Authorized ABB Distributor (Installation Products)
ABB - Installation Products 274RLR-K-5240 - 200 Amp, 25kV, Loadbreak Replacement Elbow Connector with Test Point, Repair Elbow has extended length contact and elbow housing resulting in a net gain of 8-7/8 inches in length. Includes 00400X long Bi-Metal Contact. Cable Insulation Diameter 1.090 inch to 1.310 inch. Bi-Metal Compression Lug, Conductor Size AWG Compressed Stranded 1/0 /Solid 2/0 /mmSquared 53.49.

ABB Installation Products 274RLR-K-5240 200 Amp, 25kV, Loadbreak Replacement Elbow Connector with Test Point, Repair Elbow has…

UPC: 783786347407


Documents & Media
BrochureInstallation InstructionsSpecification SheetManufacturer Product Website

Contact for Pricing

Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.

Overview

The ABB 274RLR-K-5240 is a 200 Amp, 25kV Loadbreak Replacement Elbow Connector designed for reliable electrical connections in medium voltage applications. This repair elbow features an extended length contact and housing, providing a net gain of 8-7/8 inches in overall length. This extended reach is crucial for facilitating easier and more secure connections in confined or challenging installation spaces. The connector includes a 00400X long Bi-Metal Contact, ensuring robust and durable electrical conductivity. It is engineered to accommodate cable insulation diameters ranging from 1.090 inches to 1.310 inches, offering versatility across various cable sizes. The inclusion of a test point allows for convenient and safe testing of the circuit without disconnecting the primary loadbreak connection, enhancing operational efficiency and safety. This ABB Installation Products component is built for demanding utility and industrial environments where dependable performance is paramount. SKU: 274RLR-K-5240. UNSPSC Code: 39121421.
  • 200 Amp, 25kV Loadbreak Replacement Elbow Connector
  • Extended length contact and housing for increased reach
  • Includes 00400X long Bi-Metal Contact for superior conductivity
  • Accommodates cable insulation diameters from 1.090" to 1.310"

Specifications

Amperage Rating
200 A
Application
25kV, 200 Amps
Color
Black
Conductor Range
1/0 STR/COMPR AWG , 2/0 SOL/COMPT AWG
Environmental Conditions
Fully Submersible
Insulation
True
Material
Housing - EPDM-Rubber
Size
Cable Insulation Diameter 1.090 inch to 1.310 inch
Special Features
Replacement Elbow has extended length contact and elbow housing resulting in a net gain of 8-7/8 inches in length. Includes 00400X long Bi-Metal Contact
Standard
ANSI/IEEE Standard 386
Temperature Rating, Maximum
149 F
Temperature Rating, Maximum
65 C
Temperature Rating, Minimum
-40 F
Temperature Rating, Minimum
-40 C
Type
Loadbreak Replacement Elbow Connector with Test Point
Voltage Rating
25 kV
Package Dimensions (L x W x H)
0.01 IN x 0.01 IN x 0.01 IN
Package Dimensions (L x W x H)
0.0254 cm x 0.0254 cm x 0.0254 cm
Package Weight (Imperial)
0.0500 L
Package Weight (Metric)
0.0230 kg
600 Amp, 15/25kV, 600 Series Deadbreak, Elbow with Insulated Plug, Cap, Stud, Lug and Cable Adapter. Aluminum Compression Lug. Cable Insulation Diameter 0.850 inch to 1.050 inch. Conductor Size AWG Compressed Stranded 1/0 or Compacted Solid 2/0.

K655LR-H0240

600 Amp, 15/25kV, 600 Series Deadbreak, Elbow with Insulated Plug, Cap, Stud, Lug and Cable Adapter. Aluminum Compression Lug. Cable Insulation Diameter 0.850 inch to 1.050 inch. Conductor Size AWG Compressed Stranded 1/0 or Compacted Solid 2/0.
25kV 200 Amp, Loadbreak Replacement Elbow Connector with Test Point. Cable Insulation Diameter 0.760 inch to 0.950 inch. Bi-Metal Compression Lug. Conductor Size AWG Compressed Stranded #3/Solid #2/mmSquared 26.67.

274RLR-G-5210

25kV 200 Amp, Loadbreak Replacement Elbow Connector with Test Point. Cable Insulation Diameter 0.760 inch to 0.950 inch. Bi-Metal Compression Lug. Conductor Size AWG Compressed Stranded #3/Solid #2/mmSquared 26.67.
200 Amp, 15kV, Loadbreak Replacement Elbow Connector without Test Point, Cable Insulation Diameter 0.760 inch to 0.950 inch. Bi-Metal Compression Lug, Conductor Size AWG Compressed Stranded 3/0 /Solid 4/0 /mmSquared 85.01. Repair Elbow has extended length contact and elbow housing resulting in a net gain of 8-7/8 inches in length. Includes 00400X long Bi-Metal Contact.

167RLRG5260

200 Amp, 15kV, Loadbreak Replacement Elbow Connector without Test Point, Cable Insulation Diameter 0.760 inch to 0.950 inch. Bi-Metal Compression Lug, Conductor Size AWG Compressed Stranded 3/0 /Solid 4/0 /mmSquared 85.01. Repair Elbow has extended length contact and elbow housing resulting in a net gain of 8-7/8 inches in length. Includes 00400X long Bi-Metal Contact.
200 Amp, 15kV, Loadbreak Replacement Elbow Connector with Test Point, Cable Insulation Diameter 0.640 inch to 0.820 inch. Bi-Metal Compression Lug, Conductor Size AWG Compressed Stranded #1/Solid 1/0 /mmSquared 42.41. Repair Elbow has extended length contact and elbow housing resulting in a net gain of 8-7/8 inches in length. Includes 00400X long Bi-Metal Contact.

168RLR-F-5230

200 Amp, 15kV, Loadbreak Replacement Elbow Connector with Test Point, Cable Insulation Diameter 0.640 inch to 0.820 inch. Bi-Metal Compression Lug, Conductor Size AWG Compressed Stranded #1/Solid 1/0 /mmSquared 42.41. Repair Elbow has extended length contact and elbow housing resulting in a net gain of 8-7/8 inches in length. Includes 00400X long Bi-Metal Contact.
15kV 200 Amp, Loadbreak Replacement Elbow Connector with Test Point. Cable Insulation Diameter 0.850 inch to 1.050 inch. Bi-Metal Compression Lug. Conductor Size AWG Compressed Stranded #1/Solid 1/0 /mmSquared 42.41.

168RLR-H5230

15kV 200 Amp, Loadbreak Replacement Elbow Connector with Test Point. Cable Insulation Diameter 0.850 inch to 1.050 inch. Bi-Metal Compression Lug. Conductor Size AWG Compressed Stranded #1/Solid 1/0 /mmSquared 42.41.
35kV 200 Amp, Loadbreak Elbow Connector with Test Point, Cable Insulation Diameter 1.090 inch to 1.310 inch. Bi-Metal Compression Lug. Conductor Size AWG Compressed Stranded 3/0 /Solid 4/0 /mmSquared 85.01.

376LR-K-5260

35kV 200 Amp, Loadbreak Elbow Connector with Test Point, Cable Insulation Diameter 1.090 inch to 1.310 inch. Bi-Metal Compression Lug. Conductor Size AWG Compressed Stranded 3/0 /Solid 4/0 /mmSquared 85.01.
200 Amp, 15kV, Loadbreak Replacement Elbow Connector with Test Point, Cable Insulation Diameter 0.640 inch to 0.820 inch. Bi-Metal Compression Lug, Conductor Size AWG Compressed Stranded 2/0 /Solid 3/0 /mmSquared 67.43. Repair Elbow has extended length contact and elbow housing resulting in a net gain of 8-7/8 inches in length. Includes 00400X long Bi-Metal Contact.

168RLR-F-5250

200 Amp, 15kV, Loadbreak Replacement Elbow Connector with Test Point, Cable Insulation Diameter 0.640 inch to 0.820 inch. Bi-Metal Compression Lug, Conductor Size AWG Compressed Stranded 2/0 /Solid 3/0 /mmSquared 67.43. Repair Elbow has extended length contact and elbow housing resulting in a net gain of 8-7/8 inches in length. Includes 00400X long Bi-Metal Contact.
15kV 200 Amp, Loadbreak Replacement Elbow Connector with Test Point. Cable Insulation Diameter 0.640 inch to 0.820 inch. Bi-Metal Compression Lug. Conductor Size AWG Compressed Stranded #4/Solid #3/mmSquared 21.14.

168RLR-F-5200

15kV 200 Amp, Loadbreak Replacement Elbow Connector with Test Point. Cable Insulation Diameter 0.640 inch to 0.820 inch. Bi-Metal Compression Lug. Conductor Size AWG Compressed Stranded #4/Solid #3/mmSquared 21.14.

Frequently Asked Questions

What is the current rating for this loadbreak elbow connector?

The ABB 274RLR-K-5240 loadbreak elbow connector has a current rating of 200 Amps.

What is the maximum voltage rating for this ABB elbow connector?

This ABB loadbreak elbow connector is rated for 25kV (kilovolts).

What cable insulation diameter range does this elbow connector support?

This elbow connector supports cable insulation diameters ranging from 1.090 inches to 1.310 inches.

Does this elbow connector have a test point feature?

Yes, this loadbreak replacement elbow connector includes a test point for convenient circuit testing.

What is the purpose of the extended length on this repair elbow?

The extended length contact and elbow housing provide a net gain of 8-7/8 inches, facilitating easier and more secure connections.

How to Install Elastimold 273RLR/274RLR Loadbreak Replacement Elbow Connectors

This guide provides step-by-step instructions for installing Elastimold 273RLR/274RLR Loadbreak Replacement Elbow Connectors, converting a livefront termination to a deadfront interface for UD cable and connecting to a 25kV class loadbreak bushing.

Estimated time: 2h

Tools needed:

Probe Wrench, Hotstick (live-line tool), Wire brush, Suitable sensing device (for 274RLR voltage test)

Supplies needed:

Elastimold 273RLR or 274RLR Elbow Connector Housing, Compression Lug, Probe, Elastimold supplied Lubricant, Hose Clamp, Copper wire (No. 14 AWG / 2.5mm), Appropriate ground connector

  1. Prepare for Installation and Ensure Safety

    DANGER: All apparatus must be de-energized during installation or removal of parts. Check package contents for completeness and damage. Verify all components fit properly with the cable and mating products. Thread the probe into the compression lug to check for resistance; replace if damaged. Read all instructions and have required tools ready, maintaining cleanliness throughout the procedure.

  2. Remove Livefront Terminator

    Remove the rubber cap from the existing terminator. Cut off the connector at the top of the terminator. Disconnect the ground lead from the base of the terminator. Carefully remove the terminator housing from the cable.

  3. Prepare the Cable

    Train cables to be straight and in-line with the bushing centerline. Cut the cable to measure exactly 10-1/2 inches from the bushing centerline. If the insulation shield measures less than 6-1/2 inches from the end of the cut cable, proceed. Otherwise, consult an Elastimold representative. Remove 1-3/8 inches of cable insulation from the end, cutting squarely and ensuring not to nick the conductor.

  4. Install the Compression Lug

    Wire brush the bare aluminum conductor thoroughly. Immediately install the compression lug, rotating it to spread the inhibitor. Position the compression lug so its contact threaded hole aligns with the bushing bore. Crimp the lug according to the crimp chart, starting at the crimp line mark and rotating 180 degrees for each successive crimp. Carefully wipe any excessive inhibitor from the outside of the lug and cable.

  5. Assemble the Elbow Connector

    Lubricate the cable insulation and the inside of the elbow housing with the supplied lubricant; do not substitute. Slide the elbow connector onto the cable using a back and forth twisting motion, then wipe off all excess grease. Align the elbow with the compression lug's threaded hole. Thread the probe into the lug by hand, ensuring it turns freely for approximately four turns before becoming snug. Tighten the probe with a wrench until the wrench bends.

  6. Connect Concentric Neutral

    Insert one end of a separate copper wire (No. 14 AWG / 2.5mm or equivalent) through the grounding eye on the elbow and twist it tight, taking care not to damage the eye. Twist all neutral wires together and connect them to ground using an appropriate connector. Ensure adequate slack in the wires for elbow operation. Add the supplied hose clamp as shown in the diagram and tighten it snugly, but do not overtighten.

  7. Connect Elbow to Bushing Plug (Loadmake Operation)

    DANGER: Lubricate the receptacle portion of the elbow connector and the mating bushing ONLY if the transformer and elbow are known to be de-energized. Securely fasten a hotstick to the loadbreak connector pulling eye. Place the elbow connector receptacle area over the bushing plug, inserting the elbow male contact into the bushing until the first slight resistance is felt. Immediately push the elbow home with a fast, firm, straight motion to engage the internal lock on the elbow and bushing interface.

  8. Perform Voltage Test (274RLR ONLY)

    This step applies only to the 274RLR model. Remove the test point cap with a hotstick, peeling it off at an angle. WARNING: The voltage test point is a capacitance device, not directly connected to the conductor. Do not use conventional voltage measuring equipment. Use a suitable sensing device designed for capacitive test points to determine if the cable is energized. Treat the elbow as energized until confirmed otherwise. After testing, clean, lubricate the inside surface of the cap with silicone grease, and replace it on the test point.

Frequently Asked Questions about ABB - Installation Products

How are Thomas and Betts products typically installed?

Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.

What accessories are available for Thomas and Betts products?

Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.

What environmental ratings do Thomas and Betts products have?

Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.

What communication protocols do Thomas and Betts products support?

Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.

What are the key features of Thomas and Betts products?

Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.

What are the main product lines offered by Thomas and Betts?

Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.

What technical support does Thomas and Betts offer?

Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.

What industries and applications are Thomas and Betts products used for?

Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.

What certifications and standards do Thomas and Betts products comply with?

Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.

What are the main product lines offered by Ocal?

Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.