ABB - Installation Products K151SP-D0220 - 200 Amp, 15/25kV, Deadbreak Elbow, Straight Plug, Bails are required but not included, order separately. Cable Insulation Diameter 0.890 inch to 1.220 inch. Aluminum Compression Lug. Conductor Size AWG Compressed Stranded #2/Solid #1/mmSquared 33.62.

ABB Installation Products K151SP-D0220 200 Amp, 15/25kV, Deadbreak Elbow, Straight Plug, Bails are required but not included…

UPC: 783786471263


Documents & Media
Installation InstructionsSpecification SheetManufacturer Product Website

Contact for Pricing

Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.

Overview

The ABB K151SP-D0220 is a 200 Amp, 15/25kV deadbreak elbow connector engineered for reliable medium-voltage cable terminations in underground distribution systems. This straight plug configuration accommodates cable insulation diameters from 0.890 inch to 1.220 inch, making it compatible with conductor sizes including #2 AWG compressed stranded and solid #1 AWG (33.62 mm² equivalent). The unit features an aluminum compression lug for secure, low-resistance connections and is rated for deadbreak operation, enabling safe connection and disconnection under load conditions without de-energizing the system. Designed for utility substations, industrial power systems, and commercial facilities, the K151SP-D0220 meets ANSI/IEEE Standard 386 for separable insulated connectors. It supports 15kV and 25kV voltage classes with phase-to-ground operating voltages up to 8.3kV (15kV class) and 15.2kV (25kV class), respectively. The connector delivers 200 Amp continuous current with 10kA symmetrical momentary ratings for 10 cycles. Impulse withstand ratings are 95kV BIL (15kV class) and 125kV BIL (25kV class), ensuring robust protection against transient events. The fully shielded, fully submersible molded rubber housing is constructed with 100% peroxide-cured EPDM materials for long-term durability in harsh environments. A provision for ground wire connection enhances safety, while the wide cable range minimizes the need for multiple size-specific components. The K151SP-D0220 is compatible with Elastimold® accessories such as the K151T tee splice and K151SR straight receptacle, providing flexible system integration. Note that bail hardware is required for installation and must be ordered separately to match system requirements.
  • 200 Amp continuous current rating with 10kA momentary withstand
  • Supports 15kV and 25kV voltage classes per ANSI/IEEE 386
  • Accommodates cable insulation diameters from 0.890" to 1.220"
  • Fully shielded, submersible molded rubber housing with EPDM construction
  • Aluminum compression lug for secure, low-resistance connections

Specifications

Amperage Rating
200 A
Application
Designed to Terminate UD Cable having Concentric Neutral and Extruded instalation shielding
Color
Black
Conductor Range
#2 STR/COMPR AWG , #1 SOL/COMPT AWG
Environmental Conditions
Fully Shielded, Fully Submersible
Insulation
True
Length
8.81 in
Length
223.774 mm
Material
Housing - EPDM-Rubber
Special Features
Fully shielded, fully submersible molded rubber housing. 100 percent peroxide-cured construction includes insulation and conductive EPDM materials. Provision for ground wire connection. Wide cable range with minimum number of sizes. No Test Point
Standard
ANSI/IEEE Standard 386
Temperature Rating, Maximum
149 F
Temperature Rating, Maximum
65 C
Temperature Rating, Minimum
-40 F
Temperature Rating, Minimum
-40 C
Type
Deadbreak Straight Plug
Voltage Rating
15 to 25 kV
Width
2.55 in
Width
64.77 mm
Package Dimensions (L x W x H)
0.01 IN x 0.01 IN x 0.01 IN
Package Dimensions (L x W x H)
0.0254 cm x 0.0254 cm x 0.0254 cm
Package Weight (Imperial)
1.0000 L
Package Weight (Metric)
0.4540 kg
Molded Current Limiting Fuse Housing, Nominal Fuse Voltage Rating 8.3kV, Fuse Test Port - Two Capacitive Test Ports, Small Housing, Cable Insulation Diameter 0.635 inch - 0.905 inch / 16-23mm, Bi-Metal Conductor size 2 AWG Stranded/Compressed, 1 AWG Solid/Compact. no Sealing Kit

168FLR1-B5220

Molded Current Limiting Fuse Housing, Nominal Fuse Voltage Rating 8.3kV, Fuse Test Port - Two Capacitive Test Ports, Small Housing, Cable Insulation Diameter 0.635 inch - 0.905 inch / 16-23mm, Bi-Metal Conductor size 2 AWG Stranded/Compressed, 1 AWG Solid/Compact. no Sealing Kit
200 Amp, 15/25kV, Deadbreak Elbow, Straight Plug, Bails are required but not included, order separately. Cable Insulation Diameter 0.890 inch to 1.220 inch. Aluminum Compression Lug. Conductor Size AWG Compressed Stranded 1/0 /Solid 2/0 /mmSquared 53.49.

K151SP-D0240

200 Amp, 15/25kV, Deadbreak Elbow, Straight Plug, Bails are required but not included, order separately. Cable Insulation Diameter 0.890 inch to 1.220 inch. Aluminum Compression Lug. Conductor Size AWG Compressed Stranded 1/0 /Solid 2/0 /mmSquared 53.49.
Straight Plug, 200 Amp, DeadBreak, 15/25KV, Cable Insulation Diameter 0.635 inch to 0.905 inch. Aluminum Compression Lug. Conductor Size AWG Compressed Solid #4/mmSquared 16.76.

K151SP-B0190

Straight Plug, 200 Amp, DeadBreak, 15/25KV, Cable Insulation Diameter 0.635 inch to 0.905 inch. Aluminum Compression Lug. Conductor Size AWG Compressed Solid #4/mmSquared 16.76.
Straight Receptacle, 200 Amp, DeadBreak, 15/25KV, Cable Insulation Diameter 0.635 inch to 0.905 inch. Aluminum Compression Lug. Conductor Size AWG Compressed Solid #4 or mmSquared 16.76.

K151SR-B0190

Straight Receptacle, 200 Amp, DeadBreak, 15/25KV, Cable Insulation Diameter 0.635 inch to 0.905 inch. Aluminum Compression Lug. Conductor Size AWG Compressed Solid #4 or mmSquared 16.76.
15/25kV 200 Amp, Deadbreak Straight Receptacle, Bails are required, but not included, order separately. Cable Insulation Diameter 0.805 inch to 1.060 inch. Aluminum Compression Lug. Conductor Size AWG Compressed Stranded 1/0 /Solid 2/0 /mmSquared 53.49.

K151SR-C0240

15/25kV 200 Amp, Deadbreak Straight Receptacle, Bails are required, but not included, order separately. Cable Insulation Diameter 0.805 inch to 1.060 inch. Aluminum Compression Lug. Conductor Size AWG Compressed Stranded 1/0 /Solid 2/0 /mmSquared 53.49.
200 Amp, 15/25kV, Deadbreak Elbow, Straight Receptacle, Bails are required but not included, order separately. Cable Insulation Diameter 0.890 inch to 1.220 inch. Aluminum Compression Lug. Conductor Size AWG Compressed Stranded 1/0 or Solid 2/0 or mmSquared 53.49.

K151SR-D0240

200 Amp, 15/25kV, Deadbreak Elbow, Straight Receptacle, Bails are required but not included, order separately. Cable Insulation Diameter 0.890 inch to 1.220 inch. Aluminum Compression Lug. Conductor Size AWG Compressed Stranded 1/0 or Solid 2/0 or mmSquared 53.49.
15/25kV 200 Amp, Deadbreak Straight Receptacle, Bails are required, but not included, order separately. Cable Insulation Diameter 0.635 inch to 0.905 inch. Aluminum Compression Lug. Conductor Size AWG Compressed Stranded 2/0 /Solid 3/0 /mmSquared 67.43.

K151SR-B0250

15/25kV 200 Amp, Deadbreak Straight Receptacle, Bails are required, but not included, order separately. Cable Insulation Diameter 0.635 inch to 0.905 inch. Aluminum Compression Lug. Conductor Size AWG Compressed Stranded 2/0 /Solid 3/0 /mmSquared 67.43.
15/25kV 200 Amp, Deadbreak Straight Receptacle, Bails are required, but not included, order separately. Cable Insulation Diameter 0.635 inch to 0.905 inch. Aluminum Compression Lug. Conductor Size AWG Compressed Stranded #2/Solid #1/mmSquared 33.62.

K151SR-B0220

15/25kV 200 Amp, Deadbreak Straight Receptacle, Bails are required, but not included, order separately. Cable Insulation Diameter 0.635 inch to 0.905 inch. Aluminum Compression Lug. Conductor Size AWG Compressed Stranded #2/Solid #1/mmSquared 33.62.

Frequently Asked Questions

What type of cable is the K151SP designed to terminate?

The K151SP is designed to terminate UD cable with concentric neutral and extruded insulation shielding. It can also terminate other cable types with a proper Elastimold cable shield adapter.

What is the BIL impulse withstand for the 25kV voltage class?

For the 25kV voltage class, the BIL impulse withstand is 125kV.

What is the momentary current rating of the K151SP?

The momentary current rating for the K151SP is 10kA Symmetrical for 10 Cycles, applicable to both 15kV and 25kV classes.

What is the BIL impulse withstand for the 15kV voltage class?

For the 15kV voltage class, the BIL impulse withstand is 95kV.

Which Elastimold products are compatible with the K151SP?

The K151SP is designed to mate with the Elastimold K151T tee splice and the K151SR straight receptacle.

What is the maximum phase-to-ground operating voltage for 15kV class?

For the 15kV voltage class, the maximum phase-to-ground operating voltage is 8.3kV.

What is the maximum phase-to-ground operating voltage for 25kV class?

For the 25kV voltage class, the maximum phase-to-ground operating voltage is 15.2kV.

What cable insulation diameters does the K151SP support?

The K151SP supports cable insulation diameters ranging from .575 inches to 1.220 inches.

What conductor sizes can the K151SP accommodate?

The K151SP can accommodate conductor sizes from No. 4 solid through 4/0 stranded.

What is the K151SP deadbreak straight plug's voltage and current rating?

The K151SP deadbreak straight plug is rated for 15/25kV voltage class and has a continuous current rating of 200 Amps.

How to Install the K151SP Straight Plug

This guide provides instructions for installing the K151SP Straight Plug, designed to connect solid dielectric type cables to other ELASTIMOLD products on 15kV and 25kV class systems. Ensure all apparatus are de-energized before beginning installation.

Estimated time: 1h 30m

Tools needed:

Wire strippers, Wire brush, Crimp tool, Rag, Approved solvent

Supplies needed:

Conductor Contact (female), Nylon Venting Rod, Lubricant, Inhibitor, ELASTIMOLD bail, Copper wire (#14 AWG or equivalent)

  1. Prepare Cable Jacket and Shield

    For Jacketed Concentric Neutral cable, cut and remove the cable jacket 8 inches from the cable end, ensuring sufficient concentric neutral wires for grounding. For Copper Tape Shield cable, cut and remove the cable jacket 7-1/2 inches from the cable end, then remove the copper tape shield 6-1/2 inches from the end of the cable. Note: If using an ECS or MA grounding device, follow its specific instructions for outer jacket cut back.

  2. Prepare Cable Insulation and Conductor

    Remove 7/8 to 1 inch (or 1-3/4 to 1-7/8 inches for #1 stranded/compressed and #1/0 compressed/solid aluminum cable) of cable insulation and conductive shield. Cut squarely, do not pencil. Wire brush bare aluminum conductors immediately and insert into the crimp barrel which contains inhibitor.

  3. Crimp Socket Terminal

    Crimp the socket terminal onto the bared conductor, holding the crimp barrel against the cable insulation. Refer to the crimp chart provided with the contact. Start crimps at the crimp line imprinted on the barrel and rotate each successive crimp or indent 90 degrees. Carefully wipe any excess inhibitor from the contact and cable insulation.

  4. Prepare Semi-Conductive Shield and Clean Insulation

    Temporarily remove the plastic pin. Remove the semi-conductive shield to a point 7-3/4 to 7-13/16 inches back from the end of the socket with a straight, smooth, squared cut, ensuring not to cut or nick the insulation. Replace the plastic pin. Pencil the insulation 1/8 inch. Clean the outer jacket and thoroughly clean the insulation with an approved solvent to remove all traces of semi-conducting residue, wiping from the cable end toward the outer jacket. If using an ECS or MA grounding device, install it now following its instructions.

  5. Lubricate Cable and Collar

    Slide the collar, smaller end first, onto each cable. Refer to the bailing instruction sheet. Keep the cable insulation and plug clean. Apply the supplied lubricant sparingly to the cable as shown and to the inside of the housing. DO NOT SUBSTITUTE other lubricants, as they may be harmful to the product.

  6. Install Cable into Housing

    Push the cable into the housing until the leading edge of the socket contact is flush with the front edge of the plug. Remove the plastic pin from the socket and discard it.

  7. Connect to Mating Receptacle

    Lubricate the nose of the plug with silicone grease. Place the nylon rod into the receptacle face until it bottoms (approximately 1-3/4 inches), taking care not to cut the rod. Insert the plug assembly into the receptacle as far as possible. Pull out the nylon rod. Secure the electrical connection with an ELASTIMOLD bail, referencing the Bailing Instruction Sheet (150TB-4).

  8. Connect Grounding Device

    If an ELASTIMOLD grounding device is not being used, connect a customer-supplied length of #14 AWG (or equivalent) copper wire through the grounding tab and twist tightly. Connect the grounding assembly of the connector to the system ground by merging it with the cable shield of each cable. Seal the grounding wires and connections to prevent corrosion.

Frequently Asked Questions about ABB - Installation Products

How are Thomas and Betts products typically installed?

Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.

What accessories are available for Thomas and Betts products?

Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.

What environmental ratings do Thomas and Betts products have?

Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.

What communication protocols do Thomas and Betts products support?

Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.

What are the key features of Thomas and Betts products?

Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.

What are the main product lines offered by Thomas and Betts?

Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.

What technical support does Thomas and Betts offer?

Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.

What industries and applications are Thomas and Betts products used for?

Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.

What certifications and standards do Thomas and Betts products comply with?

Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.

What are the main product lines offered by Ocal?

Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.