Authorized ABB Distributor (Installation Products)
ABB - Installation Products 15PCJ2G1220 - 15kV Power Cable Joint Style 2 with Universal Housing and Separate Cable Adapters. Cable Insulation Diameter 0.760 inch to 0.950 inch. Aluminum Conductor. Conductor Size AWG Stranded #2/Solid #1.

ABB Installation Products 15PCJ2G1220 15kV Power Cable Joint Style 2 with Universal Housing and Separate Cable Adapters. Cable…

UPC: 075114239028


Documents & Media
BrochureInstallation InstructionsSpecification SheetManufacturer Product Website

Contact for Pricing

Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.

Overview

ABB Installation Products 15kV Power Cable Joint Style 2 (SKU: 15PCJ2G1220) is a high-voltage cable joint designed for 15kV class power distribution systems. This joint features a universal housing compatible with aluminum conductors sized AWG #2 stranded or solid #1, supporting cable insulation diameters from 0.760 inch to 0.950 inch. The joint accommodates stranded #2 or solid #1 aluminum conductors, providing flexibility for common medium-voltage distribution applications. The universal housing design allows for separate cable adapters, enabling installation on varying cable constructions without requiring custom housings. This reduces inventory complexity and simplifies field deployment. The joint is rated for 15kV service, meeting the demands of medium-voltage power systems in industrial, commercial, and utility applications. Typical applications include: - Medium-voltage power distribution in industrial facilities - Utility substation interconnections - Commercial building power feeds - Renewable energy integration projects The joint’s design ensures reliable electrical continuity and mechanical integrity in harsh environments, including exposure to moisture, temperature fluctuations, and mechanical stress. Installation follows standard medium-voltage jointing procedures, with clearances and creepage distances compliant with applicable industry standards.
  • Rated for 15kV medium-voltage applications
  • Universal housing with separate cable adapters for AWG #2 stranded or solid #1 aluminum conductors
  • Supports cable insulation diameters from 0.760 inch to 0.950 inch
  • Designed for reliable electrical continuity in industrial and utility environments
  • Compatible with standard medium-voltage jointing procedures

Specifications

Application
For Direct Burial, Vault, Submersible and Other Severe Service Applications
Color
Black
Conductor Range
#4 STR AWG , #3 SOL AWG , #2 STR AWG , #1 SOL AWG
Connection
Compression
Connection Type
Universal Housing and Separate Cable Adapters
Insulation
Yes
Material
Aluminum
Material
EPDM Rubber
Number Of Conductors
2
Series
Style 2
Size
16-3/8 inch long
Size
Cable Insulation Diameter 0.760 inch to 0.950 inch
Special Features
Power Cable Joints utilize permanently crimped connectors. PCJ housings are fully insulated, shielded and sealed for direct-burial, vault, submersible and other servere service applications. Units have been designed and tested per IEEE Standard 404 to ensure system matched performance and ratings equal to the cable to which the splice will be installed. Power Cable Joints are available in two styles. Style 1 uses a single-piece housing that is sized to accommodate a specific range of cable - ideally suited to straight splicing of the same or similar cable. Style 2 designs incorporate a universal housing with separate cable adapters to allow transition splices of different types and sizes of cable
Standard
IEEE Standard 404
Type
Power Cable Joint
Voltage Rating
15 kV
Package Dimensions (L x W x H)
0.01 IN x 0.01 IN x 0.01 IN
Package Dimensions (L x W x H)
0.0254 cm x 0.0254 cm x 0.0254 cm
Package Weight (Imperial)
1.0000 L
Package Weight (Metric)
0.4540 kg
15kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 0.640 inch to 0.820 inch. Copper Conductor. Conductor Size AWG Stranded #4/Solid #3.

15PCJ1F2200

15kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 0.640 inch to 0.820 inch. Copper Conductor. Conductor Size AWG Stranded #4/Solid #3.
15kV, Power Cable Joint, Single Piece Housing, Cable Insulation .760-.950 inches, Copper Compression Lug, Conductor Size #2 Compact/Solid.

15PCJ1G2210

15kV, Power Cable Joint, Single Piece Housing, Cable Insulation .760-.950 inches, Copper Compression Lug, Conductor Size #2 Compact/Solid.
138kV, Transmission Joint Cable, Shieldbreak Housing, Housing Style 4, Housing Size 4. Copper Connector, Connector Size 1.328-1.377 inch (33.73-34.98mm). HeatShrink Size 2.750 inch (69.86mm). HeatShrink Bore 1.406 inches, Shield - Copper Neutral Wire, Metallic Screen Continuity Kit - 4/0 Bonding Cable, 6 foot, Quantity 4, without Split Bolts, Armor Kit is not Required, Outer Jacket Restoration Kit is not Required

138TCJS44246P5LBLNN

138kV, Transmission Joint Cable, Shieldbreak Housing, Housing Style 4, Housing Size 4. Copper Connector, Connector Size 1.328-1.377 inch (33.73-34.98mm). HeatShrink Size 2.750 inch (69.86mm). HeatShrink Bore 1.406 inches, Shield - Copper Neutral Wire, Metallic Screen Continuity Kit - 4/0 Bonding Cable, 6 foot, Quantity 4, without Split Bolts, Armor Kit is not Required, Outer Jacket Restoration Kit is not Required
15kV, Power Cable Joint, Style 2 with Universal Housing and Separate Cable Adapters that can be varied with the Cable Application, Insulation Diameter .980-1.180 inches, Aluminum Conductor, Conductor Size 1/0 Stranded/Compressed or 2/0 Solid/Compact.

15PCJ2J1240

15kV, Power Cable Joint, Style 2 with Universal Housing and Separate Cable Adapters that can be varied with the Cable Application, Insulation Diameter .980-1.180 inches, Aluminum Conductor, Conductor Size 1/0 Stranded/Compressed or 2/0 Solid/Compact.
15kV, Power Cable Joint, with Universal Housing and separate Cable Adapters that can be varied with the cable application, Cable Insulation .980-1.180 inches, Copper Compression Lug, Conductor Size 350 Compact/Solid to Cable Insulation .850-1.050 inches, Copper Compression Lug, Conductor Size 4/0 Stranded/Compressed or 250 Compact/Solid

15PCJ2J2290-H2270

15kV, Power Cable Joint, with Universal Housing and separate Cable Adapters that can be varied with the cable application, Cable Insulation .980-1.180 inches, Copper Compression Lug, Conductor Size 350 Compact/Solid to Cable Insulation .850-1.050 inches, Copper Compression Lug, Conductor Size 4/0 Stranded/Compressed or 250 Compact/Solid
15kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 1.515 inch to 1.780 inch. Aluminum Conductor. Conductor Size AWG Stranded 1000.

15PCJ1N1410

15kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 1.515 inch to 1.780 inch. Aluminum Conductor. Conductor Size AWG Stranded 1000.
15 kV, Power Cable Joint, Style 1 - 14-3/8 X 2-25/32 inches, Cable Insulation Diameter - 1.370-1.630 inches, Aluminum Connector, Conductor Size - 1000 kcmil.

15PCJ1M1400

15 kV, Power Cable Joint, Style 1 - 14-3/8 X 2-25/32 inches, Cable Insulation Diameter - 1.370-1.630 inches, Aluminum Connector, Conductor Size - 1000 kcmil.
25kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 0.850 inch to 1.050 inch. Aluminum Conductor. Conductor Size AWG Stranded 250

25PCJ1H1280

25kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 0.850 inch to 1.050 inch. Aluminum Conductor. Conductor Size AWG Stranded 250

Frequently Asked Questions

What are Elastimold PCJ power cable joints used for?

They are used for straight splicing of two similar cables or transition splicing of different cable sizes, up to 1250 kcmil, in new or existing installations.

What industry standards do PCJ joints meet?

The shield design meets IEEE 592 standard, and connectors meet ANSI 119.4 Class A and Class 3 ratings. Electrical ratings meet IEEE 404.

What pull force can the interlock withstand?

The pin-and-socket interlock of the PCJ power cable joints is designed to withstand a pull force of up to 500 lb.

What is the maximum conductor size supported?

PCJ power cable joints support conductor sizes up to 1250 kcmil for both stranded/compressed and compressed/solid types.

What is the short-time current rating?

The short-time current rating for PCJ power cable joints is equal to that of the cable rating, up to 35 kA.

What is the continuous current rating?

The continuous current rating for PCJ power cable joints is equal to that of the cable rating.

Which connector material should I use?

Aluminum compression connectors are for aluminum-to-aluminum or aluminum-to-copper. Copper compression connectors are for copper-to-copper only and must not be used on aluminum.

What are the two styles of PCJ power cable joints?

Style 1 is for straight splicing of two similar cables. Style 2 includes separate cable adapters for transition splicing between two different cable sizes.

What types of conductors are compatible with PCJ joints?

PCJ joints can be used with copper or aluminum conductors, accommodating a wide range of sizes up to 1250 kcmil.

What voltage classes are available for PCJ joints?

Elastimold PCJ power cable joints are available in 15 kV, 25 kV, and 35 kV classes.

How to Install the 15/25/35PCJ2W Cable Joint

This guide provides detailed instructions for the permanent, fully shielded, and submersible installation of the 15/25/35PCJ2W series straight joint for aluminum and/or copper conductor, wire shielded cables. Ensure all apparatus is de-energized before beginning.

Estimated time: 2h

Tools needed:

Wire strippers, Circular cutting tool, Glass scraper, Wirebrush, Hex wrench, Crimping tool

Supplies needed:

Joint Housing, Splice (Conductor Contact), Cable Adapters, Lubricant, Retaining Collars, Hose Clamp, Electrical tape, #14 AWG copper wire (or equivalent), Appropriate connector (user supplied), Heat/cold shrink jacket (user supplied)

  1. Perform Safety Checks and Initial Preparation

    DANGER: Ensure all apparatus is de-energized before installation or removal. Inspect all components for damage, rating, and compatibility. Examine mating cable ends for moisture and contaminants. Remove graphite coatings 12 inches (30.5cm) beyond the cable jacket cut using a circular cutting tool or glass scraper; avoid sanding. If conductors contain strand filled or water-blocking material, contact the cable manufacturer for welding/crimping procedures.

  2. Prepare Cable Jackets and Position Housing

    Using a stripping guide, carefully remove the cable jacket of both cables for a distance of 11-1/4 inches (285.7mm). Fold back the shield wires and tape the end of the wires on Cable 1, allowing enough extra length to rejoin later. Clean the surface of the insulation shield, shield wires, and jacket for a distance of 30 inches (760mm). Slide the joint housing onto Cable 1 to a distance of 30 inches (760mm).

  3. Prepare Cable Insulation

    Using the stripping guide, carefully remove the insulation shield and cable insulation. CAUTION: DO NOT CUT OR NICK THE INSULATION, as this could lead to assembly failure. Wrap two turns of tape 1 inch (25mm) from the edge of the insulation shield on both cables to serve as a marker. Clean the cable insulation thoroughly, then lubricate it to create a build-up or ramp of lubricant at the edge of the insulation shield.

  4. Install Cable Adapters and Retaining Collars

    Lubricate the inside of both ends of one cable adapter. Install this cable adapter onto Cable 1 until it meets the tape marker. Repeat this process for the other cable adapter on Cable 2. Select the retaining collars and partially thread the proper size setscrews. Position each retaining collar over the insulation, flush against its respective cable adapter. Using the supplied hex wrench, tighten each set screw one or two turns at a time to keep the collar centered, then continue tightening until the screws are below the collar surface.

  5. Splice Conductors

    Thoroughly clean the ends of the cable adapters and the cable where shown. Install a hose clamp around the adapter on the opposite side of the splice from where the housing is stored to hold the adapter in place. Tape over the hose clamp to form a smooth surface. Wirebrush the exposed conductors of both cables and immediately insert them into the splice. Verify the 'Check' dimension does not exceed 8-1/2 inches (215mm); redo assembly if it does. Crimp the splice according to its recommendations. Wipe off all excess inhibitor. Check the distance between cable adapters; redo assembly if it exceeds 8-3/4 inches (222mm). Clean and lubricate the outside surface of the cable adapters.

  6. Complete Joint Assembly and Grounding

    Slide the joint housing into its final position, centering it over the cable adapters. Remove all tape, ensuring that no cable or adapter insulation is exposed after positioning the joint. Reshape the shield wires and secure them to the ends of the joint. Insert one shield wire from Cable 1 (if #14 AWG or larger) through the joint grounding eye, and repeat for Cable 2. If shield wires are smaller than #14 AWG, use separate #14 AWG copper wire or equivalent. Connect the joint grounding wires and remaining shield wires using an appropriate connector. Reconstruct the cable jacket (where applicable) over both cables and over the joint housing using heat/cold shrink materials (not included).

Frequently Asked Questions about ABB - Installation Products

How are Thomas and Betts products typically installed?

Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.

What accessories are available for Thomas and Betts products?

Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.

What environmental ratings do Thomas and Betts products have?

Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.

What communication protocols do Thomas and Betts products support?

Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.

What are the key features of Thomas and Betts products?

Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.

What are the main product lines offered by Thomas and Betts?

Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.

What technical support does Thomas and Betts offer?

Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.

What industries and applications are Thomas and Betts products used for?

Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.

What certifications and standards do Thomas and Betts products comply with?

Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.

What are the main product lines offered by Ocal?

Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.