ABB - Installation Products 69TCJS45147P55MDANB - 69 kv, Transmission Cable Joint, Housing Type - Shieldbreak, Housing Style 4, Housing Size 5, Connector type Aluminum. Connector Code 47P - Conductor Diameter Range - 1.378-1.425 inch (35.00-36.19mm), Heatsink Size 55 - Outside Diameter 3.000 inch, Heatsink Bore - M - 1.468 inch. Type Shield - D - Copper Tape and Neutral Wire, Metallic Screen Continuity Kit - A - 4/0 Bonding Cable 6 foot quantity 1 with Split Bolts quantity 4, Armor Kit - N - not required, Outer Jacket Restoration Kit - B - Heat Shrink standard package
ABB - Installation Products

69TCJS45147P55MDANB

UPC: 075114245012


Documents & Media
Specification SheetManufacturer Product Website

Contact for Pricing

Overview

This ABB Transmission Cable Joint, SKU 69TCJS45147P55MDANB, is engineered for reliable 69 kV applications. It features a Shieldbreak housing type, specifically Housing Style 4 and Housing Size 5, ensuring robust protection for critical transmission infrastructure. The connector is constructed from high-grade aluminum, with Connector Code 47P, designed to accommodate a conductor diameter range of 1.378-1.425 inches (35.00-36.19mm). The integrated heatsink, Size 55, boasts an outside diameter of 3.000 inches and a heatsink bore of 1.468 inches (M), facilitating efficient thermal management. This joint system includes a Type D shield, utilizing copper tape and neutral wire for effective metallic screen continuity. The Metallic Screen Continuity Kit (A) comes with a 4/0 bonding cable, 6 feet in length, and four split bolts for secure connections. An Armor Kit (N) is not required for this configuration. The Outer Jacket Restoration Kit (B) utilizes standard heat shrink for a durable and weather-resistant seal. This product is part of ABB's Transmission Cable Joint series, designed for demanding electrical distribution and transmission networks. Its precise specifications ensure optimal performance and longevity in high-voltage environments. UNSPSC Code: 39121452.
  • 69 kV Voltage Rating for high-voltage transmission applications
  • Shieldbreak Housing Type (Style 4, Size 5) for robust protection
  • Aluminum Connector (Code 47P) for conductors 1.378-1.425 inch
  • Heatsink Size 55 (3.000" OD, 1.468" Bore) for thermal management
  • Includes Copper Tape Shield, Bonding Cable, and Heat Shrink Restoration Kit

Specifications

Application
For use on Solid Dielectric Cables - providing permanent, fully-shielded, fully submersible cable joints for direct burial or vault applications
Color
Black
Conductor Range
1.378 to 1.425 in
Connection
Compression
Insulation
Yes
Material
EPDM Rubber
Number Of Conductors
2
Special Features
Each Cable Joint is produced exactly to design, producing a quality not possible with field molding equipment or tape. Electrically tested in the factory to ensure consistent quality. Molding is done in the factory, reducing on-site time - no penciling of cable installation required. Easy to learn installation procedure. Field molds, wrapping machines or pre-stretch not required, and a low-cost assembly tool is available. Extended shelf life enables instant availability of spares. Designed with optimized pre-molded stress control and heat transfer capabilities
Standard
ANSI C119.4, Shield Test IEEE 592
Temperature Rating, Maximum
194 F
Temperature Rating, Maximum
90 C
Temperature Rating, Minimum
194 F
Temperature Rating, Minimum
90 C
Type
Transmission Cable Joint - Shieldbreak
Voltage Rating
69 kV
Package Dimensions (L x W x H)
0.01 IN x 0.01 IN x 0.01 IN
Package Dimensions (L x W x H)
0.0254 cm x 0.0254 cm x 0.0254 cm
Package Weight (Imperial)
1.0000 L
Package Weight (Metric)
0.4540 kg
69 kV, TCJ - Transmission Cable Joint. Housing Type - Shieldbreak. Housing Style 4. Housing Size 5.

69TCJS4-5-4

69 kV, TCJ - Transmission Cable Joint. Housing Type - Shieldbreak. Housing Style 4. Housing Size 5.
69kV, Transmission Cable Joint, Housing Type - Shieldbreak, Housing Style 1, Housing Size R - Bore Diameter 1.930 inch, Insulation Range 2.200-2.580 inch, Connector Type - Copper, Conductor Code 46P - 1.328-1.377 inch Diameter, Heatsink Size and Bore not Required, Type Shield B - Copper 1/3 Neutral Wire, Metallic Screen Continuity Kit H - 4/0 Bonding Cable 4 foot long Quantity 2 without Split Bolts, Armour Kit Not Required, Outer Jacket Restoration Kit Not Required.

69TCJS1R246PNBHNN

69kV, Transmission Cable Joint, Housing Type - Shieldbreak, Housing Style 1, Housing Size R - Bore Diameter 1.930 inch, Insulation Range 2.200-2.580 inch, Connector Type - Copper, Conductor Code 46P - 1.328-1.377 inch Diameter, Heatsink Size and Bore not Required, Type Shield B - Copper 1/3 Neutral Wire, Metallic Screen Continuity Kit H - 4/0 Bonding Cable 4 foot long Quantity 2 without Split Bolts, Armour Kit Not Required, Outer Jacket Restoration Kit Not Required.
15kV Power Cable Joint Style 2 with Universal Housing and Separate Cable Adapters. Cable Insulation Diameter 0.640 inch to 0.820 inch. Aluminum Conductor. Conductor Size AWG Stranded #2/Solid #1.

15PCJ2F1220

15kV Power Cable Joint Style 2 with Universal Housing and Separate Cable Adapters. Cable Insulation Diameter 0.640 inch to 0.820 inch. Aluminum Conductor. Conductor Size AWG Stranded #2/Solid #1.
15kV Power Cable Joint Style 2 with Universal Housing and Separate Cable Adapters. Cable Insulation Diameter 0.640 inch to 0.820 inch. Aluminum Conductor. Conductor Size AWG Stranded 2/0 /Solid 3/0.

15PCJ2F1250

15kV Power Cable Joint Style 2 with Universal Housing and Separate Cable Adapters. Cable Insulation Diameter 0.640 inch to 0.820 inch. Aluminum Conductor. Conductor Size AWG Stranded 2/0 /Solid 3/0.
15kV Power Cable Joint Style 2 with Universal Housing and Separate Cable Adapters. Cable Insulation Diameter 0.760 inch to 0.950 inch. Aluminum Conductor. Conductor Size AWG Stranded #2/Solid #1.

15PCJ2G1220

15kV Power Cable Joint Style 2 with Universal Housing and Separate Cable Adapters. Cable Insulation Diameter 0.760 inch to 0.950 inch. Aluminum Conductor. Conductor Size AWG Stranded #2/Solid #1.
15kV, Power Cable Joint, Single Piece Housing, Cable Insulation .760-.950 inches, Copper Compression Lug, Conductor Size #2 Compact/Solid.

15PCJ1G2210

15kV, Power Cable Joint, Single Piece Housing, Cable Insulation .760-.950 inches, Copper Compression Lug, Conductor Size #2 Compact/Solid.
138kV, Transmission Joint Cable, Shieldbreak Housing, Housing Style 4, Housing Size 4. Copper Connector, Connector Size 1.328-1.377 inch (33.73-34.98mm). HeatShrink Size 2.750 inch (69.86mm). HeatShrink Bore 1.406 inches, Shield - Copper Neutral Wire, Metallic Screen Continuity Kit - 4/0 Bonding Cable, 6 foot, Quantity 4, without Split Bolts, Armor Kit is not Required, Outer Jacket Restoration Kit is not Required

138TCJS44246P5LBLNN

138kV, Transmission Joint Cable, Shieldbreak Housing, Housing Style 4, Housing Size 4. Copper Connector, Connector Size 1.328-1.377 inch (33.73-34.98mm). HeatShrink Size 2.750 inch (69.86mm). HeatShrink Bore 1.406 inches, Shield - Copper Neutral Wire, Metallic Screen Continuity Kit - 4/0 Bonding Cable, 6 foot, Quantity 4, without Split Bolts, Armor Kit is not Required, Outer Jacket Restoration Kit is not Required
15kV, Power Cable Joint, Style 2 with Universal Housing and Separate Cable Adapters that can be varied with the Cable Application, Insulation Diameter .980-1.180 inches, Aluminum Conductor, Conductor Size 1/0 Stranded/Compressed or 2/0 Solid/Compact.

15PCJ2J1240

15kV, Power Cable Joint, Style 2 with Universal Housing and Separate Cable Adapters that can be varied with the Cable Application, Insulation Diameter .980-1.180 inches, Aluminum Conductor, Conductor Size 1/0 Stranded/Compressed or 2/0 Solid/Compact.

Frequently Asked Questions

What are TCJ transmission cable joints designed for?

TCJ transmission cable joints are designed for 46 kV through 138 kV class systems on solid dielectric cables.

What materials are used in the pre-molded housing of TCJ joints?

The void-free joint housing consists of peroxide-cured EPDM insulation bonded under pressure to peroxide-cured molded semi-conductive elements.

What is the continuous current rating of TCJ transmission cable joints?

The continuous current rating of TCJ transmission cable joints is equal to the cable's continuous rating.

What is the minimum corona extinction voltage for a 138 kV class joint?

The minimum corona extinction voltage for a 138 kV class joint is 120 kV (3 pC sensitivity).

What is the BIL rating for a 69 kV class TCJ joint?

The BIL rating for a 69 kV class TCJ joint is 350 kV (1.2 x 50μs; 10 pos., 10 neg., impulses).

What is the maximum continuous conductor temperature for TCJ joints?

The maximum continuous conductor temperature for TCJ joints is 90 °C.

What is the maximum system voltage for a 138 kV class TCJ joint?

The maximum system voltage for a 138 kV class TCJ joint is 145 kV.

What is the maximum system voltage for a 69 kV class TCJ joint?

The maximum system voltage for a 69 kV class TCJ joint is 72.5 kV.

What applications are TCJ transmission cable joints suitable for?

They are suitable for direct-burial or vault applications, providing permanent, fully shielded, and fully submersible cable joints.

What cable insulation diameters are compatible with TCJ joints?

For Style 1 (through 69 kV), insulation diameters are 1.43 inches to 2.58 inches. For Style 4 (through 138 kV), they are 2.25 inches to 3.62 inches.

Frequently Asked Questions about ABB - Installation Products

How are Thomas and Betts products typically installed?

Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.

What accessories are available for Thomas and Betts products?

Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.

What environmental ratings do Thomas and Betts products have?

Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.

What communication protocols do Thomas and Betts products support?

Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.

What are the key features of Thomas and Betts products?

Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.

What are the main product lines offered by Thomas and Betts?

Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.

What technical support does Thomas and Betts offer?

Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.

What industries and applications are Thomas and Betts products used for?

Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.

What certifications and standards do Thomas and Betts products comply with?

Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.

What are the main product lines offered by Ocal?

Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.