ABB - Installation Products R2T15M4-N2360-B3 - 15 kv, Cable Terminator Ranger2, Outdoor, Cable Type - Tape Shield/Wire Shield/UniShield, Insulation Range 4 - 1.30 inch to 2.10 inch (33 mm to 53 mm), Connector Type N2 - Copper 2-Hole Spade #2-1250 kcmil, Conductor Code 360 - Compressed 650/Compact 750, Cable Mounting Bracket B3 - Material Stainless Steel - Size - 1.45 inch to 1.95 inch (37mm - 50mm)

ABB Installation Products R2T15M4-N2360-B3 15 kv, Cable Terminator Ranger2, Outdoor, Cable Type - Tape Shield/Wire…

UPC: 075114379984


Documents & Media
Installation InstructionsSpecification SheetManufacturer Product Website

Contact for Pricing

Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.

Overview

The ABB Ranger2 15 kV Outdoor Cable Terminator (SKU: R2T15M4-N2360-B3) delivers reliable medium-voltage cable termination for outdoor electrical installations. Designed for tape shield, wire shield, and UniShield cables, this unit supports insulation diameters from 1.30 inches to 2.10 inches (33 mm to 53 mm), covering conductor sizes from #2 AWG to 1250 kcmil. The integrated N2 connector is a copper 2-hole spade, optimized for compressed 650 kcmil or compact 750 kcmil conductors (conductor code 360), ensuring robust electrical connectivity and current handling capacity. Engineered with shrink-fit technology and Elastimold’s pull-down jacket seal, the R2T15M4-N2360-B3 provides superior field performance with four sheds for enhanced creepage and strike distances. The non-tracking silicone housing offers exceptional weather resistance and memory, while the field-removable center core simplifies installation. The included B3 stainless steel cable mounting bracket secures cables with outer diameters between 1.45 inches and 1.95 inches (37 mm to 50 mm). Key electrical ratings include a maximum design voltage to ground of 9.5 kV, a coronal extinction voltage of ≤3pC, and a lightning impulse withstand of 110 kV crest. Optional insulating silicone sleeves are available for increased creepage or wildlife protection. Ideal for medium-voltage power distribution systems in exposed environments, this terminator accommodates popular XLP and EPR cable types. Its compact design allows installation in restricted spaces and supports free-hanging applications. Three sizes cover the full cable range, minimizing inventory while maximizing versatility.
  • Supports tape shield, wire shield, and UniShield cables with 1.30-2.10" (33-53 mm) insulation diameters
  • Accommodates conductor sizes from #2 AWG to 1250 kcmil (compressed 650 kcmil or compact 750 kcmil)
  • N2 copper 2-hole spade connector for robust electrical connection
  • Four sheds for superior creepage and strike distances in outdoor environments
  • Includes stainless steel B3 cable mounting bracket for 1.45-1.95" (37-50 mm) OD cables

Specifications

Application
Cable Termination, Outdoor Application, 15kV
Cable Type
Copper Tape Shielded Wire
Color
Gray
Conductor Size
650 to 750 kcmil
Connection Type
Tape Shield/Wire Shield/UniShield
Earthing
Products Includes Their Own Grounding System
Material
Copper
Mounting
Product Need to have Cable Holder (not included)
Mounting Type
Cable Mounting Bracket
Number Of Terminals
(1) Single Phase
Series
Cable Terminator Ranger2
Size
Insulation Range 4 - 1.30 inch to 2.10 inch (33 mm to 53 mm)
Special Features
Silicone Rubber Housing. Lightweight, Compact Design. Pull-Down Tabs for Easy Installation. Thick Wall Construction
Standard
IEEE 48
Type
Cable Termination - Outdoor - Ranger2
Voltage Rating
15 kV
Package Dimensions (L x W x H)
0.01 IN x 0.01 IN x 0.01 IN
Package Dimensions (L x W x H)
0.0254 cm x 0.0254 cm x 0.0254 cm
Package Weight (Imperial)
1.0000 L
Package Weight (Metric)
0.4540 kg
15 kV, Cable Terminator Ranger2, Outdoor, Cable Type - Tape Shield/Wire Shield/UniShield, Insulation Range 4 - 1.30 inch to 2.10 inch (33 mm to 53 mm), Connector Type N2 - Copper 2-Hole Spade #2-1250 kcmil, Conductor Code 360 - Compressed 650 kcmil or Compact 750 kcmil.

R2T15M4N2360

15 kV, Cable Terminator Ranger2, Outdoor, Cable Type - Tape Shield/Wire Shield/UniShield, Insulation Range 4 - 1.30 inch to 2.10 inch (33 mm to 53 mm), Connector Type N2 - Copper 2-Hole Spade #2-1250 kcmil, Conductor Code 360 - Compressed 650 kcmil or Compact 750 kcmil.
Indoor Ranger2 Cable Termination. 15kV, Cable Type - Concentric Neutral/Jacketed Concentric Neutral. Insulation Range - .64 inch - 1.12 inch. Aluminum 2-Hole Spade #2-1250 kcmil, Conductor 500 Stranded/Compressed or 600 Compact/Solid

R2IT15J1-N0330

Indoor Ranger2 Cable Termination. 15kV, Cable Type - Concentric Neutral/Jacketed Concentric Neutral. Insulation Range - .64 inch - 1.12 inch. Aluminum 2-Hole Spade #2-1250 kcmil, Conductor 500 Stranded/Compressed or 600 Compact/Solid
69kV, Transmission Cable Terminator, Base and Two Top Module, Housing Size 2, Connection Type 2 - 2 Hole NEMA, Connector Type - Aluminum, Conductor Size Code 30P, Metallic Screen Kit - Flat Braid, Armour Kit - Heat Shrink, No Bracket Required

69TCT322130PABN

69kV, Transmission Cable Terminator, Base and Two Top Module, Housing Size 2, Connection Type 2 - 2 Hole NEMA, Connector Type - Aluminum, Conductor Size Code 30P, Metallic Screen Kit - Flat Braid, Armour Kit - Heat Shrink, No Bracket Required
Ranger 2 Terminator, Outdoor, 15kV, Concentric Neutral/Jacketed Concentric Neutral Cable Type, Insulation Range .84 -1.38 inch (21-35mm) Connector Type - Aluminum 2-Hole Spade #2-1250 kcmil. 4/0 Stranded/Compressed or 250 kcmil Compact/Solid. Includes Stainless Steel Cable Mounting Bracket Size - 0.80 to 1.25 inch.

R2T15J2N0270-B1

Ranger 2 Terminator, Outdoor, 15kV, Concentric Neutral/Jacketed Concentric Neutral Cable Type, Insulation Range .84 -1.38 inch (21-35mm) Connector Type - Aluminum 2-Hole Spade #2-1250 kcmil. 4/0 Stranded/Compressed or 250 kcmil Compact/Solid. Includes Stainless Steel Cable Mounting Bracket Size - 0.80 to 1.25 inch.
Outdoor Ranger2 Cable Termination. 35kV, Cable Type - Tape Shield/Wire Shield/UniShield. Insulation Range - .84 inch - 1.38 inch. Aluminum 1-Hole Spade #2-500 kcmil, Conductor 2/0 Stranded/Compressed AWG or 3/0 Compact/Solid AWG

R2T35M2-H0250

Outdoor Ranger2 Cable Termination. 35kV, Cable Type - Tape Shield/Wire Shield/UniShield. Insulation Range - .84 inch - 1.38 inch. Aluminum 1-Hole Spade #2-500 kcmil, Conductor 2/0 Stranded/Compressed AWG or 3/0 Compact/Solid AWG
Outdoor Ranger2 Cable Termination. 35kV, Cable Type - Tape Shield/Wire Shield/UniShield. Insulation Range - 1.30 inch - 2.10 inch. Aluminum 2-Hole Spade #2-1250 kcmil, Conductor 750 kcmil Stranded/Compressed or 900 kcmil Compact/Solid

R2T35M4-N0380

Outdoor Ranger2 Cable Termination. 35kV, Cable Type - Tape Shield/Wire Shield/UniShield. Insulation Range - 1.30 inch - 2.10 inch. Aluminum 2-Hole Spade #2-1250 kcmil, Conductor 750 kcmil Stranded/Compressed or 900 kcmil Compact/Solid
Ranger2 Termination for 25/28 kV Outdoor Application, Cable Insulation Diameter 1.30 - 2.10 inches for Concentric Neural and Jacketed Concentric Neutral Cable, includes Copper 2-Hole Spade connector for #2-1250 kcmil, Stranded or Compressed 500 kcmil or Compact Solid 600 kcmil. Stainless Steel Mounting Bracket 1.45 inch - 1.95 inch (37-50mm)

R2T28J4N2330-B3

Ranger2 Termination for 25/28 kV Outdoor Application, Cable Insulation Diameter 1.30 - 2.10 inches for Concentric Neural and Jacketed Concentric Neutral Cable, includes Copper 2-Hole Spade connector for #2-1250 kcmil, Stranded or Compressed 500 kcmil or Compact Solid 600 kcmil. Stainless Steel Mounting Bracket 1.45 inch - 1.95 inch (37-50mm)
Ranger2 Termination for 15KV outdoor application, cable insulation diameter 1.30 - 2.10 inches for Cable Type - Tape Shield/Wire Shield/Unshield Cable, Copper 2-Hole Spade #2-1250kcmil, Stranded or Compressed 900 /Compact or Solid 1000. - Cable Mounting Bracket - Stainless Steel, 1.45 inch - 1.95 inch (37-50mm)

R2T15M4-N2400-B3

Ranger2 Termination for 15KV outdoor application, cable insulation diameter 1.30 - 2.10 inches for Cable Type - Tape Shield/Wire Shield/Unshield Cable, Copper 2-Hole Spade #2-1250kcmil, Stranded or Compressed 900 /Compact or Solid 1000. - Cable Mounting Bracket - Stainless Steel, 1.45 inch - 1.95 inch (37-50mm)

Frequently Asked Questions

What cable insulation diameters does this termination support?

The R2T termination supports insulation diameters from 0.64 inches (16 mm) to 2.10 inches (53 mm).

What is the voltage rating of the R2T15 termination?

The R2T15 outdoor cable termination has a voltage rating of 15 kV.

What is the maximum design voltage to ground?

The maximum design voltage to ground for the R2T15 termination is 9.5 kV.

What is the ambient temperature range for operation?

The R2T15 operates within an ambient temperature range of -22 to +149 °F (-30 to +65 °C).

What cable types are compatible with the R2T15 termination?

The R2T15 accommodates popular XLP and EPR cable types, including various shield constructions.

What power system frequencies are supported by the R2T15?

The R2T15 termination supports power system frequencies ranging from 48 to 62 Hz.

What is the maximum altitude for installing this termination?

The maximum altitude for installing the R2T15 termination is 3300 feet (1005 m).

How is the R2T15 cable termination typically mounted?

The R2T15 termination can be free hanging or mounted using an optional support bracket.

What are the available sizes for the R2T15 termination?

The R2T15 termination is available in sizes 1, 2, and 4.

What is the IEEE classification for this outdoor termination?

The IEEE classification for the R2T15 outdoor termination is Class 1A.

How to Install the R2T15M4 Ranger 2 Shrink-fit Silicone Rubber Termination

This guide provides detailed instructions for installing the R2T15M4 Ranger 2 Shrink-fit Silicone Rubber Termination on 15kV and 28kV tape-shielded cables, covering cable preparation, ground braid installation, and final termination sealing.

Tools needed:

Crimping tool, Wire strippers, Solvent applicator, Aluminum oxide abrasive (grit 120 or finer)

Supplies needed:

R2T15M4 Termination Kit, Silicone Lubricant, Gray Silicone Rubber Electrical Tape, Constant Force Spring, Preformed Ground Braid, Sealing Mastic, Copper Foil Tape, Vinyl Tape, Terminal Lug or Connector, Approved solvent, Clean cloths/pads, Gloves

  1. Prepare the Cable and Ensure Safety

    DANGER: De-energize all apparatus before beginning installation. Do not touch or move energized products. This installation must be performed only by competent personnel trained in high voltage safety practices. Check that the cable size is compatible with the R2T15M4 termination kit using the Termination Selection Chart. Train the cable into its final position and cut it to the required length, allowing for the depth of the terminal lug and any growth allowance for aluminum lugs. Prepare the cable by removing the jacket, tape shield, and semi-conductive layer according to the specified dimensions (refer to "A" in Table 1 for jacket removal length). Secure the edge of the tape shield with a single wrap of the supplied copper foil tape to prevent unrolling.

  2. Install the Ground Braid

    Apply the first band of sealing mastic around the cable jacket, 1/4" (6mm) from the jacket end, using 50% stretch. Ensure it is flush and does not overlap. This mastic also serves as a termination positioning marker. Position the preformed ground braid with its short tail over the tape shield and the solder block centered over the mastic strip. Secure the ground braid to the cable jacket with vinyl tape and press the solder block firmly into the mastic. Apply a second mastic band over the solder block and the first mastic, maintaining the 1/4" (6mm) dimension, using 50% stretch. Cut flush. Wrap two half-lapped layers of vinyl tape around the mastic seal, maintaining the 1/4" (6mm) dimension. Wrap the ground braid around the cable tape shield for one complete wrap, trim any excess to prevent overlap, and secure it in place with the constant force spring. Wrap the spring in the same direction as the ground braid, cinch it after the final winding, and secure it with two wraps of vinyl tape.

  3. Install the Terminal Lug and Clean Cable Insulation

    Verify that the termination assembly can fit over the selected terminal lug or connector. If not, clean the cable insulation and slide the termination body onto the cable before installing the lug. Do not remove the termination core at this stage. Position the connector or lug and crimp it according to the manufacturer's instructions. Do not crimp the last 3/8" to 1/2" of the connector. Remove any excess oxide inhibitor and all sharp crimp flashings or edges from the crimped lug. Clean the cable insulation thoroughly with an approved solvent, ensuring the solvent does not touch the semi-conductive insulation shield. If using an abrasive, apply only to the insulation, use aluminum oxide grit 120 or finer, and avoid reducing the cable insulation diameter.

  4. Install and Seal the Termination Body

    Create a track-resistant moisture seal by wrapping gray silicone rubber electrical tape around the base of the terminal lug. Apply 1-2 layers if the barrel diameter is equal to or greater than the cable primary insulation, or build up the tape band to match the insulation diameter if the barrel is smaller. Apply a liberal coating of silicone grease to the edge of the semi-conductive insulation shield to fill the step at the cut-off point. Pull the loose end of the removable core through the top of the termination until the core is flush with the bottom of the termination. Slide the termination body onto the cable, aligning its forward edge with the mastic seal. Carefully remove the core by unwinding it counter-clockwise, starting with the loose end. Ensure the termination body, not the core, is butted against the leading edge of the mastic seal. Do not push or pull the termination assembly during core removal. Apply a thin film of silicone lubricant to the skirt and mastic seal area, but avoid the skirt tabs. Carefully fold down the skirt over the mastic seal.

  5. Complete Moisture Seal and Ground Connection

    Complete the lug area moisture seal using the remaining gray silicone rubber electrical tape. Overlap the termination insulator by approximately 1" and extend the tape wrapping over a non-crimped region of the lug/connector barrel using a half-lap configuration. Connect the ground braid securely to the system ground. Confirm that the High-K step of the termination does not exceed 1.5" (38mm) to ensure proper stress relief.

Frequently Asked Questions about ABB - Installation Products

How are Thomas and Betts products typically installed?

Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.

What accessories are available for Thomas and Betts products?

Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.

What environmental ratings do Thomas and Betts products have?

Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.

What communication protocols do Thomas and Betts products support?

Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.

What are the key features of Thomas and Betts products?

Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.

What are the main product lines offered by Thomas and Betts?

Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.

What technical support does Thomas and Betts offer?

Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.

What industries and applications are Thomas and Betts products used for?

Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.

What certifications and standards do Thomas and Betts products comply with?

Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.

What are the main product lines offered by Ocal?

Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.