ABB - Installation Products 375LR-H5240 - 200 Amp, 35kV, Loadbreak Elbow Connector without Test Point, Cable Insulation Diameter 0.850 inch to 1.050 inch. Bi-Metal Compression Lug, Conductor Size AWG Compressed Stranded 1/0 /Solid 2/0 /mmSquared 53.49.

ABB Installation Products 375LR-H5240 200 Amp, 35kV, Loadbreak Elbow Connector without Test Point, Cable Insulation Diameter…

UPC: 783786277841


Documents & Media
BrochureInstallation InstructionsSpecification SheetManufacturer Product Website

Contact for Pricing

Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.

Overview

The ABB 375LR-H5240 is a 200 Amp, 35kV loadbreak elbow connector designed for medium-voltage power distribution applications in underground systems, substations, and industrial networks. This model is specifically engineered without a test point, making it ideal for installations where test point functionality is unnecessary, thus simplifying the connector’s design while maintaining high performance standards. The connector supports cable insulation diameters ranging from 0.850 inches to 1.050 inches, ensuring compatibility with a defined range of medium-voltage cables commonly used in power distribution. Its bi-metal compression lug provides a secure termination solution for compressed stranded conductors sized at AWG 1/0 or solid conductors sized at AWG 2/0, with a corresponding cross-sectional area of 53.49 mm². The bi-metal construction enhances electrical conductivity and mechanical strength, delivering long-term reliability in demanding operating conditions. This loadbreak elbow connector is a critical component for maintaining safe and efficient power flow in medium-voltage distribution systems, offering durability and performance in harsh environments. Manufactured by ABB - Installation Products, the 375LR-H5240 is identified by SKU 375LR-H5240 and classified under UNSPSC Code 39121421.
  • 200 Amp, 35kV loadbreak elbow connector
  • Accommodates cable insulation diameters 0.850" to 1.050"
  • Bi-metal compression lug for AWG 1/0 (compressed stranded) or AWG 2/0 (solid) conductors
  • Excludes test point for simplified configuration
  • Designed for underground distribution, substations, and industrial power networks

Specifications

Amperage Rating
200 A
Application
35 kv, 200 Amp
Color
Black
Conductor Range
1/0 STR/COMPR AWG , 2/0 SOL/COMPT AWG
Connection
Push-In
Connection Type
LoadBreak Elbow Connector
Current Rating
200 A
Environmental Conditions
Fully Submersible
Insulation
True
Material
Bi-Metal Compression Lug
Material
Housing - EPDM-Rubber
Series
375LR
Size
Cable Insulation Diameter 0.850 inch to 1.050 inch
Special Features
35kV, 200 Amp Loadbreak Elbow. Fully shielded, fully submersible molded rubber housing. 100 percent peroxide-cured construction includes insulation and conductive EPDM materials. Provision for hot stick operation. Provision for ground wire connection
Standard
ANSI/IEEE Standard 386
Temperature Rating, Maximum
149 F
Temperature Rating, Maximum
65 C
Temperature Rating, Minimum
-40 F
Temperature Rating, Minimum
-40 C
Type
Loadbreak Elbow Connector
Voltage Rating
35 kV
Package Dimensions (L x W x H)
0.01 IN x 0.01 IN x 0.01 IN
Package Dimensions (L x W x H)
0.0254 cm x 0.0254 cm x 0.0254 cm
Package Weight (Imperial)
3.1000 L
Package Weight (Metric)
1.4060 kg
35kV 200 Amp, Loadbreak Elbow Connector without Test Point, Cable Insulation Diameter 1.090 inch to 1.310 inch. Bi-Metal Compression Lug. Conductor Size AWG Compressed Stranded 1/0 /Solid 2/0 /mmSquared 53.49.

375LR-K-5240

35kV 200 Amp, Loadbreak Elbow Connector without Test Point, Cable Insulation Diameter 1.090 inch to 1.310 inch. Bi-Metal Compression Lug. Conductor Size AWG Compressed Stranded 1/0 /Solid 2/0 /mmSquared 53.49.
25kV 200 Amp, Loadbreak Replacement Elbow Connector with Test Point. .760 inch - .950 Inch Cable Insulation Diameter, 1/0 Stranded or 2/0 kcmil Solid Wire Size, Bi-Metal Compression Lug.

274RLR-G5240

25kV 200 Amp, Loadbreak Replacement Elbow Connector with Test Point. .760 inch - .950 Inch Cable Insulation Diameter, 1/0 Stranded or 2/0 kcmil Solid Wire Size, Bi-Metal Compression Lug.
35kV 600 Series Deadbreak Elbow with Test Point (with Insulated Plug, Cap, Stud, Lug and Cable Adapter). Aluminum Compression Lug. Cable Insulation Diameter 1.090 inch to 1.310 inch. Conductor Size AWG or kcmil, Compressed Stranded #1 or Compacted Solid 1/0 or mmSquared Compact 50.

756LR-K0230

35kV 600 Series Deadbreak Elbow with Test Point (with Insulated Plug, Cap, Stud, Lug and Cable Adapter). Aluminum Compression Lug. Cable Insulation Diameter 1.090 inch to 1.310 inch. Conductor Size AWG or kcmil, Compressed Stranded #1 or Compacted Solid 1/0 or mmSquared Compact 50.
600 Amp, 35KV, Stick Op Connector Kit with Test Point, Insulated Cap and Reducing Tap Plug. Cable Insulation Diameter 1.725 inch to 1.935 inch. Aluminum Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 700/750 /Compacted Solid 900.

755LRTP-P0380-DRG

600 Amp, 35KV, Stick Op Connector Kit with Test Point, Insulated Cap and Reducing Tap Plug. Cable Insulation Diameter 1.725 inch to 1.935 inch. Aluminum Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 700/750 /Compacted Solid 900.
600 Amp, 35kV, Stick-Op Connector Kit with Test Point, Insulated Cap and Reducing Tap Plug. Cable Insulation Diameter 1.515 inch to 1.780 inch. Aluminum Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 700/750 /Compacted Solid 900.

755LRTP-N0380-DRG

600 Amp, 35kV, Stick-Op Connector Kit with Test Point, Insulated Cap and Reducing Tap Plug. Cable Insulation Diameter 1.515 inch to 1.780 inch. Aluminum Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 700/750 /Compacted Solid 900.
600 Amp, 35kV, Stick-Op Connector Kit with Test Point, Insulated Cap and Reducing Tap Plug. Cable Insulation Diameter 0.980 inch to 1.180 inch. Aluminum Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 1/0 /Compacted Solid 2/0.

755LRTP-J0240-DRG

600 Amp, 35kV, Stick-Op Connector Kit with Test Point, Insulated Cap and Reducing Tap Plug. Cable Insulation Diameter 0.980 inch to 1.180 inch. Aluminum Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 1/0 /Compacted Solid 2/0.
600 Amp, 35kV, 600 Series Deadbreak Elbow (with Insulated Plug, Cap, Stud, Lug and Cable Adapter). Cable Insulation Diameter 1.725 inch to 1.935 inch. Aluminum Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 900 /Compacted Solid 1000 /mmSquared Compact 500. 200ECS-G3 Jacket Seal and Grounding Kit Included.

755LR-P0400-SG3

600 Amp, 35kV, 600 Series Deadbreak Elbow (with Insulated Plug, Cap, Stud, Lug and Cable Adapter). Cable Insulation Diameter 1.725 inch to 1.935 inch. Aluminum Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 900 /Compacted Solid 1000 /mmSquared Compact 500. 200ECS-G3 Jacket Seal and Grounding Kit Included.
200 Amp, 25kV, Loadbreak Replacement Elbow Connector without Test Point, Repair Elbow has extended length contact and elbow housing resulting in a net gain of 8-7/8 inches in length. Includes 00400X long Bi-Metal Contact. Cable Insulation Diameter 1.090 inch to 1.310 inch. Conductor Size AWG Compressed Stranded 4/0 /Solid 250 /mmSquared 126.67.

273RLR-K-5270

200 Amp, 25kV, Loadbreak Replacement Elbow Connector without Test Point, Repair Elbow has extended length contact and elbow housing resulting in a net gain of 8-7/8 inches in length. Includes 00400X long Bi-Metal Contact. Cable Insulation Diameter 1.090 inch to 1.310 inch. Conductor Size AWG Compressed Stranded 4/0 /Solid 250 /mmSquared 126.67.

Frequently Asked Questions

How can I visually identify the voltage class of the bushing insert?

The color-coded PBT interface shield indicates voltage class: red for 15 kV, blue for 25 kV, and black for 35 kV.

What voltage classes are the bushing inserts designed for?

The Elastimold bushing inserts are designed for 25 kV and 35 kV system voltages.

What voltage classes do the loadbreak elbows support?

The Elastimold 200 amp loadbreak elbows are designed for 15 kV and 25 kV series systems.

How can I visually identify the voltage class of the bushing insert?

The color-coded PBT interface shield indicates voltage class: red for 15 kV, blue for 25 kV, and black for 35 kV.

What voltage classes are the bushing inserts designed for?

The Elastimold bushing inserts are designed for 25 kV and 35 kV system voltages.

What voltage classes do the loadbreak elbows support?

The Elastimold 200 amp loadbreak elbows are designed for 15 kV and 25 kV series systems.

How can I visually identify the voltage class of the bushing insert?

The color-coded PBT interface shield indicates voltage class: red for 15 kV, blue for 25 kV, and black for 35 kV.

What voltage classes are the bushing inserts designed for?

The Elastimold bushing inserts are designed for 25 kV and 35 kV system voltages.

What voltage classes do the loadbreak elbows support?

The Elastimold 200 amp loadbreak elbows are designed for 15 kV and 25 kV series systems.

What voltage classes are the bushing inserts designed for?

The Elastimold bushing inserts are designed for 25 kV and 35 kV system voltages.

How to Install Elastimold 375LR/376LR Loadbreak Elbow Connectors

This guide provides step-by-step instructions for the safe and proper installation of Elastimold 375LR (without test point) and 376LR (with test point) Loadbreak Elbow Connectors on UD cable.

Estimated time: 1h 30m

Tools needed:

Cable cutter, Cable cut back template, Wire brush, Crimp tool, Probe wrench, Cleaning cloths or wipes, Hotstick

Supplies needed:

Elbow Connector Housing (375LR or 376LR), Compression Lug, Probe, Lubricant (supplied, DO NOT SUBSTITUTE), Copper wire (No. 14 AWG / 2.5mm), Grounding connector, UD Cable (concentric neutral, extruded insulation shielding), HV insulated cap(s) or connector(s) (if replacing shipping covers)

  1. Perform Initial Component Checks and Prepare for Installation

    DANGER: All apparatus must be de-energized during installation. Before starting, check the package contents to ensure they are complete and undamaged. Verify all components fit properly with the cable and/or mating products. Thread the probe into the compression lug to check for resistance; if encountered, replace damaged components. If the product was supplied with protective shipping covers, remove them and replace with appropriate HV insulated caps or connectors before proceeding.

  2. Prepare the Cable for Training

    Train the UD cable as shown to ease operation, ensuring a minimum of 20 inches beyond the end of the cable pad mount transformer. Cut excess cable squarely at the center line of the bushing.

  3. Prepare the Cable End

    Unwrap and bind concentric neutral wires 8-1/2 inches back from the end of the cable. Remove the shield and insulation from the cable end, cutting squarely and taking care not to nick the conductor. Wire brush bare aluminum conductors thoroughly.

  4. Install and Crimp the Compression Lug

    Immediately install the compression lug onto the wire-brushed conductor, rotating it to spread the inhibitor. Position the compression lug so its contact threaded hole aligns with the bushing bore. Crimp the lug according to the crimp chart, starting at the crimp line mark and rotating 180 degrees for each successive crimp. Carefully wipe any excessive inhibitor from the outside of the lug and cable.

  5. Finish Cable Insulation Preparation

    Remove the insulation shield as shown in the template. Bevel the insulation end a maximum of 1/8 inch. Thoroughly clean the insulation to remove all traces of conductive residue, ensuring a straight, smooth, and squared finish without nicks.

  6. Assemble the Elbow Connector

    Lubricate the cable insulation and the inside of the elbow housing with the supplied lubricant; DO NOT SUBSTITUTE. Slide the elbow connector onto the cable with a back-and-forth twisting motion, then wipe off all excess grease. Align the elbow with the compression lug’s threaded hole.

  7. Install and Tighten the Probe

    Thread the probe into the lug by hand, ensuring not to cross-thread. The probe must turn freely for approximately four turns before becoming snug. Tighten the probe with the probe wrench until the wrench bends, indicating proper torque.

  8. Connect the Concentric Neutral Wires

    Insert one end of a separate No. 14 AWG (2.5mm) copper wire or equivalent through the grounding eye on the elbow and twist it tight, taking care not to damage the eye. Twist all neutral wires together and connect them to ground using an appropriate connector, providing adequate slack for elbow operation.

  9. Lubricate and Connect the Elbow to the Bushing

    DANGER: Ensure the transformer and elbow are DE-ENERGIZED before proceeding. Lubricate the receptacle portion of the elbow connector and the mating bushing with the supplied lubricant. Securely fasten a hotstick to the loadbreak connector pulling eye. Insert the probe tip approximately 2 inches into the bushing, then immediately push the elbow home with a fast, firm, straight motion, applying sufficient force to engage the internal lock on the elbow connector and bushing interface. DO NOT OPERATE BY HAND.

Frequently Asked Questions about ABB - Installation Products

How are Thomas and Betts products typically installed?

Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.

What accessories are available for Thomas and Betts products?

Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.

What environmental ratings do Thomas and Betts products have?

Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.

What communication protocols do Thomas and Betts products support?

Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.

What are the key features of Thomas and Betts products?

Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.

What are the main product lines offered by Thomas and Betts?

Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.

What technical support does Thomas and Betts offer?

Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.

What industries and applications are Thomas and Betts products used for?

Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.

What certifications and standards do Thomas and Betts products comply with?

Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.

What are the main product lines offered by Ocal?

Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.