Splice Tray inward to release and remove the Splice Tray from the Base. Carefully remove fiber ends from any pigtails coiled in the Splice Tray and set them aside.
- Prepare and Secure Incoming Fiber Cable to the Base
Strip the incoming fiber cable outer jacket approximately 20 inches (0.5 meters). Secure the incoming fiber cable to the Base using two provided Pan-Ty Cable Ties. Optionally, secure the incoming fiber cable's Aramid yarn to the Base using the provided 1/4" Phillips screw(s).
- Splice Fibers on the Base
Expose all fiber ends for splicing. Slide a ribbon splice sleeve onto either the pigtail or field fiber. Strip off approximately 1.375 inches (35mm) of coating from each fiber and clean with isopropyl alcohol. Cleave the fiber so that 0.400 inches (10mm) of bare fiber extends past the fiber coating. Do not clean the bare fiber after it has been cleaved, and do not let it come into contact with any surfaces. Splice all fibers according to your splicer manufacturer's best practice instructions and heat the splice sleeve(s). Route the spliced fibers into the cassette, ensuring they are located under the Base fiber retention tabs. Secure the splice sleeves into the Ribbon Splice Sleeve Holders in the Base.
- Replace Splice Tray and Splice Remaining Fibers (if applicable)
Replace the Splice Tray into the Base, ensuring no fibers previously spliced onto the base are protruding above the Base Fiber Retention Tabs. An audible 'CLICK' should be heard when the Splice Tray is pushed back into the Base. If splicing additional fibers on the Splice Tray (as indicated for 24-fiber ribbon cassettes like FCS2ZO-24-MPR), secure additional incoming fiber cables directly onto the Splice Tray if needed, then repeat the stripping, cleaning, cleaving, splicing, and routing steps for these fibers on the Splice Tray. Secure the splice sleeves into the Splice Tray's Ribbon Splice Sleeve Holders.
- Re-install the Cassette Cover
Re-install the cassette Cover by reversing the removal steps. Push the Cover forward until the Cover Removal Latch 'clicks' into place, ensuring it is securely attached to the Base.
- Install the Cassette into a Panel or Enclosure
Install the cassette into a compatible panel or enclosure. For front installation, snap the two grommets on the cassette directly into the holes on the front of the panel or enclosure. For rear installation, temporarily remove the Bezel by pushing the Bezel latch inward to release it from the cassette. Install the cassette through the rear of the panel or enclosure, then re-attach the Bezel and secure the grommets to the front.
Frequently Asked Questions about Panduit
What environmental ratings do Panduit products have?
Panduit products feature comprehensive environmental ratings across multiple standards, including UL 508A Type 1, 2, 3, 4, 4X, 12, and 13; CSA Type 1, 2, 3, 4, 4X, 12, and 13; and NEMA Type 1, 2, 3, 4, 4X, 12, and 13. They meet IEC 60529 IP66 rating, providing robust protection against dust, water, and corrosion in both indoor and outdoor environments, with operating temperatures ranging from -40°C to 130°C.
What certifications and standards do Panduit products comply with?
Panduit products are certified to multiple critical industry standards, including UL (Underwriters Laboratories) in the USA and Canada, CSA (Canadian Standard Association), EN IEC 61386, LVD 2006/G5/EC, and ARRA standards. Our products meet rigorous certifications for electrical safety, environmental compliance (WEEE and RoHS), and are designed to perform in extreme temperatures ranging from -55°C to 105°C, making them suitable for demanding industrial environments.
What industries and applications are Panduit products used for?
Panduit products are engineered for critical applications across multiple industries, including commercial construction, food and beverage, oil and gas, renewable energy, transportation, and safety-critical environments. Their solutions span electrical infrastructure, wire management, cable ties, power connectors, and safety systems designed to withstand extreme conditions like high vibration, temperature variations, UV exposure, and corrosive agents. Key industries include solar and wind energy, aerospace, heavy trucking, military, commercial transportation, and industrial manufacturing.
What are the main product lines offered by Panduit?
Panduit offers a comprehensive range of electrical infrastructure products including power connectors, cable ties, grounding connectors, identification products, safety solutions, terminals, cable cleats, wiring duct, and cable tie accessories. These products are engineered for industrial environments across multiple sectors like commercial construction, food and beverage, oil and gas, renewable energy, transportation, and safety applications.
What are the key features of Panduit products?
Panduit products are engineered for robust performance in heavy-duty industrial environments, featuring a comprehensive range of solutions including cable ties, power connectors, terminals, and identification products. Key features include proven quality performance, subject matter expertise, and customer-driven innovation across multiple industrial sectors such as commercial construction, food and beverage, oil and gas, renewable energy, transportation, and safety applications. The product line is designed to maximize productivity, reliability, and safety while meeting stringent industry standards.
What is Panduit's warranty policy?
Panduit provides a comprehensive Limited Product Warranty that can be fully reviewed on their official website at www.panduit.com/warranty. All Panduit products are subject to the terms, conditions, and limitations of this current warranty. Customers are advised to review the specific warranty details for their particular product, as Panduit requires buyers to determine product suitability for their intended use and assumes all associated risks.
What technical support does Panduit offer?
Panduit offers comprehensive technical support through their dedicated customer service team, accessible via phone at 1-800-777-3300. They provide expert assistance for their full range of industrial infrastructure products, including cable ties, power connectors, terminals, and identification solutions. Customers can also access additional technical resources and product information through their website at www.panduit.com.
What accessories are available for Panduit products?
Panduit offers a wide range of accessories across multiple product lines, including cable ties, cable tie accessories, cable tie tools, identification products, cable cleats, grounding connectors, and VeriSafe accessories like the VeriSafe Network Module and Insulation Piercing Connectors. For a comprehensive view of all available accessories, customers are recommended to visit www.panduit.com for the full product catalog.
How are Panduit products typically installed?
Panduit products are engineered for comprehensive installation across industrial environments, utilizing specialized tools and techniques for precise mounting. Installation methods vary by product line - from cable ties and power connectors to terminals and identification solutions - but all are designed for robust performance in heavy-duty settings. Technicians typically use Panduit's dedicated installation tools and follow manufacturer guidelines available at www.panduit.com to ensure proper fitting and maximum infrastructure reliability.