Authorized ABB Distributor (Installation Products)
ABB - Installation Products R2T15J2N2300 - Ranger 2 Terminator, Outdoor, 15kV, Concentric Neutral/Jacketed Concentric Neutral Cable Type, Insulation Range .84 -1.38 inch (21-35mm) Connector Type - Copper 2-Hole Spade #2-1250 kcmil. 350 Stranded/Compressed or 400 Compact/Solid.

ABB Installation Products R2T15J2N2300 Ranger 2 Terminator, Outdoor, 15kV, Concentric Neutral/Jacketed Concentric Neutral Cable…

UPC: 075114325592


Documents & Media
Installation InstructionsSpecification SheetManufacturer Product Website

Contact for Pricing

Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.

Overview

The ABB Ranger 2 Terminator (SKU: R2T15J2N2300) is a robust outdoor termination solution designed for 15kV applications. This terminator is specifically engineered for use with Concentric Neutral/Jacketed Concentric Neutral cable types, ensuring reliable performance in demanding outdoor environments. It accommodates insulation diameters ranging from 0.84 to 1.38 inches (21-35mm), providing a versatile fit for various cable constructions. The integrated connector is a Copper 2-Hole Spade, compatible with cable sizes from #2 AWG up to 1250 kcmil. This includes support for 350 kcmil stranded/compressed cable and 400 kcmil compact/solid cable configurations. Manufactured by ABB - Installation Products, this terminator offers a secure and efficient connection point for your medium-voltage power distribution systems. Its design prioritizes electrical integrity and ease of installation, making it a practical choice for utility and industrial sector projects requiring dependable cable terminations. The R2T15J2N2300 is a key component for ensuring the safety and longevity of outdoor electrical infrastructure.
  • 15kV outdoor termination for Concentric Neutral/Jacketed Concentric Neutral cable
  • Insulation range: 0.84 - 1.38 inch (21-35mm)
  • Copper 2-Hole Spade connector (#2-1250 kcmil)
  • Compatible with 350 kcmil stranded/compressed or 400 kcmil compact/solid cable
  • Manufacturer: ABB - Installation Products

Specifications

Application
Cable Termination, Outdoor Application, 15kV
Cable Type
Concentric Neutral Wire
Color
Gray
Conductor Size
350 to 400 kcmil
Connection Type
2-Hole Spade #2-1250 kcmil
Current Rating
1250 kcmil
Earthing
Products Includes Their Own Grounding System
Material
Copper
Mounting
Product Need to have Cable Holder (not included)
Number Of Terminals
(1) Single Phase
Series
Ranger 2 Terminator
Size
0.84-1.38 inch (21-35mm)
Special Features
Silicone Rubber Housing. Lightweight, Compact Design. Pull-Down Tabs for Easy Installation. Thick Wall Construction
Standard
IEEE 48
Type
Cable Termination - Outdoor - Ranger2
Voltage Rating
15 kV
Package Dimensions (L x W x H)
0.01 IN x 0.01 IN x 0.01 IN
Package Dimensions (L x W x H)
0.0254 cm x 0.0254 cm x 0.0254 cm
Package Weight (Imperial)
1.0000 L
Package Weight (Metric)
0.4540 kg
Ranger2 Termination. Type - Outdoor, 15kV, Cable Type - Tape Shield/Wire Shield/ Unshield, Insulation Range - .84 inch - 1.38 inch, Connector Type - Copper 2-Hole Spade #2-1250 kcmil, Conductor Code - 300 -Stranded or Compressed 350 Compact or Solid 400.

R2T15M2-N2300

Ranger2 Termination. Type - Outdoor, 15kV, Cable Type - Tape Shield/Wire Shield/ Unshield, Insulation Range - .84 inch - 1.38 inch, Connector Type - Copper 2-Hole Spade #2-1250 kcmil, Conductor Code - 300 -Stranded or Compressed 350 Compact or Solid 400.
15kV, Ranger2 Cable Termination, Outdoor, Cable Type - Concentric Neutral/Jacketed Concentric Neutral, Insulation Range - .84-1.38 inch (21-35mm), Connector Type - N2 - Copper 2-Hole spade #2-1250 kcmil, Conductor Code 270 - 4/0 Strandeed/Compressed or 250 Compact/Solid.

R2T15J2-N2270

15kV, Ranger2 Cable Termination, Outdoor, Cable Type - Concentric Neutral/Jacketed Concentric Neutral, Insulation Range - .84-1.38 inch (21-35mm), Connector Type - N2 - Copper 2-Hole spade #2-1250 kcmil, Conductor Code 270 - 4/0 Strandeed/Compressed or 250 Compact/Solid.
15kV, Outdoor, Ranger2 Cable Termination, Cable Type - Concentric Neutral/Jacket Concentric Neutral. Insulation Range 0.64 to 1.12 iches, Connector Type H0 - Aluminum 1-Hole Spade #2-500kcmil. Conductor Size - 250 - 2/0 Stranded/Compressed or 3/0 Solid/Compact.

R2T15J1-H0250

15kV, Outdoor, Ranger2 Cable Termination, Cable Type - Concentric Neutral/Jacket Concentric Neutral. Insulation Range 0.64 to 1.12 iches, Connector Type H0 - Aluminum 1-Hole Spade #2-500kcmil. Conductor Size - 250 - 2/0 Stranded/Compressed or 3/0 Solid/Compact.
Outdoor Ranger2 Cable Termination, 15kV, Concentric neutral/Jacketed Concentric Neutral Cable Type, Insulation Range .84-1.38 inch (21-mm), Connector Type - Aluminum 2-Hole Spade #2-1250 kcmil, Conductor Code 210 - #2 Compact/Solid.

R2T15J2-N0210

Outdoor Ranger2 Cable Termination, 15kV, Concentric neutral/Jacketed Concentric Neutral Cable Type, Insulation Range .84-1.38 inch (21-mm), Connector Type - Aluminum 2-Hole Spade #2-1250 kcmil, Conductor Code 210 - #2 Compact/Solid.
Outdoor Ranger2 Cable Termination, 15kV, Concentric neutral/Jacketed Concentric Neutral Cable Type, Insulation Range .84-1.38 inch (21-35mm), Connector Type - Copper 2-Hole Spade #2-1250 kcmil, Conductor Code 310 - 400 Stranded/Compressed or 500 Compact/Solid.

R2T15J2-N2310

Outdoor Ranger2 Cable Termination, 15kV, Concentric neutral/Jacketed Concentric Neutral Cable Type, Insulation Range .84-1.38 inch (21-35mm), Connector Type - Copper 2-Hole Spade #2-1250 kcmil, Conductor Code 310 - 400 Stranded/Compressed or 500 Compact/Solid.
15 kv, Cable Terminator Ranger2, Outdoor, Cable Type - Tape Shield/Wire Shield/UniShield, Insulation Range 4 - 1.30 inch to 2.10 inch (33 mm to 53 mm), Connector Type N0 - Alunimum 2-Hole Spade #2-1250 kcmil, Conductor Code 410 - Compressed 1000, Cable Mounting Bracket B3 - Material Stainless Steel - Size - 1.45 inch to 1.95 inch (37mm - 50mm)

R2T15M4-N0410-B3

15 kv, Cable Terminator Ranger2, Outdoor, Cable Type - Tape Shield/Wire Shield/UniShield, Insulation Range 4 - 1.30 inch to 2.10 inch (33 mm to 53 mm), Connector Type N0 - Alunimum 2-Hole Spade #2-1250 kcmil, Conductor Code 410 - Compressed 1000, Cable Mounting Bracket B3 - Material Stainless Steel - Size - 1.45 inch to 1.95 inch (37mm - 50mm)
25/28kV, Ranger2 Cable Termination. Outdoor. Cable Type - Concentric Neutral/Jacketed Concentric Neutral. Insulation Range 1.30-2.10 inch. Connector Type Aluminum 2 Hole Spade #2-1250kcmil. Conductor Size 750kcmil Stranded/compressed 900kcmil Solid/Compact. Stainless Steel Cable Mounting Bracket 1.80-2.40 inches

R2T28J4-N0380-B4

25/28kV, Ranger2 Cable Termination. Outdoor. Cable Type - Concentric Neutral/Jacketed Concentric Neutral. Insulation Range 1.30-2.10 inch. Connector Type Aluminum 2 Hole Spade #2-1250kcmil. Conductor Size 750kcmil Stranded/compressed 900kcmil Solid/Compact. Stainless Steel Cable Mounting Bracket 1.80-2.40 inches
Outdoor, Ranger2 Termination, 15kV, Cable Type Concentric Neutral/Jacketed Concentric Neutral, Insulation Range .84 to 1.38 inch (21-35mm). Connector Type Aluminum 2-Hole Spade #2-1250 kcmil. Conductor Code 270 - 4/0 Stranded/Compressed or 250 Solid/Compact. Cable Mounting Bracket 1.10-1.50 inch (28-38mm), Plated Mild Steel.

R2T15J2-N0270-B2

Outdoor, Ranger2 Termination, 15kV, Cable Type Concentric Neutral/Jacketed Concentric Neutral, Insulation Range .84 to 1.38 inch (21-35mm). Connector Type Aluminum 2-Hole Spade #2-1250 kcmil. Conductor Code 270 - 4/0 Stranded/Compressed or 250 Solid/Compact. Cable Mounting Bracket 1.10-1.50 inch (28-38mm), Plated Mild Steel.

Frequently Asked Questions

What cable types does the ABB Ranger 2 Terminator support?

The ABB Ranger 2 Terminator supports Concentric Neutral and Jacketed Concentric Neutral cable types.

What is the insulation diameter range for this terminator?

The insulation diameter range for the R2T15J2N2300 is 0.84 to 1.38 inches (21-35mm).

What connector type is used on the Ranger 2 Terminator?

This terminator features a Copper 2-Hole Spade connector.

What cable sizes can be terminated with this device?

The connector is suitable for cable sizes from #2 AWG to 1250 kcmil.

Does this terminator support stranded and solid cable types?

Yes, it supports 350 kcmil stranded/compressed or 400 kcmil compact/solid cable.

How to Install 15kV & 28kV Ranger 2 Cable Termination (R2T15/28J)

This guide provides step-by-step instructions for preparing the cable, installing the lug or connector, cleaning the cable insulation, and installing the silicone rubber termination for 15kV and 28kV Ranger 2 cable terminations for indoor/outdoor applications.

Estimated time: 1h 30m

Tools needed:

Wire strippers, Crimping tool, Approved solvent, Aluminum oxide abrasive (grit 120 or finer, if needed)

Supplies needed:

Silicone Rubber Termination, Lubricant, Grey Silicone Rubber Tape, Sealing Mastic, Gloves, Connector (Optional), Cable Support Bracket (Optional), Elastimold copper or aluminum lugs (or compatible lugs), Silicone grease, Vinyl tape or binding wire

  1. Perform Initial Checks and Safety Precautions

    DANGER: All apparatus must be de-energized during installation or removal of parts. This product should be installed only by competent personnel trained in good safety practices involving high voltage electrical equipment. Failure to follow these instructions will result in damage to the product and serious or fatal injury. Check the contents of the package to ensure they are complete and undamaged. Verify all components for proper fit with the cable and/or mating products. Read the entire installation instructions before starting and have all required tools at hand, maintaining cleanliness throughout the procedure.

  2. Prepare the Cable

    Confirm the cable size fits within the kit range as shown in the Termination Selection Chart. Train the cable into position and cut it to the required length, allowing sufficient neutral wire length for grounding connection. Prepare the cable using the dimensions shown in the instructions, allowing for the depth of the terminal lug and additional exposed conductor distance for crimping aluminum lugs. Using 50% stretch, carefully wrap one band of sealing mastic around the cable jacket 1/4 inch (6mm) from the jacket end, positioning it carefully as a marker, and cut it flush without overlapping. Bend the neutral wires back over and press them into the sealing mastic, then secure them to the cable jacket 4-6 inches (100-150mm) from the cut edge using vinyl tape or binding wire. Apply a second mastic band over the neutral wires and the previously applied mastic using 50% stretch, cutting it flush without overlapping. Wrap two half-lapped layers of vinyl tape around the mastic seal, carefully maintaining the 1/4 inch (6mm) dimension.

  3. Install the Lug or Connector

    If using lugs that will not fit through the termination core, clean the insulation and slide the termination onto the cable before installing the lug (do not remove the core at this time). Position the connector or lug and crimp it according to the manufacturer's directions. Do not crimp the last 1/4 inch to 3/8 inch of the connector. After crimping, remove any excess oxide inhibitor and sharp crimp flashings.

  4. Clean Cable Insulation and Lug Barrel

    Wipe the cable insulation with an approved solvent, ensuring the solvent does not touch the semi-con insulation shield. If abrasive cleaning is necessary, use only aluminum oxide abrasive (grit 120 or finer) on the insulation only, not on the semi-con insulation shield. Be careful not to reduce the cable insulation diameter below the kit's allowed range.

  5. Install the Termination Body

    IMPORTANT: A track-resistant moisture seal must be made between the termination insulator and the lug/connector using the gray silicone rubber tape from the kit. Wrap a band of silicone tape around the base of the terminal lug; if the barrel diameter is equal to or greater than the cable primary insulation, the tape band should not exceed 2 layers. If the barrel diameter is smaller, use the tape strip to form a tape band equal to the insulation diameter. Cover the edge of the semi-con insulation shield with a liberal coating of silicone grease to fill the step at the semi-con cut-off. For lower terminations with a fold-down skirt, pull the loose end of the removable core through the top of the termination until the core is flush with the bottom. Slide the termination body onto the cable, aligning the terminator with the forward edge of the mastic seal. Carefully begin to remove the core by unwinding it counter-clockwise, starting with the loose end. Ensure the termination body, not the core, is butted up to the leading edge of the mastic seal. Do not push or pull on the termination assembly while removing the core material.

  6. Complete Sealing and Grounding

    Apply a thin film of silicone lubricant to the skirt and mastic seal area, but do not lubricate the skirt tabs. Carefully fold down the skirt over the mastic seal. With the termination installed, complete the lug area moisture seal using the remaining gray silicone rubber tape. Overlap the termination insulator by approximately 1 inch and extend the tape wrapping over a non-crimped region of the lug/connector barrel with a half-lap configuration. Twist the concentric neutral wires together and connect them to the system ground.

  7. Verify Installation

    Confirm that the High-K step does not exceed 1.5 inches.

Frequently Asked Questions about ABB - Installation Products

How are Thomas and Betts products typically installed?

Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.

What accessories are available for Thomas and Betts products?

Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.

What environmental ratings do Thomas and Betts products have?

Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.

What communication protocols do Thomas and Betts products support?

Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.

What are the key features of Thomas and Betts products?

Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.

What are the main product lines offered by Thomas and Betts?

Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.

What technical support does Thomas and Betts offer?

Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.

What industries and applications are Thomas and Betts products used for?

Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.

What certifications and standards do Thomas and Betts products comply with?

Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.

What are the main product lines offered by Ocal?

Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.