ABB - Installation Products K151SR-B0250 - 15/25kV 200 Amp, Deadbreak Straight Receptacle, Bails are required, but not included, order separately. Cable Insulation Diameter 0.635 inch to 0.905 inch. Aluminum Compression Lug. Conductor Size AWG Compressed Stranded 2/0 /Solid 3/0 /mmSquared 67.43.

ABB Installation Products K151SR-B0250 15/25kV 200 Amp, Deadbreak Straight Receptacle, Bails are required, but not included…

UPC: 783786486687


Documents & Media
Installation InstructionsSpecification SheetManufacturer Product Website

Contact for Pricing

Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.

Overview

The ABB K151SR-B0250 is a 15/25kV 200 Amp deadbreak straight receptacle designed for medium-voltage power distribution systems. This fully shielded, separable insulated connector provides a reliable connection point for energized systems, ensuring safety during installation and maintenance. The unit features an aluminum compression lug compatible with stranded conductors from 2/0 AWG to 3/0 AWG (67.43 mm²) or solid conductors up to 3/0 AWG, with cable insulation diameters ranging from 0.635 inches to 0.905 inches. The deadbreak design allows for safe connection and disconnection under load, reducing downtime and enhancing operational safety. The receptacle is constructed with a non-corrosive, capacitively coupled voltage test point with a removable protective cap, enabling safe voltage verification without system de-energization. The fully submersible molded rubber housing ensures durability in harsh environments, with a 100% peroxide-cured EPDM construction for long-term reliability. The K151SR-B0250 is suitable for use on both 15kV and 25kV systems, meeting ANSI/IEEE Standard 386 requirements. It accommodates UD cable with concentric neutral and extruded insulation shielding, or other cable types when used with the appropriate shield adapter. The product includes a crimp chart and installation instructions for ease of use. Note: Bails are required for operation and must be ordered separately. This receptacle is ideal for medium-voltage applications requiring a 200 Amp rating, including utility, industrial, and commercial power distribution systems.
  • 15/25kV voltage class, 200 Amp continuous current rating
  • Aluminum compression lug for stranded (2/0-3/0 AWG) or solid (up to 3/0 AWG) conductors
  • Cable insulation diameter range: 0.635 inch to 0.905 inch
  • Fully shielded, submersible molded rubber housing with capacitively coupled test point
  • Deadbreak design for safe connection/disconnection under load; bails required (sold separately)

Specifications

Amperage Rating
200 A
Application
Designed to connect a cable to another cable or apparatus
Color
Black
Conductor Range
2/0 STR/COMPR AWG , 3/0 SOL/COMPT AWG
Connection Type
Compression Lug
Current Rating
200 A
Environmental Conditions
Fully Shielded, Fully Submersible
Insulation
True
Length
9.54 in
Length
242.316 mm
Material
Housing - EPDM-Rubber
Material
Aluminum
Series
K151SR
Size
0.635"-0.905"
Special Features
Fully shielded, fully submersible molded rubber housing. 100 percent peroxide-cured construction includes insulation and conductive EPDM materials. Provision for ground wire connection. Wide cable range with minimum number of sizes. No Test Point
Standard
ANSI/IEEE Standard 386
Temperature Rating, Maximum
149 F
Temperature Rating, Maximum
65 C
Temperature Rating, Minimum
-40 F
Temperature Rating, Minimum
-40 C
Type
Deadbreak Straight Receptacle
Voltage Rating
15 to 25 kV
Voltage Rating
15/25kV
Width
2.74 in
Width
69.596 mm
Package Dimensions (L x W x H)
0.01 IN x 0.01 IN x 0.01 IN
Package Dimensions (L x W x H)
0.0254 cm x 0.0254 cm x 0.0254 cm
Package Weight (Imperial)
1.0000 L
Package Weight (Metric)
0.4540 kg
Molded Current Limiting Fuse Housing, Nominal Fuse Voltage Rating 8.3kV, Fuse Test Port - Two Capacitive Test Ports, Large Housing, Cable Insulation Diameter 0.635 inch - 0.905 inch / 16-23mm, Aluminum Conductor size 2/0 AWG Stranded/Compressed, 3/0 AWG Solid/Compact.

168FLR3B0250

Molded Current Limiting Fuse Housing, Nominal Fuse Voltage Rating 8.3kV, Fuse Test Port - Two Capacitive Test Ports, Large Housing, Cable Insulation Diameter 0.635 inch - 0.905 inch / 16-23mm, Aluminum Conductor size 2/0 AWG Stranded/Compressed, 3/0 AWG Solid/Compact.
15/25kV 200 Amp, Deadbreak Straight Receptacle, Bails are required, but not included, order separately. Cable Insulation Diameter 0.635 inch to 0.905 inch. Aluminum Compression Lug. Conductor Size AWG Compressed Stranded #2/Solid #1/mmSquared 33.62.

K151SR-B0220

15/25kV 200 Amp, Deadbreak Straight Receptacle, Bails are required, but not included, order separately. Cable Insulation Diameter 0.635 inch to 0.905 inch. Aluminum Compression Lug. Conductor Size AWG Compressed Stranded #2/Solid #1/mmSquared 33.62.
15/25kV 200 Amp, Deadbreak Straight Plug, Bails are required, but not included, order separately. Cable Insulation Diameter 0.805 inch to 1.060 inch. Aluminum Compression Lug. Conductor Size AWG Compressed Stranded 1/0 /Solid 2/0 /mmSquared 53.49.

K151SP-C0240

15/25kV 200 Amp, Deadbreak Straight Plug, Bails are required, but not included, order separately. Cable Insulation Diameter 0.805 inch to 1.060 inch. Aluminum Compression Lug. Conductor Size AWG Compressed Stranded 1/0 /Solid 2/0 /mmSquared 53.49.
15/25kV 200 Amp, Deadbreak Straight Plug, Bails are required, but not included, order separately. Cable Insulation Diameter 0.635 inch to 0.905 inch. Aluminum Compression Lug. Conductor Size AWG Compressed Stranded #2/Solid #1/mmSquared 33.62.

K151SP-B0220

15/25kV 200 Amp, Deadbreak Straight Plug, Bails are required, but not included, order separately. Cable Insulation Diameter 0.635 inch to 0.905 inch. Aluminum Compression Lug. Conductor Size AWG Compressed Stranded #2/Solid #1/mmSquared 33.62.
15/25kV 200 Amp, Deadbreak Straight Receptacle, Bails are required, but not included, order separately. Cable Insulation Diameter 0.635 inch to 0.905 inch. Aluminum Compression Lug. Conductor Size AWG Compressed Stranded 1/0 /Solid 2/0 /mmSquared 53.49.

K151SR-B0240

15/25kV 200 Amp, Deadbreak Straight Receptacle, Bails are required, but not included, order separately. Cable Insulation Diameter 0.635 inch to 0.905 inch. Aluminum Compression Lug. Conductor Size AWG Compressed Stranded 1/0 /Solid 2/0 /mmSquared 53.49.
15/25kV 200 Amp, Deadbreak Straight Receptacle (All Copper Lug) Cable Insulation Diameter 0.635 inch to 0.905 inch. Copper Compression Lug. Conductor Size AWG Compressed Stranded 2/0 /Solid 3/0 /mmSquared 67.43.

K151SR-B2250

15/25kV 200 Amp, Deadbreak Straight Receptacle (All Copper Lug) Cable Insulation Diameter 0.635 inch to 0.905 inch. Copper Compression Lug. Conductor Size AWG Compressed Stranded 2/0 /Solid 3/0 /mmSquared 67.43.
15/25kV 200 Amp, Deadbreak Straight Plug, Bails are required, but not included, order separately. Cable Insulation Diameter 0.635 inch to 0.905 inch. Aluminum Compression Lug. Conductor Size AWG Compressed Stranded 1/0 /Solid 2/0 /mmSquared 53.49.

K151SP-B0240

15/25kV 200 Amp, Deadbreak Straight Plug, Bails are required, but not included, order separately. Cable Insulation Diameter 0.635 inch to 0.905 inch. Aluminum Compression Lug. Conductor Size AWG Compressed Stranded 1/0 /Solid 2/0 /mmSquared 53.49.
Straight Plug, 200 Amp, DeadBreak, 15/25KV, Cable Insulation Diameter 0.575 inch to 0.740 inch. Aluminum Compression Lug. Conductor Size AWG Compressed Stranded 2/0 /Solid 3/0 /mmSquared 67.43.

K151SP-A0250

Straight Plug, 200 Amp, DeadBreak, 15/25KV, Cable Insulation Diameter 0.575 inch to 0.740 inch. Aluminum Compression Lug. Conductor Size AWG Compressed Stranded 2/0 /Solid 3/0 /mmSquared 67.43.

Frequently Asked Questions

What is the K151SR receptacle's primary function?

The K151SR Straight Receptacle is a fully shielded, submersible connector designed to connect a cable to another cable or apparatus. It requires an appropriate Elastimold® mating product.

What type of cable is the K151SR designed to terminate?

The K151SR is designed to terminate UD cable having concentric neutral and extruded insulation shielding. It can also terminate other types with a proper cable shield adapter.

What standard does the K151SR meet?

The K151SR meets ANSI/IEEE Standard 386, Latest Revision.

Does the K151SR have a ground wire connection?

Yes, the K151SR has a provision for ground wire connection.

What items are included in a K151SR kit?

Each kit contains a straight receptacle housing, a receptacle pin connector, a tube of lubricant, installation instructions, and a crimp chart.

What is the maximum phase-to-ground operating voltage for 15kV class?

For the 15kV voltage class, the maximum phase-to-ground operating voltage is 8.3kV.

What is the maximum phase-to-ground operating voltage for 25kV class?

For the 25kV voltage class, the maximum phase-to-ground operating voltage is 15.2kV.

When can the disconnectible feature of the K151SR be used?

The disconnectible feature of the K151SR can be used only when the circuit is de-energized.

What cable insulation diameters are compatible with the K151SR?

The K151SR accommodates cable insulation diameters from .575 inches through 1.220 inches.

What conductor sizes can the K151SR accommodate?

The K151SR can accommodate conductor sizes from No. 4 solid through 4/0 stranded.

How to Install the K151SR/K151SR Straight Receptacle

This guide provides detailed instructions for preparing cable and installing the K151SR/K151SR Straight Receptacle, designed to connect solid dielectric type cables to one another or to electrical apparatus. Ensure all apparatus are de-energized before beginning.

Estimated time: 1h 30m

Tools needed:

Cable cutters, Wire strippers, Wire brush, Crimping tool, Approved solvent, Clean rag

Supplies needed:

K151SR/K151SR Straight Receptacle, Conductor Contact (male), Nylon Venting Rod, Lubricant (supplied), Crimp Chart, Inhibitor (if using aluminum cable), Elastimold insulating plug (K150DP) (if not immediately connecting), Copper wire (#14 AWG or equivalent) (for grounding), Elastimold bail (for securing connection)

  1. Prepare for Installation and Safety Check

    Before starting, ensure all apparatus are de-energized. Inspect the package contents for completeness and damage. Verify all components fit the cable and mating products. Gather all required tools and maintain a clean work area. This product must be installed by competent personnel trained in good safety practices involving high voltage electrical equipment. Failure to follow these instructions will result in damage to the product and serious or fatal injury.

  2. Prepare the Cable Jacket (Jacketed Concentric Neutral)

    For jacketed concentric neutral cable, cut and remove 8 inches of the cable jacket from the cable end. Ensure sufficient concentric neutral wires are left for connection to the ground point as required by the installation.

  3. Prepare the Cable Jacket and Shield (Copper Tape Shield)

    For copper tape shield cable, cut and remove 7 1/2 inches of the cable jacket from the cable end. Then, remove the copper tape shield a distance of 6 1/2 inches from the end of the cable. If using an ECS or MA grounding device, follow its specific installation instructions regarding outer jacket cut back.

  4. Prepare the Conductor Insulation and Shield

    Remove 7/8 inch to 1 inch of cable insulation and conductive shield. For #1 stranded/compressed and #1/0 compressed/solid aluminum cable, remove 1 3/4 inches to 1 7/8 inches. Cut squarely, do not pencil. Wire brush bare aluminum conductors and immediately insert into the crimp barrel which contains inhibitor.

  5. Crimp the Conductor Contact

    Crimp the socket terminal onto the bared conductor, ensuring the conductor remains fully seated in the connector. Refer to the crimp chart provided with the contact. Start crimps at the crimp line imprinted on the crimp barrel and rotate each successive crimp or indent 90 degrees. If using aluminum cable, carefully wipe excess inhibitor from the contact and cable insulation.

  6. Prepare the Semi-Conductive Shield and Clean Insulation

    Remove the semi-conductive shield to a point 7 9/16 inches to 7 5/8 inches back from the end of the pin with a straight, smooth, 'squared' cut. DO NOT CUT OR NICK THE INSULATION. Pencil the insulation 1/8 inch. Clean the outer jacket and thoroughly clean the insulation to remove all traces of semi-conducting residue by wiping with a rag wet with an approved solvent. Always wipe from the end of the cable toward the outer jacket. If using an ECS or MA grounding device, install the device following its appropriate installation instructions.

  7. Lubricate and Insert Cable into Receptacle

    Remove the protective cap from the straight receptacle, keeping the cable insulation and receptacle clean. Apply the supplied lubricant sparingly to the cable as shown in the documentation and to the inside of the housing. DO NOT SUBSTITUTE, as other lubricants may be harmful to this product or its mating product. Push the cable into the housing until the base of the pin chamfer is flush with the inside face of the receptacle. If the receptacle is not to be immediately connected, replace the protective cover. Note: The shipping cover offers protection from dirt only; it is not an insulating device. If an insulating device is required, obtain an Elastimold insulating plug (K150DP).

  8. Connect to a Mating Plug (Optional)

    To connect to a mating plug: First, lubricate the nose of the plug with silicone grease. Place the nylon rod into the receptacle face until it bottoms (approximately 1 3/4 inches), taking care not to cut the rod. Insert the plug assembly into the receptacle as far as possible. Pull out the nylon rod. Secure the electrical connection with the aid of an Elastimold bail. A bailing arrangement is required when this product is used with any mating Elastimold deadbreak product.

  9. Ground the Cable

    If an ELASTIMOLD grounding device is not being used, connect a length of #14 AWG (or equivalent) copper wire (customer supplied) through the grounding tab and twist tightly as shown. Then, connect the grounding assembly of the connector to the system ground by merging with the cable shield of each cable. Seal the grounding wires and connections to prevent corrosion.

Frequently Asked Questions about ABB - Installation Products

How are Thomas and Betts products typically installed?

Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.

What accessories are available for Thomas and Betts products?

Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.

What environmental ratings do Thomas and Betts products have?

Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.

What communication protocols do Thomas and Betts products support?

Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.

What are the key features of Thomas and Betts products?

Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.

What are the main product lines offered by Thomas and Betts?

Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.

What technical support does Thomas and Betts offer?

Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.

What industries and applications are Thomas and Betts products used for?

Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.

What certifications and standards do Thomas and Betts products comply with?

Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.

What are the main product lines offered by Ocal?

Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.