ABB Installation Products 262LR-E5230-SG2 25kV, 200 Amps, Loadbreak Elbow, Cable Insulation Diameter 1.090-1.310 inches…
UPC: 075114312196
Contact for Pricing
Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.
Overview
- 25kV, 200-amp rated loadbreak elbow for underground distribution systems
- Accommodates cable insulation diameters from 1.090 to 1.310 inches (27.69-33.27 mm)
- Supports #1 stranded/compressed or 1/0 solid/compact copper conductors
- Bi-metal conductor for reliable electrical continuity and mechanical strength
- Includes test point for safe voltage verification without system de-energization
Specifications
Amperage Rating | 200 A |
Application | Designed for connecting to and operating 28kV class, 200 Amp Distribution Apparatus |
Color | Black |
Conductor Range | #1 STR/COMPR AWG , 1/0 SOL/COMPT AWG |
Connection Type | Loadbreak Elbow |
Current Rating | 200 A |
Environmental Conditions | Fully Submersible |
Insulation | True |
Material | Bi-Metal Conductor, Copper |
Material | Housing - EPDM-Rubber |
Series | 262LR |
Size | Cable Insulation Diameter 1.090-1.310 inches, |
Size | Cable Insulation Diameter 1.090-1.310 inches (27.69-33.27 mm), Conductor Size #1 Stranded/Compressed, 1/0 Solid/Compact |
Special Features | Fully Shielded, Fully Submersible Molded Rubber Housing. 100 percent Peroxide-Cured construction includes insulation and conductive EPDM materials. Provision for hot stick operation, Provision for ground wire connection. Wide cable range with minimum number of sizes. Long bi-metal compression lug is standard |
Standard | ANSI/IEEE Standard 386 |
Temperature Rating, Maximum | 149 F |
Temperature Rating, Maximum | 65 C |
Temperature Rating, Minimum | -40 F |
Temperature Rating, Minimum | -40 C |
Type | Loadbreak Elbow Connector with Test Point |
Voltage Rating | 28 kV |
Voltage Rating | 25 kV |
Package Dimensions (L x W x H) | 0.01 IN x 0.01 IN x 0.01 IN |
Package Dimensions (L x W x H) | 0.0254 cm x 0.0254 cm x 0.0254 cm |
Package Weight (Imperial) | 1.0000 L |
Package Weight (Metric) | 0.4540 kg |

262LR-D5230-SG3
15/25kV, 200 Amp, Deadbreak Elbow Connector with Test Point, Cable Insulation Diameter 0.890-1.220 inches (22.61-30.99mm), Bi-Metal Lug, Conductor Size 230 - #1 Stranded/Compressed or 1/0 Solid/Compact. Kit Includes Elbow Connector Housing, Lug, Probe, Probe Wrench, Bail Assembly, V.D. Cap-Peroxide, Tube of Lubricant, Crimp Chart and Installations Instructions. 5.454 x 9.03 inches tall, 2.097 inch diameter. Includes SG3 - Cold-Shrinkable Seal with Copper Braid and Constant Force Spring.
274ELR-7495-5230
200 Amp, 25kV, Loadbreak Repair Elbow Connector with Test Point, Repair Elbow has extended length contact and elbow housing resulting in a net gain of 3-1/4 inches in length. Includes 02509X long Bi-Metal Contact. No Sealing Kit, Cable Insulation Diameter 0.740 inch to 0.950 inch. Bi-Metal Compression Lug. Conductor Size AWG Compressed Stranded 1/0 /Solid 2/0 /mmSquared 53.49.
274ELR-88110-5230
200 Amp, 25kV, Loadbreak Repair Elbow Connector with Test Point, Repair Elbow has extended length contact and elbow housing resulting in a net gain of 3-1/4 inches in length. Includes 02509X long Bi-Metal Contact., No Sealing Kit, Cable Insulation Diameter 0.880 inch to 1.100 inch. Bi-Metal Compression Lug. Conductor Size AWG Compressed Stranded #1/Solid 1/0 /mmSquared 42.41.
262LR-E5250-SG2
25kV, 200 Amps, Loadbreak Elbow, Cable Insulation Diameter 1.090-1.310 inches, (27.69-33.27 mm), Bi-Metal Conductor, Conductor Size 20/ Stranded/Compressed, 3/0 Solid/Compact. With Test Point. 200ECS-G2 Jacket Seal and Grounding Kit Included. Kit Contains Elbow Connector Housing, Compression Lug, Probe, Probe Wrench, Lubricant, Installation Instruction Sheet and Crimp Chart.
262LR-E5260
25kV, 200 Amps, Loadbreak Elbow, no Sealing Kit, Cable Insulation Diameter 1.090-1.310 inches, (27.69-33.27 mm), Bi-Metal Conductor, Conductor Size 3/0 Stranded/Compressed, 4/0 Solid/Compact. With Test Point. Kit Contains Elbow Connector Housing, Compression Lug, Probe, Probe Wrench, Lubricant, Installion Instruction Sheet and Crimp Chart.
262LRJS-E5240
25kV, 200 Amps, Loadbreak Elbow, Built in Jacket Seal, Cable Insulation Diameter 1.090-1.310 inches, (27.69-33.27 mm), Bi-Metal Conductor, Conductor Size 1/0 Stranded/Compressed, 2/0 Solid/Compact. With Test Point. Kit Contains Elbow Connector Housing, Compression Lug, Probe, Probe Wrench, Lubricant, Installion Instruction Sheet and Crimp Chart.
262LR-E5270
25kV, 200 Amps, Loadbreak Elbow, no Sealing Kit, Cable Insulation Diameter 1.090-1.310 inches, (27.69-33.27 mm), Bi-Metal Conductor, Conductor Size 4/0 Stranded/Compressed, 250 Solid/Compact. With Test Point. Kit Contains Elbow Connector Housing, Compression Lug, Probe, Probe Wrench, Lubricant, Installion Instruction Sheet and Crimp Chart.
167LRT-F5220-SG3
15kV, 200 Amps, Loadbreak, Elbow-T, with Sealing Kit, Cable Insulation Diameter .640- .820 inches, Bi-Metal Lug, Conductor Size #2 Stranded/Compressed or #1 Solid/Compact.Frequently Asked Questions
What is the maximum operating voltage?
The device is rated for 25kV maximum operating voltage.
What cable insulation diameters does it support?
It supports cable insulation diameters from 1.090 to 1.310 inches (27.69-33.27 mm).
What conductor sizes are compatible?
Compatible with #1 stranded/compressed or 1/0 solid/compact copper conductors.
Does it include a test point?
Yes, it includes an integrated test point for voltage verification.
What is included in the grounding kit?
The kit contains an elbow connector housing, compression lug, probe, probe wrench, lubricant, installation instructions, and crimp chart.
What is the current rating of this elbow?
The elbow is rated for 200 amps continuous current.
Is this product suitable for underground distribution?
Yes, it is designed for underground distribution systems in medium-voltage networks.
How to Install 262LR Loadbreak Elbow Connectors
This guide provides step-by-step instructions for the safe installation and initial setup of the 262LR Loadbreak Elbow Connector, designed for terminating UD cables and connecting to 25kV class loadbreak bushings.
Estimated time: 1h 30m
Tools needed:
Probe Wrench, Crimp tool, Wire brush, Wrench, Hotstick
Supplies needed:
Lubricant (Do Not Substitute), No. 14 AWG / 2.5mm copper wire, Appropriate connector (for neutral wires)
- Perform Safety Checks and Component Inspection
DANGER: All apparatus must be de-energized during installation or removal of parts. This product should be installed only by competent personnel trained in good safety practices involving high voltage electrical equipment. Inspect all package contents and components for damage, proper fit with cable and mating products. Check threads by threading the probe into the compression lug; replace damaged components if resistance is encountered.
- Prepare the Cable
Train the cable to ensure adequate slack for operation. Cut the excess cable squarely at the centerline of the bushing. Remove the outer jacket and insulation shield according to the specific cable type (e.g., non-jacketed, jacketed concentric neutral, jacketed with drain wires, or jacketed copper tape shield) and the specified dimensions (e.g., 9-5/8" (240mm) for jacket, 6-7/8" (175mm) for insulation shield). Bevel the insulation end 1/8" (5mm) maximum.
- Prepare Conductor and Install Compression Lug
Remove 2-1/8" (55mm) of shield and insulation from the cable end, cutting squarely without nicking the conductor. Wire brush the bare aluminum conductors thoroughly. Immediately install the compression lug, rotating it to spread the inhibitor and ensuring the contact threaded hole aligns with the bushing bore. Crimp the lug according to the crimp chart, starting at the crimp line mark and rotating 180 degrees for each successive crimp. Carefully wipe off any excess inhibitor from the lug and cable. Thoroughly clean the insulation.
- Assemble the Elbow Housing
Lubricate the cable insulation and the inside of the elbow housing with the supplied lubricant; DO NOT SUBSTITUTE. Slide the elbow connector onto the cable using a back-and-forth twisting motion. Wipe off all excess lubricant. Align the elbow with the compression lug's threaded hole. Thread the probe into the lug by hand, ensuring it turns freely for approximately four turns before becoming snug. Tighten the probe with a wrench until the wrench bends.
- Ground the Elbow
Insert one end of a separate No. 14 AWG / 2.5mm copper wire (or equivalent) through the grounding eye on the elbow and twist it tightly, taking care not to damage the eye. Twist all neutral wires together and connect them to ground using an appropriate connector, providing adequate slack in the wires for elbow operation.
- Connect Elbow to Bushing
DANGER: CONFIRM THAT BOTH THE TRANSFORMER AND THE ELBOW ARE DE-ENERGIZED before proceeding. Lubricate the receptacle portion of the elbow connector and the mating bushing with the supplied lubricant. Operate the connection using a full insulated hotstick type tool; DO NOT OPERATE BY HAND.
Frequently Asked Questions about ABB - Installation Products
How are Thomas and Betts products typically installed?
Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.
What accessories are available for Thomas and Betts products?
Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.
What environmental ratings do Thomas and Betts products have?
Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.
What communication protocols do Thomas and Betts products support?
Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.
What are the key features of Thomas and Betts products?
Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.
What are the main product lines offered by Thomas and Betts?
Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.
What technical support does Thomas and Betts offer?
Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.
What industries and applications are Thomas and Betts products used for?
Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.
What certifications and standards do Thomas and Betts products comply with?
Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.
What are the main product lines offered by Ocal?
Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.