- 35kV voltage rating, 200 Amp current capacity
- Bi-metal compression lug for 1/0 to 2/0 AWG conductors (53.49 mm²)
- Cable insulation diameter range: 0.980" to 1.180"
- Integrated test point for safe circuit testing without disconnection
- Includes 200ECS jacket seal for environmental protection
- Integrated test point for safe electrical circuit testing
- Designed for quick and safe connection/disconnection of energized equipment
Specifications
Amperage Rating | 200 A |
Application | 35 kv, 200 Amp |
Color | Black |
Conductor Range | 1/0 STR/COMPR AWG , 2/0 SOL/COMPT AWG |
Connection | Push-In |
Connection Type | Bi-Metal Compression Lug |
Connection Type | Compression Lug |
Current Rating | 200 A |
Environmental Conditions | Fully Submersible |
Insulation | True |
Material | Molded Rubber, Bi-Metal (Aluminum/Copper) |
Material | Bi-Metal, Aluminum (Jacket Seal) |
Material | Housing - EPDM-Rubber |
Series | 376LR |
Size | Cable Insulation Diameter 0.980 inch to 1.180 inch |
Size | 0.980" - 1.180" (Cable Insulation Diameter) |
Size | 0.980-1.180 inch (insulation diameter) |
Special Features | 35kV, 200 Amp Loadbreak Elbow. Fully shielded, fully submersible molded rubber housing. 100 percent peroxide-cured construction includes insulation and conductive EPDM materials. Provision for hot stick operation. Provision for ground wire connection. Non-Corrosive Capacitive Voltage Test Point |
Standard | ANSI/IEEE Standard 386 |
Temperature Rating, Maximum | 149 F |
Temperature Rating, Maximum | 65 C |
Temperature Rating, Minimum | -40 F |
Temperature Rating, Minimum | -40 C |
Type | Loadbreak Elbow Connector with Test Point |
Voltage Rating | 35 kV |
Package Dimensions (L x W x H) | 0.01 IN x 0.01 IN x 0.01 IN |
Package Dimensions (L x W x H) | 0.0254 cm x 0.0254 cm x 0.0254 cm |
Package Weight (Imperial) | 3.1000 L |
Package Weight (Metric) | 1.4060 kg |

375LR-H5240
200 Amp, 35kV, Loadbreak Elbow Connector without Test Point, Cable Insulation Diameter 0.850 inch to 1.050 inch. Bi-Metal Compression Lug, Conductor Size AWG Compressed Stranded 1/0 /Solid 2/0 /mmSquared 53.49.
274RLR-K-5240
200 Amp, 25kV, Loadbreak Replacement Elbow Connector with Test Point, Repair Elbow has extended length contact and elbow housing resulting in a net gain of 8-7/8 inches in length. Includes 00400X long Bi-Metal Contact. Cable Insulation Diameter 1.090 inch to 1.310 inch. Bi-Metal Compression Lug, Conductor Size AWG Compressed Stranded 1/0 /Solid 2/0 /mmSquared 53.49.
274RLR-G-5210
25kV 200 Amp, Loadbreak Replacement Elbow Connector with Test Point. Cable Insulation Diameter 0.760 inch to 0.950 inch. Bi-Metal Compression Lug. Conductor Size AWG Compressed Stranded #3/Solid #2/mmSquared 26.67.
167RLRG5260
200 Amp, 15kV, Loadbreak Replacement Elbow Connector without Test Point, Cable Insulation Diameter 0.760 inch to 0.950 inch. Bi-Metal Compression Lug, Conductor Size AWG Compressed Stranded 3/0 /Solid 4/0 /mmSquared 85.01. Repair Elbow has extended length contact and elbow housing resulting in a net gain of 8-7/8 inches in length. Includes 00400X long Bi-Metal Contact.
168RLR-F-5230
200 Amp, 15kV, Loadbreak Replacement Elbow Connector with Test Point, Cable Insulation Diameter 0.640 inch to 0.820 inch. Bi-Metal Compression Lug, Conductor Size AWG Compressed Stranded #1/Solid 1/0 /mmSquared 42.41. Repair Elbow has extended length contact and elbow housing resulting in a net gain of 8-7/8 inches in length. Includes 00400X long Bi-Metal Contact.
168RLR-H5230
15kV 200 Amp, Loadbreak Replacement Elbow Connector with Test Point. Cable Insulation Diameter 0.850 inch to 1.050 inch. Bi-Metal Compression Lug. Conductor Size AWG Compressed Stranded #1/Solid 1/0 /mmSquared 42.41.
376LR-K-5260
35kV 200 Amp, Loadbreak Elbow Connector with Test Point, Cable Insulation Diameter 1.090 inch to 1.310 inch. Bi-Metal Compression Lug. Conductor Size AWG Compressed Stranded 3/0 /Solid 4/0 /mmSquared 85.01.
168RLR-F-5250
200 Amp, 15kV, Loadbreak Replacement Elbow Connector with Test Point, Cable Insulation Diameter 0.640 inch to 0.820 inch. Bi-Metal Compression Lug, Conductor Size AWG Compressed Stranded 2/0 /Solid 3/0 /mmSquared 67.43. Repair Elbow has extended length contact and elbow housing resulting in a net gain of 8-7/8 inches in length. Includes 00400X long Bi-Metal Contact.Frequently Asked Questions
What is the voltage rating of this elbow connector?
The 376LR Loadbreak Elbow Connector is rated for 35kV voltage class, with a maximum phase-to-ground operating voltage of 21.1kV.
What is the one-minute AC withstand voltage?
The one-minute AC withstand voltage rating for the connector is 50kV AC.
What is the impulse withstand rating?
The impulse withstand rating is 150kV BIL (Basic Impulse Level) with a 1.2 x 50 microsecond wave.
What is the 15-minute DC withstand voltage?
The 15-minute DC withstand voltage rating for the connector is 103kV DC.
What is the corona extinction voltage?
The corona extinction voltage is 26kV AC at 3p.C. sensitivity.
What is included in the 376LR kit?
Each kit contains an elbow connector housing, a bi-metal compression lug, a probe, a probe wrench, lubricant, installation instructions, and a crimp chart.
What types of conductors are compatible with the lugs?
The standard bi-metal compression lug is suitable for both copper and aluminum conductors. Copper lugs are for copper conductors only.
What type of housing does the connector have?
The connector features a fully shielded, fully submersible molded rubber housing made of 100% peroxide-cured EPDM materials.
Does the elbow connector have a test point?
Yes, the 376LR is equipped with a non-corrosive capacitive voltage test point.
What standards does the 376LR meet?
The 376LR Loadbreak Elbow Connector meets ANSI/IEEE Standard 386, Latest Revision.
How to Install 375LR/376LR Loadbreak Elbow Connectors
This guide provides step-by-step instructions for the safe and proper installation of Elastimold 375LR and 376LR Loadbreak Elbow Connectors, including cable preparation and assembly.
Estimated time: 1h 30m
Tools needed:
Probe Wrench, Wire brush, Crimp tool, Wire strippers, Hotstick
Supplies needed:
Elbow Connector Housing, Compression Lug, Probe, Lubricant (Do Not Substitute), No. 14 AWG / 2.5mm copper wire, Grounding connector, HV insulated cap(s) or connector(s) (if replacing shipping covers)
- De-energize and Inspect Components
DANGER: Ensure all apparatus is de-energized before starting installation. Inspect all components (Elbow Connector Housing, Compression Lug, Probe) for damage, rating, and compatibility. Check package contents for completeness and verify proper fit with cable and/or mating products. Thread the probe into the compression lug by hand to check for resistance; replace damaged components if resistance is encountered. Have all required tools ready and maintain cleanliness throughout the procedure.
- Prepare the Cable
Train the cable (20 inches minimum beyond end of cable pad mount transformer) for ease of operation. Cut excess cable squarely at the bushing's center line. Unwrap and bind concentric neutral wires 8-1/2 inches back. Remove shield and insulation from the cable end, cutting squarely without nicking the conductor. Wire brush bare aluminum conductors and immediately install the compression lug, rotating to spread inhibitor. Align the lug's threaded hole with the bushing bore. Crimp the lug per the crimp chart, starting at the mark and rotating 180 degrees for each crimp. Wipe excess inhibitor from the lug and cable. Remove the insulation shield and bevel the insulation end 1/8 inch maximum. Thoroughly clean insulation to remove all conductive residue.
- Assemble the Elbow Connector
Lubricate the cable insulation and the inside of the elbow housing with the supplied lubricant. DO NOT SUBSTITUTE, as other lubricants may be harmful. Slide the elbow connector onto the cable with a back-and-forth twisting motion. Wipe off all excess grease. Align the elbow with the compression lug's threaded hole. Thread the probe into the lug by hand, ensuring it turns freely for approximately four turns before becoming snug. Tighten the probe with the probe wrench until the wrench bends.
- Connect Concentric Neutral Wires
Using a separate copper wire (No. 14 AWG / 2.5mm or equivalent), insert one end through the grounding eye on the elbow. Twist it tight, taking care not to damage the eye. Twist all neutral wires together and connect them to ground using an appropriate connector. Provide adequate slack in the neutral wires for proper elbow operation.
- Prepare for Bushing Connection
CAUTION: Lubricate the receptacle portion of the elbow connector and the mating bushing with the supplied lubricant ONLY IF THE TRANSFORMER AND ELBOW ARE KNOWN TO BE DE-ENERGIZED. If the product was supplied with protective shipping cover(s), remove them and replace with the appropriate HV insulated cap(s) or connector(s) before submerging or energizing the circuit.
Frequently Asked Questions about ABB - Installation Products
How are Thomas and Betts products typically installed?
Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.
What accessories are available for Thomas and Betts products?
Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.
What environmental ratings do Thomas and Betts products have?
Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.
What communication protocols do Thomas and Betts products support?
Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.
What are the key features of Thomas and Betts products?
Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.
What are the main product lines offered by Thomas and Betts?
Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.
What technical support does Thomas and Betts offer?
Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.
What industries and applications are Thomas and Betts products used for?
Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.
What certifications and standards do Thomas and Betts products comply with?
Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.
What are the main product lines offered by Ocal?
Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.