ABB Installation Products 69TCT322130PABN 69kV, Transmission Cable Terminator, Base and Two Top Module, Housing Size 2, Connection…
UPC: 783786426874
Contact for Pricing
Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.
Overview
- 69kV Transmission Cable Terminator for high-voltage applications.
- Housing Size 2 configuration for optimized cable fit.
- 2-Hole NEMA connection type for standard mounting.
- Aluminum connector for superior conductivity and corrosion resistance.
- Conductor Size Code 30P compatibility.
- Includes Flat Braid Metallic Screen Kit for EMI management.
- Integrated Heat Shrink Armour Kit for mechanical and environmental protection.
- Bracket-free design for streamlined installation.
Specifications
Application | Cable Terminations, 69kV |
Cable Type | Copper Tape Shielded Wire |
Color | Gray |
Conductor Size | 0.636 to 0.686 in |
Connection Type | 2-Hole NEMA |
Earthing | Products Includes Their Own Grounding System |
Material | Aluminum |
Mounting | No Bracket Required |
Mounting Type | No Bracket Required |
Nema Rating | 2-Hole NEMA |
Number Of Terminals | (1) Single Phase |
Size | Housing Size 2 |
Special Features | Molded EPDM Elastomer Housing is Durable under Severe Envoronmental Conditions. Lightweight and easy to Handle |
Standard | IEEE 48 and IEC-840 |
Type | Cable Termination |
Voltage Rating | 69 kV |
Package Dimensions (L x W x H) | 0.01 IN x 0.01 IN x 0.01 IN |
Package Dimensions (L x W x H) | 0.0254 cm x 0.0254 cm x 0.0254 cm |
Package Weight (Imperial) | 1.0000 L |
Package Weight (Metric) | 0.4540 kg |

69TCT222130PABN
69kV, Transmission Cable Terminator, Base and Top Module, Housing Size 2, Connection Type 2 - 2 Hole NEMA, Connector Type - Aluminum, Conductor Size Code 30P, Metallic Screen Kit - Flat Braid, Armour Kit - Heat Shrink, No Bracket Required
R2T15J2N0270-B1
Ranger 2 Terminator, Outdoor, 15kV, Concentric Neutral/Jacketed Concentric Neutral Cable Type, Insulation Range .84 -1.38 inch (21-35mm) Connector Type - Aluminum 2-Hole Spade #2-1250 kcmil. 4/0 Stranded/Compressed or 250 kcmil Compact/Solid. Includes Stainless Steel Cable Mounting Bracket Size - 0.80 to 1.25 inch.
R2T35M2-H0250
Outdoor Ranger2 Cable Termination. 35kV, Cable Type - Tape Shield/Wire Shield/UniShield. Insulation Range - .84 inch - 1.38 inch. Aluminum 1-Hole Spade #2-500 kcmil, Conductor 2/0 Stranded/Compressed AWG or 3/0 Compact/Solid AWG
R2T35M4-N0380
Outdoor Ranger2 Cable Termination. 35kV, Cable Type - Tape Shield/Wire Shield/UniShield. Insulation Range - 1.30 inch - 2.10 inch. Aluminum 2-Hole Spade #2-1250 kcmil, Conductor 750 kcmil Stranded/Compressed or 900 kcmil Compact/Solid
R2T28J4N2330-B3
Ranger2 Termination for 25/28 kV Outdoor Application, Cable Insulation Diameter 1.30 - 2.10 inches for Concentric Neural and Jacketed Concentric Neutral Cable, includes Copper 2-Hole Spade connector for #2-1250 kcmil, Stranded or Compressed 500 kcmil or Compact Solid 600 kcmil. Stainless Steel Mounting Bracket 1.45 inch - 1.95 inch (37-50mm)
R2T15M4-N2400-B3
Ranger2 Termination for 15KV outdoor application, cable insulation diameter 1.30 - 2.10 inches for Cable Type - Tape Shield/Wire Shield/Unshield Cable, Copper 2-Hole Spade #2-1250kcmil, Stranded or Compressed 900 /Compact or Solid 1000. - Cable Mounting Bracket - Stainless Steel, 1.45 inch - 1.95 inch (37-50mm)
R2T15J4-N0380-B4
Ranger2 Termination for 15KV outdoor application, cable insulation diameter 1.30 - 2.10 inches for Concentric Neural and Jacketed Concentric Neutral Cable, includes Aluminum 2-Hole Spade connector for #2-1250 kcmil, Wire Size Stranded or Compressed 750 kcmil / Compact or Solid 900 kcmil. Stainless Steel Mounting Bracket 1.80 inch - 2.40 inch (45-61mm)
R2T15J2-N2360-B3
Ranger2 Termination, Outdoor, 15kv, Cable Type - Concentric Neutral/Jacketed Concentric Neutral, Insulation Range - .84 inch - 1.38 inch (21mm-35mm), Connector Type - N2 - Copper 2-Hole Spade #2-1250 kcmil, 650 Stranded/Compressed or 750 Compact/Solid, B3 - Cable Mounting Bracket - Stainless Steel - 1.45 inch - 1.95 inch (37-50mm)Frequently Asked Questions
What is the nominal voltage of the 69TCT Terminator?
The nominal voltage (Uo/U) for the 69TCT Terminator is 40kV/59kV.
What material is the 69TCT Terminator housing made of?
The housing is made of molded EPDM elastomer, which is durable under severe environmental conditions.
How long does the installation of the 69TCT Terminator take?
Installation can be accomplished in 45 minutes after cable preparation, using the Elastimold TCJ-ATK-U Universal Assembly Tool.
Can the 69TCT Terminator be installed without a crane?
Yes, it can be assembled horizontally on the ground and then raised to the installation position without a crane.
How much does the 69TCT Terminator weigh?
The 69TCT Terminator is lightweight, weighing 14kg (30.1 lb.).
Does the terminator require surface oil or grease for maintenance?
No, the non-tracking polymer housing requires no surface oil or grease to maintain its properties.
What standards does the 69TCT Terminator conform to?
The 69TCT Terminator conforms to IEC-840 and IEEE-48 standards.
What conductor sizes does the 69TCT Terminator accommodate?
It accommodates conductor sizes from 90mm2 (4/0) to 1700mm2 (3500 kcmil).
What are the compatible cable insulation diameters?
The terminator is designed for cable insulation diameters up to 86.4mm (3.400 inches).
What cable systems is the 69TCT Terminator designed for?
It provides a Class 1 termination for solid dielectric cable systems rated through 69kV class.
How to Install the ELASTIMOLD TCT Outdoor Transmission Cable Termination
This guide provides detailed instructions for the safe and proper installation of the ELASTIMOLD TCT outdoor transmission cable termination, including cable preparation, component assembly, and final mounting.
Estimated time: 3h
Tools needed:
Measuring Tape, Wire Strippers, Cable Cleaner, Hose Clamp, Wirebrush, Crimping Tool, Heat Gun, Soldering Iron, Screwdriver
Supplies needed:
ELASTIMOLD TCT Termination Kit (includes spade contact, heat shrink sleeve, semi-conductive paint, lubricant, cable clamp, winch assembly, adapter plates, housing clamp, terminator base section, terminator module section, mastic, scintillation ring, #12 A, Vinyl Tape Marker, Mastic Tape, Supporting Structure, Mounting Hardware
- Prepare for Installation and Safety Check
DANGER: Ensure all apparatus is de-energized before starting installation. Verify all components in the ELASTIMOLD TCT kit are complete and undamaged. Confirm proper fit with the cable and/or mating products. Have all required tools at hand and maintain cleanliness throughout the procedure. This product should only be installed by competent personnel trained in high voltage electrical equipment safety practices.
- Prepare the Cable End
Straighten the cable and place it in its final position, using the spade contact as a guide. Square cut the cable end and note the depth of the spade contact hole (X). Carefully remove the outer jacket material to a distance of 45.5 inches (111.6 cm) from the cable end to expose the shield. Slide the heat shrink sleeve onto the cable.
- Remove Shield and Non-Metallic Screen
Remove the cable shield to a distance of 43.5 inches (110.5 cm) from the cable end. Remove the non-metallic screen to a distance of 40 inches (101.5 cm) from the end of the conductor, being careful not to cut or nick the exposed insulation. Chamfer the non-metallic screen edge for a minimum of 1/2 inch (1.5 cm).
- Cut and Chamfer Cable Insulation
Using a hose clamp as a guide, square cut the cable insulation at a distance of X+1 inch from the end of the conductor, ensuring not to nick the conductor. Remove the hose clamp. Sand out any nicks and abrasions on the extruded non-metallic screen chamfer and cable insulation. Chamfer the edge of the cable insulation for approximately 3 inches (7.5 cm).
- Clean and Paint Cable Insulation
Clean the cable insulation and extruded non-metallic screen using cable cleaner, wiping toward the outer jacket to prevent contamination. Place a vinyl tape marker on the cable insulation surface at 39.5 inches (100.5 cm) from the conductor end. Stir the supplied semi-conductive paint well. Paint the exposed insulation and a minimum of 1 inch (2.5 cm) of the extruded non-metallic screen. Remove the vinyl tape within 5 to 15 minutes, ensuring the paint edge is smooth and square. Allow the paint 60 minutes to dry.
- Assemble Cable Clamp and Winch Assembly
Place a vinyl tape marker onto the cable non-metallic shield 2 inches (5 cm) from the edge of the paint. Assemble the Cable Clamp at least 55 inches (140 cm) back from the conductor and tighten it securely. Place the Winch Assembly in front of the Cable Clamp and attach its stationary hooks to the Cable Clamp. Attach the Adapter Plates to the Housing Clamp with the supplied bolts and assemble the Housing Clamp around the Terminator Base Section. Extend the steel cable(s) on the Winch Assembly until the hooks reach the Housing Clamp, then hook the cables to the Housing Clamp. Thoroughly lubricate the cable in the specified area and direction with the supplied lubricant.
- Assemble Terminator Sections
Assemble the Terminator Base Section onto the cable approximately 12 inches from the end. Release tension on each steel cable. Extend the steel cables and Housing Clamp. Position the Terminator Module Section in the Housing Clamp. Install the units until they overlap and continue assembling the mated units until the Terminator Base Section is flush with the tape marker. Remove the Winch Assembly, Housing Clamp, Adapter Plate, and Cable Clamp.
- Connect and Crimp Conductor
Remove the tape marker on the insulation shield. Remove the cut section of insulation on the cable to expose the conductor. Wirebrush the conductor of the cable and immediately insert it into the spade contact. Crimp the connector according to the enclosed crimping instructions, starting at the crimp line and working outward toward the TCT. Remove any excess inhibitor where applicable. Apply 2 layers of mastic: one at the end of the stress cone and one 2 inches (5 cm) back from the end of the cable jacket.
- Install Grounding and Seal Components
Install the scintillation ring and the #12 AWG copper drain wire. Solder the flat braid and the #12 drain wire to the shield. Apply a second layer of mastic over the drain wire, on top of the previously applied mastic around the base of the stress cone. Apply a second layer of mastic over the flat braid, on top of the previously applied mastic on the cable jacket. Slide the heat shrink sleeve up to the grounding eye of the base of the terminator. Apply heat to the sleeve, starting in the middle and continuing toward each end of the tube until mastic sealer squeezes from the ends. Connect the flat braid to the system ground. Seal the cable end with mastic tape between the contact and cable insulation. Apply two half-lapped layers of silicone tape covering the crimp connector, mastic tape, and the upper portion of the terminator skirt.
- Mount Terminated Cables
Mount the terminated cables to a supporting structure. Ensure that a minimum clearance of 4.0 inches (10 cm) is maintained between the terminator stress cone base and the supporting structure. All apparatus must be installed and operated in accordance with individual user, local, and national work rules.
Frequently Asked Questions about ABB - Installation Products
How are Thomas and Betts products typically installed?
Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.
What accessories are available for Thomas and Betts products?
Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.
What environmental ratings do Thomas and Betts products have?
Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.
What communication protocols do Thomas and Betts products support?
Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.
What are the key features of Thomas and Betts products?
Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.
What are the main product lines offered by Thomas and Betts?
Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.
What technical support does Thomas and Betts offer?
Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.
What industries and applications are Thomas and Betts products used for?
Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.
What certifications and standards do Thomas and Betts products comply with?
Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.
What are the main product lines offered by Ocal?
Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.