ABB Installation Products 15PCJ1G2210 15kV, Power Cable Joint, Single Piece Housing, Cable Insulation .760-.950 inches, Copper…
UPC: 075114289306
Contact for Pricing
Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.
Overview
- 15kV voltage rating per IEEE Standard 404
- Single-piece housing for straight splice applications
- Accommodates 0.760" to 0.950" cable insulation diameters
- Copper compression lug for #2 AWG compact/solid conductors
- Fully shielded, fully submersible, and deadfront construction
Specifications
Application | For Direct Burial, Vault, Submersible and Other Severe Service Applications |
Color | Black |
Conductor Range | #3 STR AWG , #2 SOL AWG |
Connection | Compression |
Connection Type | Copper Compression Lug |
Insulation | Yes |
Material | EPDM Rubber |
Mounting Type | Single Piece Housing |
Number Of Conductors | 2 |
Size | 10-1/4 inch long |
Size | 0.760-0.950 inches |
Special Features | Power Cable Joints utilize permanently crimped connectors. PCJ housings are fully insulated, shielded and sealed for direct-burial, vault, submersible and other servere service applications. Units have been designed and tested per IEEE Standard 404 to ensure system matched performance and ratings equal to the cable to which the splice will be installed. Power Cable Joints are available in two styles. Style 1 uses a single-piece housing that is sized to accommodate a specific range of cable - ideally suited to straight splicing of the same or similar cable. Style 2 designs incorporate a universal housing with separate cable adapters to allow transition splices of different types and sizes of cable |
Standard | IEEE Standard 404 |
Type | Power Cable Joint |
Voltage Rating | 15 kV |
Package Dimensions (L x W x H) | 0.01 IN x 0.01 IN x 0.01 IN |
Package Dimensions (L x W x H) | 0.0254 cm x 0.0254 cm x 0.0254 cm |
Package Weight (Imperial) | 1.0000 L |
Package Weight (Metric) | 0.4540 kg |

15PCJ1F1210
15kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 0.640 inch to 0.820 inch. Aluminum Conductor. Conductor Size AWG Stranded #3/Solid #2.
138TCJS44246P5LBLNN
138kV, Transmission Joint Cable, Shieldbreak Housing, Housing Style 4, Housing Size 4. Copper Connector, Connector Size 1.328-1.377 inch (33.73-34.98mm). HeatShrink Size 2.750 inch (69.86mm). HeatShrink Bore 1.406 inches, Shield - Copper Neutral Wire, Metallic Screen Continuity Kit - 4/0 Bonding Cable, 6 foot, Quantity 4, without Split Bolts, Armor Kit is not Required, Outer Jacket Restoration Kit is not Required
15PCJ2J1240
15kV, Power Cable Joint, Style 2 with Universal Housing and Separate Cable Adapters that can be varied with the Cable Application, Insulation Diameter .980-1.180 inches, Aluminum Conductor, Conductor Size 1/0 Stranded/Compressed or 2/0 Solid/Compact.
15PCJ2J2290-H2270
15kV, Power Cable Joint, with Universal Housing and separate Cable Adapters that can be varied with the cable application, Cable Insulation .980-1.180 inches, Copper Compression Lug, Conductor Size 350 Compact/Solid to Cable Insulation .850-1.050 inches, Copper Compression Lug, Conductor Size 4/0 Stranded/Compressed or 250 Compact/Solid
15PCJ1N1410
15kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 1.515 inch to 1.780 inch. Aluminum Conductor. Conductor Size AWG Stranded 1000.
15PCJ1M1400
15 kV, Power Cable Joint, Style 1 - 14-3/8 X 2-25/32 inches, Cable Insulation Diameter - 1.370-1.630 inches, Aluminum Connector, Conductor Size - 1000 kcmil.
25PCJ1H1280
25kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 0.850 inch to 1.050 inch. Aluminum Conductor. Conductor Size AWG Stranded 250
35PCJ1-H
35kV, PCJ - Power Cable Joint, with Single Piece Housing, Cable Insulation Diameter .850 - 1.050 inches, Housing OnlyFrequently Asked Questions
What is the maximum operating voltage for this cable joint?
This power cable joint is rated for 15kV (kilovolts) of operating voltage.
What cable insulation diameters does this joint accommodate?
The joint is designed to fit cable insulation diameters ranging from .760 inches to .950 inches.
What conductor size is compatible with the copper compression lug?
The copper compression lug is designed for #2 AWG compact or solid conductors.
What type of housing does this ABB cable joint feature?
This ABB power cable joint features a single-piece housing.
How to Install a Single Core Cable Joint (15PCJ1G2210)
This guide provides step-by-step instructions for the permanent, fully screened, and submersible installation of a single core joint (15PCJ1G2210) on extruded solid dielectric cables. Ensure all safety precautions are followed.
Estimated time: 2h
Tools needed:
Wire brush, Crimping tool, Cleaning solvent, Clean cloth, Sanding tool, Heat gun, Soldering iron (or constant force spring installation tool), Measuring tape/ruler
Supplies needed:
Joint Housing (15PCJ1G2210), PVC tape (multiple colors), Conductor compression connector (copper or aluminum), Lubricant (supplied with joint), Mastic tape, Flat copper braid, Constant force springs (if not soldering), Heat shrink tube (supplied with joint)
- Prepare Cables and Remove Jacket/Metallic Shield
DANGER: Ensure all apparatus is de-energized during installation. Train the cables into their final position, leaving approximately 5mm between them. Store the heat shrink tube on either cable. Remove the jackets of both cables to the dimensions specified in the documentation (e.g., 405mm for Size A). Carefully remove the cable metallic tape screen for the specified distance (e.g., 125mm for Size A) and secure the ends with PVC tape, ensuring it does not overlap onto the non-metallic screen.
- Remove Non-Metallic Screen and Prepare Insulation
WARNING: Do not nick, cut, or damage the insulation surface or conductor strands. Carefully remove the cable non-metallic screen from both cables to the point specified (e.g., 45mm for Size D). Bevel the edge of Cable 1. Cut the insulation to the conductor to dimension 'E' (e.g., 150mm for Size E) from the end of both cables, but DO NOT remove the insulation. Install a PVC tape marker on Cable 2 to dimension 'B' (e.g., 155mm) to locate the splice later.
- Temporarily Store Joint Housing
WARNING: The forward edge and any other sharp edges of the metallic screen must be covered with PVC tape to prevent damage to the joint housing. Apply one layer (half-lapped) of PVC tape over the metallic screen, beginning at the jacket and extending 10mm beyond the end of the metallic screen. Install a different color PVC tape marker on Cable 1 to dimension 'B' (e.g., 155mm). Lubricate both cable entrances of the splice housing. Clean and lubricate the insulation, cable non-metallic screen, and PVC taped portion of the cable metallic tape screen on Cable 1. Store the housing onto Cable 1 up to the jacket; DO NOT store the splice housing on the exposed metallic tape shield.
- Remove Cable Insulation
Remove cable insulation from both cables to dimension 'E' (e.g., 45mm). Exercise extreme caution to avoid cutting or nicking the cable insulation or conductor during this process.
- Install Conductor Connector
Wire brush the exposed conductors of both cables. Immediately insert both conductors fully into the conductor splice, ensuring they are fully seated. Check the distance between insulations; if it exceeds the 'Before' dimension (e.g., 108mm), DO NOT PROCEED, review instructions and redo assembly. Crimp the conductor splice according to the provided crimp chart. Remove any sharp protrusions or burrs. Metal chips or filings must be removed from the splice joint assembly area. Wipe off all excess inhibitor. Re-check the distance between cable insulations; if it exceeds the 'After' dimension (e.g., 102mm), DO NOT PROCEED, review instructions and redo assembly.
- Clean and Lubricate Core
WARNING: Remove all contaminants from the surface of the insulation. Clean the conductor, connector, and Cable 2 insulation surfaces with cleaning solvent and a clean cloth, always wiping towards the screen end. Lubricate cable insulation surfaces using the supplied lubricant, always wiping toward the screen end to provide a build-up or ramp of lubricant at the edge of the non-metallic screen.
- Install Joint Housing
Slide the joint housing over the crimp connector into its final position. Measure the distance 'X' between the joint housing and the PVC tape marker on each side; ensure these distances are equal. Remove the PVC tape applied in Step C to expose 25mm of copper tape.
- Restore Screen
Wrap flat copper braid around each joint housing, continuing the ends over the metallic tape screen for 20mm on each side. Attach each end of the copper braid to the metallic tape screen by either soldering or using a constant force spring.
- Restore Outer Jacket
Lightly sand the outer surface of the jacket of both cables for a distance of 130mm. Heat both sanded areas for approximately 15 seconds, being careful NOT to burn the cables. Wrap two layers of mastic tape at the edge of the jacket on both cables. Position the heat shrink tube from Cable 1 over the center of the assembly and shrink it, starting at the center and working toward the ends.
Frequently Asked Questions about ABB - Installation Products
How are Thomas and Betts products typically installed?
Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.
What accessories are available for Thomas and Betts products?
Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.
What environmental ratings do Thomas and Betts products have?
Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.
What communication protocols do Thomas and Betts products support?
Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.
What are the key features of Thomas and Betts products?
Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.
What are the main product lines offered by Thomas and Betts?
Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.
What technical support does Thomas and Betts offer?
Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.
What industries and applications are Thomas and Betts products used for?
Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.
What certifications and standards do Thomas and Betts products comply with?
Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.
What are the main product lines offered by Ocal?
Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.