
ABB Installation Products K151SR-B0240 15/25kV 200 Amp, Deadbreak Straight Receptacle, Bails are required, but not included…
UPC: 783786474080
Contact for Pricing
Minimum Qty: 30
Multiplier: 30
*Contact for lower quantities*
Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.
Overview
- 15/25kV rated deadbreak straight receptacle for medium-voltage applications
- 200 Amp continuous current rating with deadbreak design for safe load-break connections
- Accommodates cable insulation diameters from 0.635" to 0.905"
- Aluminum compression lug for 1/0 AWG compressed stranded or 2/0 AWG solid conductors (53.49 mm²)
- Bails required for installation (sold separately)
Specifications
Amperage Rating | 200 A |
Application | Designed to connect a cable to another cable or apparatus |
Color | Black |
Conductor Range | 1/0 STR/COMPR AWG , 2/0 SOL/COMPT AWG |
Connection Type | Compression Lug |
Current Rating | 200 A |
Environmental Conditions | Fully Shielded, Fully Submersible |
Insulation | True |
Length | 9.54 in |
Length | 242.316 mm |
Material | Aluminum |
Material | Housing - EPDM-Rubber |
Series | K151SR |
Size | Cable Insulation Diameter 0.635 inch to 0.905 inch |
Special Features | Fully shielded, fully submersible molded rubber housing. 100 percent peroxide-cured construction includes insulation and conductive EPDM materials. Provision for ground wire connection. Wide cable range with minimum number of sizes. No Test Point |
Standard | ANSI/IEEE Standard 386 |
Temperature Rating, Maximum | 149 F |
Temperature Rating, Maximum | 65 C |
Temperature Rating, Minimum | -40 F |
Temperature Rating, Minimum | -40 C |
Type | Deadbreak Straight Receptacle |
Voltage Rating | 15 to 25 kV |
Voltage Rating | 15/25 kV |
Width | 2.74 in |
Width | 69.596 mm |
Package Dimensions (L x W x H) | 0.01 IN x 0.01 IN x 0.01 IN |
Package Dimensions (L x W x H) | 0.0254 cm x 0.0254 cm x 0.0254 cm |
Package Weight (Imperial) | 1.0800 L |
Package Weight (Metric) | 0.4900 kg |

K655SR-J0240
600 Amp, 15/25kV, 600 Series Deadbreak Straight Receptacle with Cable Adapter, Lug and Retaining Ring. Cable Insulation Diameter 0.980 inch to 1.180 inch. Aluminum Compression Lug. Conductor Size AWG Compressed Stranded 1/0 or Compacted Solid 2/0.
K151SR-B2250
15/25kV 200 Amp, Deadbreak Straight Receptacle (All Copper Lug) Cable Insulation Diameter 0.635 inch to 0.905 inch. Copper Compression Lug. Conductor Size AWG Compressed Stranded 2/0 /Solid 3/0 /mmSquared 67.43.
K151SP-B0240
15/25kV 200 Amp, Deadbreak Straight Plug, Bails are required, but not included, order separately. Cable Insulation Diameter 0.635 inch to 0.905 inch. Aluminum Compression Lug. Conductor Size AWG Compressed Stranded 1/0 /Solid 2/0 /mmSquared 53.49.
K151SP-A0250
Straight Plug, 200 Amp, DeadBreak, 15/25KV, Cable Insulation Diameter 0.575 inch to 0.740 inch. Aluminum Compression Lug. Conductor Size AWG Compressed Stranded 2/0 /Solid 3/0 /mmSquared 67.43.
K151SP-B0250
15/25kV 200 Amp, Deadbreak Straight Plug, Bails are required, but not included, order separately. Cable Insulation Diameter 0.635 inch to 0.905 inch. Aluminum Compression Lug. Conductor Size AWG Compressed Stranded 2/0 /Solid 3/0 /mmSquared 67.43.
273RLR-J-5230
200 Amp, 25kV, Loadbreak Replacement Elbow Connector without Test Point, Repair Elbow has extended length contact and elbow housing resulting in a net gain of 8-7/8 inches in length. Includes 00400X long Bi-Metal Contact. Cable Insulation Diameter 0.980 inch to 1.180 inch. Bi-Metal Compression Lug, Conductor Size AWG Compressed Stranded #1/Solid 1/0 /mmSquared 42.41.
K151SP-B2250
15/25kV 200 Amp, Deadbreak Straight Plug Cable Insulation Diameter 0.635 inch to 0.905 inch. Copper Compression Lug. Conductor Size AWG Compressed Stranded 2/0 /Solid 3/0 /mmSquared 67.43.Frequently Asked Questions
What is the K151SR's primary function?
The K151SR Straight Receptacle is a fully shielded, fully submersible, separable insulated connector designed to connect a cable to another cable or apparatus.
What is included in a K151SR kit?
Each kit contains a straight receptacle housing, a receptacle pin connector, a tube of lubricant, installation instructions, and a crimp chart.
What cable insulation diameters are supported?
The K151SR supports cable insulation diameters from .575 inches through 1.220 inches.
When can the disconnectible feature be used?
The disconnectible feature can be used only when the circuit is de-energized.
What are the 15kV operating voltage limits?
For the 15kV voltage class, the maximum phase-to-ground operating voltage is 8.3kV, and the maximum phase-to-phase is 14.4kV.
What conductor sizes can the K151SR accommodate?
The K151SR will accommodate conductor sizes from No. 4 solid through 4/0 stranded.
What are the 25kV operating voltage limits?
For the 25kV voltage class, the maximum phase-to-ground operating voltage is 15.2kV, and the maximum phase-to-phase is 26.3kV.
What is the continuous current rating?
The continuous current rating for both 15kV and 25kV voltage classes is 200 Amp.
What voltage systems is the K151SR suitable for?
The K151SR is suitable for use on both 15kV and 25kV systems.
What is the K151SR's primary function?
The K151SR Straight Receptacle is a fully shielded, fully submersible, separable insulated connector designed to connect a cable to another cable or apparatus.
How to Install the 151SR/K151SR Straight Receptacle
This guide provides step-by-step instructions for installing the 151SR/K151SR Straight Receptacle, including cable preparation, conductor contact crimping, and mating with other Elastimold products. Ensure all apparatus are de-energized before starting.
Estimated time: 1h 30m
Tools needed:
Cable cutting tool, Wire strippers, Wire brush, Crimping tool, Rag, Approved solvent
Supplies needed:
Elastimold 151SR/K151SR Straight Receptacle, Conductor Contact (male), Nylon Venting Rod, Lubricant, Crimp Chart, Cable, Elastimold bail, Mating plug, Copper wire (#14 AWG or equivalent), Elastimold Insulating Plug (K150DP, optional)
- Prepare for Installation and Safety Checks
De-energize all apparatus before beginning installation or removal of parts. Inspect the package contents to ensure they are complete and undamaged. Verify all components fit properly with the cable and mating products. Gather all required tools and maintain cleanliness throughout the procedure. This product should only be installed by competent personnel trained in high voltage electrical equipment safety practices.
- Prepare Jacketed Concentric Neutral Cable
If using jacketed concentric neutral cable, cut and remove the cable jacket a distance of 8 inches from the cable end. Ensure sufficient concentric neutral wires are allowed for connecting to the ground point as required by the installation.
- Prepare Copper Tape Shield Cable
If using copper tape shield cable, cut and remove the cable jacket a distance of 7 1/2 inches from the cable end. Remove the copper tape shield a distance of 6 1/2 inches from the end of the cable. (Note: If using an ECS or MA grounding device, follow its specific instructions for outer jacket cut back.)
- Prepare Cable Insulation and Conductor
Remove 7/8 to 1 inch (or 1 3/4 to 1 7/8 inches for #1 stranded/compressed and #1/0 compressed/solid aluminum cable) of cable insulation and conductive shield. Cut the cable squarely; do not pencil the cut. Wire brush any bare aluminum conductors and immediately insert them into the crimp barrel, which contains inhibitor.
- Crimp Conductor Contact
Crimp the socket terminal onto the bared conductor, ensuring the conductor remains fully seated in the connector. Refer to the crimp chart provided with the contact. Start the crimps at the crimp line imprinted on the crimp barrel and rotate each successive crimp or indent 90 degrees. If using aluminum cable, carefully wipe any excess inhibitor from the contact and cable insulation.
- Prepare Semi-Conductive Shield and Clean Insulation
Remove the semi-conductive shield to a point 7 9/16 to 7 5/8 inches back from the end of the pin with a straight, smooth, 'squared' cut. Do not cut or nick the insulation. Pencil the insulation 1/8 inch. Clean the outer jacket and thoroughly clean the insulation to remove all traces of semi-conducting residue by wiping with a rag wet with an approved solvent, always wiping from the end of the cable toward the outer jacket. If using an ECS or MA grounding device, install it following its appropriate instructions.
- Lubricate Receptacle and Cable
Remove the protective cap from the straight receptacle. Keep the cable insulation and receptacle clean. Apply the supplied lubricant sparingly to the cable as shown in the documentation and to the inside of the housing. Do not substitute other lubricants, as they may be harmful to this product or its mating product.
- Insert Cable into Receptacle
Push the cable into the housing until the base of the pin chamfer is flush with the inside face of the receptacle. If the receptacle is not to be immediately connected, replace the protective cover. Note that the shipping cover offers protection from dirt only and is not an insulating device; if an insulating device is required, obtain an Elastimold insulating plug (K150DP).
- Connect to Mating Plug
Lubricate the nose of the mating plug with silicone grease. Place the nylon rod into the receptacle face until it bottoms (approximately 1 3/4 inches), taking care to ensure the nylon rod is not cut while mating parts. Insert the plug assembly into the receptacle as far as possible. Pull out the nylon rod. Secure the electrical connection with the aid of an Elastimold bail; a bailing arrangement is required when this product is used with any mating Elastimold deadbreak product.
- Ground the Cable
If an Elastimold grounding device is not being used, connect a length of #14 AWG (or equivalent) copper wire (customer supplied) through the grounding tab and twist tightly. Connect the grounding assembly of the connector to the system ground by merging it with the cable shield of each cable. Seal the grounding wires and connections to prevent corrosion.
Frequently Asked Questions about ABB - Installation Products
How are Thomas and Betts products typically installed?
Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.
What accessories are available for Thomas and Betts products?
Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.
What environmental ratings do Thomas and Betts products have?
Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.
What communication protocols do Thomas and Betts products support?
Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.
What are the key features of Thomas and Betts products?
Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.
What are the main product lines offered by Thomas and Betts?
Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.
What technical support does Thomas and Betts offer?
Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.
What industries and applications are Thomas and Betts products used for?
Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.
What certifications and standards do Thomas and Betts products comply with?
Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.
What are the main product lines offered by Ocal?
Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.
