ABB - Installation Products R2T15J2-N2270 - 15kV, Ranger2 Cable Termination, Outdoor, Cable Type - Concentric Neutral/Jacketed Concentric Neutral, Insulation Range - .84-1.38 inch (21-35mm), Connector Type - N2 - Copper 2-Hole spade #2-1250 kcmil, Conductor Code 270 - 4/0 Strandeed/Compressed or 250 Compact/Solid.

ABB Installation Products R2T15J2-N2270 15kV, Ranger2 Cable Termination, Outdoor, Cable Type - Concentric Neutral/Jacketed…

UPC: 075114336291


Documents & Media
Installation InstructionsSpecification SheetManufacturer Product Website

Contact for Pricing

Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.

Overview

The ABB Ranger2 R2T15J2-N2270 is a 15kV outdoor cable termination designed for Concentric Neutral (CN) and Jacketed Concentric Neutral (JCN) medium-voltage power cables. This termination utilizes shrink-fit technology combined with Elastimold’s pull-down jacket seal for reliable field performance in outdoor installations. It is engineered for cables with insulation diameters ranging from 0.84 to 1.38 inches (21-35mm). The R2T15J2-N2270 accommodates conductor sizes from #2 AWG to 1250 kcmil, specifically supporting 4/0 AWG stranded/compressed or 250 kcmil compact/solid conductors. The N2 connector is a 2-hole copper spade, ensuring a secure electrical connection and compatibility with common XLP and EPR cable types and shield constructions. Key features include a non-tracking silicone housing that offers superior memory and weathering characteristics. The shrink-fit housing employs standard installation procedures and cable preparation dimensions. A field-removable center core facilitates easy installation. This 15kV outdoor model features four sheds, enhancing creepage and strike distances for long-term service. The Ranger2 series offers three sizes to cover the full cable range from #2 AWG to 1250 kcmil. Applications include utility, industrial, and commercial power distribution networks. The termination's compact design allows for installation in restricted spaces and supports free-hanging applications. Optional insulating silicone sleeves are available for increased creepage requirements or wildlife protection. Manufacturer: ABB - Installation Products. SKU: R2T15J2-N2270.
  • 15kV outdoor cable termination for Concentric Neutral (CN) and Jacketed Concentric Neutral (JCN) cables.
  • Accommodates insulation diameters from 0.84 to 1.38 inches (21-35mm).
  • Supports conductor sizes #2 AWG through 1250 kcmil, including 4/0 AWG stranded/compressed or 250 kcmil compact/solid.
  • Features a non-tracking silicone housing with four sheds for enhanced creepage and strike distances.
  • N2 connector: 2-hole copper spade for secure electrical connection.
  • Four sheds for enhanced creepage and strike distances
  • Non-tracking silicone housing with superior weathering resistance
  • Lightning impulse withstand: 110kV crest (BIL)
  • Compact design for installation in restricted spaces or free-hanging applications

Specifications

Application
Cable Termination, Outdoor Application, 15kV
Cable Type
Concentric Neutral Wire
Color
Gray
Conductor Size
4/0 AWG , 250 kcmil
Connection Type
Concentric Neutral/Jacketed Concentric Neutral
Earthing
Products Includes Their Own Grounding System
Mounting
Product Need to have Cable Holder (not included)
Mounting Type
Outdoor
Number Of Terminals
(1) Single Phase
Series
Ranger2
Size
0.84-1.38 inch (21-35mm)
Special Features
Silicone Rubber Housing. Lightweight, Compact Design. Pull-Down Tabs for Easy Installation. Thick Wall Construction
Standard
IEEE 48
Type
Cable Termination - Outdoor - Ranger2
Voltage Rating
15 kV
Package Dimensions (L x W x H)
0.01 IN x 0.01 IN x 0.01 IN
Package Dimensions (L x W x H)
0.0254 cm x 0.0254 cm x 0.0254 cm
Package Weight (Imperial)
1.0000 L
Package Weight (Metric)
0.4540 kg
Ranger2 Termination for 15KV outdoor application, cable insulation diameter .84 - 1.38 inches for Concentric Neural and Jacketed Concentric Neutral Cable. Aluminum 2 Hole Spade #2-1250kcmil, Stranded or Compressed 4/0 /Compact or Solid 250.

R2T15J2-N0270

Ranger2 Termination for 15KV outdoor application, cable insulation diameter .84 - 1.38 inches for Concentric Neural and Jacketed Concentric Neutral Cable. Aluminum 2 Hole Spade #2-1250kcmil, Stranded or Compressed 4/0 /Compact or Solid 250.
15kV, Outdoor, Ranger2 Cable Termination, Cable Type - Concentric Neutral/Jacket Concentric Neutral. Insulation Range 0.64 to 1.12 iches, Connector Type H0 - Aluminum 1-Hole Spade #2-500kcmil. Conductor Size - 250 - 2/0 Stranded/Compressed or 3/0 Solid/Compact.

R2T15J1-H0250

15kV, Outdoor, Ranger2 Cable Termination, Cable Type - Concentric Neutral/Jacket Concentric Neutral. Insulation Range 0.64 to 1.12 iches, Connector Type H0 - Aluminum 1-Hole Spade #2-500kcmil. Conductor Size - 250 - 2/0 Stranded/Compressed or 3/0 Solid/Compact.
Outdoor Ranger2 Cable Termination, 15kV, Concentric neutral/Jacketed Concentric Neutral Cable Type, Insulation Range .84-1.38 inch (21-mm), Connector Type - Aluminum 2-Hole Spade #2-1250 kcmil, Conductor Code 210 - #2 Compact/Solid.

R2T15J2-N0210

Outdoor Ranger2 Cable Termination, 15kV, Concentric neutral/Jacketed Concentric Neutral Cable Type, Insulation Range .84-1.38 inch (21-mm), Connector Type - Aluminum 2-Hole Spade #2-1250 kcmil, Conductor Code 210 - #2 Compact/Solid.
Outdoor Ranger2 Cable Termination, 15kV, Concentric neutral/Jacketed Concentric Neutral Cable Type, Insulation Range .84-1.38 inch (21-35mm), Connector Type - Copper 2-Hole Spade #2-1250 kcmil, Conductor Code 310 - 400 Stranded/Compressed or 500 Compact/Solid.

R2T15J2-N2310

Outdoor Ranger2 Cable Termination, 15kV, Concentric neutral/Jacketed Concentric Neutral Cable Type, Insulation Range .84-1.38 inch (21-35mm), Connector Type - Copper 2-Hole Spade #2-1250 kcmil, Conductor Code 310 - 400 Stranded/Compressed or 500 Compact/Solid.
15 kv, Cable Terminator Ranger2, Outdoor, Cable Type - Tape Shield/Wire Shield/UniShield, Insulation Range 4 - 1.30 inch to 2.10 inch (33 mm to 53 mm), Connector Type N0 - Alunimum 2-Hole Spade #2-1250 kcmil, Conductor Code 410 - Compressed 1000, Cable Mounting Bracket B3 - Material Stainless Steel - Size - 1.45 inch to 1.95 inch (37mm - 50mm)

R2T15M4-N0410-B3

15 kv, Cable Terminator Ranger2, Outdoor, Cable Type - Tape Shield/Wire Shield/UniShield, Insulation Range 4 - 1.30 inch to 2.10 inch (33 mm to 53 mm), Connector Type N0 - Alunimum 2-Hole Spade #2-1250 kcmil, Conductor Code 410 - Compressed 1000, Cable Mounting Bracket B3 - Material Stainless Steel - Size - 1.45 inch to 1.95 inch (37mm - 50mm)
25/28kV, Ranger2 Cable Termination. Outdoor. Cable Type - Concentric Neutral/Jacketed Concentric Neutral. Insulation Range 1.30-2.10 inch. Connector Type Aluminum 2 Hole Spade #2-1250kcmil. Conductor Size 750kcmil Stranded/compressed 900kcmil Solid/Compact. Stainless Steel Cable Mounting Bracket 1.80-2.40 inches

R2T28J4-N0380-B4

25/28kV, Ranger2 Cable Termination. Outdoor. Cable Type - Concentric Neutral/Jacketed Concentric Neutral. Insulation Range 1.30-2.10 inch. Connector Type Aluminum 2 Hole Spade #2-1250kcmil. Conductor Size 750kcmil Stranded/compressed 900kcmil Solid/Compact. Stainless Steel Cable Mounting Bracket 1.80-2.40 inches
Outdoor, Ranger2 Termination, 15kV, Cable Type Concentric Neutral/Jacketed Concentric Neutral, Insulation Range .84 to 1.38 inch (21-35mm). Connector Type Aluminum 2-Hole Spade #2-1250 kcmil. Conductor Code 270 - 4/0 Stranded/Compressed or 250 Solid/Compact. Cable Mounting Bracket 1.10-1.50 inch (28-38mm), Plated Mild Steel.

R2T15J2-N0270-B2

Outdoor, Ranger2 Termination, 15kV, Cable Type Concentric Neutral/Jacketed Concentric Neutral, Insulation Range .84 to 1.38 inch (21-35mm). Connector Type Aluminum 2-Hole Spade #2-1250 kcmil. Conductor Code 270 - 4/0 Stranded/Compressed or 250 Solid/Compact. Cable Mounting Bracket 1.10-1.50 inch (28-38mm), Plated Mild Steel.
15kV, Outdoor, Ranger2 Termination with Mounting Bracket, Cable Type - Concentric Neutral/Jacketed Concentric Neutral, Insulation Range - 1.30-2.10 inch (33-53mm), Connector Type N2 - Copper 2-Hoel Spade #2-1250 kcmil. Conductor Code 410 - 1000 kcmil Stranded/Compressed. Cable Mounting Bracket Material - B3 - Stainless Steel - 1.45-1.95 inch (37-50mm).

R2T15J4-N2410-B3

15kV, Outdoor, Ranger2 Termination with Mounting Bracket, Cable Type - Concentric Neutral/Jacketed Concentric Neutral, Insulation Range - 1.30-2.10 inch (33-53mm), Connector Type N2 - Copper 2-Hoel Spade #2-1250 kcmil. Conductor Code 410 - 1000 kcmil Stranded/Compressed. Cable Mounting Bracket Material - B3 - Stainless Steel - 1.45-1.95 inch (37-50mm).

Frequently Asked Questions

Where can I find installation instructions for the R2T15?

Installation instructions are IS-1134 for R2T15J, IS-1135 for R2T15M, and IS-1136 for R2T15L.

What is the voltage rating of this termination?

The R2T15 Ranger2 Cable Termination has a voltage rating of 15 kV.

What cable insulation diameters does it accommodate?

It covers cable insulation diameters from 0.64 inches (16 mm) to 2.10 inches (53 mm).

What AWG cable sizes are compatible with this termination?

The termination accommodates cable sizes from #2 AWG through 1250 kcmil.

What types of cables are compatible?

Units accommodate popular XLP and EPR cable types and shield constructions.

What is the operating temperature range for the R2T15?

The ambient temperature range for operation is -22 to +149 °F (-30 to +65 °C).

What is the maximum altitude for installation?

The maximum altitude range for installation is 3300 feet (1005 m).

What is the IEEE classification for this outdoor termination?

The IEEE classification for this outdoor termination is Class 1A.

Are there optional connectors available for the R2T15?

Optional connectors include copper stem, one-hole, and two-hole spade connectors.

What is the power system frequency range?

The power system frequency range for this termination is 48 to 62 Hz.

How to Install the Ranger 2 Cable Termination (15kV & 28kV)

This guide provides step-by-step instructions for installing the 15kV and 28kV Ranger 2 Cable Termination on concentric and jacketed concentric neutral cables for indoor/outdoor applications.

Estimated time: 1h 30m

Tools needed:

Wire strippers, Crimping tool, Vinyl tape, Binding wire, Approved solvent, Aluminum oxide abrasive (grit 120 or finer), Gloves

Supplies needed:

Silicone Rubber Termination, Lubricant, Grey Silicone Rubber Tape, Sealing Mastic, Terminal lug or connector, Silicone grease, Cable Support Bracket (optional), System ground connection

  1. Ensure Safety and Verify Cable Compatibility

    DANGER: All apparatus must be de-energized during installation or removal. This product should be installed only by competent personnel trained in high voltage safety practices. Failure to follow instructions will result in serious injury. First, check that the cable size fits within the kit range as shown in the Termination Selection Chart. Train the cable into position and cut to the length required for installation, allowing sufficient neutral wire length for grounding connection. Prepare the cable using the dimensions shown in the instructions, ensuring to allow for the depth of the terminal lug and additional exposed conductor distance for growth during crimping of aluminum lugs.

  2. Apply Mastic and Secure Neutral Wires

    Using 50% stretch, carefully wrap one band of sealing mastic around the cable jacket 1/4" (6mm) from the jacket end. Position mastic carefully as it serves as a marker for positioning the terminator; cut mastic flush without overlap. Bend neutral wires back over and press into the sealing mastic, then secure them to the cable jacket 4-6" (100-150mm) from the cut edge using vinyl tape or binding wire. Apply a second mastic band over the neutral wires and previously applied mastic, using 50% stretch, and cut flush without overlap. Wrap two half-lapped layers of vinyl tape around the mastic seal, carefully maintaining the 1/4" (6mm) dimension.

  3. Install and Crimp the Lug or Connector

    If the chosen lug will not fit through the termination core, clean the insulation and slide the termination onto the cable before installing the lug (do not remove the core at this time). Position the connector or lug and crimp it according to its specific directions. Do not crimp the last 1/4" to 3/8" of the connector. After crimping, remove any excess oxide inhibitor and sharp crimp flashings.

  4. Clean Cable Insulation and Lug Barrel

    Wipe the cable insulation with an approved solvent. Do not allow the solvent to touch the semi-con insulation shield. If abrasive must be used, apply it only on the insulation, not on the semi-con insulation shield. Use only aluminum oxide abrasive, grit 120 or finer. Be careful not to reduce the cable insulation diameter below that allowed by the kit.

  5. Install the Termination Body

    Wrap a band of gray silicone rubber tape around the base of the terminal lug to create a track-resistant moisture seal. If the barrel diameter is smaller than the cable primary insulation, use tape to form the band equal to the insulation diameter. Cover the edge of the semi-con insulation shield with a liberal coating of silicone grease to fill the step. If it's a lower termination with a fold-down skirt, pull the loose end of the removable core through the top until it's flush with the bottom. Slide the termination body onto the cable, aligning it with the forward edge of the mastic seal. Carefully remove the core by unwinding it counter-clockwise, ensuring the termination body is butted up to the mastic seal.

  6. Complete Termination Sealing and Grounding

    Apply a thin film of silicone lubricant to the skirt and mastic seal area, avoiding the skirt tabs. Carefully fold down the skirt over the mastic seal. Complete the lug area moisture seal using the remaining gray silicone rubber tape, overlapping the termination insulator by approximately 1" and extending over a non-crimped region of the lug/connector barrel with a half-lap configuration. Twist the concentric neutral wires together and connect them securely to the system ground. Finally, confirm that the High-K step does not exceed 1.5 inches.

Frequently Asked Questions about ABB - Installation Products

How are Thomas and Betts products typically installed?

Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.

What accessories are available for Thomas and Betts products?

Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.

What environmental ratings do Thomas and Betts products have?

Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.

What communication protocols do Thomas and Betts products support?

Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.

What are the key features of Thomas and Betts products?

Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.

What are the main product lines offered by Thomas and Betts?

Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.

What technical support does Thomas and Betts offer?

Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.

What industries and applications are Thomas and Betts products used for?

Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.

What certifications and standards do Thomas and Betts products comply with?

Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.

What are the main product lines offered by Ocal?

Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.