- 25kV voltage rating
- 200 Amp current rating
- Jacket seal for environmental protection
- Integrated test point for diagnostics
- Bi-metal compression lug for #1 stranded wire
Specifications
Amperage Rating | 200 A |
Application | 200 kV, 200 Amp |
Color | Black |
Conductor Range | #1 STR/COMPR AWG , 1/0 SOL/COMPT AWG |
Environmental Conditions | All Weather Conditions |
Insulation | True |
Length | 11.47 in |
Material | Housing - EPDM-Rubber |
Special Features | 25kV, 200 Amp Loadbreak Elbow. Fully shielded, fully submersible molded rubber housing. 100 percent peroxide-cured construction includes insulation and conductive EPDM materials. Provision for hot stick operation. Provision for ground wire connection. Wide cable range with minimum number of sizes. Long bi-metal compression lug is standard. Built in cable jacket seal. Non-corrosive capacitive test point |
Standard | ANSI/IEEE Standard 386 |
Temperature Rating, Maximum | 149 F |
Temperature Rating, Maximum | 65 C |
Temperature Rating, Minimum | -40 F |
Temperature Rating, Minimum | -40 C |
Type | Loadbreak Elbow Connector with Test Point and Jacket Seal |
Voltage Rating | 28 kV |
Width | 8.2 in |
Package Dimensions (L x W x H) | 0.01 IN x 0.01 IN x 0.01 IN |
Package Dimensions (L x W x H) | 0.0254 cm x 0.0254 cm x 0.0254 cm |
Package Weight (Imperial) | 2.4500 L |
Package Weight (Metric) | 1.1110 kg |

262LR-E5230-SG2
25kV, 200 Amps, Loadbreak Elbow, Cable Insulation Diameter 1.090-1.310 inches, (27.69-33.27 mm), Bi-Metal Conductor, Conductor Size #1 Stranded/Compressed, 1/0 Solid/Compact. With Test Point. 200ECS-G2 Jacket Seal and Grounding Kit Included. Kit Contains Elbow Connector Housing, Compression Lug, Probe, Probe Wrench, Lubricant, Installion Instruction Sheet and Crimp Chart.
262LR-D5250-S
200 Amp, 25kV, Loadbreak Elbow with Test Point, Cable Insulation Diameter 0.890 inch to 1.220 inch. Bi-Metal Compression Lug, Conductor Size AWG Compressed Stranded 2/0 /Solid 3/0 /mmSquared 67.43. 200ECS Jacket Seal Included.
262LR-D5260
25kV 200 Amp, Loadbreak Elbow Connector with Test Point, .890 inch - 1.220 Inch Cable Insulation Diameter, 3/0 Stranded Wire Size, Bi-Metal Compression Lug.
262LR-D5270-S
200 Amp, 25kV, Loadbreak Elbow with Test Point, Cable Insulation Diameter 0.890 inch to 1.220 inch. Bi-Metal Compression Lug, Conductor Size AWG Compressed Stranded 4/0 /Solid 250 /mmSquared 126.67. 200ECS Jacket Seal Included.
262LRJS-D5240
25kV 200 Amp, Loadbreak Jacket Seal Elbow Connector with Test Point, .890 inch - 1.220 Inch Cable Insulation Diameter, 1/0 Stranded - Compressed or 2/0 Compact - Solid Wire Size, Bi-Metal Compression Lug.
262LRJS-D5250
25kV 200 Amp, Loadbreak Jacket Seal Elbow Connector with Test Point, .890 inch - 1.220 Inch Cable Insulation Diameter, 2/0 Stranded Wire Size, Bi-Metal Compression Lug.
262LRJS-D5270
25kV 200 Amp, Loadbreak Jacket Seal Elbow Connector with Test Point, .890 inch - 1.220 Inch Cable Insulation Diameter, 4/0 Stranded Wire Size, Bi-Metal Compression Lug.Frequently Asked Questions
What standards does this product comply with?
The product is IEEE 386 compliant and has ANSI certification. It also has Rural Utilities Service (RUS) acceptance.
Is the Elastimold elbow RUS accepted?
Yes, the enhanced Elastimold 200 amp loadbreak elbow has Rural Utilities Service (RUS) acceptance from the U.S. Department of Agriculture (USDA).
What voltage ranges does this elbow support?
The enhanced Elastimold 200 amp loadbreak elbow supports 15 kV and 25 kV series applications.
What is the current rating of this product?
The product is an enhanced Elastimold 200 amp loadbreak elbow.
What is the current rating of this product?
The product is an enhanced Elastimold 200 amp loadbreak elbow.
What voltage ranges does this elbow support?
The enhanced Elastimold 200 amp loadbreak elbow supports 15 kV and 25 kV series applications.
Is the Elastimold elbow RUS accepted?
Yes, the enhanced Elastimold 200 amp loadbreak elbow has Rural Utilities Service (RUS) acceptance from the U.S. Department of Agriculture (USDA).
What standards does this product comply with?
The product is IEEE 386 compliant and has ANSI certification. It also has Rural Utilities Service (RUS) acceptance.
What is the current rating of this product?
The product is an enhanced Elastimold 200 amp loadbreak elbow.
What voltage ranges does this elbow support?
The enhanced Elastimold 200 amp loadbreak elbow supports 15 kV and 25 kV series applications.
How to Install the 262LRJS Loadbreak Elbow Connector
This guide provides instructions for installing the 262LRJS Loadbreak Elbow Connector, designed to terminate UD cable with jacketed concentric neutral wires and extruded insulation shielding, connecting to 25kV class loadbreak bushings.
Estimated time: 1h 30m
Tools needed:
Probe Wrench, Crimp tool, Wire brush, Hotstick (insulated live-line tool), Suitable sensing device (for capacitive test points)
Supplies needed:
Compression Lug, Probe, Lubricant (supplied, do not substitute), Mastic sealing strips (3), Vinyl tape, Copper wire (No. 14 AWG / 2.5mm), Appropriate ground connector, HV insulated cap(s) or connector(s) (if replacing shipping covers)
- Perform Initial Safety Checks and Component Inspection
Ensure all apparatus is de-energized before beginning installation. This product must be installed only by competent personnel trained in high-voltage safety practices. Inspect all package contents to ensure they are complete and undamaged. Verify all components fit properly with the cable and mating products. Check the probe threads by hand-threading it into the compression lug; if resistance is encountered, replace the damaged component. If supplied with shipping covers, remove them and replace with appropriate HV insulated caps or connectors before energizing or submerging the circuit. Have all required tools ready and maintain cleanliness throughout the procedure.
- Train and Prepare the Cable for Termination
Train the cable to ensure sufficient slack for ease of future operation. Pull extra cable 24-26 inches beyond the bushing centerline and mark it with tape. Remove the outer jacket 7-3/4 to 8 inches back from this tape mark. Unwrap the neutral wires back past the bushing centerline. Cut the excess cable squarely at the bushing centerline.
- Prepare the Cable End and Install the Compression Lug
Wrap one mastic strip, stretching slightly, around the cable jacket. Bend all neutral wires straight back over the mastic and along the cable, pressing them firmly into the mastic. Wrap a second mastic strip completely around the outer jacket, overlapping the imbedded neutral wires. Use a third strip if needed to build up the outer diameter, then cover all mastic with vinyl tape. Remove the insulation shield and insulation from the cable end, cutting squarely without nicking the conductor. Wire brush bare aluminum conductors and immediately install the compression lug, rotating it to spread inhibitor. Position the lug so its threaded hole aligns with the bushing bore. Crimp the lug according to the crimp chart, starting at the crimp line mark and rotating 180 degrees for each successive crimp. Carefully wipe any excessive inhibitor from the lug and cable. Remove the insulation shield as shown in the diagram, and bevel the insulation end by a maximum of 1/8 inch. Thoroughly clean the insulation to remove all traces of conductive residue.
- Assemble the Elbow Connector
Lubricate the cable insulation and the inside of the elbow housing with the supplied lubricant; do not substitute. Slide the elbow connector onto the cable using a back-and-forth twisting motion, then wipe off all excess lubricant. Align the elbow with the compression lug's threaded hole. Thread the probe into the lug by hand, ensuring it turns freely for approximately four turns before becoming snug. Tighten the probe with the supplied wrench until the wrench bends.
- Connect the Concentric Neutral Wires
Insert one end of a separate No. 14 AWG (2.5mm) copper wire or equivalent through the grounding eye on the elbow and twist it tightly, taking care not to damage the eye. Pull the hood over the concentric neutral seal area on the cable by pulling the tabs or rolling the seal down. Twist all neutral wires together and connect them to ground using an appropriate connector, ensuring adequate slack for elbow operation.
- Connect the Elbow to the Bushing
Lubricate the receptacle portion of the elbow connector and the mating bushing with the supplied lubricant ONLY if the transformer and elbow are known to be de-energized. Remove any insulated cap from the bushing using a hotstick tool. Securely fasten the hotstick to the loadbreak connector pulling eye. Confirm positive control of the elbow connector. Insert the probe tip approximately 2 inches (50mm) into the bushing. Immediately push the elbow home with a fast, firm, straight motion, using sufficient force to engage the internal lock on the elbow connector and bushing interface. Do not operate by hand.
Frequently Asked Questions about ABB - Installation Products
How are Thomas and Betts products typically installed?
Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.
What accessories are available for Thomas and Betts products?
Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.
What environmental ratings do Thomas and Betts products have?
Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.
What communication protocols do Thomas and Betts products support?
Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.
What are the key features of Thomas and Betts products?
Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.
What are the main product lines offered by Thomas and Betts?
Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.
What technical support does Thomas and Betts offer?
Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.
What industries and applications are Thomas and Betts products used for?
Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.
What certifications and standards do Thomas and Betts products comply with?
Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.
What are the main product lines offered by Ocal?
Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.