Authorized ABB Distributor (Installation Products)
ABB - Installation Products 274RLR-G-5210 - 25kV 200 Amp, Loadbreak Replacement Elbow Connector with Test Point. Cable Insulation Diameter 0.760 inch to 0.950 inch. Bi-Metal Compression Lug. Conductor Size AWG Compressed Stranded #3/Solid #2/mmSquared 26.67.

ABB Installation Products 274RLR-G-5210 25kV 200 Amp, Loadbreak Replacement Elbow Connector with Test Point. Cable Insulation…

UPC: 783786266722


Documents & Media
BrochureInstallation InstructionsSpecification SheetManufacturer Product Website

Contact for Pricing

Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.

Overview

The ABB 274RLR-G-5210 is a 25kV, 200 Amp loadbreak replacement elbow connector designed for safe, reliable connections in medium-voltage cable systems. This connector accommodates cable insulation diameters from 0.760 inch to 0.950 inch, making it suitable for applications where precise fit and electrical integrity are critical. The integrated test point allows for quick and safe voltage verification without disconnecting the system, reducing downtime during maintenance or troubleshooting. The bi-metal compression lug ensures compatibility with compressed stranded conductors sized #3 AWG or solid conductors sized #2 AWG, with a cross-sectional area of 26.67 mm², providing a secure mechanical and electrical connection. Built for medium-voltage distribution networks, this elbow connector is ideal for utility, industrial, and commercial installations where loadbreak functionality and test point accessibility are required. The connector meets industry standards for medium-voltage applications, ensuring compliance with safety and performance requirements. Use this replacement elbow to restore functionality to existing systems or upgrade older installations with a modern, loadbreak-compatible solution.
  • 25kV rated, 200 Amp continuous current capacity
  • Loadbreak replacement elbow with integrated test point for safe voltage verification
  • Accommodates cable insulation diameters from 0.760 inch to 0.950 inch
  • Bi-metal compression lug for #3 AWG compressed stranded or #2 AWG solid conductors (26.67 mm²)
  • Designed for medium-voltage distribution networks in utility, industrial, and commercial applications

Specifications

Amperage Rating
200 A
Application
25kV, 200 Amps
Color
Black
Conductor Range
#3 STR/COMPR AWG , #2 SOL/COMPT AWG
Connection Type
Compression Lug
Current Rating
200 A
Environmental Conditions
Fully Submersible
Insulation
True
Material
Bi-Metal
Material
Housing - EPDM-Rubber
Size
Cable Insulation Diameter 0.760 inch to 0.950 inch
Special Features
Replacement Elbow has extended length contact and elbow housing resulting in a net gain of 8-7/8 inches in length. Includes 00400X long Bi-Metal Contact
Standard
ANSI/IEEE Standard 386
Temperature Rating, Maximum
149 F
Temperature Rating, Maximum
65 C
Temperature Rating, Minimum
-40 F
Temperature Rating, Minimum
-40 C
Type
Loadbreak Replacement Elbow Connector with Test Point
Voltage Rating
25 kV
Voltage Rating
25kV
Package Dimensions (L x W x H)
0.01 IN x 0.01 IN x 0.01 IN
Package Dimensions (L x W x H)
0.0254 cm x 0.0254 cm x 0.0254 cm
Package Weight (Imperial)
4.5100 L
Package Weight (Metric)
2.0460 kg
25kV, Loadbreak Repair Elbow Connector with Test Point, Repair Elbow has extended length contact and elbow housing resulting in a net gain of 3-1/4 inches in length. Includes 02509X long Bi-Metal Contact. Cable Insulation Diameter 0.665 inch to 0.895 inch. Bi-Metal Compression Lug. Conductor Size AWG Compressed Stranded #3/Solid #2/mmSquared 26.67. No Sealing Kit

274ELR-6689-5210

25kV, Loadbreak Repair Elbow Connector with Test Point, Repair Elbow has extended length contact and elbow housing resulting in a net gain of 3-1/4 inches in length. Includes 02509X long Bi-Metal Contact. Cable Insulation Diameter 0.665 inch to 0.895 inch. Bi-Metal Compression Lug. Conductor Size AWG Compressed Stranded #3/Solid #2/mmSquared 26.67. No Sealing Kit
POWER TERMINALS TYPE 3 RENTAL

45030034

POWER TERMINALS TYPE 3 RENTAL
200 Amp, 15kV, Loadbreak Replacement Elbow Connector without Test Point, Cable Insulation Diameter 0.760 inch to 0.950 inch. Bi-Metal Compression Lug, Conductor Size AWG Compressed Stranded 3/0 /Solid 4/0 /mmSquared 85.01. Repair Elbow has extended length contact and elbow housing resulting in a net gain of 8-7/8 inches in length. Includes 00400X long Bi-Metal Contact.

167RLRG5260

200 Amp, 15kV, Loadbreak Replacement Elbow Connector without Test Point, Cable Insulation Diameter 0.760 inch to 0.950 inch. Bi-Metal Compression Lug, Conductor Size AWG Compressed Stranded 3/0 /Solid 4/0 /mmSquared 85.01. Repair Elbow has extended length contact and elbow housing resulting in a net gain of 8-7/8 inches in length. Includes 00400X long Bi-Metal Contact.
200 Amp, 15kV, Loadbreak Replacement Elbow Connector with Test Point, Cable Insulation Diameter 0.640 inch to 0.820 inch. Bi-Metal Compression Lug, Conductor Size AWG Compressed Stranded #1/Solid 1/0 /mmSquared 42.41. Repair Elbow has extended length contact and elbow housing resulting in a net gain of 8-7/8 inches in length. Includes 00400X long Bi-Metal Contact.

168RLR-F-5230

200 Amp, 15kV, Loadbreak Replacement Elbow Connector with Test Point, Cable Insulation Diameter 0.640 inch to 0.820 inch. Bi-Metal Compression Lug, Conductor Size AWG Compressed Stranded #1/Solid 1/0 /mmSquared 42.41. Repair Elbow has extended length contact and elbow housing resulting in a net gain of 8-7/8 inches in length. Includes 00400X long Bi-Metal Contact.
15kV 200 Amp, Loadbreak Replacement Elbow Connector with Test Point. Cable Insulation Diameter 0.850 inch to 1.050 inch. Bi-Metal Compression Lug. Conductor Size AWG Compressed Stranded #1/Solid 1/0 /mmSquared 42.41.

168RLR-H5230

15kV 200 Amp, Loadbreak Replacement Elbow Connector with Test Point. Cable Insulation Diameter 0.850 inch to 1.050 inch. Bi-Metal Compression Lug. Conductor Size AWG Compressed Stranded #1/Solid 1/0 /mmSquared 42.41.
35kV 200 Amp, Loadbreak Elbow Connector with Test Point, Cable Insulation Diameter 1.090 inch to 1.310 inch. Bi-Metal Compression Lug. Conductor Size AWG Compressed Stranded 3/0 /Solid 4/0 /mmSquared 85.01.

376LR-K-5260

35kV 200 Amp, Loadbreak Elbow Connector with Test Point, Cable Insulation Diameter 1.090 inch to 1.310 inch. Bi-Metal Compression Lug. Conductor Size AWG Compressed Stranded 3/0 /Solid 4/0 /mmSquared 85.01.
200 Amp, 15kV, Loadbreak Replacement Elbow Connector with Test Point, Cable Insulation Diameter 0.640 inch to 0.820 inch. Bi-Metal Compression Lug, Conductor Size AWG Compressed Stranded 2/0 /Solid 3/0 /mmSquared 67.43. Repair Elbow has extended length contact and elbow housing resulting in a net gain of 8-7/8 inches in length. Includes 00400X long Bi-Metal Contact.

168RLR-F-5250

200 Amp, 15kV, Loadbreak Replacement Elbow Connector with Test Point, Cable Insulation Diameter 0.640 inch to 0.820 inch. Bi-Metal Compression Lug, Conductor Size AWG Compressed Stranded 2/0 /Solid 3/0 /mmSquared 67.43. Repair Elbow has extended length contact and elbow housing resulting in a net gain of 8-7/8 inches in length. Includes 00400X long Bi-Metal Contact.
15kV 200 Amp, Loadbreak Replacement Elbow Connector with Test Point. Cable Insulation Diameter 0.640 inch to 0.820 inch. Bi-Metal Compression Lug. Conductor Size AWG Compressed Stranded #4/Solid #3/mmSquared 21.14.

168RLR-F-5200

15kV 200 Amp, Loadbreak Replacement Elbow Connector with Test Point. Cable Insulation Diameter 0.640 inch to 0.820 inch. Bi-Metal Compression Lug. Conductor Size AWG Compressed Stranded #4/Solid #3/mmSquared 21.14.

Frequently Asked Questions

Does the 274RLR-G-5210 include a test point?

Yes, the 274RLR-G-5210 is a replacement elbow with a built-in capacitive test point.

How much length does the replacement elbow add?

The replacement elbow provides a net gain of 8 7⁄8 inches in length compared to a standard elbow.

What is the current rating of this elbow?

This elbow connector is rated for 200 A loadbreak applications.

What cable insulation diameter does the 'G' symbol fit?

The 'G' symbol for the 274RLR accommodates cable insulation diameters between 0.760 inches and 0.950 inches.

What type of contact is included with this elbow?

The replacement elbow includes a long bi-metal contact, specifically 00400X.

What is the voltage rating for the 274RLR-G-5210?

The 274RLR-G-5210 is a 25 kV loadbreak replacement elbow connector.

What is the primary use of this elbow connector?

It is a 200 A loadbreak replacement elbow connector designed to transition from live-front to dead-front equipment without splicing or pulling new cable.

What industry standards does this product meet?

The product is IEEE 386 compliant, ANSI certified, and Rural Utilities Service (RUS) accepted.

What cable insulation diameter does the 'G' symbol fit?

The 'G' symbol for the 274RLR accommodates cable insulation diameters between 0.760 inches and 0.950 inches.

What is the primary use of this elbow connector?

It is a 200 A loadbreak replacement elbow connector designed to transition from live-front to dead-front equipment without splicing or pulling new cable.

How to Install the 274RLR Loadbreak Replacement Elbow Connector

A comprehensive guide for the safe installation and initial setup of the 274RLR Loadbreak Replacement Elbow Connector, including cable preparation, component assembly, grounding, and voltage testing.

Estimated time: 1h 30m

Tools needed:

Probe wrench, Wire brush, Crimping tool, Hotstick, Suitable sensing device for capacitive test points

Supplies needed:

274RLR Replacement Elbow Connector Housing, Compression Lug, Probe, Lubricant (supplied with product), Hose Clamp, No. 14 AWG / 2.5mm copper wire, Appropriate ground connector, Silicone grease

  1. Perform Pre-Installation Checks and Safety Procedures

    DANGER: Ensure all apparatus is de-energized during installation or removal of parts. Check the package contents to confirm they are complete and undamaged. Verify all components fit properly with the cable and/or mating products. Test the probe threads by threading it into the compression lug; if resistance is encountered before full assembly, check for damage and replace the component. Gather all required tools and maintain cleanliness throughout the procedure.

  2. Prepare the Cable

    Train the cables to be straight and in-line with the bushing centerline. Cut the cable to measure exactly 10-1/2 inches from the bushing centerline. Carefully remove 1-3/8 inches of cable insulation from the end of the cable, ensuring the cut is square and the conductor is not nicked.

  3. Install the Compression Lug

    Wire brush the bare aluminum conductor immediately after preparation. Install the compression lug onto the conductor, rotating it to evenly spread the inhibitor. Position the compression lug so its contact threaded hole aligns with the bushing bore. Crimp the lug according to the crimp chart provided, starting at the crimp line mark and rotating 180 degrees for each successive crimp. Carefully wipe any excessive inhibitor from the outside of the lug and cable.

  4. Assemble the Elbow Connector

    Lubricate the cable insulation and the inside of the elbow housing using only the lubricant supplied with the product; do not substitute. Slide the elbow connector onto the cable with a back and forth twisting motion, then wipe off all excess grease. Align the elbow with the compression lug’s threaded hole. Thread the probe into the lug by hand, ensuring it turns freely for approximately four turns before becoming snug. Tighten the probe with the probe wrench until the wrench bends.

  5. Connect the Concentric Neutral

    Insert one end of a separate copper wire (No. 14 AWG / 2.5mm or equivalent) through the grounding eye on the elbow and twist it tight, taking care not to damage the eye. Twist all neutral wires together and connect them to ground using an appropriate connector, ensuring adequate slack in the wires for elbow operation. Add the supplied hose clamp as shown in the product diagram and tighten it snugly, but do not overtighten.

  6. Connect the Elbow to the Bushing Plug

    Lubricate the receptacle portion of the elbow connector and the mating bushing with the supplied lubricant. IMPORTANT: Only lubricate if the transformer and elbow are known to be de-energized. Operate the connection using a full insulated 'hotstick' type live-line tool, following the loadmake operating instructions. DO NOT OPERATE BY HAND.

  7. Perform Voltage Test (274RLR Only)

    Remove the test point cap with a hotstick, peeling it off at an angle rather than pulling directly in line. WARNING: The voltage test point is a capacitance device; it is not directly connected to the conductor. Use a suitable sensing device made for capacitive test points to determine if the cable is energized, following the manufacturer’s directions for the meter. Treat the elbow as energized until the 'no voltage' indication is confirmed by other means to prevent serious or fatal injury. After testing, clean and lubricate the inside surface of the cap with silicone grease and replace it on the test point.

Frequently Asked Questions about ABB - Installation Products

How are Thomas and Betts products typically installed?

Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.

What accessories are available for Thomas and Betts products?

Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.

What environmental ratings do Thomas and Betts products have?

Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.

What communication protocols do Thomas and Betts products support?

Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.

What are the key features of Thomas and Betts products?

Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.

What are the main product lines offered by Thomas and Betts?

Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.

What technical support does Thomas and Betts offer?

Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.

What industries and applications are Thomas and Betts products used for?

Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.

What certifications and standards do Thomas and Betts products comply with?

Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.

What are the main product lines offered by Ocal?

Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.