ABB - Installation Products 138TCJS44246P5LBLNN - 138kV, Transmission Joint Cable, Shieldbreak Housing, Housing Style 4, Housing Size 4. Copper Connector, Connector Size 1.328-1.377 inch (33.73-34.98mm). HeatShrink Size 2.750 inch (69.86mm). HeatShrink Bore 1.406 inches, Shield - Copper Neutral Wire, Metallic Screen Continuity Kit - 4/0 Bonding Cable, 6 foot, Quantity 4, without Split Bolts, Armor Kit is not Required, Outer Jacket Restoration Kit is not Required
ABB - Installation Products

138TCJS44246P5LBLNN

UPC: 075114295673


Documents & Media
Specification SheetManufacturer Product Website

Contact for Pricing

Overview

This ABB 138kV Transmission Joint Cable, identified by SKU 138TCJS44246P5LBLNN, is engineered for high-voltage transmission applications. It features a robust Shieldbreak Housing, specifically Style 4 and Size 4, ensuring reliable insulation and protection for critical cable joints. The integrated copper connector accommodates cable sizes ranging from 1.328 to 1.377 inches (33.73-34.98mm), providing a secure and conductive connection. The heat shrink component measures 2.750 inches (69.86mm) with a bore of 1.406 inches, designed for a precise fit and effective sealing. This joint kit includes a copper neutral wire and a Metallic Screen Continuity Kit utilizing a 4/0 bonding cable, extending 6 feet in length with a quantity of 4. This configuration ensures effective grounding and maintains screen continuity across the joint. The product is supplied without split bolts, and an armor kit or outer jacket restoration kit is not required, simplifying installation for specific cable types. Manufactured by ABB - Installation Products, this component adheres to the UNSPSC code 39121452, indicating its classification within electrical power distribution and transmission infrastructure. This solution is designed for the demanding requirements of 138kV transmission systems where joint integrity and electrical continuity are paramount.
  • 138kV Transmission Joint Cable
  • Shieldbreak Housing Style 4, Size 4
  • Copper Connector: 1.328-1.377 inch (33.73-34.98mm)
  • HeatShrink Size: 2.750 inch (69.86mm), Bore: 1.406 inches
  • Includes 4/0 Bonding Cable for Screen Continuity

Specifications

Application
For use on Solid Dielectric Cables - providing permanent, fully-shielded, fully submersible cable joints for direct burial or vault applications
Color
Black
Conductor Range
1.328 to 1.377 in
Connection
Compression
Insulation
Yes
Material
EPDM Rubber
Number Of Conductors
2
Special Features
Each Cable Joint is produced exactly to design, producing a quality not possible with field molding equipment or tape. Electrically tested in the factory to ensure consistent quality. Molding is done in the factory, reducing on-site time - no penciling of cable installation required. Easy to learn installation procedure. Field molds, wrapping machines or pre-stretch not required, and a low-cost assembly tool is available. Extended shelf life enables instant availability of spares. Designed with optimized pre-molded stress control and heat transfer capabilities
Standard
ANSI C119.4, Shield Test IEEE 592
Temperature Rating, Maximum
194 F
Temperature Rating, Maximum
90 C
Temperature Rating, Minimum
194 F
Temperature Rating, Minimum
90 C
Type
Transmission Cable Joint - Shieldbreak
Voltage Rating
138 kV
Package Dimensions (L x W x H)
0.01 IN x 0.01 IN x 0.01 IN
Package Dimensions (L x W x H)
0.0254 cm x 0.0254 cm x 0.0254 cm
Package Weight (Imperial)
1.0000 L
Package Weight (Metric)
0.4540 kg
69 kv, Transmission Cable Joint, Housing Type - Non-Shieldbreak, Housing Style 1, Housing Size R Bore Diameter at Jacket/Insulation Transition 1.930. Connector Type - Aluminum/No connector Requiered, Connector Code 46P - Conductor Diameter Range - 1.328-1.377 inch (33.73-34.98mm), Heatsink Size/Bore - V - 2.046 inch Diameter. Type Shield - E - Lead, Metallic Screen Continuity Kit - J - 4/0 Bonding Cable 4 foot quantity 3 without split bolts, Armor Kit - N - not required, Outer Jacket Restoration Kit - B - HeatShrink

69TCJN1RA46PVEJNB

69 kv, Transmission Cable Joint, Housing Type - Non-Shieldbreak, Housing Style 1, Housing Size R Bore Diameter at Jacket/Insulation Transition 1.930. Connector Type - Aluminum/No connector Requiered, Connector Code 46P - Conductor Diameter Range - 1.328-1.377 inch (33.73-34.98mm), Heatsink Size/Bore - V - 2.046 inch Diameter. Type Shield - E - Lead, Metallic Screen Continuity Kit - J - 4/0 Bonding Cable 4 foot quantity 3 without split bolts, Armor Kit - N - not required, Outer Jacket Restoration Kit - B - HeatShrink
15kV, Power Cable Joint, Style 2 with Universal Housing and Separate Cable Adapters that can be varied with the Cable Application, Insulation Diameter .980-1.180 inches, Aluminum Conductor, Conductor Size 1/0 Stranded/Compressed or 2/0 Solid/Compact.

15PCJ2J1240

15kV, Power Cable Joint, Style 2 with Universal Housing and Separate Cable Adapters that can be varied with the Cable Application, Insulation Diameter .980-1.180 inches, Aluminum Conductor, Conductor Size 1/0 Stranded/Compressed or 2/0 Solid/Compact.
15kV, Power Cable Joint, with Universal Housing and separate Cable Adapters that can be varied with the cable application, Cable Insulation .980-1.180 inches, Copper Compression Lug, Conductor Size 350 Compact/Solid to Cable Insulation .850-1.050 inches, Copper Compression Lug, Conductor Size 4/0 Stranded/Compressed or 250 Compact/Solid

15PCJ2J2290-H2270

15kV, Power Cable Joint, with Universal Housing and separate Cable Adapters that can be varied with the cable application, Cable Insulation .980-1.180 inches, Copper Compression Lug, Conductor Size 350 Compact/Solid to Cable Insulation .850-1.050 inches, Copper Compression Lug, Conductor Size 4/0 Stranded/Compressed or 250 Compact/Solid
15kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 1.515 inch to 1.780 inch. Aluminum Conductor. Conductor Size AWG Stranded 1000.

15PCJ1N1410

15kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 1.515 inch to 1.780 inch. Aluminum Conductor. Conductor Size AWG Stranded 1000.
15 kV, Power Cable Joint, Style 1 - 14-3/8 X 2-25/32 inches, Cable Insulation Diameter - 1.370-1.630 inches, Aluminum Connector, Conductor Size - 1000 kcmil.

15PCJ1M1400

15 kV, Power Cable Joint, Style 1 - 14-3/8 X 2-25/32 inches, Cable Insulation Diameter - 1.370-1.630 inches, Aluminum Connector, Conductor Size - 1000 kcmil.
25kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 0.850 inch to 1.050 inch. Aluminum Conductor. Conductor Size AWG Stranded 250

25PCJ1H1280

25kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 0.850 inch to 1.050 inch. Aluminum Conductor. Conductor Size AWG Stranded 250
35kV, PCJ - Power Cable Joint, with Single Piece Housing, Cable Insulation Diameter .850 - 1.050 inches, Housing Only

35PCJ1-H

35kV, PCJ - Power Cable Joint, with Single Piece Housing, Cable Insulation Diameter .850 - 1.050 inches, Housing Only
35kV Power Cable Joint Style 1, Cable Insulation Diameter 1.090 inch to 1.310 inch. Aluminum Compression Lug. Conductor Size AWG Compressed Stranded 500 /Solid 600 /mmSquared 250/300.

35PCJ1K1330

35kV Power Cable Joint Style 1, Cable Insulation Diameter 1.090 inch to 1.310 inch. Aluminum Compression Lug. Conductor Size AWG Compressed Stranded 500 /Solid 600 /mmSquared 250/300.

Frequently Asked Questions

What is the minimum corona extinction voltage for 138 kV systems?

For 138 kV nominal systems, the minimum corona extinction voltage is 120 kV (3 pC sensitivity).

What voltage systems are TCJ joints designed for?

TCJ transmission cable joints are designed for 46 kV through 138 kV class systems.

What cable types are compatible with TCJ joints?

TCJ transmission cable joints are designed for use on solid dielectric cables.

What are the maximum system voltage ratings?

The maximum system voltage for 69 kV nominal systems is 72.5 kV, and for 138 kV nominal systems, it is 145 kV.

What is the continuous current rating for these joints?

The continuous current rating for TCJ transmission cable joints is equal to the cable's rating.

What is the maximum continuous conductor temperature?

The maximum continuous conductor temperature for these joints is 90 °C.

Are TCJ cable joints suitable for direct-burial applications?

Yes, when assembled, they provide permanent, fully shielded, fully submersible cable joints for direct-burial or vault applications.

Do TCJ joints require field molding or tape wrapping?

No, field molds, wrapping machines, or pre-stretch are not required due to factory molding.

Are TCJ joints factory tested before shipment?

Yes, all TCJ transmission cable joints are factory molded and factory tested to ensure consistent quality and maximum reliability.

What is the AC withstand voltage for 138 kV systems?

For 138 kV nominal systems, the AC withstand voltage is 190 kV for 15 minutes.

Frequently Asked Questions about ABB - Installation Products

How are Thomas and Betts products typically installed?

Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.

What accessories are available for Thomas and Betts products?

Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.

What environmental ratings do Thomas and Betts products have?

Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.

What communication protocols do Thomas and Betts products support?

Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.

What are the key features of Thomas and Betts products?

Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.

What are the main product lines offered by Thomas and Betts?

Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.

What technical support does Thomas and Betts offer?

Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.

What industries and applications are Thomas and Betts products used for?

Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.

What certifications and standards do Thomas and Betts products comply with?

Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.

What are the main product lines offered by Ocal?

Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.