ABB - Installation Products R2T15J2-N2310 - Outdoor Ranger2 Cable Termination, 15kV, Concentric neutral/Jacketed Concentric Neutral Cable Type, Insulation Range .84-1.38 inch (21-35mm), Connector Type - Copper 2-Hole Spade #2-1250 kcmil, Conductor Code 310 - 400 Stranded/Compressed or 500 Compact/Solid.

ABB Installation Products R2T15J2-N2310 Outdoor Ranger2 Cable Termination, 15kV, Concentric neutral/Jacketed Concentric Neutral…

UPC: 075114333979


Documents & Media
Installation InstructionsSpecification SheetManufacturer Product Website

Contact for Pricing

Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.

Overview

The ABB Ranger2 Outdoor Cable Termination (SKU: R2T15J2-N2310) is engineered for reliable 15kV outdoor power distribution applications. This termination is specifically designed for Concentric neutral and Jacketed Concentric Neutral cable types, accommodating insulation diameters ranging from 0.84 to 1.38 inches (21-35mm). The integrated copper 2-hole spade connector is sized for #2-1250 kcmil conductors, ensuring a secure and robust electrical connection. It is compatible with conductor sizes including 400 Stranded/Compressed or 500 Compact/Solid, identified by Conductor Code 310. The Ranger2 series offers a straightforward and dependable solution for terminating medium-voltage cables in outdoor environments. Key specifications include: * **Voltage Rating:** 15 kV * **Cable Type Compatibility:** Concentric neutral / Jacketed Concentric Neutral * **Insulation Diameter Range:** 0.84 - 1.38 inches (21 - 35mm) * **Connector Type:** Copper 2-Hole Spade * **Connector Size:** #2 - 1250 kcmil * **Conductor Size Compatibility:** 400 Stranded/Compressed or 500 Compact/Solid (Conductor Code 310) * **Mounting:** Outdoor * **Series:** Ranger2 This termination provides a critical interface for power transmission and distribution networks, ensuring safe and efficient energy flow. Its robust construction and specific material composition (copper connector) are suited for the environmental challenges of outdoor installations. The 2-hole spade design offers ample surface area for secure bolting to switchgear, transformers, or other distribution equipment, minimizing resistance and potential failure points. The Ranger2 series from ABB Installation Products is a proven choice for utility and industrial sectors requiring dependable cable terminations.
  • 15 kV voltage rating for medium-voltage distribution.
  • Designed for Concentric neutral/Jacketed Concentric Neutral cable types.
  • Accommodates insulation diameters from 0.84 to 1.38 inches (21-35mm).
  • Copper 2-hole spade connector for #2-1250 kcmil conductors.
  • Compatible with 400 Stranded/Compressed or 500 Compact/Solid conductors.

Specifications

Application
Cable Termination, Outdoor Application, 15kV
Cable Type
Concentric Neutral Wire
Color
Gray
Conductor Size
400 to 500 kcmil
Earthing
Products Includes Their Own Grounding System
Mounting
Product Need to have Cable Holder (not included)
Number Of Terminals
(1) Single Phase
Special Features
Silicone Rubber Housing. Lightweight, Compact Design. Pull-Down Tabs for Easy Installation. Thick Wall Construction
Standard
IEEE 48
Type
Cable Termination - Outdoor - Ranger2
Voltage Rating
15 kV
Package Dimensions (L x W x H)
0.01 IN x 0.01 IN x 0.01 IN
Package Dimensions (L x W x H)
0.0254 cm x 0.0254 cm x 0.0254 cm
Package Weight (Imperial)
1.0000 L
Package Weight (Metric)
0.4540 kg
Ranger2 Termination. Type - Outdoor, 15kV, Cable Type - Tape Shield/Wire Shield/ Unshield, Insulation Range - .84 inch - 1.38 inch, Connector Type - Copper 2-Hole Spade #2-1250 kcmil, Conductor Code - 310 -Stranded or Compressed 400 Compact or Solid 500.

R2T15M2N2310

Ranger2 Termination. Type - Outdoor, 15kV, Cable Type - Tape Shield/Wire Shield/ Unshield, Insulation Range - .84 inch - 1.38 inch, Connector Type - Copper 2-Hole Spade #2-1250 kcmil, Conductor Code - 310 -Stranded or Compressed 400 Compact or Solid 500.
15 kv, Cable Terminator Ranger2, Outdoor, Cable Type - Tape Shield/Wire Shield/UniShield, Insulation Range 4 - 1.30 inch to 2.10 inch (33 mm to 53 mm), Connector Type N0 - Alunimum 2-Hole Spade #2-1250 kcmil, Conductor Code 410 - Compressed 1000, Cable Mounting Bracket B3 - Material Stainless Steel - Size - 1.45 inch to 1.95 inch (37mm - 50mm)

R2T15M4-N0410-B3

15 kv, Cable Terminator Ranger2, Outdoor, Cable Type - Tape Shield/Wire Shield/UniShield, Insulation Range 4 - 1.30 inch to 2.10 inch (33 mm to 53 mm), Connector Type N0 - Alunimum 2-Hole Spade #2-1250 kcmil, Conductor Code 410 - Compressed 1000, Cable Mounting Bracket B3 - Material Stainless Steel - Size - 1.45 inch to 1.95 inch (37mm - 50mm)
25/28kV, Ranger2 Cable Termination. Outdoor. Cable Type - Concentric Neutral/Jacketed Concentric Neutral. Insulation Range 1.30-2.10 inch. Connector Type Aluminum 2 Hole Spade #2-1250kcmil. Conductor Size 750kcmil Stranded/compressed 900kcmil Solid/Compact. Stainless Steel Cable Mounting Bracket 1.80-2.40 inches

R2T28J4-N0380-B4

25/28kV, Ranger2 Cable Termination. Outdoor. Cable Type - Concentric Neutral/Jacketed Concentric Neutral. Insulation Range 1.30-2.10 inch. Connector Type Aluminum 2 Hole Spade #2-1250kcmil. Conductor Size 750kcmil Stranded/compressed 900kcmil Solid/Compact. Stainless Steel Cable Mounting Bracket 1.80-2.40 inches
Outdoor, Ranger2 Termination, 15kV, Cable Type Concentric Neutral/Jacketed Concentric Neutral, Insulation Range .84 to 1.38 inch (21-35mm). Connector Type Aluminum 2-Hole Spade #2-1250 kcmil. Conductor Code 270 - 4/0 Stranded/Compressed or 250 Solid/Compact. Cable Mounting Bracket 1.10-1.50 inch (28-38mm), Plated Mild Steel.

R2T15J2-N0270-B2

Outdoor, Ranger2 Termination, 15kV, Cable Type Concentric Neutral/Jacketed Concentric Neutral, Insulation Range .84 to 1.38 inch (21-35mm). Connector Type Aluminum 2-Hole Spade #2-1250 kcmil. Conductor Code 270 - 4/0 Stranded/Compressed or 250 Solid/Compact. Cable Mounting Bracket 1.10-1.50 inch (28-38mm), Plated Mild Steel.
15kV, Outdoor, Ranger2 Termination with Mounting Bracket, Cable Type - Concentric Neutral/Jacketed Concentric Neutral, Insulation Range - 1.30-2.10 inch (33-53mm), Connector Type N2 - Copper 2-Hoel Spade #2-1250 kcmil. Conductor Code 410 - 1000 kcmil Stranded/Compressed. Cable Mounting Bracket Material - B3 - Stainless Steel - 1.45-1.95 inch (37-50mm).

R2T15J4-N2410-B3

15kV, Outdoor, Ranger2 Termination with Mounting Bracket, Cable Type - Concentric Neutral/Jacketed Concentric Neutral, Insulation Range - 1.30-2.10 inch (33-53mm), Connector Type N2 - Copper 2-Hoel Spade #2-1250 kcmil. Conductor Code 410 - 1000 kcmil Stranded/Compressed. Cable Mounting Bracket Material - B3 - Stainless Steel - 1.45-1.95 inch (37-50mm).
15kV, Ranger2 Cable Termination. Outdoor. Cable Type - Tape Shield/Wire Sheild/Unisheild. Insulation Range .64-1.12 inch. Connector Type Aluminum 1 Hole Spade #2-500kcmil. Conductor Size 4/0 Stranded/compressed 250kcmil Solid/Compact.

R2T15M1H0270

15kV, Ranger2 Cable Termination. Outdoor. Cable Type - Tape Shield/Wire Sheild/Unisheild. Insulation Range .64-1.12 inch. Connector Type Aluminum 1 Hole Spade #2-500kcmil. Conductor Size 4/0 Stranded/compressed 250kcmil Solid/Compact.
Ranger2 Termination. Type - Outdoor, 15kV, Cable Type - Tape Shield/Wire Shield/ Unshield, Insulation Range - .64 inch - 1.12 inch, Connector Type - Universal Aluminum Barrel for AL or CU Condutor with Copper Wire Lead #2-4/0, Conductor Code - 220 -Stranded/Compressed #2 or Compact/Solid #1.

R2T15M1T0220

Ranger2 Termination. Type - Outdoor, 15kV, Cable Type - Tape Shield/Wire Shield/ Unshield, Insulation Range - .64 inch - 1.12 inch, Connector Type - Universal Aluminum Barrel for AL or CU Condutor with Copper Wire Lead #2-4/0, Conductor Code - 220 -Stranded/Compressed #2 or Compact/Solid #1.
Ranger2 Termination for 25/28KV outdoor application, cable insulation diameter 1.30 - 2.10 inches for Concentric Neural and Jacketed Concentric Neutral Cable, includes Aluminum 2-Hole Spade connector for #2-1250 kcmil, Stranded/Compressed 4/0 or Compact/Solid 250, Stainless Steel Mounting Bracket 1.45 inch - 1.95 inch

R2T28J4-N0270-B3

Ranger2 Termination for 25/28KV outdoor application, cable insulation diameter 1.30 - 2.10 inches for Concentric Neural and Jacketed Concentric Neutral Cable, includes Aluminum 2-Hole Spade connector for #2-1250 kcmil, Stranded/Compressed 4/0 or Compact/Solid 250, Stainless Steel Mounting Bracket 1.45 inch - 1.95 inch

Frequently Asked Questions

Where can I find installation instructions for R2T15?

Installation instructions are IS-1134 for R2T15J, IS-1135 for R2T15M, and IS-1136 for R2T15L.

What is the IEEE classification for the R2T15 termination?

The R2T15 termination has an IEEE Classification of Outdoor = Class 1A.

What is the power system frequency range for R2T15?

The R2T15 termination is suitable for power system frequencies ranging from 48 to 62 Hz.

What is the maximum altitude for R2T15 operation?

The R2T15 termination is designed for an altitude range of 3300 feet max (1005 m).

What is the operating temperature range for the R2T15?

The R2T15 termination operates within an ambient temperature range of -22 to +149 °F (-30 to +65 °C).

What is the voltage rating of the R2T15 termination?

The R2T15 termination has a voltage rating of 15 kV. Its maximum design voltage to ground is 9.5 kV.

What cable sizes does the R2T15 termination support?

The R2T15 termination supports insulation diameter cables from 0.64 in (16 mm) to 2.10 in (53 mm), covering #2 AWG through 1250 kcmil.

Where can I find installation instructions for R2T15?

Installation instructions are IS-1134 for R2T15J, IS-1135 for R2T15M, and IS-1136 for R2T15L.

What is the power system frequency range for R2T15?

The R2T15 termination is suitable for power system frequencies ranging from 48 to 62 Hz.

What cable sizes does the R2T15 termination support?

The R2T15 termination supports insulation diameter cables from 0.64 in (16 mm) to 2.10 in (53 mm), covering #2 AWG through 1250 kcmil.

How to Install 15kV & 28kV Ranger 2 Cable Terminations

This guide provides step-by-step instructions for the safe installation of 15kV and 28kV Ranger 2 Cable Terminations on concentric and jacketed concentric neutral cables for indoor/outdoor applications. Ensure all apparatus is de-energized before starting and that installation is performed by competent personnel.

Estimated time: 1h 30m

Tools needed:

Wire strippers, Crimping tool, Approved solvent applicator (e.g., clean cloth), Abrasive (aluminum oxide, 120 grit or finer, if needed), Measuring tape or ruler, Utility knife or cable preparation tools

Supplies needed:

Silicone Rubber Termination, Lubricant, Grey Silicone Rubber Tape, Sealing Mastic, Gloves, Connector (optional), Cable Support Bracket (optional), Vinyl tape or binding wire, Approved solvent, Silicone grease

  1. Perform Initial Checks and Safety

    Check the contents of the package to ensure they are complete and undamaged. Verify all components for proper fit with the cable and/or mating products. Read the entire installation instructions before starting. Ensure all required tools are at hand and maintain cleanliness throughout the procedure. DANGER: All apparatus must be de-energized during installation or removal of parts. This product should be installed only by competent personnel trained in good safety practices involving high voltage electrical equipment.

  2. Prepare Cable Dimensions

    Confirm the cable size fits within the kit range as shown in the Termination Selection Chart. Train the cable into position and cut to the required length, allowing sufficient neutral wire length for grounding. Prepare the cable by removing the jacket, neutral wires, semi-con, and conductor to the specified dimensions, allowing for the depth of the terminal lug and additional exposed conductor distance for crimping growth (e.g., 1/4" (6mm) for #2-350 Kcmil).

  3. Apply Mastic and Secure Neutral Wires

    Carefully wrap one band of sealing mastic around the cable jacket 1/4" (6mm) from the jacket end, using a 50% stretch. Cut the mastic flush without overlapping. Bend the neutral wires back over the mastic and press them into the seal. Secure the neutral wires to the cable jacket 4-6" (100-150mm) from the cut edge using vinyl tape or binding wire. Apply a second mastic band over the neutral wires and the previously applied mastic, using a 50% stretch and cutting flush. Wrap two half-lapped layers of vinyl tape around the mastic seal, carefully maintaining the 1/4" (6mm) dimension.

  4. Install Lug or Connector

    If using a lug that will not fit through the termination core, clean the insulation and slide the termination onto the cable before installing the lug (do not remove the core yet). Position the connector/lug and crimp it according to its directions, ensuring not to crimp the last 1/4" to 3/8" of the connector. Remove any excess oxide inhibitor and sharp crimp flashings after crimping.

  5. Clean Cable Insulation and Lug Barrel

    Wipe the cable insulation with an approved solvent, ensuring the solvent does not touch the semi-con insulation shield. If an abrasive must be used, apply it only on the insulation, not the semi-con insulation shield. Use only aluminum oxide abrasive, grit 120 or finer, and be careful not to reduce the cable insulation diameter below the kit's allowed range.

  6. Prepare Termination for Installation

    Create a track-resistant moisture seal between the termination insulator and the lug/connector using the gray silicone rubber tape from the kit. Wrap a band of silicone tape around the base of the terminal lug; if the barrel diameter is smaller than the cable primary insulation, use the tape to build up the band to equal the insulation diameter. Cover the edge of the semi-con insulation shield with a liberal coating of silicone grease to fill the step at the semi-con cut-off.

  7. Install Termination Body

    For lower terminations with a fold-down skirt, pull the loose end of the removable core through the top of the termination until the core is flush with the bottom. Slide the termination body onto the cable, aligning the terminator with the forward edge of the mastic seal. Carefully begin to remove the core by unwinding it counter-clockwise, starting with the loose end. Ensure the termination body, not the core, remains butted up to the leading edge of the mastic seal. Do not push or pull on the termination assembly while removing the core material.

  8. Complete Skirt and Moisture Seal

    Apply a thin film of silicone lubricant to the skirt and mastic seal area, but do not lubricate the skirt tabs. Carefully fold down the skirt over the mastic seal. Complete the lug area moisture seal using the remaining gray silicone rubber tape. Overlap the termination insulator by approximately 1" and extend the tape wrapping over a non-crimped region of the lug/connector barrel with a half-lap configuration.

  9. Ground Neutral Wires and Final Check

    Twist the concentric neutral wires together and connect them securely to the system ground. Confirm that the High-K step does not exceed 1.5 inches.

Frequently Asked Questions about ABB - Installation Products

How are Thomas and Betts products typically installed?

Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.

What accessories are available for Thomas and Betts products?

Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.

What environmental ratings do Thomas and Betts products have?

Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.

What communication protocols do Thomas and Betts products support?

Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.

What are the key features of Thomas and Betts products?

Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.

What are the main product lines offered by Thomas and Betts?

Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.

What technical support does Thomas and Betts offer?

Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.

What industries and applications are Thomas and Betts products used for?

Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.

What certifications and standards do Thomas and Betts products comply with?

Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.

What are the main product lines offered by Ocal?

Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.