ABB - Installation Products R2T15J1-H0250 - 15kV, Outdoor, Ranger2 Cable Termination, Cable Type - Concentric Neutral/Jacket Concentric Neutral. Insulation Range 0.64 to 1.12 iches, Connector Type H0 - Aluminum 1-Hole Spade #2-500kcmil. Conductor Size - 250 - 2/0 Stranded/Compressed or 3/0 Solid/Compact.

ABB Installation Products R2T15J1-H0250 15kV, Outdoor, Ranger2 Cable Termination, Cable Type - Concentric Neutral/Jacket…

UPC: 075114331593


Documents & Media
Installation InstructionsSpecification SheetManufacturer Product Website

Contact for Pricing

Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.

Overview

The ABB Ranger2 R2T15J1-H0250 is a 15kV outdoor cable termination designed for concentric neutral and jacket concentric neutral cable types. This termination system accommodates an insulation range from 0.64 to 1.12 inches, ensuring compatibility with a variety of cable constructions. The integrated H0 connector is an aluminum, single-hole spade designed for secure and reliable connection. It is rated for conductor sizes ranging from 250 kcmil down to 2/0 AWG for stranded or compressed conductors, and 3/0 AWG for solid or compact conductors. This product is manufactured by ABB - Installation Products, a recognized name in electrical infrastructure components. The Ranger2 series provides a straightforward and effective method for terminating medium-voltage cables in outdoor environments, ensuring electrical integrity and safety. Key specifications include: * **Voltage Rating:** 15kV * **Cable Type Compatibility:** Concentric Neutral / Jacket Concentric Neutral * **Insulation Range:** 0.64 to 1.12 inches * **Connector Type:** H0 Aluminum 1-Hole Spade * **Conductor Size Compatibility:** 250 - 2/0 AWG (Stranded/Compressed) or 3/0 AWG (Solid/Compact) This termination is suitable for applications requiring reliable outdoor medium-voltage cable management. The UNSPSC code for this product is 26121648.
  • 15kV outdoor cable termination system
  • Designed for Concentric Neutral/Jacket Concentric Neutral cable types
  • Insulation range: 0.64 to 1.12 inches
  • H0 Aluminum 1-Hole Spade connector
  • Accommodates conductor sizes 250 - 2/0 AWG (Stranded/Compressed) or 3/0 AWG (Solid/Compact)

Specifications

Application
Cable Termination, Outdoor Application, 15kV
Cable Type
Concentric Neutral Wire
Color
Gray
Conductor Size
2/0 STR AWG , 2/0 COMPR AWG , 3/0 SOL AWG , 3/0 COMPT AWG
Connection Type
1-Hole Spade
Earthing
Products Includes Their Own Grounding System
Material
Aluminum
Mounting
Product Need to have Cable Holder (not included)
Mounting Type
Outdoor
Number Of Terminals
(1) Single Phase
Series
Ranger2
Size
Insulation Range 0.64 to 1.12 inches
Special Features
Silicone Rubber Housing. Lightweight, Compact Design. Pull-Down Tabs for Easy Installation. Thick Wall Construction
Standard
IEEE 48
Type
Cable Termination - Outdoor - Ranger2
Voltage Rating
15 kV
Package Dimensions (L x W x H)
0.01 IN x 0.01 IN x 0.01 IN
Package Dimensions (L x W x H)
0.0254 cm x 0.0254 cm x 0.0254 cm
Package Weight (Imperial)
1.0000 L
Package Weight (Metric)
0.4540 kg
Outdoor, Ranger2 Termination, 15kV, Concentric Neutral/Jacketed Concentric Neutral Cable Type, Insulation Range - .64-1.12 inch (16-28mm). Connector Type Universal Aluminum Barrel for AL or CU Conductor with Copper Wire Lead #2-4/0. Conductor - 2/0 Stranded/Compressed or 3/0 Compact/Solid. Cable Mounting Bracket Material - Stainless Steel, Size .80-1.25 inch (20-32mm).

R2T15J1-T0250-B1

Outdoor, Ranger2 Termination, 15kV, Concentric Neutral/Jacketed Concentric Neutral Cable Type, Insulation Range - .64-1.12 inch (16-28mm). Connector Type Universal Aluminum Barrel for AL or CU Conductor with Copper Wire Lead #2-4/0. Conductor - 2/0 Stranded/Compressed or 3/0 Compact/Solid. Cable Mounting Bracket Material - Stainless Steel, Size .80-1.25 inch (20-32mm).
Outdoor Ranger2 Cable Termination, 15kV, Concentric neutral/Jacketed Concentric Neutral Cable Type, Insulation Range .84-1.38 inch (21-mm), Connector Type - Aluminum 2-Hole Spade #2-1250 kcmil, Conductor Code 210 - #2 Compact/Solid.

R2T15J2-N0210

Outdoor Ranger2 Cable Termination, 15kV, Concentric neutral/Jacketed Concentric Neutral Cable Type, Insulation Range .84-1.38 inch (21-mm), Connector Type - Aluminum 2-Hole Spade #2-1250 kcmil, Conductor Code 210 - #2 Compact/Solid.
Outdoor Ranger2 Cable Termination, 15kV, Concentric neutral/Jacketed Concentric Neutral Cable Type, Insulation Range .84-1.38 inch (21-35mm), Connector Type - Copper 2-Hole Spade #2-1250 kcmil, Conductor Code 310 - 400 Stranded/Compressed or 500 Compact/Solid.

R2T15J2-N2310

Outdoor Ranger2 Cable Termination, 15kV, Concentric neutral/Jacketed Concentric Neutral Cable Type, Insulation Range .84-1.38 inch (21-35mm), Connector Type - Copper 2-Hole Spade #2-1250 kcmil, Conductor Code 310 - 400 Stranded/Compressed or 500 Compact/Solid.
15 kv, Cable Terminator Ranger2, Outdoor, Cable Type - Tape Shield/Wire Shield/UniShield, Insulation Range 4 - 1.30 inch to 2.10 inch (33 mm to 53 mm), Connector Type N0 - Alunimum 2-Hole Spade #2-1250 kcmil, Conductor Code 410 - Compressed 1000, Cable Mounting Bracket B3 - Material Stainless Steel - Size - 1.45 inch to 1.95 inch (37mm - 50mm)

R2T15M4-N0410-B3

15 kv, Cable Terminator Ranger2, Outdoor, Cable Type - Tape Shield/Wire Shield/UniShield, Insulation Range 4 - 1.30 inch to 2.10 inch (33 mm to 53 mm), Connector Type N0 - Alunimum 2-Hole Spade #2-1250 kcmil, Conductor Code 410 - Compressed 1000, Cable Mounting Bracket B3 - Material Stainless Steel - Size - 1.45 inch to 1.95 inch (37mm - 50mm)
25/28kV, Ranger2 Cable Termination. Outdoor. Cable Type - Concentric Neutral/Jacketed Concentric Neutral. Insulation Range 1.30-2.10 inch. Connector Type Aluminum 2 Hole Spade #2-1250kcmil. Conductor Size 750kcmil Stranded/compressed 900kcmil Solid/Compact. Stainless Steel Cable Mounting Bracket 1.80-2.40 inches

R2T28J4-N0380-B4

25/28kV, Ranger2 Cable Termination. Outdoor. Cable Type - Concentric Neutral/Jacketed Concentric Neutral. Insulation Range 1.30-2.10 inch. Connector Type Aluminum 2 Hole Spade #2-1250kcmil. Conductor Size 750kcmil Stranded/compressed 900kcmil Solid/Compact. Stainless Steel Cable Mounting Bracket 1.80-2.40 inches
Outdoor, Ranger2 Termination, 15kV, Cable Type Concentric Neutral/Jacketed Concentric Neutral, Insulation Range .84 to 1.38 inch (21-35mm). Connector Type Aluminum 2-Hole Spade #2-1250 kcmil. Conductor Code 270 - 4/0 Stranded/Compressed or 250 Solid/Compact. Cable Mounting Bracket 1.10-1.50 inch (28-38mm), Plated Mild Steel.

R2T15J2-N0270-B2

Outdoor, Ranger2 Termination, 15kV, Cable Type Concentric Neutral/Jacketed Concentric Neutral, Insulation Range .84 to 1.38 inch (21-35mm). Connector Type Aluminum 2-Hole Spade #2-1250 kcmil. Conductor Code 270 - 4/0 Stranded/Compressed or 250 Solid/Compact. Cable Mounting Bracket 1.10-1.50 inch (28-38mm), Plated Mild Steel.
15kV, Outdoor, Ranger2 Termination with Mounting Bracket, Cable Type - Concentric Neutral/Jacketed Concentric Neutral, Insulation Range - 1.30-2.10 inch (33-53mm), Connector Type N2 - Copper 2-Hoel Spade #2-1250 kcmil. Conductor Code 410 - 1000 kcmil Stranded/Compressed. Cable Mounting Bracket Material - B3 - Stainless Steel - 1.45-1.95 inch (37-50mm).

R2T15J4-N2410-B3

15kV, Outdoor, Ranger2 Termination with Mounting Bracket, Cable Type - Concentric Neutral/Jacketed Concentric Neutral, Insulation Range - 1.30-2.10 inch (33-53mm), Connector Type N2 - Copper 2-Hoel Spade #2-1250 kcmil. Conductor Code 410 - 1000 kcmil Stranded/Compressed. Cable Mounting Bracket Material - B3 - Stainless Steel - 1.45-1.95 inch (37-50mm).
15kV, Ranger2 Cable Termination. Outdoor. Cable Type - Tape Shield/Wire Sheild/Unisheild. Insulation Range .64-1.12 inch. Connector Type Aluminum 1 Hole Spade #2-500kcmil. Conductor Size 4/0 Stranded/compressed 250kcmil Solid/Compact.

R2T15M1H0270

15kV, Ranger2 Cable Termination. Outdoor. Cable Type - Tape Shield/Wire Sheild/Unisheild. Insulation Range .64-1.12 inch. Connector Type Aluminum 1 Hole Spade #2-500kcmil. Conductor Size 4/0 Stranded/compressed 250kcmil Solid/Compact.

Frequently Asked Questions

What cable insulation diameters does the R2T15 termination cover?

The R2T15 termination covers cable insulation diameters from 0.64 in (16 mm) to 2.10 in (53 mm).

What cable sizes are compatible with the R2T15 termination?

The R2T15 termination accommodates cable sizes from #2 AWG through 1250 kcmil.

What is the voltage rating of the R2T15 outdoor termination?

The R2T15 outdoor termination has a voltage rating of 15 kV.

What is the operating ambient temperature range for the R2T15?

The R2T15 termination operates within an ambient temperature range of -22 to +149 °F (-30 to +65 °C).

What is the operating ambient temperature range for the R2T15?

The R2T15 termination operates within an ambient temperature range of -22 to +149 °F (-30 to +65 °C).

What is the voltage rating of the R2T15 outdoor termination?

The R2T15 outdoor termination has a voltage rating of 15 kV.

What cable sizes are compatible with the R2T15 termination?

The R2T15 termination accommodates cable sizes from #2 AWG through 1250 kcmil.

What cable insulation diameters does the R2T15 termination cover?

The R2T15 termination covers cable insulation diameters from 0.64 in (16 mm) to 2.10 in (53 mm).

Where can I find installation instructions for R2T15?

Installation instructions are IS-1134 for R2T15J, IS-1135 for R2T15M, and IS-1136 for R2T15L.

What is the maximum altitude for R2T15 installation?

The R2T15 termination can be installed at a maximum altitude of 3300 feet (1005 meters).

How to Install the R2T15J2 Ranger 2 Cable Termination

This guide provides step-by-step instructions for installing the 15kV Ranger 2 Cable Termination (R2T15J2) on concentric and jacketed concentric neutral cables for indoor/outdoor applications. It is crucial to de-energize all apparatus before beginning installation to prevent serious injury.

Estimated time: 1h 30m

Tools needed:

Wire strippers, Crimping tool, Approved solvent, Aluminum oxide abrasive (grit 120 or finer), Measuring tape or ruler, Utility knife or cable preparation tools

Supplies needed:

R2T15J2 Silicone Rubber Termination kit, Silicone lubricant, Grey silicone rubber tape, Sealing mastic, Gloves, Vinyl tape, Binding wire (optional), Connector (optional, if not included in kit), Cable support bracket (optional)

  1. Prepare the Cable for Termination

    DANGER: Ensure all apparatus are de-energized during installation. Verify the cable size fits within the kit's specified range. Train the cable into its final position and cut it to the required length, allowing sufficient neutral wire length for grounding. Prepare the cable according to the dimensions provided in the kit's Table 1, accounting for terminal lug depth and conductor growth during crimping. Maintain cleanliness throughout the process.

  2. Apply Mastic and Secure Neutral Wires

    Using 50% stretch, carefully wrap one band of sealing mastic around the cable jacket, 1/4 inch (6mm) from the jacket end. Position it precisely as it marks the terminator's position; cut flush without overlapping. Bend the neutral wires back over the mastic and press them into it. Secure these wires to the cable jacket 4-6 inches (100-150mm) from the cut edge using vinyl tape or binding wire. Apply a second mastic band over the neutral wires and the first mastic, again using 50% stretch and cutting flush. Finally, wrap two half-lapped layers of vinyl tape around the mastic seal, maintaining the 1/4 inch (6mm) dimension.

  3. Install the Lug or Connector

    If using a lug or connector that does not fit through the termination core, clean the cable insulation and slide the termination body onto the cable *before* installing the lug (do not remove the core yet). Position the connector or lug and crimp it according to its specific instructions. Avoid crimping the last 1/4 to 3/8 inch of the connector. After crimping, remove any excess oxide inhibitor and sharp crimp flashings to ensure a smooth surface.

  4. Clean Cable Insulation and Lug Barrel

    Wipe the cable insulation thoroughly with an approved solvent. Be careful not to allow the solvent to touch the semi-con insulation shield. If abrasive cleaning is necessary, use only aluminum oxide abrasive (grit 120 or finer) on the insulation, never on the semi-con insulation shield. Ensure that the cable insulation diameter is not reduced below the kit's allowed specifications.

  5. Prepare for Termination Installation

    Create a track-resistant moisture seal between the termination insulator and the lug/connector using the gray silicone rubber tape from the kit. Wrap a band of this tape around the base of the terminal lug. If the barrel diameter is equal to or greater than the cable's primary insulation, the tape band should not exceed two layers. If the barrel diameter is smaller, use the tape strip to build up the band to match the insulation diameter. Liberally coat the edge of the semi-con insulation shield with silicone grease to fill the step at the semi-con cut-off.

  6. Install the Termination Body

    For terminations with a fold-down skirt, pull the loose end of the removable core through the top of the termination until the core is flush with the bottom. Carefully slide the termination body onto the cable, aligning its forward edge with the mastic seal. Begin to remove the core by unwinding it counter-clockwise, starting with the loose end. Ensure the termination body, not the core, is firmly butted against the leading edge of the mastic seal. Do not push or pull on the termination assembly while removing the core material.

  7. Complete Sealing and Grounding

    Apply a thin film of silicone lubricant to the skirt and the mastic seal area, but do not lubricate the skirt tabs. Carefully fold down the skirt over the mastic seal. Complete the lug area moisture seal using the remaining gray silicone rubber tape. Overlap the termination insulator by approximately 1 inch and extend the tape wrapping over a non-crimped region of the lug/connector barrel with a half-lap configuration. Twist the concentric neutral wires together and securely connect them to the system ground. Finally, confirm that the High-K step does not exceed 1.5 inches.

Frequently Asked Questions about ABB - Installation Products

How are Thomas and Betts products typically installed?

Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.

What accessories are available for Thomas and Betts products?

Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.

What environmental ratings do Thomas and Betts products have?

Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.

What communication protocols do Thomas and Betts products support?

Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.

What are the key features of Thomas and Betts products?

Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.

What are the main product lines offered by Thomas and Betts?

Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.

What technical support does Thomas and Betts offer?

Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.

What industries and applications are Thomas and Betts products used for?

Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.

What certifications and standards do Thomas and Betts products comply with?

Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.

What are the main product lines offered by Ocal?

Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.