Authorized ABB Distributor (Installation Products)
ABB - Installation Products R2T28J4-N0380-B4 - 25/28kV, Ranger2 Cable Termination. Outdoor. Cable Type - Concentric Neutral/Jacketed Concentric Neutral. Insulation Range 1.30-2.10 inch. Connector Type Aluminum 2 Hole Spade #2-1250kcmil. Conductor Size 750kcmil Stranded/compressed 900kcmil Solid/Compact. Stainless Steel Cable Mounting Bracket 1.80-2.40 inches

ABB Installation Products R2T28J4-N0380-B4 25/28kV, Ranger2 Cable Termination. Outdoor. Cable Type - Concentric Neutral/Jacketed…

UPC: 075114344784


Documents & Media
Installation InstructionsSpecification SheetManufacturer Product Website

Contact for Pricing

Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.

Overview

The ABB Ranger2 25/28kV Outdoor Cable Termination (SKU: R2T28J4-N0380-B4) delivers reliable medium-voltage cable termination for outdoor power distribution systems. Designed for Concentric Neutral and Jacketed Concentric Neutral cable types, this termination ensures robust performance in demanding environmental conditions. The product accommodates a wide insulation range from 1.30 to 2.10 inches, providing flexibility for various cable constructions including XLP and EPR types. The termination features a non-tracking silicone housing with superior memory and weathering characteristics, ensuring long-term service reliability. Six sheds provide enhanced creepage and strike distances for outdoor applications. The integrated aluminum 2-hole spade connector supports conductor sizes from #2 AWG to 1250 kcmil, including stranded/compressed 750 kcmil and solid/compact 900 kcmil configurations. A stainless steel cable mounting bracket with an adjustable range of 1.80 to 2.40 inches ensures secure and stable installation. The shrink-fit housing uses common installation procedures and cable preparation dimensions, while field-removable center cores simplify installation in restricted spaces. Optional insulating silicone sleeves are available for increased creepage requirements or wildlife protection. The termination is designed to install in restricted spaces and permits free-hanging applications where required. This product is part of ABB's Installation Products line, engineered for medium-voltage power systems requiring secure connections and environmental resilience in outdoor environments.
  • Accommodates 1.30-2.10" insulation diameter and #2 AWG to 1250 kcmil conductors
  • Non-tracking silicone housing with six sheds for superior creepage and strike distances
  • Stainless steel cable mounting bracket (1.80-2.40" adjustable range)
  • Shrink-fit technology with field-removable center core for simplified installation

Specifications

Application
Cable Termination, Outdoor Application, 28kV
Cable Type
Concentric Neutral Wire
Color
Gray
Conductor Size
750 to 900 kcmil
Earthing
Products Includes Their Own Grounding System
Mounting
Product Need to have Cable Holder (not included)
Number Of Terminals
(1) Single Phase
Special Features
Silicone Rubber Housing. Lightweight, Compact Design. Pull-Down Tabs for Easy Installation. Thick Wall Construction
Standard
IEEE 48
Type
Cable Termination - Outdoor - Ranger2
Voltage Rating
28 kV
Package Dimensions (L x W x H)
0.01 IN x 0.01 IN x 0.01 IN
Package Dimensions (L x W x H)
0.0254 cm x 0.0254 cm x 0.0254 cm
Package Weight (Imperial)
1.0000 L
Package Weight (Metric)
0.4540 kg
Ranger2 Termination. Type - Outdoor, 28kV, Cable Type - Concentric Neutral/Jacketed Concentric Neutral, Insulation Range - 1.30 inch - 2.10 inch, Connector Type - Aluminum 2-Hole Spade #2-1250 kcmil, Conductor Code - 380 -Stranded or Compressed 750 Compact or Solid 900. Cable Mounting Bracket - B3 - Stainless Steel - Size 1.45 inch - 1.95 inch.

R2T28J4-N0380-B3

Ranger2 Termination. Type - Outdoor, 28kV, Cable Type - Concentric Neutral/Jacketed Concentric Neutral, Insulation Range - 1.30 inch - 2.10 inch, Connector Type - Aluminum 2-Hole Spade #2-1250 kcmil, Conductor Code - 380 -Stranded or Compressed 750 Compact or Solid 900. Cable Mounting Bracket - B3 - Stainless Steel - Size 1.45 inch - 1.95 inch.
Outdoor, Ranger2 Termination, 15kV, Cable Type Concentric Neutral/Jacketed Concentric Neutral, Insulation Range .84 to 1.38 inch (21-35mm). Connector Type Aluminum 2-Hole Spade #2-1250 kcmil. Conductor Code 270 - 4/0 Stranded/Compressed or 250 Solid/Compact. Cable Mounting Bracket 1.10-1.50 inch (28-38mm), Plated Mild Steel.

R2T15J2-N0270-B2

Outdoor, Ranger2 Termination, 15kV, Cable Type Concentric Neutral/Jacketed Concentric Neutral, Insulation Range .84 to 1.38 inch (21-35mm). Connector Type Aluminum 2-Hole Spade #2-1250 kcmil. Conductor Code 270 - 4/0 Stranded/Compressed or 250 Solid/Compact. Cable Mounting Bracket 1.10-1.50 inch (28-38mm), Plated Mild Steel.
15kV, Outdoor, Ranger2 Termination with Mounting Bracket, Cable Type - Concentric Neutral/Jacketed Concentric Neutral, Insulation Range - 1.30-2.10 inch (33-53mm), Connector Type N2 - Copper 2-Hoel Spade #2-1250 kcmil. Conductor Code 410 - 1000 kcmil Stranded/Compressed. Cable Mounting Bracket Material - B3 - Stainless Steel - 1.45-1.95 inch (37-50mm).

R2T15J4-N2410-B3

15kV, Outdoor, Ranger2 Termination with Mounting Bracket, Cable Type - Concentric Neutral/Jacketed Concentric Neutral, Insulation Range - 1.30-2.10 inch (33-53mm), Connector Type N2 - Copper 2-Hoel Spade #2-1250 kcmil. Conductor Code 410 - 1000 kcmil Stranded/Compressed. Cable Mounting Bracket Material - B3 - Stainless Steel - 1.45-1.95 inch (37-50mm).
15kV, Ranger2 Cable Termination. Outdoor. Cable Type - Tape Shield/Wire Sheild/Unisheild. Insulation Range .64-1.12 inch. Connector Type Aluminum 1 Hole Spade #2-500kcmil. Conductor Size 4/0 Stranded/compressed 250kcmil Solid/Compact.

R2T15M1H0270

15kV, Ranger2 Cable Termination. Outdoor. Cable Type - Tape Shield/Wire Sheild/Unisheild. Insulation Range .64-1.12 inch. Connector Type Aluminum 1 Hole Spade #2-500kcmil. Conductor Size 4/0 Stranded/compressed 250kcmil Solid/Compact.
Ranger2 Termination. Type - Outdoor, 15kV, Cable Type - Tape Shield/Wire Shield/ Unshield, Insulation Range - .64 inch - 1.12 inch, Connector Type - Universal Aluminum Barrel for AL or CU Condutor with Copper Wire Lead #2-4/0, Conductor Code - 220 -Stranded/Compressed #2 or Compact/Solid #1.

R2T15M1T0220

Ranger2 Termination. Type - Outdoor, 15kV, Cable Type - Tape Shield/Wire Shield/ Unshield, Insulation Range - .64 inch - 1.12 inch, Connector Type - Universal Aluminum Barrel for AL or CU Condutor with Copper Wire Lead #2-4/0, Conductor Code - 220 -Stranded/Compressed #2 or Compact/Solid #1.
Ranger2 Termination for 25/28KV outdoor application, cable insulation diameter 1.30 - 2.10 inches for Concentric Neural and Jacketed Concentric Neutral Cable, includes Aluminum 2-Hole Spade connector for #2-1250 kcmil, Stranded/Compressed 4/0 or Compact/Solid 250, Stainless Steel Mounting Bracket 1.45 inch - 1.95 inch

R2T28J4-N0270-B3

Ranger2 Termination for 25/28KV outdoor application, cable insulation diameter 1.30 - 2.10 inches for Concentric Neural and Jacketed Concentric Neutral Cable, includes Aluminum 2-Hole Spade connector for #2-1250 kcmil, Stranded/Compressed 4/0 or Compact/Solid 250, Stainless Steel Mounting Bracket 1.45 inch - 1.95 inch
15kV, Ranger2 Cable Termination, Indoor, Cable Type - Concentric Neutral/Jacketed Concentric Neutral, Insulation Range - 1.30-2.10 inch (33-53mm), Connector Type - N2 - Copper 2-Hole spade #2-1250 kcmil, Conductor Code 300 - 350 Strandeed/Compressed or 400 Compact/Solid.

R2IT15J4-N2300

15kV, Ranger2 Cable Termination, Indoor, Cable Type - Concentric Neutral/Jacketed Concentric Neutral, Insulation Range - 1.30-2.10 inch (33-53mm), Connector Type - N2 - Copper 2-Hole spade #2-1250 kcmil, Conductor Code 300 - 350 Strandeed/Compressed or 400 Compact/Solid.
Ranger2 Termination. Type - Indoor, 15kV, Cable Type - Tape Shield/Wire Shield/ Unshield, Insulation Range - .64 inch - 1.12 inch, Connector Type - Aluminum 2-Hole Spade #2-1250 kcmil, Conductor Code - 250 -Stranded/Compressed 2/0 or Compact/Solid 3/0.

R2IT15M1-N0250

Ranger2 Termination. Type - Indoor, 15kV, Cable Type - Tape Shield/Wire Shield/ Unshield, Insulation Range - .64 inch - 1.12 inch, Connector Type - Aluminum 2-Hole Spade #2-1250 kcmil, Conductor Code - 250 -Stranded/Compressed 2/0 or Compact/Solid 3/0.

Frequently Asked Questions

What cable types is the ABB Ranger2 termination compatible with?

The ABB Ranger2 25/28kV termination is designed for Concentric Neutral and Jacketed Concentric Neutral cable types.

What is the insulation diameter range for this cable termination?

This termination supports an insulation range of 1.30 to 2.10 inches.

What is the voltage rating of the Ranger2 cable termination?

The Ranger2 cable termination has a voltage rating of 25/28kV.

Does the termination include a mounting bracket?

Yes, it includes a stainless steel cable mounting bracket with an adjustment range of 1.80 to 2.40 inches.

How to Install Ranger 2 Cable Termination (15kV & 28kV)

This guide provides step-by-step instructions for installing the Ranger 2 Cable Termination on concentric and jacketed concentric neutral cables for indoor/outdoor high-voltage applications. Ensure all safety precautions are followed.

Estimated time: 1h 30m

Tools needed:

Wire strippers, Crimping tool, Vinyl tape, Approved solvent, Aluminum oxide abrasive (grit 120 or finer), Gloves

Supplies needed:

Silicone Rubber Termination, Lubricant, Grey Silicone Rubber Tape, Sealing Mastic, Connector or Lug, Binding wire (optional alternative to vinyl tape)

  1. Prepare Cable for Termination

    DANGER: Ensure all apparatus is de-energized before starting. Check that the cable size fits within the kit range. Train the cable into position and cut to the required length, allowing sufficient neutral wire for grounding. Prepare the cable insulation and jacket to the specified dimensions, accounting for the terminal lug depth. Apply one band of sealing mastic around the cable jacket 1/4 inch (6mm) from the jacket end, stretching 50% and cutting flush. Bend neutral wires back over the mastic and secure them to the cable jacket 4-6 inches (100-150mm) from the cut edge using vinyl tape or binding wire. Apply a second mastic band over the neutral wires and the first mastic, cutting flush. Wrap two half-lapped layers of vinyl tape around the mastic seal, maintaining the 1/4 inch (6mm) dimension.

  2. Install Lug or Connector

    If using a lug that will not fit through the termination core, clean the cable insulation and slide the termination body onto the cable before installing the lug; do not remove the core at this time. Position the connector or lug and crimp it according to the manufacturer's directions, ensuring not to crimp the last 1/4 to 3/8 inch of the connector. After crimping, remove any excess oxide inhibitor and sharp crimp flashings.

  3. Clean Cable Insulation and Lug Barrel

    Wipe the cable insulation with an approved solvent, taking care not to allow the solvent to touch the semi-con insulation shield. If abrasive cleaning is necessary, use only aluminum oxide abrasive (grit 120 or finer) on the insulation, not the semi-con shield. Be careful not to reduce the cable insulation diameter below the kit's allowed range.

  4. Install Termination Body and Moisture Seals

    Create a track-resistant moisture seal between the termination insulator and the lug/connector using gray silicone rubber tape from the kit. Wrap a band of silicone tape around the base of the terminal lug, adjusting layers based on barrel diameter. Apply a liberal coating of silicone grease to the edge of the semi-con insulation shield to fill the step. For lower terminations with a fold-down skirt, pull the loose end of the removable core through the top of the termination until it is flush with the bottom. Slide the termination body onto the cable, aligning it with the forward edge of the mastic seal. Carefully remove the core by unwinding it counter-clockwise, ensuring the termination body remains butted against the mastic seal without pushing or pulling the assembly. Apply a thin film of silicone lubricant to the skirt and mastic seal area (avoiding skirt tabs). Carefully fold down the skirt over the mastic seal. Complete the lug area moisture seal using the remaining gray silicone rubber tape, overlapping the termination insulator by approximately 1 inch and extending over a non-crimped region of the lug/connector barrel with a half-lap configuration.

  5. Ground Neutral Wires and Final Check

    Twist the concentric neutral wires together and securely connect them to the system ground. Confirm that the High-K step does not exceed 1.5 inches (38mm) after installation.

Frequently Asked Questions about ABB - Installation Products

How are Thomas and Betts products typically installed?

Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.

What accessories are available for Thomas and Betts products?

Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.

What environmental ratings do Thomas and Betts products have?

Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.

What communication protocols do Thomas and Betts products support?

Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.

What are the key features of Thomas and Betts products?

Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.

What are the main product lines offered by Thomas and Betts?

Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.

What technical support does Thomas and Betts offer?

Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.

What industries and applications are Thomas and Betts products used for?

Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.

What certifications and standards do Thomas and Betts products comply with?

Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.

What are the main product lines offered by Ocal?

Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.