ABB - Installation Products R2IT15J1-N0330 - Indoor Ranger2 Cable Termination. 15kV, Cable Type - Concentric Neutral/Jacketed Concentric Neutral. Insulation Range - .64 inch - 1.12 inch. Aluminum 2-Hole Spade #2-1250 kcmil, Conductor 500 Stranded/Compressed or 600 Compact/Solid

ABB Installation Products R2IT15J1-N0330 Indoor Ranger2 Cable Termination. 15kV, Cable Type - Concentric Neutral/Jacketed…

UPC: 075114379588


Documents & Media
Installation InstructionsSpecification SheetManufacturer Product Website

Contact for Pricing

Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.

Overview

The ABB R2IT15J1-N0330 is an indoor cable termination designed for 15kV applications. This unit is specifically engineered for Concentric Neutral and Jacketed Concentric Neutral cable types, ensuring reliable performance in electrical distribution systems. The insulation range accommodated by this termination is between 0.64 inches and 1.12 inches, providing flexibility for various cable sizes. It features an aluminum 2-hole spade connector, compatible with conductor sizes from #2 AWG to 1250 kcmil. Specifically, it supports 500 kcmil stranded/compressed conductors or 600 kcmil compact/solid conductors. This product, part of ABB's Installation Products line (SKU: R2IT15J1-N0330), is built for secure and efficient cable termination in industrial and utility environments. Its robust construction and precise specifications ensure a dependable connection, critical for maintaining power continuity and system integrity. The UNSPSC code for this product is 26121648, categorizing it within electrical power distribution equipment. ABB's commitment to quality in their Installation Products ensures that the R2IT15J1-N0330 meets the demanding requirements of modern electrical infrastructure.
  • 15kV indoor cable termination
  • For Concentric Neutral/Jacketed Concentric Neutral cables
  • Insulation range: 0.64" - 1.12"
  • Aluminum 2-hole spade for #2-1250 kcmil conductors
  • Supports 500 kcmil stranded/compressed or 600 kcmil compact/solid conductors

Specifications

Application
Cable Termination, Indoor Application, 15kV
Cable Type
Concentric Neutral Wire
Color
Gray
Conductor Size
500 to 600 kcmil
Connection Type
2-Hole Spade
Earthing
Products Includes Their Own Grounding System
Material
Aluminum
Number Of Terminals
(1) Single Phase
Series
Ranger2
Size
0.64 inch - 1.12 inch
Size
0.64-1.12 inch
Special Features
Silicone Rubber Housing. Lightweight, Compact Design. Pull-Down Tabs for Easy Installation. Thick Wall Construction
Standard
IEEE 48
Type
Cable Termination - Indoor - Ranger2
Voltage Rating
15 kV
Package Dimensions (L x W x H)
0.01 IN x 0.01 IN x 0.01 IN
Package Dimensions (L x W x H)
0.0254 cm x 0.0254 cm x 0.0254 cm
Package Weight (Imperial)
1.0000 L
Package Weight (Metric)
0.4540 kg
Ranger2 Termination for 15KV outdoor application, cable insulation diameter .64 - 1.12 inches for Concentric Neural and Jacketed Concentric Neutral Cable, Aluminum 2 Hole Spade #2-1250kcmil, Stranded or Compressed 500 /Compact or Solid 600.

R2T15J1-N0330

Ranger2 Termination for 15KV outdoor application, cable insulation diameter .64 - 1.12 inches for Concentric Neural and Jacketed Concentric Neutral Cable, Aluminum 2 Hole Spade #2-1250kcmil, Stranded or Compressed 500 /Compact or Solid 600.
69kV, Transmission Cable Terminator, Base and Two Top Module, Housing Size 2, Connection Type 2 - 2 Hole NEMA, Connector Type - Aluminum, Conductor Size Code 30P, Metallic Screen Kit - Flat Braid, Armour Kit - Heat Shrink, No Bracket Required

69TCT322130PABN

69kV, Transmission Cable Terminator, Base and Two Top Module, Housing Size 2, Connection Type 2 - 2 Hole NEMA, Connector Type - Aluminum, Conductor Size Code 30P, Metallic Screen Kit - Flat Braid, Armour Kit - Heat Shrink, No Bracket Required
Ranger 2 Terminator, Outdoor, 15kV, Concentric Neutral/Jacketed Concentric Neutral Cable Type, Insulation Range .84 -1.38 inch (21-35mm) Connector Type - Aluminum 2-Hole Spade #2-1250 kcmil. 4/0 Stranded/Compressed or 250 kcmil Compact/Solid. Includes Stainless Steel Cable Mounting Bracket Size - 0.80 to 1.25 inch.

R2T15J2N0270-B1

Ranger 2 Terminator, Outdoor, 15kV, Concentric Neutral/Jacketed Concentric Neutral Cable Type, Insulation Range .84 -1.38 inch (21-35mm) Connector Type - Aluminum 2-Hole Spade #2-1250 kcmil. 4/0 Stranded/Compressed or 250 kcmil Compact/Solid. Includes Stainless Steel Cable Mounting Bracket Size - 0.80 to 1.25 inch.
Outdoor Ranger2 Cable Termination. 35kV, Cable Type - Tape Shield/Wire Shield/UniShield. Insulation Range - .84 inch - 1.38 inch. Aluminum 1-Hole Spade #2-500 kcmil, Conductor 2/0 Stranded/Compressed AWG or 3/0 Compact/Solid AWG

R2T35M2-H0250

Outdoor Ranger2 Cable Termination. 35kV, Cable Type - Tape Shield/Wire Shield/UniShield. Insulation Range - .84 inch - 1.38 inch. Aluminum 1-Hole Spade #2-500 kcmil, Conductor 2/0 Stranded/Compressed AWG or 3/0 Compact/Solid AWG
Outdoor Ranger2 Cable Termination. 35kV, Cable Type - Tape Shield/Wire Shield/UniShield. Insulation Range - 1.30 inch - 2.10 inch. Aluminum 2-Hole Spade #2-1250 kcmil, Conductor 750 kcmil Stranded/Compressed or 900 kcmil Compact/Solid

R2T35M4-N0380

Outdoor Ranger2 Cable Termination. 35kV, Cable Type - Tape Shield/Wire Shield/UniShield. Insulation Range - 1.30 inch - 2.10 inch. Aluminum 2-Hole Spade #2-1250 kcmil, Conductor 750 kcmil Stranded/Compressed or 900 kcmil Compact/Solid
Ranger2 Termination for 25/28 kV Outdoor Application, Cable Insulation Diameter 1.30 - 2.10 inches for Concentric Neural and Jacketed Concentric Neutral Cable, includes Copper 2-Hole Spade connector for #2-1250 kcmil, Stranded or Compressed 500 kcmil or Compact Solid 600 kcmil. Stainless Steel Mounting Bracket 1.45 inch - 1.95 inch (37-50mm)

R2T28J4N2330-B3

Ranger2 Termination for 25/28 kV Outdoor Application, Cable Insulation Diameter 1.30 - 2.10 inches for Concentric Neural and Jacketed Concentric Neutral Cable, includes Copper 2-Hole Spade connector for #2-1250 kcmil, Stranded or Compressed 500 kcmil or Compact Solid 600 kcmil. Stainless Steel Mounting Bracket 1.45 inch - 1.95 inch (37-50mm)
Ranger2 Termination for 15KV outdoor application, cable insulation diameter 1.30 - 2.10 inches for Cable Type - Tape Shield/Wire Shield/Unshield Cable, Copper 2-Hole Spade #2-1250kcmil, Stranded or Compressed 900 /Compact or Solid 1000. - Cable Mounting Bracket - Stainless Steel, 1.45 inch - 1.95 inch (37-50mm)

R2T15M4-N2400-B3

Ranger2 Termination for 15KV outdoor application, cable insulation diameter 1.30 - 2.10 inches for Cable Type - Tape Shield/Wire Shield/Unshield Cable, Copper 2-Hole Spade #2-1250kcmil, Stranded or Compressed 900 /Compact or Solid 1000. - Cable Mounting Bracket - Stainless Steel, 1.45 inch - 1.95 inch (37-50mm)
Ranger2 Termination for 15KV outdoor application, cable insulation diameter 1.30 - 2.10 inches for Concentric Neural and Jacketed Concentric Neutral Cable, includes Aluminum 2-Hole Spade connector for #2-1250 kcmil, Wire Size Stranded or Compressed 750 kcmil / Compact or Solid 900 kcmil. Stainless Steel Mounting Bracket 1.80 inch - 2.40 inch (45-61mm)

R2T15J4-N0380-B4

Ranger2 Termination for 15KV outdoor application, cable insulation diameter 1.30 - 2.10 inches for Concentric Neural and Jacketed Concentric Neutral Cable, includes Aluminum 2-Hole Spade connector for #2-1250 kcmil, Wire Size Stranded or Compressed 750 kcmil / Compact or Solid 900 kcmil. Stainless Steel Mounting Bracket 1.80 inch - 2.40 inch (45-61mm)

Frequently Asked Questions

What cable types is this ABB termination for?

This ABB R2IT15J1-N0330 termination is designed for Concentric Neutral and Jacketed Concentric Neutral cable types.

What is the insulation range for this termination?

The insulation range for the R2IT15J1-N0330 is between 0.64 inches and 1.12 inches.

What conductor sizes does the aluminum spade support?

The aluminum 2-hole spade supports conductor sizes from #2 AWG to 1250 kcmil, specifically 500 kcmil stranded/compressed or 600 kcmil compact/solid.

What is the voltage rating of the R2IT15J1-N0330?

The ABB R2IT15J1-N0330 is rated for 15kV applications.

How to Install the R2IT15J1-N0330 15kV Ranger 2 Cable Terminator

This guide provides step-by-step instructions for the indoor installation of the R2IT15J1-N0330 15kV Ranger 2 Cable Terminator on concentric and jacketed concentric neutral cables. Ensure all safety precautions are followed.

Tools needed:

Wire strippers, Crimping tool, Approved solvent, Clean rags, Aluminum oxide abrasive (120 grit or finer, if needed)

Supplies needed:

Silicone Rubber Termination kit (includes termination, lubricant, gloves), Cable, Terminal lug or connector, Vinyl tape, Cable support bracket (optional), System ground connection

  1. Prepare Cable for Termination

    DANGER: All apparatus must be de-energized during installation. This product should be installed only by competent personnel trained in good safety practices involving high voltage electrical equipment. Before starting, ensure all apparatus is de-energized. Check that the cable size fits the kit range. Train the cable into position and cut to the required length, allowing sufficient neutral wire length for grounding. Prepare the cable by removing the jacket, neutral wires, and semi-con insulation shield according to the specified dimensions (e.g., 9-1/2” for cable jacket, 1-1/2” for neutral wires, and specific lengths for semi-con based on cable size). Bend the neutral wires back and secure them, for example, with vinyl tape.

  2. Install Terminal Lug or Connector

    If using a non-Elastimold lug that will not fit through the termination core, first clean the cable insulation and slide the termination body onto the cable (do not remove the core yet). Position the terminal lug or connector onto the prepared conductor and crimp it according to the manufacturer's directions, ensuring not to crimp the last 1/4” to 3/8” of the connector. After crimping, remove any excess oxide inhibitor and sharp crimp flashings.

  3. Clean Cable Insulation and Lug

    Thoroughly wipe the cable insulation with an approved solvent, being careful not to let the solvent touch the semi-con insulation shield. If necessary, use an aluminum oxide abrasive (120 grit or finer) on the insulation only; do not use it on the semi-con insulation shield and ensure the cable insulation diameter is not reduced below the kit's allowance.

  4. Install and Ground the Termination

    WARNING: This 15kV indoor kit does not restore a moisture-resistant seal to the cable termination. If moisture resistance is required, use an indoor/outdoor kit. Apply a liberal coating of silicone grease to the edge of the semi-con insulation shield to fill the step at the cut-off. Slide the terminator body onto the cable, aligning its skirt with the edge of the cable jacket. Carefully remove the termination core by rotating the lead counter-clockwise while pulling. Recheck the terminator position and continue removing the core, avoiding pushing or pulling on the assembly. Finally, twist the concentric neutral wires together and securely connect them to the system ground.

Frequently Asked Questions about ABB - Installation Products

How are Thomas and Betts products typically installed?

Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.

What accessories are available for Thomas and Betts products?

Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.

What environmental ratings do Thomas and Betts products have?

Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.

What communication protocols do Thomas and Betts products support?

Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.

What are the key features of Thomas and Betts products?

Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.

What are the main product lines offered by Thomas and Betts?

Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.

What technical support does Thomas and Betts offer?

Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.

What industries and applications are Thomas and Betts products used for?

Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.

What certifications and standards do Thomas and Betts products comply with?

Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.

What are the main product lines offered by Ocal?

Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.