Authorized ABB Distributor (Installation Products)
ABB - Installation Products 15PCJ2F1250 - 15kV Power Cable Joint Style 2 with Universal Housing and Separate Cable Adapters. Cable Insulation Diameter 0.640 inch to 0.820 inch. Aluminum Conductor. Conductor Size AWG Stranded 2/0 /Solid 3/0.

ABB Installation Products 15PCJ2F1250 15kV Power Cable Joint Style 2 with Universal Housing and Separate Cable Adapters. Cable…

UPC: 075114240765


Documents & Media
BrochureInstallation InstructionsSpecification SheetManufacturer Product Website

Contact for Pricing

Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.

Overview

The ABB 15kV Power Cable Joint, SKU 15PCJ2F1250, is a Style 2 termination designed for reliable electrical connections. This joint features a universal housing, accommodating a wide range of cable sizes, and includes separate cable adapters for precise fitting. It is engineered for aluminum conductors, supporting both stranded 2/0 AWG and solid 3/0 AWG sizes. The cable insulation diameter range for this joint is 0.640 inches to 0.820 inches, ensuring compatibility with specific cable constructions. This product is part of ABB's Installation Products catalog, known for its focus on electrical infrastructure components. The UNSPSC code for this item is 39121452. This joint provides a secure and insulated connection point for 15kV power cables, essential for maintaining system integrity in electrical distribution networks.
  • 15kV Power Cable Joint, Style 2
  • Universal Housing with Separate Cable Adapters
  • Cable Insulation Diameter: 0.640" - 0.820"
  • Aluminum Conductor: 2/0 AWG Stranded / 3/0 AWG Solid
  • Manufacturer: ABB - Installation Products

Specifications

Application
For Direct Burial, Vault, Submersible and Other Severe Service Applications
Color
Black
Conductor Range
2/0 STR AWG , 3/0 SOL AWG
Connection
Compression
Insulation
Yes
Material
EPDM Rubber
Number Of Conductors
2
Size
16-3/8 inch long
Special Features
Power Cable Joints utilize permanently crimped connectors. PCJ housings are fully insulated, shielded and sealed for direct-burial, vault, submersible and other servere service applications. Units have been designed and tested per IEEE Standard 404 to ensure system matched performance and ratings equal to the cable to which the splice will be installed. Power Cable Joints are available in two styles. Style 1 uses a single-piece housing that is sized to accommodate a specific range of cable - ideally suited to straight splicing of the same or similar cable. Style 2 designs incorporate a universal housing with separate cable adapters to allow transition splices of different types and sizes of cable
Standard
IEEE Standard 404
Type
Power Cable Joint
Voltage Rating
15 kV
Package Dimensions (L x W x H)
0.01 IN x 0.01 IN x 0.01 IN
Package Dimensions (L x W x H)
0.0254 cm x 0.0254 cm x 0.0254 cm
Package Weight (Imperial)
1.0000 L
Package Weight (Metric)
0.4540 kg
15kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 0.850 inch to 1.050 inch. Aluminum Conductor. Conductor Size AWG Stranded 2/0 /Solid 3/0.

15PCJ1H1250

15kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 0.850 inch to 1.050 inch. Aluminum Conductor. Conductor Size AWG Stranded 2/0 /Solid 3/0.
15kV Power Cable Joint Style 2 with Universal Housing and Separate Cable Adapters. Cable Insulation Diameter 0.760 inch to 0.950 inch. Aluminum Conductor. Conductor Size AWG Stranded #2/Solid #1.

15PCJ2G1220

15kV Power Cable Joint Style 2 with Universal Housing and Separate Cable Adapters. Cable Insulation Diameter 0.760 inch to 0.950 inch. Aluminum Conductor. Conductor Size AWG Stranded #2/Solid #1.
15kV, Power Cable Joint, Single Piece Housing, Cable Insulation .760-.950 inches, Copper Compression Lug, Conductor Size #2 Compact/Solid.

15PCJ1G2210

15kV, Power Cable Joint, Single Piece Housing, Cable Insulation .760-.950 inches, Copper Compression Lug, Conductor Size #2 Compact/Solid.
138kV, Transmission Joint Cable, Shieldbreak Housing, Housing Style 4, Housing Size 4. Copper Connector, Connector Size 1.328-1.377 inch (33.73-34.98mm). HeatShrink Size 2.750 inch (69.86mm). HeatShrink Bore 1.406 inches, Shield - Copper Neutral Wire, Metallic Screen Continuity Kit - 4/0 Bonding Cable, 6 foot, Quantity 4, without Split Bolts, Armor Kit is not Required, Outer Jacket Restoration Kit is not Required

138TCJS44246P5LBLNN

138kV, Transmission Joint Cable, Shieldbreak Housing, Housing Style 4, Housing Size 4. Copper Connector, Connector Size 1.328-1.377 inch (33.73-34.98mm). HeatShrink Size 2.750 inch (69.86mm). HeatShrink Bore 1.406 inches, Shield - Copper Neutral Wire, Metallic Screen Continuity Kit - 4/0 Bonding Cable, 6 foot, Quantity 4, without Split Bolts, Armor Kit is not Required, Outer Jacket Restoration Kit is not Required
15kV, Power Cable Joint, Style 2 with Universal Housing and Separate Cable Adapters that can be varied with the Cable Application, Insulation Diameter .980-1.180 inches, Aluminum Conductor, Conductor Size 1/0 Stranded/Compressed or 2/0 Solid/Compact.

15PCJ2J1240

15kV, Power Cable Joint, Style 2 with Universal Housing and Separate Cable Adapters that can be varied with the Cable Application, Insulation Diameter .980-1.180 inches, Aluminum Conductor, Conductor Size 1/0 Stranded/Compressed or 2/0 Solid/Compact.
15kV, Power Cable Joint, with Universal Housing and separate Cable Adapters that can be varied with the cable application, Cable Insulation .980-1.180 inches, Copper Compression Lug, Conductor Size 350 Compact/Solid to Cable Insulation .850-1.050 inches, Copper Compression Lug, Conductor Size 4/0 Stranded/Compressed or 250 Compact/Solid

15PCJ2J2290-H2270

15kV, Power Cable Joint, with Universal Housing and separate Cable Adapters that can be varied with the cable application, Cable Insulation .980-1.180 inches, Copper Compression Lug, Conductor Size 350 Compact/Solid to Cable Insulation .850-1.050 inches, Copper Compression Lug, Conductor Size 4/0 Stranded/Compressed or 250 Compact/Solid
15kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 1.515 inch to 1.780 inch. Aluminum Conductor. Conductor Size AWG Stranded 1000.

15PCJ1N1410

15kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 1.515 inch to 1.780 inch. Aluminum Conductor. Conductor Size AWG Stranded 1000.
15 kV, Power Cable Joint, Style 1 - 14-3/8 X 2-25/32 inches, Cable Insulation Diameter - 1.370-1.630 inches, Aluminum Connector, Conductor Size - 1000 kcmil.

15PCJ1M1400

15 kV, Power Cable Joint, Style 1 - 14-3/8 X 2-25/32 inches, Cable Insulation Diameter - 1.370-1.630 inches, Aluminum Connector, Conductor Size - 1000 kcmil.

Frequently Asked Questions

What conductor types are compatible with PCJ cable joints?

PCJ power cable joints can be used with both copper and aluminum conductors, supporting a wide range of sizes up to 1250 kcmil.

What are the continuous and short-time current ratings?

The continuous current rating is equal to that of the cable rating. The short-time current rating is also equal to the cable rating, up to 35 kA.

What voltage classes are available for PCJ cable joints?

Elastimold PCJ power cable joints are available in 15 kV, 25 kV, and 35 kV classes.

What safety standards do PCJ cable joints meet?

The shield design meets IEEE 592 standard. The connectors meet ANSI 119.4 Class A and Class 3 ratings.

What safety standards do PCJ cable joints meet?

The shield design meets IEEE 592 standard. The connectors meet ANSI 119.4 Class A and Class 3 ratings.

What are the continuous and short-time current ratings?

The continuous current rating is equal to that of the cable rating. The short-time current rating is also equal to the cable rating, up to 35 kA.

What conductor types are compatible with PCJ cable joints?

PCJ power cable joints can be used with both copper and aluminum conductors, supporting a wide range of sizes up to 1250 kcmil.

What voltage classes are available for PCJ cable joints?

Elastimold PCJ power cable joints are available in 15 kV, 25 kV, and 35 kV classes.

What voltage classes are available for PCJ cable joints?

Elastimold PCJ power cable joints are available in 15 kV, 25 kV, and 35 kV classes.

What conductor types are compatible with PCJ cable joints?

PCJ power cable joints can be used with both copper and aluminum conductors, supporting a wide range of sizes up to 1250 kcmil.

How to Install the 15/25/35PCJ2WXXXX-RC Straight Joint

This guide provides step-by-step instructions for the permanent, fully shielded, and submersible installation of the 15/25/35PCJ2WXXXX-RC straight joint for aluminum and/or copper conductor, wire shielded cables.

Estimated time: 2h

Tools needed:

Stripping guide, Hex wrench, Wirebrush, Crimping tool, Circular cutting tool or glass (for graphite removal)

Supplies needed:

Joint Housing, Splice (Conductor Contact), Cable Adapters, Lubricant, Retaining Collars (2), Hose Clamp, Electrical tape, Appropriate connector (for grounding wires, user supplied), Heat/cold shrink materials (for cable jacket reconstruction, user supplied), Bonding and sealing materials (for lead sheath/neutral wires, user supplied)

  1. Prepare Cables and Install Housing

    Before starting, ensure all apparatus is de-energized and inspect all components for damage and compatibility. Using the stripping guide, carefully remove the cable jacket of both cables for 11-1/4” (285.7mm). Fold back shield wires and tape their ends on Cable 1, allowing extra length for rejoining. Clean the surface of the insulation shield, shield wires, and jacket for 30” (760mm). Slide the joint housing onto Cable 1 for a distance of 30” (760mm).

  2. Prepare Cable Insulation

    Using the stripping guide, carefully remove the insulation shield and cable insulation. WARNING: DO NOT CUT OR NICK THE INSULATION, as this could result in assembly failure. Wrap two turns of electrical tape 1” (25mm) from the edge of the insulation shield on both cables as a marker. Clean the cable insulation, then lubricate it to create a build-up or ramp at the edge of the insulation shield.

  3. Install Cable Adapters

    Lubricate the inside of both ends of one cable adapter. Install the lubricated cable adapter onto the cable until it meets the tape marker. Repeat this process for the other cable adapter on the second cable.

  4. Install Retaining Collars

    Select the correct retaining collar and partially thread the appropriate size setscrews (refer to collar instructions). Position the retaining collar over the insulation, flush against the cable adapter. Using the supplied hex wrench, tighten each set screw one or two turns at a time to keep the collar centered. Continue tightening until the set screws are below the collar surface. Repeat for Cable 2.

  5. Prepare for Splice and Crimp Conductors

    Thoroughly clean the ends of the cable adapters and the cable as indicated. Install a hose clamp around the adapter on the side opposite the stored housing to hold the adapter in place, then tape over the hose clamp to create a smooth surface. Wirebrush the exposed conductors of both cables and immediately insert them into the splice. Ensure the 'Check' dimension does not exceed 8-1/2” (215mm); if it does, redo the assembly. Crimp the splice according to its specific recommendations.

  6. Final Splice Checks and Lubrication

    Wipe off all excess inhibitor from the splice. Verify the distance between cable adapters; if it exceeds 8-3/4” (222mm), redo the assembly. Clean and lubricate the outside surface of the cable adapters before sliding the housing into its final position.

  7. Position Housing and Secure Shield Wires

    Slide the housing into its final position, centering it over the cable adapters. Remove all tape, ensuring that cable and adapter insulation are not exposed after positioning the joint. Reshape the shield wires and secure them to the ends of the joint.

  8. Connect Grounding Wires and Reconstruct Jacket

    Insert one shield wire from Cable 1 (if #14 AWG or larger) through the joint grounding eye; repeat for Cable 2. If shield wires are smaller than #14 AWG, use a separate #14 AWG copper wire or equivalent. Connect the joint grounding wires and remaining shield wires using an appropriate user-supplied connector. Reconstruct the cable jacket (where applicable) over both cables and the joint housing using heat/cold shrink materials (not included).

Frequently Asked Questions about ABB - Installation Products

How are Thomas and Betts products typically installed?

Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.

What accessories are available for Thomas and Betts products?

Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.

What environmental ratings do Thomas and Betts products have?

Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.

What communication protocols do Thomas and Betts products support?

Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.

What are the key features of Thomas and Betts products?

Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.

What are the main product lines offered by Thomas and Betts?

Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.

What technical support does Thomas and Betts offer?

Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.

What industries and applications are Thomas and Betts products used for?

Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.

What certifications and standards do Thomas and Betts products comply with?

Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.

What are the main product lines offered by Ocal?

Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.