ABB - Installation Products K151SR-C0240 - 15/25kV 200 Amp, Deadbreak Straight Receptacle, Bails are required, but not included, order separately. Cable Insulation Diameter 0.805 inch to 1.060 inch. Aluminum Compression Lug. Conductor Size AWG Compressed Stranded 1/0 /Solid 2/0 /mmSquared 53.49.

ABB Installation Products K151SR-C0240 15/25kV 200 Amp, Deadbreak Straight Receptacle, Bails are required, but not included…

UPC: 783786485765


Documents & Media
Installation InstructionsSpecification SheetManufacturer Product Website

Contact for Pricing

Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.

Overview

The ABB K151SR-C0240 is a 15/25kV 200 Amp Deadbreak Straight Receptacle engineered for medium-voltage cable terminations in industrial and utility applications. This deadbreak connector accommodates compressed stranded conductors ranging from 1/0 AWG to 2/0 AWG (53.49 mm²), with cable insulation diameters between 0.805 inch and 1.060 inch. The unit features an aluminum compression lug for secure, long-term electrical connections and is rated for deadbreak operation, allowing safe connection and disconnection under load without interrupting service. Designed for compatibility with industry-standard deadbreak systems, the K151SR-C0240 supports reliable performance in medium-voltage distribution systems, including switchgear, transformers, and cable terminations where 15kV or 25kV class insulation is required. The compression lug design ensures low contact resistance and mechanical integrity, reducing the risk of overheating or failure in high-current applications. Key specifications include a continuous current rating of 200 Amps, a maximum phase-to-ground operating voltage of 15.2kV (15kV class) or 26.3kV (25kV class), and a BIL (Basic Impulse Level) of 125kV. The fully shielded, fully submersible molded rubber housing is constructed from 100% peroxide-cured EPDM materials, providing corrosion resistance and environmental durability. A non-corrosive, capacitively coupled voltage test point with a removable protective cap enables safe voltage verification. The K151SR-C0240 is part of ABB’s Installation Products line and is designed to mate with compatible ABB deadbreak products, including straight plugs and tee splices. Note that required bails are not included and must be ordered separately. This product is ideal for terminating UD cable with concentric neutral and extruded insulation shielding, or other cable types when used with the appropriate ABB cable shield adapter.
  • 15/25kV voltage class with 200 Amp continuous current rating
  • Accommodates compressed stranded conductors from 1/0 AWG to 2/0 AWG (53.49 mm²)
  • Cable insulation diameter range: 0.805 inch to 1.060 inch
  • Aluminum compression lug for secure, low-resistance connections
  • Fully shielded, submersible molded rubber housing with EPDM construction
  • Non-corrosive capacitively coupled voltage test point with removable cap
  • Deadbreak operation allows safe connection/disconnection under load
  • Designed for medium-voltage switchgear, transformers, and cable terminations
  • Requires bails (ordered separately) for proper installation

Specifications

Amperage Rating
200 A
Application
Designed to connect a cable to another cable or apparatus
Color
Black
Conductor Range
1/0 STR/COMPR AWG , 2/0 SOL/COMPT AWG
Environmental Conditions
Fully Shielded, Fully Submersible
Insulation
True
Length
9.54 in
Length
242.316 mm
Material
Housing - EPDM-Rubber
Special Features
Fully shielded, fully submersible molded rubber housing. 100 percent peroxide-cured construction includes insulation and conductive EPDM materials. Provision for ground wire connection. Wide cable range with minimum number of sizes. No Test Point
Standard
ANSI/IEEE Standard 386
Temperature Rating, Maximum
149 F
Temperature Rating, Maximum
65 C
Temperature Rating, Minimum
-40 F
Temperature Rating, Minimum
-40 C
Type
Deadbreak Straight Receptacle
Voltage Rating
15 to 25 kV
Width
2.74 in
Width
69.596 mm
Package Dimensions (L x W x H)
0.01 IN x 0.01 IN x 0.01 IN
Package Dimensions (L x W x H)
0.0254 cm x 0.0254 cm x 0.0254 cm
Package Weight (Imperial)
1.0000 L
Package Weight (Metric)
0.4540 kg
25 kV, 200 Amp, Deadbreak, Elbow Connector with Test Point, Cable Insulation Diameter - .635-.905 inch. Bi-Metal Lug, Conductor Size 240 - 1/0 Stranded/Compressed or 2/0 Compact/Solid. Includes Elbow Connector Housing, Compression Lug, Probe, Probe Wrench, Bail Assembly, Tube of Lubricant, Installation Instructions, Crimp Chart and V.D. Cap-Peroxide.

252LR-B5240

25 kV, 200 Amp, Deadbreak, Elbow Connector with Test Point, Cable Insulation Diameter - .635-.905 inch. Bi-Metal Lug, Conductor Size 240 - 1/0 Stranded/Compressed or 2/0 Compact/Solid. Includes Elbow Connector Housing, Compression Lug, Probe, Probe Wrench, Bail Assembly, Tube of Lubricant, Installation Instructions, Crimp Chart and V.D. Cap-Peroxide.
200 Amp, 15/25kV, Deadbreak Elbow, Straight Receptacle, Bails are required but not included, order separately. Cable Insulation Diameter 0.890 inch to 1.220 inch. Aluminum Compression Lug. Conductor Size AWG Compressed Stranded 1/0 or Solid 2/0 or mmSquared 53.49.

K151SR-D0240

200 Amp, 15/25kV, Deadbreak Elbow, Straight Receptacle, Bails are required but not included, order separately. Cable Insulation Diameter 0.890 inch to 1.220 inch. Aluminum Compression Lug. Conductor Size AWG Compressed Stranded 1/0 or Solid 2/0 or mmSquared 53.49.
15/25kV 200 Amp, Deadbreak Straight Receptacle, Bails are required, but not included, order separately. Cable Insulation Diameter 0.635 inch to 0.905 inch. Aluminum Compression Lug. Conductor Size AWG Compressed Stranded 2/0 /Solid 3/0 /mmSquared 67.43.

K151SR-B0250

15/25kV 200 Amp, Deadbreak Straight Receptacle, Bails are required, but not included, order separately. Cable Insulation Diameter 0.635 inch to 0.905 inch. Aluminum Compression Lug. Conductor Size AWG Compressed Stranded 2/0 /Solid 3/0 /mmSquared 67.43.
15/25kV 200 Amp, Deadbreak Straight Receptacle, Bails are required, but not included, order separately. Cable Insulation Diameter 0.635 inch to 0.905 inch. Aluminum Compression Lug. Conductor Size AWG Compressed Stranded #2/Solid #1/mmSquared 33.62.

K151SR-B0220

15/25kV 200 Amp, Deadbreak Straight Receptacle, Bails are required, but not included, order separately. Cable Insulation Diameter 0.635 inch to 0.905 inch. Aluminum Compression Lug. Conductor Size AWG Compressed Stranded #2/Solid #1/mmSquared 33.62.
15/25kV 200 Amp, Deadbreak Straight Plug, Bails are required, but not included, order separately. Cable Insulation Diameter 0.805 inch to 1.060 inch. Aluminum Compression Lug. Conductor Size AWG Compressed Stranded 1/0 /Solid 2/0 /mmSquared 53.49.

K151SP-C0240

15/25kV 200 Amp, Deadbreak Straight Plug, Bails are required, but not included, order separately. Cable Insulation Diameter 0.805 inch to 1.060 inch. Aluminum Compression Lug. Conductor Size AWG Compressed Stranded 1/0 /Solid 2/0 /mmSquared 53.49.
15/25kV 200 Amp, Deadbreak Straight Plug, Bails are required, but not included, order separately. Cable Insulation Diameter 0.635 inch to 0.905 inch. Aluminum Compression Lug. Conductor Size AWG Compressed Stranded #2/Solid #1/mmSquared 33.62.

K151SP-B0220

15/25kV 200 Amp, Deadbreak Straight Plug, Bails are required, but not included, order separately. Cable Insulation Diameter 0.635 inch to 0.905 inch. Aluminum Compression Lug. Conductor Size AWG Compressed Stranded #2/Solid #1/mmSquared 33.62.
15/25kV 200 Amp, Deadbreak Straight Receptacle, Bails are required, but not included, order separately. Cable Insulation Diameter 0.635 inch to 0.905 inch. Aluminum Compression Lug. Conductor Size AWG Compressed Stranded 1/0 /Solid 2/0 /mmSquared 53.49.

K151SR-B0240

15/25kV 200 Amp, Deadbreak Straight Receptacle, Bails are required, but not included, order separately. Cable Insulation Diameter 0.635 inch to 0.905 inch. Aluminum Compression Lug. Conductor Size AWG Compressed Stranded 1/0 /Solid 2/0 /mmSquared 53.49.
15/25kV 200 Amp, Deadbreak Straight Receptacle (All Copper Lug) Cable Insulation Diameter 0.635 inch to 0.905 inch. Copper Compression Lug. Conductor Size AWG Compressed Stranded 2/0 /Solid 3/0 /mmSquared 67.43.

K151SR-B2250

15/25kV 200 Amp, Deadbreak Straight Receptacle (All Copper Lug) Cable Insulation Diameter 0.635 inch to 0.905 inch. Copper Compression Lug. Conductor Size AWG Compressed Stranded 2/0 /Solid 3/0 /mmSquared 67.43.

Frequently Asked Questions

What cable conductor sizes can the K151SR accommodate?

It can accommodate conductor sizes from No. 4 solid through 4/0 stranded.

What is the maximum phase-to-ground operating voltage for 25kV class?

For the 25kV voltage class, the maximum phase-to-ground operating voltage is 15.2kV.

What items are included in a K151SR kit?

Each kit contains a straight receptacle housing, a receptacle pin connector, a tube of lubricant, installation instructions, and a crimp chart.

Are copper compression lugs compatible with all conductors?

No, copper compression lugs are suitable for all copper conductors only.

What is the maximum phase-to-ground operating voltage for 15kV class?

For the 15kV voltage class, the maximum phase-to-ground operating voltage is 8.3kV.

What standard does the K151SR meet?

The K151SR meets ANSI/IEEE Standard 386, Latest Revision.

When can the disconnectible feature of K151SR be used?

The disconnectible feature can only be used when the circuit is de-energized for safety.

What cable insulation diameters are compatible with K151SR?

The K151SR accommodates cable insulation diameters from .575 inches through 1.220 inches.

What is the K151SR receptacle's primary function?

It is a fully shielded, submersible, separable insulated connector designed to connect a cable to another cable or apparatus.

What voltage systems is the K151SR suitable for?

The K151SR is suitable for use on both 15kV and 25kV systems.

How to Install the Elastimold 151SR/K151SR Straight Receptacle

This guide provides step-by-step instructions for preparing the cable, crimping the conductor, and installing the Elastimold 151SR/K151SR Straight Receptacle for high-voltage electrical connections.

Estimated time: 1h

Tools needed:

Wire strippers, Crimp tool, Wire brush, Rag, Measuring tape

Supplies needed:

Approved solvent, Silicone grease, Elastimold bail, #14 AWG copper wire or equivalent, Sealing material for grounding wires, Solid dielectric type cable, Mating Elastimold product (e.g., 151SP/K151SP), Elastimold insulating plug (K150DP) if required

  1. Prepare the Cable Jacket and Shield

    DANGER: All apparatus must be de-energized during installation or removal of parts. For Jacketed Concentric Neutral cable: Cut and remove the cable jacket 8 inches from the cable end. Ensure sufficient concentric neutral wires are left for grounding. For Copper Tape Shield cable: Cut and remove the cable jacket 7 1/2 inches from the cable end. Remove the copper tape shield 6 1/2 inches from the end of the cable. If using an ECS or MA grounding device, follow its specific instructions for outer jacket cut back.

  2. Prepare Cable Insulation and Conductor

    Remove 7/8 inch to 1 inch (or 1 3/4 inches to 1 7/8 inches for #1 stranded/compr. and #1/0 comp./solid aluminum cable) of cable insulation and conductive shield. Cut squarely, do not pencil. Wire brush bare aluminum conductors and immediately insert into the crimp barrel, which contains inhibitor.

  3. Crimp the Conductor Contact

    Crimp the socket terminal onto the bared conductor. Ensure the conductor remains fully seated in the connector. Refer to the crimp chart for specific instructions. Start crimps at the crimp line on the barrel and rotate each successive crimp or indent 90 degrees. If using aluminum cable, carefully wipe excess inhibitor from the contact and cable insulation.

  4. Trim Semi-Conductive Shield and Clean Insulation

    Remove the semi-conductive shield to a point 7 9/16 inches to 7 5/8 inches back from the end of the pin with a straight, smooth, squared cut. Do not cut or nick the insulation. Pencil the insulation 1/8 inch. Clean the outer jacket and thoroughly clean the insulation to remove all traces of semi-conducting residue by wiping with a rag wet with an approved solvent, always wiping from the end of the cable toward the outer jacket. If using an ECS or MA grounding device, install it following its instructions.

  5. Lubricate Cable and Receptacle

    Remove the protective cap from the straight receptacle. Keep the cable insulation and receptacle clean. Apply the supplied lubricant sparingly to the cable as shown in the diagram and to the inside of the housing. DO NOT SUBSTITUTE. Other lubricants may be harmful to this product or its mating product.

  6. Insert Cable into Receptacle

    Push the cable into the housing until the base of the pin chamfer is flush with the inside face of the receptacle. IMPORTANT: If the receptacle is not to be immediately connected, replace the protective cover. The shipping cover offers protection from dirt only and is not an insulating device. Obtain an Elastimold insulating plug (K150DP) if an insulating device is required.

  7. Connect to a Mating Plug

    Lubricate the nose of the mating plug with silicone grease. Place the nylon rod into the receptacle face until it bottoms (approximately 1 3/4 inches), ensuring it is not cut. Insert the plug assembly into the receptacle as far as possible. Pull out the nylon rod. Secure the electrical connection with an Elastimold bail. CAUTION: A bailing arrangement is required when this product is used with any mating Elastimold deadbreak product.

  8. Ground the Cable

    If an ELASTIMOLD grounding device is not being used, connect a length of #14 AWG (or equivalent) copper wire (customer supplied) through the grounding tab and twist tightly. Connect the grounding assembly of the connector to the system ground by merging it with the cable shield of each cable. Seal the grounding wires and connections to prevent corrosion.

Frequently Asked Questions about ABB - Installation Products

How are Thomas and Betts products typically installed?

Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.

What accessories are available for Thomas and Betts products?

Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.

What environmental ratings do Thomas and Betts products have?

Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.

What communication protocols do Thomas and Betts products support?

Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.

What are the key features of Thomas and Betts products?

Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.

What are the main product lines offered by Thomas and Betts?

Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.

What technical support does Thomas and Betts offer?

Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.

What industries and applications are Thomas and Betts products used for?

Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.

What certifications and standards do Thomas and Betts products comply with?

Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.

What are the main product lines offered by Ocal?

Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.