ABB - Installation Products K151SP-D0240 - 200 Amp, 15/25kV, Deadbreak Elbow, Straight Plug, Bails are required but not included, order separately. Cable Insulation Diameter 0.890 inch to 1.220 inch. Aluminum Compression Lug. Conductor Size AWG Compressed Stranded 1/0 /Solid 2/0 /mmSquared 53.49.

ABB Installation Products K151SP-D0240 200 Amp, 15/25kV, Deadbreak Elbow, Straight Plug, Bails are required but not included…

UPC: 783786471270


Documents & Media
Installation InstructionsSpecification SheetManufacturer Product Website

Contact for Pricing

Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.

Overview

The ABB K151SP-D0240 is a 200 Amp, 15/25 kV deadbreak elbow connector designed for reliable power distribution. This straight plug configuration features an aluminum compression lug, suitable for conductor sizes ranging from AWG 1/0 compressed stranded to AWG 2/0 solid (53.49 mm²). The connector accommodates cable insulation diameters between 0.890 inches and 1.220 inches, ensuring a secure fit for a variety of cable types. Engineered by ABB Installation Products, this deadbreak elbow is a critical component for connecting underground power cables to transformers, switchgear, and other electrical apparatus. Its deadbreak design ensures a fully shielded and submersible connection, providing enhanced safety and operational integrity in demanding utility and industrial environments. Please note that bails are required for proper installation and must be ordered separately. The K151SP series offers robust performance for medium-voltage applications. Key specifications include: Voltage Rating: 15/25 kV, Current Rating: 200 A, Connection Type: Deadbreak Elbow, Straight Plug, Material: Aluminum (Compression Lug), Cable Insulation Diameter Range: 0.890" - 1.220", Conductor Size Compatibility: AWG 1/0 (Stranded Compressed) / 2/0 (Solid) / 53.49 mm² (Compressed).
  • 200 Amp current rating
  • 15/25 kV voltage rating
  • Deadbreak elbow, straight plug configuration
  • Aluminum compression lug
  • Accommodates cable insulation diameters from 0.890" to 1.220"

Specifications

Amperage Rating
200 A
Application
Designed to Terminate UD Cable having Concentric Neutral and Extruded instalation shielding
Color
Black
Conductor Range
1/0 STR/COMPR AWG , 2/0 SOL/COMPT AWG
Environmental Conditions
Fully Shielded, Fully Submersible
Insulation
True
Length
8.81 in
Length
223.774 mm
Material
Housing - EPDM-Rubber
Special Features
Fully shielded, fully submersible molded rubber housing. 100 percent peroxide-cured construction includes insulation and conductive EPDM materials. Provision for ground wire connection. Wide cable range with minimum number of sizes. No Test Point
Standard
ANSI/IEEE Standard 386
Temperature Rating, Maximum
149 F
Temperature Rating, Maximum
65 C
Temperature Rating, Minimum
-40 F
Temperature Rating, Minimum
-40 C
Type
Deadbreak Straight Plug
Voltage Rating
15 to 25 kV
Width
2.55 in
Width
64.77 mm
Package Dimensions (L x W x H)
0.01 IN x 0.01 IN x 0.01 IN
Package Dimensions (L x W x H)
0.0254 cm x 0.0254 cm x 0.0254 cm
Package Weight (Imperial)
1.0000 L
Package Weight (Metric)
0.4540 kg
25kV 200 Amp, Loadbreak Elbow Connector with Test Point, .890 inch - 1.220 Inch Cable Insulation Diameter, Wire Size 1/0 Stranded or 2/0 Solid. Bi-Metal Compression Lug.

262LR-D5240

25kV 200 Amp, Loadbreak Elbow Connector with Test Point, .890 inch - 1.220 Inch Cable Insulation Diameter, Wire Size 1/0 Stranded or 2/0 Solid. Bi-Metal Compression Lug.
Straight Plug, 200 Amp, DeadBreak, 15/25KV, Cable Insulation Diameter 0.635 inch to 0.905 inch. Aluminum Compression Lug. Conductor Size AWG Compressed Solid #4/mmSquared 16.76.

K151SP-B0190

Straight Plug, 200 Amp, DeadBreak, 15/25KV, Cable Insulation Diameter 0.635 inch to 0.905 inch. Aluminum Compression Lug. Conductor Size AWG Compressed Solid #4/mmSquared 16.76.
Straight Receptacle, 200 Amp, DeadBreak, 15/25KV, Cable Insulation Diameter 0.635 inch to 0.905 inch. Aluminum Compression Lug. Conductor Size AWG Compressed Solid #4 or mmSquared 16.76.

K151SR-B0190

Straight Receptacle, 200 Amp, DeadBreak, 15/25KV, Cable Insulation Diameter 0.635 inch to 0.905 inch. Aluminum Compression Lug. Conductor Size AWG Compressed Solid #4 or mmSquared 16.76.
15/25kV 200 Amp, Deadbreak Straight Receptacle, Bails are required, but not included, order separately. Cable Insulation Diameter 0.805 inch to 1.060 inch. Aluminum Compression Lug. Conductor Size AWG Compressed Stranded 1/0 /Solid 2/0 /mmSquared 53.49.

K151SR-C0240

15/25kV 200 Amp, Deadbreak Straight Receptacle, Bails are required, but not included, order separately. Cable Insulation Diameter 0.805 inch to 1.060 inch. Aluminum Compression Lug. Conductor Size AWG Compressed Stranded 1/0 /Solid 2/0 /mmSquared 53.49.
200 Amp, 15/25kV, Deadbreak Elbow, Straight Receptacle, Bails are required but not included, order separately. Cable Insulation Diameter 0.890 inch to 1.220 inch. Aluminum Compression Lug. Conductor Size AWG Compressed Stranded 1/0 or Solid 2/0 or mmSquared 53.49.

K151SR-D0240

200 Amp, 15/25kV, Deadbreak Elbow, Straight Receptacle, Bails are required but not included, order separately. Cable Insulation Diameter 0.890 inch to 1.220 inch. Aluminum Compression Lug. Conductor Size AWG Compressed Stranded 1/0 or Solid 2/0 or mmSquared 53.49.
15/25kV 200 Amp, Deadbreak Straight Receptacle, Bails are required, but not included, order separately. Cable Insulation Diameter 0.635 inch to 0.905 inch. Aluminum Compression Lug. Conductor Size AWG Compressed Stranded 2/0 /Solid 3/0 /mmSquared 67.43.

K151SR-B0250

15/25kV 200 Amp, Deadbreak Straight Receptacle, Bails are required, but not included, order separately. Cable Insulation Diameter 0.635 inch to 0.905 inch. Aluminum Compression Lug. Conductor Size AWG Compressed Stranded 2/0 /Solid 3/0 /mmSquared 67.43.
15/25kV 200 Amp, Deadbreak Straight Receptacle, Bails are required, but not included, order separately. Cable Insulation Diameter 0.635 inch to 0.905 inch. Aluminum Compression Lug. Conductor Size AWG Compressed Stranded #2/Solid #1/mmSquared 33.62.

K151SR-B0220

15/25kV 200 Amp, Deadbreak Straight Receptacle, Bails are required, but not included, order separately. Cable Insulation Diameter 0.635 inch to 0.905 inch. Aluminum Compression Lug. Conductor Size AWG Compressed Stranded #2/Solid #1/mmSquared 33.62.
15/25kV 200 Amp, Deadbreak Straight Plug, Bails are required, but not included, order separately. Cable Insulation Diameter 0.805 inch to 1.060 inch. Aluminum Compression Lug. Conductor Size AWG Compressed Stranded 1/0 /Solid 2/0 /mmSquared 53.49.

K151SP-C0240

15/25kV 200 Amp, Deadbreak Straight Plug, Bails are required, but not included, order separately. Cable Insulation Diameter 0.805 inch to 1.060 inch. Aluminum Compression Lug. Conductor Size AWG Compressed Stranded 1/0 /Solid 2/0 /mmSquared 53.49.

Frequently Asked Questions

Does the K151SP meet industry standards?

Yes, the K151SP meets ANSI/IEEE Standard 386, Latest Revision.

What type of product is the K151SP?

The K151SP is a 15/25kV, 200 Amp Deadbreak Straight Plug. It features a fully shielded, fully submersible molded rubber housing.

What cable types are compatible with the K151SP?

It is designed for UD cable with concentric neutral and extruded insulation shielding. It can also terminate other cable types using a proper Elastimold® cable shield adapter.

What conductor sizes does the K151SP accommodate?

The K151SP accommodates conductor sizes from No. 4 solid through 4/0 stranded.

What cable insulation diameters does the K151SP support?

The K151SP accommodates cable insulation diameters ranging from .575 inches to 1.220 inches.

What Elastimold products can the K151SP mate with?

The K151SP is designed to mate with Elastimold® K151T tee splice and K151SR straight receptacle products.

What are the 15kV operating voltage ratings?

For 15kV, the maximum phase-to-ground operating voltage is 8.3kV, and the maximum phase-to-phase is 14.4kV.

What are the 25kV operating voltage ratings?

For 25kV, the maximum phase-to-ground operating voltage is 15.2kV, and the maximum phase-to-phase is 26.3kV.

What is the continuous current rating for the K151SP?

The continuous current rating for the K151SP is 200 Amp for both 15kV and 25kV voltage classes.

What is the momentary current rating for the K151SP?

The momentary current rating for the K151SP is 10kA Symmetrical for 10 Cycles for both 15kV and 25kV voltage classes.

How to Install the K151SP Straight Plug

This guide provides step-by-step instructions for installing the K151SP Straight Plug, designed to connect solid dielectric type cables to one another or to electrical apparatus on 15kV and 25kV class systems. A bailing arrangement is required when used with any mating Elastimold deadbreak product.

Estimated time: 1h 30m

Tools needed:

Cable cutting tool, Wire strippers, Wire brush, Crimping tool, Rag, Approved solvent

Supplies needed:

K151SP Straight Plug, Conductor Contact (female), Nylon Venting Rod, Lubricant (supplied with product), Crimp Chart, Plastic Pin, Silicone grease, ELASTIMOLD bail, #14 AWG or equivalent copper wire (customer supplied), HV insulated cap(s) or connector(s) (if product supplied with shipping covers)

  1. Pre-installation Safety Checks

    Before starting, de-energize all apparatus. Install and operate in accordance with user, local, and national work rules. Do not touch or move energized products. Inspect all parts for damage, rating, and compatibility. This product must be installed only by competent personnel trained in high voltage electrical equipment safety practices. If supplied with protective shipping covers, remove them and replace with appropriate HV insulated caps or connectors before submerging or energizing.

  2. Prepare Cable Jacket and Shield

    For Jacketed Concentric Neutral cable, cut and remove the cable jacket 8 inches from the end, ensuring sufficient neutral wires for grounding. For Copper Tape Shield cable, cut and remove the cable jacket 7-1/2 inches from the end, then remove the copper tape shield 6-1/2 inches from the cable end. If using an ECS or MA grounding device, follow its specific instructions for outer jacket cut back.

  3. Prepare Conductor Insulation and Crimp Terminal

    Remove 7/8 to 1 inch (or 1-3/4 to 1-7/8 inches for #1 stranded/compr. and #1/0 compt./solid aluminum cable) of cable insulation and conductive shield. Cut squarely, do not pencil. Wire brush bare aluminum conductors and immediately insert into the crimp barrel containing inhibitor. Crimp the socket terminal onto the bared conductor, holding the crimp barrel against the cable insulation. Refer to the crimp chart. Start crimps at the crimp line and rotate each successive crimp 90 degrees. Wipe excess inhibitor from the contact and insulation.

  4. Prepare Semi-Conductive Shield and Clean Insulation

    Temporarily remove the plastic pin. Remove the semi-conductive shield to a point 7-3/4 to 7-13/16 inches back from the end of the socket with a straight, smooth, 'squared' cut; do not cut or nick the insulation. Replace the plastic pin. Pencil the insulation 1/8 inch. Clean the outer jacket and thoroughly clean the insulation with an approved solvent, wiping from the cable end toward the outer jacket. If using an ECS or MA grounding device, install it now following its instructions.

  5. Lubricate Cable and Position Collar

    Slide the collar, smaller end first, onto each cable. Keep cable insulation and plug clean. Apply the supplied lubricant sparingly to the cable as shown and to the inside of the housing. Do not substitute lubricants, as other types may be harmful to this product or its mating product. Refer to the bailing instruction sheet.

  6. Install Cable into Housing

    Push the cable into the housing. Ensure the leading edge of the socket contact is flush with the front edge of the plug. Remove the plastic pin from the socket and discard it.

  7. Connect to Mating Receptacle

    Lubricate the nose of the plug with silicone grease. Place the nylon rod into the receptacle face until it bottoms (approximately 1-3/4 inches), taking care not to cut the rod. Insert the plug assembly into the receptacle as far as possible. Pull out the nylon rod. Secure the electrical connection with an ELASTIMOLD bail, referencing the Bailing Instruction Sheet (150TB-4).

  8. Connect Grounding (Optional)

    If an ELASTIMOLD grounding device is not being used, connect a length of #14 AWG or equivalent copper wire (customer supplied) through the grounding tab and twist tightly. Then connect the grounding assembly of the connector to the system ground by merging with the cable shield of each cable. Seal the grounding wires and connections to prevent corrosion.

Frequently Asked Questions about ABB - Installation Products

How are Thomas and Betts products typically installed?

Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.

What accessories are available for Thomas and Betts products?

Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.

What environmental ratings do Thomas and Betts products have?

Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.

What communication protocols do Thomas and Betts products support?

Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.

What are the key features of Thomas and Betts products?

Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.

What are the main product lines offered by Thomas and Betts?

Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.

What technical support does Thomas and Betts offer?

Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.

What industries and applications are Thomas and Betts products used for?

Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.

What certifications and standards do Thomas and Betts products comply with?

Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.

What are the main product lines offered by Ocal?

Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.