- Preloaded with 48 OM4 ribbon pigtails (250um fiber diameter)
- MPO male connector interface for direct trunk cable connection
- Removable bevel design for enhanced installation flexibility
- Optimized for OM4 multimode fiber performance (10G/40G/100G applications)
- Manufactured in the US for reliable quality and compliance
Specifications
Package Dimensions (L x W x H) | 9.2 IN x 4.5 IN x 2.6 IN |
Package Dimensions (L x W x H) | 23.368 cm x 11.43 cm x 6.604 cm |
Package Weight (Imperial) | 0.3500 L |
Package Weight (Metric) | 0.1588 kg |

FCS2ZO-24-LSP
Opticom LC Splice Cassette is Preloaded with 24 OM4 Discrete Pigtails(250Um)and splice kit, and has Optimized IL. Cassettes have removable bevel.Frequently Asked Questions
What are Opticom fiber optic splice cassettes used for?
Opticom fiber optic splice cassettes facilitate quick and easy splicing of bare fiber leads in high-density applications.
What fiber counts are available for these cassettes?
Opticom splice cassettes are available with fiber counts of 12, 24, or 48.
What fiber types do these cassettes support?
The cassettes support singlemode OS1/2 9/125μm and multimode OM4 50/125μm fiber types.
What front connectivity options are offered?
Front connectivity options include LC Duplex, SC Duplex, LC/APC Duplex, SC/APC Duplex, and MPO-12.
What pigtail types are available for the splice cassettes?
The splice cassettes are available with either 250μm discrete or flat ribbon pigtails, supporting up to 48 fibers.
What accessories are included with the splice cassettes?
The cassettes include 1-meter pigtails, splice protection sleeves (individual and ribbon), cable ties, and a splice holder.
What enclosures are compatible with Opticom splice cassettes?
Opticom splice cassettes are compatible with all Opticom Enclosures (FRME*, FCE*) and Opticom patch panels.
What is the insertion loss for OM4 MPO optimized cassettes?
The insertion loss for OM4 MPO optimized cassettes is 0.35dB plus splice loss.
What are the return loss specifications for these cassettes?
The return loss is greater than 26dB for multimode and greater than 55dB for singlemode per fiber.
What is the connector durability rating?
The connectors have a durability rating of 500 mating cycles, meeting TIA/EIA-568C.3 A.4.9.
How to Install the FCS2ZO-48-MPR Opticom Splice Cassette
A comprehensive guide for preparing, splicing, and installing the FCS2ZO-48-MPR Opticom Splice Cassette, which features 4 OM4 ribbon pigtails, into a compatible panel or enclosure.
Estimated time: 2h
Tools needed:
#2 Phillips screwdriver, Scissors, Fiber optic fusion splicer, Fiber cleaver, Fiber strippers, Lint-free wipes
Supplies needed:
Pan-Ty Cable Ties, 1/4" Phillips Screws (for Aramid yarn), Ribbon Splice Sleeves, Isopropyl alcohol, Dust caps, Incoming OM4 fiber cable
- Review Safety and Prepare Cassette for Splicing
WARNING: Unmated connectors may emit invisible laser radiation. Maintain dust caps on unmated connectors. CAUTION: Fiber optic cable is sensitive to excessive pulling, bending, and crushing forces. Consult the manufacturer’s cable specification sheet. Push down the Cover Removal Latch in the rear of the cassette and slide the Cover back until the 4 tabs clear, then remove the Cover. Squeeze the two tabs on the Splice Tray inward and/or pull the Base wall outward to release and remove the Splice Tray from the Base. Carefully remove any pre-coiled fiber pigtails and set them aside.
- Prepare and Splice Incoming Fiber Cable on the Base
Strip the incoming OM4 fiber cable outer jacket 20 inches (0.5 meters). Secure the incoming fiber cable to the Base using two provided Pan-Ty Cable Ties; cut off excess. (Optional) Secure the Aramid yarn to the Base using provided 1/4" Phillips screws. Expose all fiber ends for splicing. Slide a ribbon splice sleeve onto either the pigtail or field fiber. Strip approximately 1.375 inches (35mm) of coating, clean with isopropyl alcohol. Cleave the fiber so 0.400 inches (10mm) of bare fiber extends past coating. Splice ribbon fibers and heat sleeve. Route spliced fibers under Base retention tabs. Secure ribbon splice sleeves into the two ribbon holders in the Base.
- Replace Splice Tray and Splice Remaining Fiber Cable
Replace the Splice Tray into the Base, ensuring no fibers protrude above Base Fiber Retention Tabs. Push until an audible 'CLICK' is heard. If splicing additional incoming fiber cables or completing a 48-fiber splice, repeat the preparation and splicing steps for the Splice Tray. Secure incoming fiber cables to the Splice Tray (if applicable). Route spliced fibers under Splice Tray retention tabs and secure ribbon splice sleeves into the Splice Tray's holders.
- Re-install Cover and Install Cassette into Panel/Enclosure
After all splicing is complete, re-install the Cassette Cover by pushing it forward until the Cover Removal Latch 'clicks' into place. Install the Opticom Splice Cassette directly onto the front of a compatible panel or enclosure by snapping the two grommets into the designated holes. Alternatively, for rear installation, push the Bezel latch inward to release and temporarily remove the Removable Cassette Bezel. Install the cassette through the rear, then re-attach the Bezel and secure the grommets to the front.
Frequently Asked Questions about Panduit
What environmental ratings do Panduit products have?
Panduit products feature comprehensive environmental ratings across multiple standards, including UL 508A Type 1, 2, 3, 4, 4X, 12, and 13; CSA Type 1, 2, 3, 4, 4X, 12, and 13; and NEMA Type 1, 2, 3, 4, 4X, 12, and 13. They meet IEC 60529 IP66 rating, providing robust protection against dust, water, and corrosion in both indoor and outdoor environments, with operating temperatures ranging from -40°C to 130°C.
What certifications and standards do Panduit products comply with?
Panduit products are certified to multiple critical industry standards, including UL (Underwriters Laboratories) in the USA and Canada, CSA (Canadian Standard Association), EN IEC 61386, LVD 2006/G5/EC, and ARRA standards. Our products meet rigorous certifications for electrical safety, environmental compliance (WEEE and RoHS), and are designed to perform in extreme temperatures ranging from -55°C to 105°C, making them suitable for demanding industrial environments.
What industries and applications are Panduit products used for?
Panduit products are engineered for critical applications across multiple industries, including commercial construction, food and beverage, oil and gas, renewable energy, transportation, and safety-critical environments. Their solutions span electrical infrastructure, wire management, cable ties, power connectors, and safety systems designed to withstand extreme conditions like high vibration, temperature variations, UV exposure, and corrosive agents. Key industries include solar and wind energy, aerospace, heavy trucking, military, commercial transportation, and industrial manufacturing.
What are the main product lines offered by Panduit?
Panduit offers a comprehensive range of electrical infrastructure products including power connectors, cable ties, grounding connectors, identification products, safety solutions, terminals, cable cleats, wiring duct, and cable tie accessories. These products are engineered for industrial environments across multiple sectors like commercial construction, food and beverage, oil and gas, renewable energy, transportation, and safety applications.
What are the key features of Panduit products?
Panduit products are engineered for robust performance in heavy-duty industrial environments, featuring a comprehensive range of solutions including cable ties, power connectors, terminals, and identification products. Key features include proven quality performance, subject matter expertise, and customer-driven innovation across multiple industrial sectors such as commercial construction, food and beverage, oil and gas, renewable energy, transportation, and safety applications. The product line is designed to maximize productivity, reliability, and safety while meeting stringent industry standards.
What is Panduit's warranty policy?
Panduit provides a comprehensive Limited Product Warranty that can be fully reviewed on their official website at www.panduit.com/warranty. All Panduit products are subject to the terms, conditions, and limitations of this current warranty. Customers are advised to review the specific warranty details for their particular product, as Panduit requires buyers to determine product suitability for their intended use and assumes all associated risks.
What technical support does Panduit offer?
Panduit offers comprehensive technical support through their dedicated customer service team, accessible via phone at 1-800-777-3300. They provide expert assistance for their full range of industrial infrastructure products, including cable ties, power connectors, terminals, and identification solutions. Customers can also access additional technical resources and product information through their website at www.panduit.com.
What accessories are available for Panduit products?
Panduit offers a wide range of accessories across multiple product lines, including cable ties, cable tie accessories, cable tie tools, identification products, cable cleats, grounding connectors, and VeriSafe accessories like the VeriSafe Network Module and Insulation Piercing Connectors. For a comprehensive view of all available accessories, customers are recommended to visit www.panduit.com for the full product catalog.
How are Panduit products typically installed?
Panduit products are engineered for comprehensive installation across industrial environments, utilizing specialized tools and techniques for precise mounting. Installation methods vary by product line - from cable ties and power connectors to terminals and identification solutions - but all are designed for robust performance in heavy-duty settings. Technicians typically use Panduit's dedicated installation tools and follow manufacturer guidelines available at www.panduit.com to ensure proper fitting and maximum infrastructure reliability.