ABB - Installation Products 69TCJS1R246PNBHNN - 69kV, Transmission Cable Joint, Housing Type - Shieldbreak, Housing Style 1, Housing Size R - Bore Diameter 1.930 inch, Insulation Range 2.200-2.580 inch, Connector Type - Copper, Conductor Code 46P - 1.328-1.377 inch Diameter, Heatsink Size and Bore not Required, Type Shield B - Copper 1/3 Neutral Wire, Metallic Screen Continuity Kit H - 4/0 Bonding Cable 4 foot long Quantity 2 without Split Bolts, Armour Kit Not Required, Outer Jacket Restoration Kit Not Required.
ABB - Installation Products

69TCJS1R246PNBHNN

UPC: 075114277518


Documents & Media
Specification SheetManufacturer Product Website

Contact for Pricing

Overview

The ABB 69kV Transmission Cable Joint, SKU 69TCJS1R246PNBHNN, is engineered for high-voltage power transmission applications. This specific unit features a Shieldbreak housing type, Housing Style 1, and Housing Size R, designed to accommodate a bore diameter of 1.930 inches. It is suitable for insulation ranges between 2.200 and 2.580 inches, ensuring a secure fit for a variety of cable constructions. For conductor connections, this joint utilizes a copper connector. The specified conductor code is 46P, indicating compatibility with conductors ranging from 1.328 to 1.377 inches in diameter. The design does not require a separate heatsink. The metallic screen continuity is achieved with Type Shield B, which includes a copper 1/3 neutral wire. A Metallic Screen Continuity Kit H is provided, featuring two 4-foot long 4/0 bonding cables, supplied without split bolts for direct integration.
  • 69kV rated transmission cable joint
  • Shieldbreak housing type, Housing Style 1, Size R
  • Copper connector for conductors 1.328-1.377 inch diameter
  • Insulation range: 2.200-2.580 inches
  • Includes Metallic Screen Continuity Kit H with 4/0 bonding cables

Specifications

Application
For use on Solid Dielectric Cables - providing permanent, fully-shielded, fully submersible cable joints for direct burial or vault applications
Color
Black
Conductor Range
1.328 to 1.377 in
Connection
Compression
Insulation
Yes
Material
EPDM Rubber
Number Of Conductors
2
Special Features
Each Cable Joint is produced exactly to design, producing a quality not possible with field molding equipment or tape. Electrically tested in the factory to ensure consistent quality. Molding is done in the factory, reducing on-site time - no penciling of cable installation required. Easy to learn installation procedure. Field molds, wrapping machines or pre-stretch not required, and a low-cost assembly tool is available. Extended shelf life enables instant availability of spares. Designed with optimized pre-molded stress control and heat transfer capabilities
Standard
ANSI C119.4, Shield Test IEEE 592
Temperature Rating, Maximum
194 F
Temperature Rating, Maximum
90 C
Temperature Rating, Minimum
194 F
Temperature Rating, Minimum
90 C
Type
Transmission Cable Joint - Shieldbreak
Voltage Rating
69 kV
Package Dimensions (L x W x H)
0.01 IN x 0.01 IN x 0.01 IN
Package Dimensions (L x W x H)
0.0254 cm x 0.0254 cm x 0.0254 cm
Package Weight (Imperial)
1.0000 L
Package Weight (Metric)
0.4540 kg
69 kv, Transmission Cable Joint, Housing Type - Shieldbreak, Housing Style 1, Housing Size R Bore Diameter at Jacket/Insulation Transition 1.930. Connector Type - Aluminum/no connector required, Connector Code 46P - Conductor Diameter Range - 1.328-1.377 inch (33.73-34.98mm), Heatsink Size - N - not required, Heatsink Bore - N - not required. Type Shield - N - not required, Metallic Screen Continuity Kit - N - not required, Armor Kit - N - not required, Outer Jacket Restoration Kit - N - not required

69TCJS1RA46PNNNNNN

69 kv, Transmission Cable Joint, Housing Type - Shieldbreak, Housing Style 1, Housing Size R Bore Diameter at Jacket/Insulation Transition 1.930. Connector Type - Aluminum/no connector required, Connector Code 46P - Conductor Diameter Range - 1.328-1.377 inch (33.73-34.98mm), Heatsink Size - N - not required, Heatsink Bore - N - not required. Type Shield - N - not required, Metallic Screen Continuity Kit - N - not required, Armor Kit - N - not required, Outer Jacket Restoration Kit - N - not required
15kV Power Cable Joint Style 2 with Universal Housing and Separate Cable Adapters. Cable Insulation Diameter 0.640 inch to 0.820 inch. Aluminum Conductor. Conductor Size AWG Stranded #2/Solid #1.

15PCJ2F1220

15kV Power Cable Joint Style 2 with Universal Housing and Separate Cable Adapters. Cable Insulation Diameter 0.640 inch to 0.820 inch. Aluminum Conductor. Conductor Size AWG Stranded #2/Solid #1.
15kV Power Cable Joint Style 2 with Universal Housing and Separate Cable Adapters. Cable Insulation Diameter 0.640 inch to 0.820 inch. Aluminum Conductor. Conductor Size AWG Stranded 2/0 /Solid 3/0.

15PCJ2F1250

15kV Power Cable Joint Style 2 with Universal Housing and Separate Cable Adapters. Cable Insulation Diameter 0.640 inch to 0.820 inch. Aluminum Conductor. Conductor Size AWG Stranded 2/0 /Solid 3/0.
15kV Power Cable Joint Style 2 with Universal Housing and Separate Cable Adapters. Cable Insulation Diameter 0.760 inch to 0.950 inch. Aluminum Conductor. Conductor Size AWG Stranded #2/Solid #1.

15PCJ2G1220

15kV Power Cable Joint Style 2 with Universal Housing and Separate Cable Adapters. Cable Insulation Diameter 0.760 inch to 0.950 inch. Aluminum Conductor. Conductor Size AWG Stranded #2/Solid #1.
15kV, Power Cable Joint, Single Piece Housing, Cable Insulation .760-.950 inches, Copper Compression Lug, Conductor Size #2 Compact/Solid.

15PCJ1G2210

15kV, Power Cable Joint, Single Piece Housing, Cable Insulation .760-.950 inches, Copper Compression Lug, Conductor Size #2 Compact/Solid.
138kV, Transmission Joint Cable, Shieldbreak Housing, Housing Style 4, Housing Size 4. Copper Connector, Connector Size 1.328-1.377 inch (33.73-34.98mm). HeatShrink Size 2.750 inch (69.86mm). HeatShrink Bore 1.406 inches, Shield - Copper Neutral Wire, Metallic Screen Continuity Kit - 4/0 Bonding Cable, 6 foot, Quantity 4, without Split Bolts, Armor Kit is not Required, Outer Jacket Restoration Kit is not Required

138TCJS44246P5LBLNN

138kV, Transmission Joint Cable, Shieldbreak Housing, Housing Style 4, Housing Size 4. Copper Connector, Connector Size 1.328-1.377 inch (33.73-34.98mm). HeatShrink Size 2.750 inch (69.86mm). HeatShrink Bore 1.406 inches, Shield - Copper Neutral Wire, Metallic Screen Continuity Kit - 4/0 Bonding Cable, 6 foot, Quantity 4, without Split Bolts, Armor Kit is not Required, Outer Jacket Restoration Kit is not Required
15kV, Power Cable Joint, Style 2 with Universal Housing and Separate Cable Adapters that can be varied with the Cable Application, Insulation Diameter .980-1.180 inches, Aluminum Conductor, Conductor Size 1/0 Stranded/Compressed or 2/0 Solid/Compact.

15PCJ2J1240

15kV, Power Cable Joint, Style 2 with Universal Housing and Separate Cable Adapters that can be varied with the Cable Application, Insulation Diameter .980-1.180 inches, Aluminum Conductor, Conductor Size 1/0 Stranded/Compressed or 2/0 Solid/Compact.
15kV, Power Cable Joint, with Universal Housing and separate Cable Adapters that can be varied with the cable application, Cable Insulation .980-1.180 inches, Copper Compression Lug, Conductor Size 350 Compact/Solid to Cable Insulation .850-1.050 inches, Copper Compression Lug, Conductor Size 4/0 Stranded/Compressed or 250 Compact/Solid

15PCJ2J2290-H2270

15kV, Power Cable Joint, with Universal Housing and separate Cable Adapters that can be varied with the cable application, Cable Insulation .980-1.180 inches, Copper Compression Lug, Conductor Size 350 Compact/Solid to Cable Insulation .850-1.050 inches, Copper Compression Lug, Conductor Size 4/0 Stranded/Compressed or 250 Compact/Solid

Frequently Asked Questions

What is the insulation range for this 69kV cable joint?

The insulation range for this ABB 69kV cable joint is 2.200 to 2.580 inches.

What conductor diameter is compatible with this joint?

This joint is compatible with conductors ranging from 1.328 to 1.377 inches in diameter, corresponding to conductor code 46P.

What type of housing does this ABB cable joint feature?

This ABB cable joint features a Shieldbreak housing type, specifically Housing Style 1 and Housing Size R.

Does this cable joint include a metallic screen continuity kit?

Yes, this cable joint includes a Metallic Screen Continuity Kit H, which contains two 4-foot long 4/0 bonding cables.

What is the bore diameter of the housing for this joint?

The housing for this ABB 69kV cable joint has a bore diameter of 1.930 inches.

Frequently Asked Questions about ABB - Installation Products

How are Thomas and Betts products typically installed?

Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.

What accessories are available for Thomas and Betts products?

Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.

What environmental ratings do Thomas and Betts products have?

Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.

What communication protocols do Thomas and Betts products support?

Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.

What are the key features of Thomas and Betts products?

Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.

What are the main product lines offered by Thomas and Betts?

Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.

What technical support does Thomas and Betts offer?

Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.

What industries and applications are Thomas and Betts products used for?

Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.

What certifications and standards do Thomas and Betts products comply with?

Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.

What are the main product lines offered by Ocal?

Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.