Authorized ABB Distributor (Installation Products)
ABB - Installation Products 376LR-K-5260 - 35kV 200 Amp, Loadbreak Elbow Connector with Test Point, Cable Insulation Diameter 1.090 inch to 1.310 inch. Bi-Metal Compression Lug. Conductor Size AWG Compressed Stranded 3/0 /Solid 4/0 /mmSquared 85.01.

ABB Installation Products 376LR-K-5260 35kV 200 Amp, Loadbreak Elbow Connector with Test Point, Cable Insulation Diameter 1.090…

UPC: 783786352654


Documents & Media
Installation InstructionsSpecification SheetManufacturer Product Website

Contact for Pricing

Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.

Overview

The ABB 376LR-K-5260 Loadbreak Elbow Connector is engineered for reliable 35kV power distribution applications, rated for 200 Amps continuous current. This connector is designed to accommodate a wide range of cable insulation diameters, specifically from 1.090 inches to 1.310 inches, ensuring broad compatibility with common medium-voltage cable sizes. The integrated test point provides a safe and convenient method for voltage verification and system testing without requiring the connector to be de-energized or removed from service, enhancing operational efficiency and safety. Constructed with a robust bi-metal compression lug, this connector offers superior conductivity and mechanical strength, suitable for stranded 3/0 AWG or solid 4/0 AWG conductors (85.01 mm²). The bi-metal construction ensures excellent corrosion resistance and long-term electrical performance, even in challenging environmental conditions. As part of the ABB 376LR-K series, this loadbreak elbow connector meets stringent industry standards for performance and reliability in underground and overhead distribution systems. Its design facilitates quick and secure connections, minimizing installation time and reducing the risk of errors. The 376LR-K-5260 is an essential component for utility, industrial, and commercial power systems requiring dependable loadbreak capabilities and easy diagnostic access. SKU: 376LR-K-5260. Manufacturer: ABB - Installation Products. UNSPSC Code: 39121421.
  • 35kV Voltage Rating
  • 200 Amp Current Rating
  • Accommodates Cable Insulation Diameter: 1.090" to 1.310"
  • Bi-Metal Compression Lug for superior conductivity and durability
  • Integrated Test Point for safe voltage verification

Specifications

Amperage Rating
200 A
Application
35 kv, 200 Amp
Color
Black
Conductor Range
3/0 STR/COMPR AWG , 4/0 SOL/COMPT AWG
Connection
Push-In
Environmental Conditions
Fully Submersible
Insulation
True
Material
Housing - EPDM-Rubber
Size
Cable Insulation Diameter 1.090 inch to 1.310 inch
Special Features
35kV, 200 Amp Loadbreak Elbow. Fully shielded, fully submersible molded rubber housing. 100 percent peroxide-cured construction includes insulation and conductive EPDM materials. Provision for hot stick operation. Provision for ground wire connection. Non-Corrosive Capacitive Voltage Test Point
Standard
ANSI/IEEE Standard 386
Temperature Rating, Maximum
149 F
Temperature Rating, Maximum
65 C
Temperature Rating, Minimum
-40 F
Temperature Rating, Minimum
-40 C
Type
Loadbreak Elbow Connector with Test Point
Voltage Rating
35 kV
Package Dimensions (L x W x H)
0.01 IN x 0.01 IN x 0.01 IN
Package Dimensions (L x W x H)
0.0254 cm x 0.0254 cm x 0.0254 cm
Package Weight (Imperial)
3.1500 L
Package Weight (Metric)
1.4290 kg
200 Amp, 35kV, Loadbreak Elbow Connector with Test Point, Cable Insulation Diameter 0.980 inch to 1.180 inch. Bi-Metal Compression Lug, Conductor Size AWG Compressed Stranded 3/0 /Solid 4/0 /mmSquared 85.01.

376LR-J-5260

200 Amp, 35kV, Loadbreak Elbow Connector with Test Point, Cable Insulation Diameter 0.980 inch to 1.180 inch. Bi-Metal Compression Lug, Conductor Size AWG Compressed Stranded 3/0 /Solid 4/0 /mmSquared 85.01.
200 Amp, 15kV, Loadbreak Replacement Elbow Connector with Test Point, Cable Insulation Diameter 0.640 inch to 0.820 inch. Bi-Metal Compression Lug, Conductor Size AWG Compressed Stranded 2/0 /Solid 3/0 /mmSquared 67.43. Repair Elbow has extended length contact and elbow housing resulting in a net gain of 8-7/8 inches in length. Includes 00400X long Bi-Metal Contact.

168RLR-F-5250

200 Amp, 15kV, Loadbreak Replacement Elbow Connector with Test Point, Cable Insulation Diameter 0.640 inch to 0.820 inch. Bi-Metal Compression Lug, Conductor Size AWG Compressed Stranded 2/0 /Solid 3/0 /mmSquared 67.43. Repair Elbow has extended length contact and elbow housing resulting in a net gain of 8-7/8 inches in length. Includes 00400X long Bi-Metal Contact.
15kV 200 Amp, Loadbreak Replacement Elbow Connector with Test Point. Cable Insulation Diameter 0.640 inch to 0.820 inch. Bi-Metal Compression Lug. Conductor Size AWG Compressed Stranded #4/Solid #3/mmSquared 21.14.

168RLR-F-5200

15kV 200 Amp, Loadbreak Replacement Elbow Connector with Test Point. Cable Insulation Diameter 0.640 inch to 0.820 inch. Bi-Metal Compression Lug. Conductor Size AWG Compressed Stranded #4/Solid #3/mmSquared 21.14.
200 Amp, 15kV, Loadbreak Replacement Elbow Connector with Test Point, Cable Insulation Diameter 0.850 inch to 1.050 inch. Bi-Metal Compression Lug, Conductor Size AWG Compressed Stranded 3/0 /Solid 4/0 /mmSquared 85.01. Repair Elbow has extended length contact and elbow housing resulting in a net gain of 8-7/8 inches in length. Includes 00400X long Bi-Metal Contact.

168RLR-H-5260

200 Amp, 15kV, Loadbreak Replacement Elbow Connector with Test Point, Cable Insulation Diameter 0.850 inch to 1.050 inch. Bi-Metal Compression Lug, Conductor Size AWG Compressed Stranded 3/0 /Solid 4/0 /mmSquared 85.01. Repair Elbow has extended length contact and elbow housing resulting in a net gain of 8-7/8 inches in length. Includes 00400X long Bi-Metal Contact.
25kV 200 Amp, Loadbreak Replacement Elbow Connector with Test Point. Cable Insulation Diameter 0.760 inch to 0.950 inch. Bi-Metal Compression Lug. Conductor Size AWG Compressed Stranded #2/Solid #1/mmSquared 33.62.

274RLR-G-5220

25kV 200 Amp, Loadbreak Replacement Elbow Connector with Test Point. Cable Insulation Diameter 0.760 inch to 0.950 inch. Bi-Metal Compression Lug. Conductor Size AWG Compressed Stranded #2/Solid #1/mmSquared 33.62.
15-25 Kv Elbow Connector, 900 Amps, 600 Series Elbow with insulated plug, cap, stud, lug and cable adapter. Cable Insulation Diameter 1.515 inch to 1.780 inch. Bi-Metal Compression Lug, Conductor Size 750 kcmils Stranded Compressed, With SG3 Sealing Kit - Cold Shrinkable Seal with Copper Braid and Contant Force Spring.

K675LR-N5380-SG3

15-25 Kv Elbow Connector, 900 Amps, 600 Series Elbow with insulated plug, cap, stud, lug and cable adapter. Cable Insulation Diameter 1.515 inch to 1.780 inch. Bi-Metal Compression Lug, Conductor Size 750 kcmils Stranded Compressed, With SG3 Sealing Kit - Cold Shrinkable Seal with Copper Braid and Contant Force Spring.
600 Amp, 35KV, Elbow with Insulated Plug, Cap, Stud, Lug and Cable Adapter, Cable Insulation Diameter 1.515 inch to 1.780 inch. Aluminum Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 900 /Compacted Solid 1000 /mmSquared Compact 500.

755LR-N0400

600 Amp, 35KV, Elbow with Insulated Plug, Cap, Stud, Lug and Cable Adapter, Cable Insulation Diameter 1.515 inch to 1.780 inch. Aluminum Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 900 /Compacted Solid 1000 /mmSquared Compact 500.
200 Amp, 15kV, Loadbreak Replacement Elbow Connector without Test Point, Cable Insulation Diameter 0.760 inch to 0.950 inch. Bi-Metal Compression Lug, Conductor Size AWG Compressed Stranded #2/Solid #1/mmSquared 33.62. Repair Elbow has extended length contact and elbow housing resulting in a net gain of 8-7/8 inches in length. Includes 00400X long Bi-Metal Contact.

167RLR-G-5220

200 Amp, 15kV, Loadbreak Replacement Elbow Connector without Test Point, Cable Insulation Diameter 0.760 inch to 0.950 inch. Bi-Metal Compression Lug, Conductor Size AWG Compressed Stranded #2/Solid #1/mmSquared 33.62. Repair Elbow has extended length contact and elbow housing resulting in a net gain of 8-7/8 inches in length. Includes 00400X long Bi-Metal Contact.

Frequently Asked Questions

What type of lug material is used for conductor connection?

The connector features a bi-metal compression lug for reliable conductor connection.

Does this connector have a test point?

Yes, the ABB 376LR-K-5260 includes an integrated test point for voltage verification.

What conductor sizes are compatible with the compression lug?

The bi-metal compression lug is suitable for compressed stranded 3/0 AWG or solid 4/0 AWG conductors (85.01 mm²).

What is the maximum voltage rating for this elbow connector?

The ABB 376LR-K-5260 loadbreak elbow connector has a maximum voltage rating of 35 kV.

What is the continuous current rating of this connector?

This loadbreak elbow connector is rated for 200 Amps of continuous current.

What cable insulation diameters can this connector accommodate?

The connector is designed for cable insulation diameters ranging from 1.090 inches to 1.310 inches.

How to Install 375LR/376LR Loadbreak Elbow Connectors

This guide provides step-by-step instructions for the safe and proper installation of 375LR (without test point) and 376LR (with test point) Loadbreak Elbow Connectors, including cable preparation, assembly, and connection to a 35kV class bushing.

Estimated time: 1h 30m

Tools needed:

Probe wrench, Crimp tool, Wire brush, Hotstick, Suitable sensing device (for capacitive test points)

Supplies needed:

Elbow connector housing, Compression lug, Probe, Lubricant (Do Not Substitute), Copper wire (No. 14 AWG / 2.5mm or equivalent), Appropriate grounding connector, Silicone grease

  1. Prepare for Installation and Train Cable

    DANGER: All apparatus must be de-energized during installation or removal of parts. Inspect all components for damage, rating, and compatibility. Read all instructions before starting. Train the cable as shown in the documentation to ease operation, ensuring a minimum of 20 inches beyond the end of the cable pad mount transformer. Cut any excess cable squarely at the center line of the bushing.

  2. Prepare the Cable End

    Unwrap and bind the concentric neutral wires 8-1/2 inches back from the end of the cable. Remove the shield and insulation from the cable end, cutting squarely and taking care not to nick the conductor. Wire brush bare aluminum conductors and immediately install the compression lug, rotating it to spread the inhibitor. Position the compression lug so its contact threaded hole aligns with the bushing bore. Crimp the lug according to the crimp chart, starting at the crimp line mark and rotating 180 degrees for each successive crimp. Carefully wipe excessive inhibitor from the outside of the lug and cable. Remove the insulation shield as shown and bevel the insulation end a maximum of 1/8 inch. Thoroughly clean the insulation to remove all traces of conductive residue.

  3. Assemble the Elbow Connector

    Lubricate the cable insulation and the inside of the elbow housing with the supplied lubricant; DO NOT SUBSTITUTE. Slide the elbow connector onto the cable with a back-and-forth twisting motion, then wipe off all excess grease. Align the elbow with the compression lug's threaded hole. Thread the probe into the lug by hand, taking care not to cross-thread. The probe must turn freely for approximately four turns before becoming snug. Tighten the probe with a wrench until the wrench bends.

  4. Connect Concentric Neutral Wires

    Using a separate copper wire (No. 14 AWG / 2.5mm or equivalent), insert one end through the grounding eye on the elbow. Twist it tight, taking care not to damage the eye. Twist all neutral wires together and connect them to ground using an appropriate connector. Provide adequate slack in the wires for elbow operation.

  5. Connect Elbow to Bushing Plug

    CAUTION: Lubricate the receptacle portion of the elbow connector and the mating bushing with the supplied lubricant ONLY IF THE TRANSFORMER AND ELBOW ARE KNOWN TO BE DE-ENERGIZED. Securely fasten a hotstick to the loadbreak connector pulling eye. After establishing firm footing and positive control, insert the probe tip approximately 2 inches into the bushing. Immediately push the elbow home with a fast, firm, straight motion, applying sufficient force to engage the internal lock on the elbow connector and bushing interface. DO NOT HOLD IN THE PARTIALLY INSERTED POSITION.

  6. Perform Voltage Test (376LR Only)

    If using a 376LR connector with a test point, remove the test point cap with a hotstick by peeling it off at an angle rather than pulling directly. WARNING: The voltage test point is a capacitance device and is not directly connected to the conductor. Do not use conventional voltage measuring equipment. Test with a suitable sensing device made for use with separable connectors manufactured with capacitive test points to determine if the cable is energized. Contamination, moisture, dirt, or using the wrong measuring equipment can provide a false 'no voltage' indication. Treat the elbow as energized until the 'no voltage' indication is confirmed by other means to prevent serious or fatal injury. After testing, clean and lubricate the inside surface of the cap with silicone grease and replace it on the test point.

Frequently Asked Questions about ABB - Installation Products

How are Thomas and Betts products typically installed?

Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.

What accessories are available for Thomas and Betts products?

Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.

What environmental ratings do Thomas and Betts products have?

Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.

What communication protocols do Thomas and Betts products support?

Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.

What are the key features of Thomas and Betts products?

Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.

What are the main product lines offered by Thomas and Betts?

Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.

What technical support does Thomas and Betts offer?

Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.

What industries and applications are Thomas and Betts products used for?

Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.

What certifications and standards do Thomas and Betts products comply with?

Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.

What are the main product lines offered by Ocal?

Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.