ABB - Installation Products R2T15M4-N2440 - Outdoor, Ranger2 Termination, 15kV, Cable Type Tape Shield/Wire Shield/Unishield, Insulation Range 1.30 to 2.10 inch (33-53mm). Connector Type Copper 2-Hole Spade #2-1250 kcmil. Conductor Size 1250 Compressed/Stranded.

ABB Installation Products R2T15M4-N2440 Outdoor, Ranger2 Termination, 15kV, Cable Type Tape Shield/Wire Shield/Unishield…

UPC: 075114328487


Documents & Media
Installation InstructionsSpecification SheetManufacturer Product Website

Contact for Pricing

Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.

Overview

The ABB Ranger2 Termination, SKU R2T15M4-N2440, is designed for outdoor 15kV applications. This termination system is compatible with tape shield, wire shield, and Unishield cable types. It accommodates insulation diameters ranging from 1.30 to 2.10 inches (33-53mm), providing a secure fit for a variety of cable constructions. The integrated connector is a copper 2-hole spade, suitable for conductors up to 1250 kcmil, whether compressed or stranded. This product ensures reliable electrical connections in outdoor environments. Its robust construction and specific design parameters address the requirements for medium-voltage cable termination. The Ranger2 system offers a straightforward installation process for electricians and utility professionals working with 15kV distribution systems. Key specifications include: * **Voltage Rating:** 15kV * **Cable Insulation Diameter Range:** 1.30 - 2.10 inches (33-53mm) * **Compatible Cable Shielding:** Tape Shield, Wire Shield, Unishield * **Connector Type:** Copper 2-Hole Spade * **Conductor Size Compatibility:** Up to 1250 kcmil (Compressed/Stranded)
  • Outdoor 15kV termination system
  • Compatible with Tape Shield, Wire Shield, and Unishield cable types
  • Accommodates insulation diameters from 1.30 to 2.10 inches (33-53mm)
  • Features a copper 2-hole spade connector
  • Suitable for 1250 kcmil compressed/stranded conductors

Specifications

Application
Cable Termination, Outdoor Application, 15kV
Cable Type
Copper Tape Shielded Wire
Color
Gray
Conductor Size
1250 kcmil
Connection Type
Copper 2-Hole Spade #2-1250 kcmil
Earthing
Products Includes Their Own Grounding System
Material
Copper
Mounting
Product Need to have Cable Holder (not included)
Mounting Type
Outdoor
Number Of Terminals
(1) Single Phase
Series
Ranger2
Size
1.30 to 2.10 inch (33-53mm)
Special Features
Silicone Rubber Housing. Lightweight, Compact Design. Pull-Down Tabs for Easy Installation. Thick Wall Construction
Standard
IEEE 48
Type
Cable Termination - Outdoor - Ranger2
Voltage Rating
15 kV
Package Dimensions (L x W x H)
0.01 IN x 0.01 IN x 0.01 IN
Package Dimensions (L x W x H)
0.0254 cm x 0.0254 cm x 0.0254 cm
Package Weight (Imperial)
1.0000 L
Package Weight (Metric)
0.4540 kg
Indoor Ranger2 Cable Termination. 15kV, Cable Type - Tape Shield/Wire Shield/UniShield. Insulation Range - 1.30 inch - 2.10 inch. Copper 2-Hole Spade #2-1250 kcmil, Conductor 1250 Stranded/Compressed

R2IT15M4-N2440

Indoor Ranger2 Cable Termination. 15kV, Cable Type - Tape Shield/Wire Shield/UniShield. Insulation Range - 1.30 inch - 2.10 inch. Copper 2-Hole Spade #2-1250 kcmil, Conductor 1250 Stranded/Compressed
Ranger 2 Terminator, Outdoor, 15kV, Concentric Neutral/Jacketed Concentric Neutral Cable Type, Insulation Range .84 -1.38 inch (21-35mm) Connector Type - Copper 2-Hole Spade #2-1250 kcmil. 350 Stranded/Compressed or 400 Compact/Solid.

R2T15J2N2300

Ranger 2 Terminator, Outdoor, 15kV, Concentric Neutral/Jacketed Concentric Neutral Cable Type, Insulation Range .84 -1.38 inch (21-35mm) Connector Type - Copper 2-Hole Spade #2-1250 kcmil. 350 Stranded/Compressed or 400 Compact/Solid.
15kV, Ranger2 Cable Termination, Outdoor, Cable Type - Concentric Neutral/Jacketed Concentric Neutral, Insulation Range - .84-1.38 inch (21-35mm), Connector Type - N2 - Copper 2-Hole spade #2-1250 kcmil, Conductor Code 270 - 4/0 Strandeed/Compressed or 250 Compact/Solid.

R2T15J2-N2270

15kV, Ranger2 Cable Termination, Outdoor, Cable Type - Concentric Neutral/Jacketed Concentric Neutral, Insulation Range - .84-1.38 inch (21-35mm), Connector Type - N2 - Copper 2-Hole spade #2-1250 kcmil, Conductor Code 270 - 4/0 Strandeed/Compressed or 250 Compact/Solid.
15kV, Outdoor, Ranger2 Cable Termination, Cable Type - Concentric Neutral/Jacket Concentric Neutral. Insulation Range 0.64 to 1.12 iches, Connector Type H0 - Aluminum 1-Hole Spade #2-500kcmil. Conductor Size - 250 - 2/0 Stranded/Compressed or 3/0 Solid/Compact.

R2T15J1-H0250

15kV, Outdoor, Ranger2 Cable Termination, Cable Type - Concentric Neutral/Jacket Concentric Neutral. Insulation Range 0.64 to 1.12 iches, Connector Type H0 - Aluminum 1-Hole Spade #2-500kcmil. Conductor Size - 250 - 2/0 Stranded/Compressed or 3/0 Solid/Compact.
Outdoor Ranger2 Cable Termination, 15kV, Concentric neutral/Jacketed Concentric Neutral Cable Type, Insulation Range .84-1.38 inch (21-mm), Connector Type - Aluminum 2-Hole Spade #2-1250 kcmil, Conductor Code 210 - #2 Compact/Solid.

R2T15J2-N0210

Outdoor Ranger2 Cable Termination, 15kV, Concentric neutral/Jacketed Concentric Neutral Cable Type, Insulation Range .84-1.38 inch (21-mm), Connector Type - Aluminum 2-Hole Spade #2-1250 kcmil, Conductor Code 210 - #2 Compact/Solid.
Outdoor Ranger2 Cable Termination, 15kV, Concentric neutral/Jacketed Concentric Neutral Cable Type, Insulation Range .84-1.38 inch (21-35mm), Connector Type - Copper 2-Hole Spade #2-1250 kcmil, Conductor Code 310 - 400 Stranded/Compressed or 500 Compact/Solid.

R2T15J2-N2310

Outdoor Ranger2 Cable Termination, 15kV, Concentric neutral/Jacketed Concentric Neutral Cable Type, Insulation Range .84-1.38 inch (21-35mm), Connector Type - Copper 2-Hole Spade #2-1250 kcmil, Conductor Code 310 - 400 Stranded/Compressed or 500 Compact/Solid.
15 kv, Cable Terminator Ranger2, Outdoor, Cable Type - Tape Shield/Wire Shield/UniShield, Insulation Range 4 - 1.30 inch to 2.10 inch (33 mm to 53 mm), Connector Type N0 - Alunimum 2-Hole Spade #2-1250 kcmil, Conductor Code 410 - Compressed 1000, Cable Mounting Bracket B3 - Material Stainless Steel - Size - 1.45 inch to 1.95 inch (37mm - 50mm)

R2T15M4-N0410-B3

15 kv, Cable Terminator Ranger2, Outdoor, Cable Type - Tape Shield/Wire Shield/UniShield, Insulation Range 4 - 1.30 inch to 2.10 inch (33 mm to 53 mm), Connector Type N0 - Alunimum 2-Hole Spade #2-1250 kcmil, Conductor Code 410 - Compressed 1000, Cable Mounting Bracket B3 - Material Stainless Steel - Size - 1.45 inch to 1.95 inch (37mm - 50mm)
25/28kV, Ranger2 Cable Termination. Outdoor. Cable Type - Concentric Neutral/Jacketed Concentric Neutral. Insulation Range 1.30-2.10 inch. Connector Type Aluminum 2 Hole Spade #2-1250kcmil. Conductor Size 750kcmil Stranded/compressed 900kcmil Solid/Compact. Stainless Steel Cable Mounting Bracket 1.80-2.40 inches

R2T28J4-N0380-B4

25/28kV, Ranger2 Cable Termination. Outdoor. Cable Type - Concentric Neutral/Jacketed Concentric Neutral. Insulation Range 1.30-2.10 inch. Connector Type Aluminum 2 Hole Spade #2-1250kcmil. Conductor Size 750kcmil Stranded/compressed 900kcmil Solid/Compact. Stainless Steel Cable Mounting Bracket 1.80-2.40 inches

Frequently Asked Questions

Where can I find installation instructions for the R2T15?

Installation instructions are IS-1134 for R2T15J, IS-1135 for R2T15M, and IS-1136 for R2T15L.

What is the IEEE classification for the R2T15 outdoor termination?

The R2T15 outdoor termination has an IEEE Classification of Class 1A.

What is the power system frequency range for this termination?

The R2T15 termination is designed for power system frequencies ranging from 48 to 62 Hz.

What is the ambient temperature range for the R2T15?

The R2T15 termination operates within an ambient temperature range of -22 to +149 °F (-30 to +65 °C).

What is the maximum operating altitude for the R2T15?

The R2T15 termination can be used at a maximum altitude of 3300 feet (1005 m).

What is the voltage rating of the R2T15 termination?

The R2T15 termination has a voltage rating of 15 kV.

What cable sizes are compatible with the R2T termination?

The R2T termination accommodates cable sizes from #2 AWG through 1250 kcmil.

What cable insulation diameters does the R2T termination cover?

The R2T termination covers cable insulation diameters from 0.64 inches (16 mm) to 2.10 inches (53 mm).

What is the power system frequency range for this termination?

The R2T15 termination is designed for power system frequencies ranging from 48 to 62 Hz.

What cable insulation diameters does the R2T termination cover?

The R2T termination covers cable insulation diameters from 0.64 inches (16 mm) to 2.10 inches (53 mm).

How to Install the R2T15M4 Silicone Rubber Termination for Tape Shielded Cables

This guide provides detailed instructions for installing the 15kV Ranger 2 Shrink fit Silicone Rubber Termination (R2T15M4) on tape shielded cables, covering cable preparation, ground braid installation, lug connection, and termination body placement.

Estimated time: 1h

Tools needed:

Wire strippers, Measuring tape, Crimping tool, Approved solvent, Aluminum oxide abrasive (120 grit or finer, optional), Vinyl tape

Supplies needed:

R2T15M4 Silicone Rubber Termination Kit (includes Lubricant, Gray Silicone Rubber Electrical Tape, Constant Force Spring, Preformed Ground Braid, Sealing Mastic, Copper Foil Tape, Gloves), Terminal lug/connector, Scotch® No. 13 semi-conductive rubber tape (if applicable for cloth or paper semi-con insulation shield)

  1. De-energize and Prepare Cable

    DANGER: Ensure all apparatus is de-energized before beginning installation. This product should only be installed by competent personnel trained in high voltage electrical equipment safety practices. Verify the cable size fits within the insulation range specified in the Termination Selection Chart. Train the cable into position and cut it to the required length. Prepare the cable by removing the jacket, tape shield, and insulation according to the dimensions provided in the documentation, allowing for terminal lug depth and aluminum lug growth allowance. Secure the edge of the tape shield with a single wrap of the supplied copper foil tape to prevent unrolling.

  2. Install Ground Braid

    Carefully wrap one band of mastic around the cable jacket, 1/4 inch (6mm) from the jacket end, using 50% stretch. Position the mastic to serve as a marker for the termination and cut it flush without overlap. Position the preformed ground braid with its short tail over the tape shield and the solder block centered over the mastic strip. Secure the ground braid to the cable jacket with vinyl tape and press the solder block into the mastic. Apply a second mastic band over the solder block and the first mastic, maintaining the 1/4 inch (6mm) dimension, and cut flush. Wrap two half-lapped layers of vinyl tape around the mastic seal. Wrap the ground braid around the cable tape shield one complete wrap, trim any excess, and secure it in place with the constant force spring, wrapping the spring in the same direction as the ground braid. Cinch the spring after the final winding and secure it with two wraps of vinyl tape. If the cable has a cloth or paper semi-conductive shield, overwrap it with one half-lapped layer of highly stretched semi-conductive rubber tape (e.g., Scotch® No. 13).

  3. Install Lug or Connector

    Check that the termination assembly can fit over the selected lug. If not, clean the insulation and slide the termination onto the cable before installing the lug, but do not remove the core at this time. Position the connector or lug and crimp it according to the manufacturer's directions, ensuring not to crimp the last 3/8 to 1/2 inch of the connector. After crimping, remove any excess oxide inhibitor and all sharp crimp flashings and edges.

  4. Clean Cable Insulation and Lug Barrel

    Wipe the cable insulation with an approved solvent, taking care not to let the solvent touch the semi-conductive insulation shield. If abrasive cleaning is necessary, use only aluminum oxide abrasive (120 grit or finer) on the insulation, not on the semi-conductive insulation shield. Be careful not to reduce the cable insulation diameter below the kit's allowed range.

  5. Install Termination Body

    Create a track-resistant moisture seal between the termination insulator and the lug/connector by wrapping a band of gray silicone rubber electrical tape (from the kit) around the base of the terminal lug. If the barrel diameter is equal to or greater than the cable primary insulation, use no more than 2 layers. If smaller, build up the tape band to equal the insulation diameter. Cover the edge of the semi-conductive insulation shield with a liberal coating of silicone grease to fill the step at the semi-con cut-off. For lower terminations with a fold-down skirt, pull the loose end of the removable core through the top of the termination until the core is flush with the bottom. Slide the termination body onto the cable, aligning it with the forward edge of the mastic seal. Carefully begin to remove the core by unwinding it counter-clockwise, starting with the loose end. Ensure the termination body, not the core, is butted against the leading edge of the mastic seal. Continue removing the core without pushing or pulling on the termination assembly.

  6. Complete Termination Seal and Ground Connection

    Apply a thin film of silicone lubricant to the skirt and mastic seal area, avoiding the skirt tabs. Carefully fold down the skirt over the mastic seal. With the termination installed, complete the lug area moisture seal using the remaining gray silicone rubber electrical tape. Overlap the termination insulator by approximately 1 inch and extend the tape wrapping over a non-crimped region of the lug/connector barrel with a half-lap configuration. Connect the ground braid to the system ground. Finally, confirm that the High-K step does not exceed 1.5 inches.

Frequently Asked Questions about ABB - Installation Products

How are Thomas and Betts products typically installed?

Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.

What accessories are available for Thomas and Betts products?

Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.

What environmental ratings do Thomas and Betts products have?

Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.

What communication protocols do Thomas and Betts products support?

Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.

What are the key features of Thomas and Betts products?

Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.

What are the main product lines offered by Thomas and Betts?

Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.

What technical support does Thomas and Betts offer?

Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.

What industries and applications are Thomas and Betts products used for?

Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.

What certifications and standards do Thomas and Betts products comply with?

Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.

What are the main product lines offered by Ocal?

Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.