ABB - Installation Products K151SR-D0240 - 200 Amp, 15/25kV, Deadbreak Elbow, Straight Receptacle, Bails are required but not included, order separately. Cable Insulation Diameter 0.890 inch to 1.220 inch. Aluminum Compression Lug. Conductor Size AWG Compressed Stranded 1/0 or Solid 2/0 or mmSquared 53.49.

ABB Installation Products K151SR-D0240 200 Amp, 15/25kV, Deadbreak Elbow, Straight Receptacle, Bails are required but not…

UPC: 783786471287


Documents & Media
Installation InstructionsSpecification SheetManufacturer Product Website

Contact for Pricing

Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.

Overview

The ABB K151SR-D0240 is a 200 amp, 15/25kV deadbreak elbow with a straight receptacle, designed for medium-voltage cable connections in industrial and utility applications. This deadbreak elbow accommodates cable insulation diameters from 0.890 inch to 1.220 inch, making it compatible with a range of cable types. The unit features an aluminum compression lug for secure conductor termination, supporting compressed stranded conductors sized 1/0 AWG or solid conductors sized 2/0 AWG, as well as 53.49 mm² conductors. This elbow is part of ABB’s Installation Products line, known for reliable medium-voltage accessories. The deadbreak design ensures safe, insulated disconnection under load, reducing the risk of electrical faults during maintenance or reconfiguration. The straight receptacle design simplifies installation in tight spaces or where directional flexibility is limited. Note: Bail kits are required for proper installation but are not included with this elbow. Order bail kits separately to ensure full compliance with installation requirements. The K151SR-D0240 is suitable for use in switchgear, transformers, and other medium-voltage distribution equipment where deadbreak connections are specified.
  • 200 amp rated for medium-voltage applications
  • 15/25kV voltage rating for industrial and utility use
  • Straight receptacle design for simplified installation
  • Accommodates cable insulation diameters from 0.890 to 1.220 inches
  • Aluminum compression lug supports 1/0-2/0 AWG or 53.49 mm² conductors

Specifications

Amperage Rating
200 A
Application
Designed to connect a cable to another cable or apparatus
Color
Black
Conductor Range
1/0 STR/COMPR AWG , 2/0 SOL/COMPT AWG
Connection Type
Compression Lug
Current Rating
200 A
Environmental Conditions
Fully Shielded, Fully Submersible
Insulation
True
Length
9.54 in
Length
242.316 mm
Material
Aluminum
Material
Housing - EPDM-Rubber
Series
K151SR
Size
Cable Insulation Diameter 0.890 inch to 1.220 inch
Special Features
Fully shielded, fully submersible molded rubber housing. 100 percent peroxide-cured construction includes insulation and conductive EPDM materials. Provision for ground wire connection. Wide cable range with minimum number of sizes. No Test Point
Standard
ANSI/IEEE Standard 386
Temperature Rating, Maximum
149 F
Temperature Rating, Maximum
65 C
Temperature Rating, Minimum
-40 F
Temperature Rating, Minimum
-40 C
Type
Deadbreak Straight Receptacle
Voltage Rating
15 to 25 kV
Voltage Rating
15/25 kV
Width
2.74 in
Width
69.596 mm
Package Dimensions (L x W x H)
0.01 IN x 0.01 IN x 0.01 IN
Package Dimensions (L x W x H)
0.0254 cm x 0.0254 cm x 0.0254 cm
Package Weight (Imperial)
1.0000 L
Package Weight (Metric)
0.4540 kg
600 Amp, 35KV, Elbow with Insulated Plug, Cap, Stud, Lug and Cable Adapter, Cable Insulation Diameter 0.850 inch to 1.050 inch. Aluminum Compression Lug. Conductor Size AWG Compressed Stranded 1/0 /Solid 2/0 /mmSquared 53.49.

755LR-H0240

600 Amp, 35KV, Elbow with Insulated Plug, Cap, Stud, Lug and Cable Adapter, Cable Insulation Diameter 0.850 inch to 1.050 inch. Aluminum Compression Lug. Conductor Size AWG Compressed Stranded 1/0 /Solid 2/0 /mmSquared 53.49.
Single cable clamp 150-300mm2 for power terminal type 5

45000034

Single cable clamp 150-300mm2 for power terminal type 5
15/25kV 200 Amp, Deadbreak Straight Receptacle, Bails are required, but not included, order separately. Cable Insulation Diameter 0.635 inch to 0.905 inch. Aluminum Compression Lug. Conductor Size AWG Compressed Stranded 2/0 /Solid 3/0 /mmSquared 67.43.

K151SR-B0250

15/25kV 200 Amp, Deadbreak Straight Receptacle, Bails are required, but not included, order separately. Cable Insulation Diameter 0.635 inch to 0.905 inch. Aluminum Compression Lug. Conductor Size AWG Compressed Stranded 2/0 /Solid 3/0 /mmSquared 67.43.
15/25kV 200 Amp, Deadbreak Straight Receptacle, Bails are required, but not included, order separately. Cable Insulation Diameter 0.635 inch to 0.905 inch. Aluminum Compression Lug. Conductor Size AWG Compressed Stranded #2/Solid #1/mmSquared 33.62.

K151SR-B0220

15/25kV 200 Amp, Deadbreak Straight Receptacle, Bails are required, but not included, order separately. Cable Insulation Diameter 0.635 inch to 0.905 inch. Aluminum Compression Lug. Conductor Size AWG Compressed Stranded #2/Solid #1/mmSquared 33.62.
15/25kV 200 Amp, Deadbreak Straight Plug, Bails are required, but not included, order separately. Cable Insulation Diameter 0.805 inch to 1.060 inch. Aluminum Compression Lug. Conductor Size AWG Compressed Stranded 1/0 /Solid 2/0 /mmSquared 53.49.

K151SP-C0240

15/25kV 200 Amp, Deadbreak Straight Plug, Bails are required, but not included, order separately. Cable Insulation Diameter 0.805 inch to 1.060 inch. Aluminum Compression Lug. Conductor Size AWG Compressed Stranded 1/0 /Solid 2/0 /mmSquared 53.49.
15/25kV 200 Amp, Deadbreak Straight Plug, Bails are required, but not included, order separately. Cable Insulation Diameter 0.635 inch to 0.905 inch. Aluminum Compression Lug. Conductor Size AWG Compressed Stranded #2/Solid #1/mmSquared 33.62.

K151SP-B0220

15/25kV 200 Amp, Deadbreak Straight Plug, Bails are required, but not included, order separately. Cable Insulation Diameter 0.635 inch to 0.905 inch. Aluminum Compression Lug. Conductor Size AWG Compressed Stranded #2/Solid #1/mmSquared 33.62.
15/25kV 200 Amp, Deadbreak Straight Receptacle, Bails are required, but not included, order separately. Cable Insulation Diameter 0.635 inch to 0.905 inch. Aluminum Compression Lug. Conductor Size AWG Compressed Stranded 1/0 /Solid 2/0 /mmSquared 53.49.

K151SR-B0240

15/25kV 200 Amp, Deadbreak Straight Receptacle, Bails are required, but not included, order separately. Cable Insulation Diameter 0.635 inch to 0.905 inch. Aluminum Compression Lug. Conductor Size AWG Compressed Stranded 1/0 /Solid 2/0 /mmSquared 53.49.
15/25kV 200 Amp, Deadbreak Straight Receptacle (All Copper Lug) Cable Insulation Diameter 0.635 inch to 0.905 inch. Copper Compression Lug. Conductor Size AWG Compressed Stranded 2/0 /Solid 3/0 /mmSquared 67.43.

K151SR-B2250

15/25kV 200 Amp, Deadbreak Straight Receptacle (All Copper Lug) Cable Insulation Diameter 0.635 inch to 0.905 inch. Copper Compression Lug. Conductor Size AWG Compressed Stranded 2/0 /Solid 3/0 /mmSquared 67.43.

Frequently Asked Questions

Does the K151SR meet any industry standards?

Yes, the K151SR meets ANSI/IEEE Standard 386, Latest Revision.

What is the K151SR Deadbreak Straight Receptacle used for?

The K151SR connects a cable to another cable or apparatus. It is a fully shielded, fully submersible, separable insulated connector.

What are the voltage classes supported by the K151SR?

The K151SR is suitable for use on both 15kV and 25kV systems.

What is the continuous current rating for the K151SR?

The K151SR has a continuous current rating of 200 Amp for both 15kV and 25kV voltage classes.

What conductor sizes can the K151SR accommodate?

The K151SR accommodates conductor sizes from No. 4 solid through 4/0 stranded.

What cable insulation diameters are compatible with the K151SR?

The K151SR accommodates cable insulation diameters from .575 inches through 1.220 inches.

When can the disconnectible feature of the K151SR be used?

The disconnectible feature of the K151SR can only be used when the circuit is de-energized.

What is the maximum phase-to-ground operating voltage for 15kV?

For the 15kV voltage class, the maximum phase-to-ground operating voltage is 8.3kV.

What is the maximum phase-to-ground operating voltage for 25kV?

For the 25kV voltage class, the maximum phase-to-ground operating voltage is 15.2kV.

What is the BIL impulse withstand rating for the 25kV class?

For the 25kV voltage class, the BIL impulse withstand rating is 125kV.

How to Install the 151SR/K151SR Straight Receptacle

This guide provides step-by-step instructions for the safe and proper installation of the Elastimold 151SR/K151SR Straight Receptacle, designed for connecting solid dielectric type cables to other electrical apparatus. It covers cable preparation, crimping, cleaning, and final connection.

Estimated time: 1h 30m

Tools needed:

Wire strippers, Wire brush, Crimping tool, Rag, Approved solvent

Supplies needed:

Cable (solid dielectric type), Silicone grease (if connecting to mating plug), Elastimold bail (if connecting to mating plug), Mating plug assembly (if connecting), Copper wire (#14 AWG or equivalent, for grounding), Sealing material (for grounding wires), Elastimold insulating plug (K150DP, if not immediately connecting)

  1. Observe Safety and Perform Initial Checks

    DANGER: Ensure all apparatus is de-energized before installation or removal. Follow all individual user, local, and national work rules. Inspect all components for damage, correct rating, and compatibility with mating parts. This product must be installed only by competent personnel trained in high voltage electrical equipment safety practices.

  2. Prepare Cable Jacket

    For jacketed concentric neutral cable, cut and remove the cable jacket 8 inches from the cable end, ensuring sufficient concentric neutral wires for grounding. For copper tape shield cable, cut and remove the cable jacket 7 1/2 inches from the cable end, then remove the copper tape shield 6 1/2 inches from the end. Refer to ECS or MA grounding device instructions if applicable for outer jacket cut back.

  3. Prepare Conductor and Insulation

    Remove 7/8 inch to 1 inch of cable insulation and conductive shield. For #1 stranded/compressed and #1/0 compressed/solid aluminum cable, remove 1 3/4 inches to 1 7/8 inches. Wire brush bare aluminum conductors immediately and insert them into the crimp barrel, which contains inhibitor. Cut the conductor squarely; do not pencil.

  4. Crimp Socket Terminal

    Crimp the socket terminal onto the bared conductor, ensuring the conductor remains fully seated in the connector. Refer to the crimp chart provided with the contact. Start crimps at the imprinted crimp line and rotate each successive crimp or indent 90 degrees. If using aluminum cable, carefully wipe any excess inhibitor from the contact and cable insulation.

  5. Prepare Semi-Conductive Shield and Clean Insulation

    Remove the semi-conductive shield to a point 7 9/16 inches to 7 5/8 inches back from the end of the pin with a straight, smooth, squared cut, taking care not to cut or nick the insulation. Pencil the insulation 1/8 inch. Clean the outer jacket and thoroughly clean the insulation to remove all traces of semi-conducting residue by wiping with a rag wet with an approved solvent, always wiping from the cable end toward the outer jacket. Install an ECS or MA grounding device if applicable.

  6. Lubricate Receptacle and Cable

    Remove the protective cap from the straight receptacle, keeping the cable insulation and receptacle clean. Apply the supplied lubricant sparingly to the cable as shown in the instructions and to the inside of the housing. Do not substitute other lubricants, as they may harm the product or its mating product.

  7. Insert Cable into Housing

    Push the prepared cable into the housing until the base of the pin chamfer is flush with the inside face of the receptacle. IMPORTANT: If the receptacle is not to be immediately connected, replace the protective cover (which offers protection from dirt only). If an insulating device is required, obtain an Elastimold insulating plug (K150DP).

  8. Connect to Mating Plug (Optional)

    To connect to a mating plug, first lubricate the nose of the plug with silicone grease. Place the nylon rod into the receptacle face until it bottoms (approximately 1 3/4 inches), ensuring the rod is not cut. Insert the plug assembly into the receptacle as far as possible, then pull out the nylon rod. Secure the electrical connection with an Elastimold bail.

  9. Ground the Cable

    If an ELASTIMOLD grounding device is not being used, connect a length of #14 AWG (or equivalent) copper wire (customer supplied) through the grounding tab and twist tightly. Connect the grounding assembly of the connector to the system ground by merging it with the cable shield of each cable. Seal the grounding wires and connections to prevent corrosion.

Frequently Asked Questions about ABB - Installation Products

How are Thomas and Betts products typically installed?

Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.

What accessories are available for Thomas and Betts products?

Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.

What environmental ratings do Thomas and Betts products have?

Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.

What communication protocols do Thomas and Betts products support?

Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.

What are the key features of Thomas and Betts products?

Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.

What are the main product lines offered by Thomas and Betts?

Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.

What technical support does Thomas and Betts offer?

Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.

What industries and applications are Thomas and Betts products used for?

Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.

What certifications and standards do Thomas and Betts products comply with?

Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.

What are the main product lines offered by Ocal?

Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.