Authorized ABB Distributor (Installation Products)
ABB - Installation Products 262LR-D5270-S - 200 Amp, 25kV, Loadbreak Elbow with Test Point, Cable Insulation Diameter 0.890 inch to 1.220 inch. Bi-Metal Compression Lug, Conductor Size AWG Compressed Stranded 4/0 /Solid 250 /mmSquared 126.67. 200ECS Jacket Seal Included.
More images

ABB Installation Products 262LR-D5270-S 200 Amp, 25kV, Loadbreak Elbow with Test Point, Cable Insulation Diameter 0.890 inch to…

UPC: 075114192637


Documents & Media
BrochureInstallation InstructionsSpecification SheetManufacturer Product Website

Contact for Pricing

Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.

Overview

The ABB 262LR-D5270-S is a 200 Amp, 25kV loadbreak elbow connector engineered for reliable medium-voltage cable terminations in industrial and utility applications. This loadbreak elbow features an integrated test point, enabling safe voltage testing without de-energizing the circuit, reducing downtime and enhancing operational safety. Designed to accommodate cable insulation diameters from 0.890 inches to 1.220 inches, the 262LR-D5270-S ensures compatibility with a wide range of medium-voltage cables, including those with compressed stranded conductors up to 4/0 AWG and solid conductors up to 250 mm² (126.67 mm²). The connector incorporates a bi-metal compression lug for secure, corrosion-resistant connections that maintain electrical integrity over time. The included 200ECS jacket seal provides environmental protection, preventing moisture ingress and contamination in harsh operating conditions. This loadbreak elbow is ideal for applications requiring robust, maintenance-free terminations in medium-voltage power distribution systems, including switchgear, transformers, and cable assemblies. Key specifications include a 200 Amp continuous current rating, 25kV maximum voltage rating, and compatibility with copper conductors. The bi-metal lug ensures compatibility with both copper and aluminum conductors, offering versatility for diverse installation requirements. The integrated test point allows for quick and safe voltage verification, streamlining maintenance and troubleshooting processes. The 262LR-D5270-S is part of ABB’s Installation Products line, known for precision-engineered components that meet the demands of modern electrical infrastructure. Its compact design and durable construction make it suitable for both indoor and outdoor installations where reliability and safety are critical.
  • 200 Amp continuous current rating, 25kV maximum voltage rating
  • Integrated test point for safe voltage testing without de-energizing circuits
  • Bi-metal compression lug for secure, corrosion-resistant connections
  • Compatible with cable insulation diameters from 0.890 to 1.220 inches
  • Includes 200ECS jacket seal for environmental protection

Specifications

Amperage Rating
200 A
Application
200 kV, 200 Amp
Cable Insulation Diameter Range
0.890" - 1.220"
Color
Black
Conductor Range
4/0 STR/COMPR AWG , 250 kcmil
Conductor Size
4/0 AWG Compressed Stranded / Solid 250 /mm² 126.67
Connection Type
LoadBreak Elbow Connector
Connection Type
Loadbreak Elbow
Current Rating
200A
Current Rating
200 A
Environmental Conditions
All Weather Conditions
Insulation
True
Jacket Seal
200ECS
Material
Housing - EPDM-Rubber
Material
Bi-Metal Compression Lug, 200ECS Jacket Seal
Material
Bi-Metal Compression Lug
Series
262LR
Size
Cable Insulation Diameter 0.890 inch to 1.220 inch
Size
0.890-1.220 inch cable insulation diameter, 4/0 AWG compressed stranded / Solid 250 mm²
Size
9.03 inch (299.4 mm) X 8.20 inch (208.3 mm) not including probe, 2.86 inch (72.6 mm) Diameter
Special Features
28kV, 200 Amp Loadbreak Elbow. Fully shielded, fully submersible molded rubber housing. 100 percent peroxide-cured construction includes insulation and conductive EPDM materials. Provision for hot stick operation. Provision for ground wire connection. Wide cable range with minimum number of sizes. Long bi-metal compression lug is standard. Non-corrosive capacitive test point
Standard
ANSI/IEEE Standard 386
Temperature Rating, Maximum
149 F
Temperature Rating, Maximum
65 C
Temperature Rating, Minimum
-40 F
Temperature Rating, Minimum
-40 C
Termination Type
Bi-Metal Compression Lug
Test Point
Yes
Type
Loadbreak Elbow Connector with Test Point
Voltage Rating
28 kV
Voltage Rating
25kV
Voltage Rating
25 kV
Package Dimensions (L x W x H)
0.01 IN x 0.01 IN x 0.01 IN
Package Dimensions (L x W x H)
0.0254 cm x 0.0254 cm x 0.0254 cm
Package Weight (Imperial)
1.0000 L
Package Weight (Metric)
0.4540 kg
200 Amp, 15kV, Loadbreak Elbow Connector, Cable Insulation Diameter 0.890 inch to 1.220 inch. Bi-Metal Compression Lug. Conductor Size AWG Compressed Stranded 4/0 /Solid 250 /mmSquared 126.67. 200ECS Jacket Seal Included.

162LR-D5270-S

200 Amp, 15kV, Loadbreak Elbow Connector, Cable Insulation Diameter 0.890 inch to 1.220 inch. Bi-Metal Compression Lug. Conductor Size AWG Compressed Stranded 4/0 /Solid 250 /mmSquared 126.67. 200ECS Jacket Seal Included.
25kV 200 Amp, Loadbreak Jacket Seal Elbow Connector with Test Point, .890 inch - 1.220 Inch Cable Insulation Diameter, 1/0 Stranded - Compressed or 2/0 Compact - Solid Wire Size, Bi-Metal Compression Lug.

262LRJS-D5240

25kV 200 Amp, Loadbreak Jacket Seal Elbow Connector with Test Point, .890 inch - 1.220 Inch Cable Insulation Diameter, 1/0 Stranded - Compressed or 2/0 Compact - Solid Wire Size, Bi-Metal Compression Lug.
25kV 200 Amp, Loadbreak Jacket Seal Elbow Connector with Test Point, .890 inch - 1.220 Inch Cable Insulation Diameter, 2/0 Stranded Wire Size, Bi-Metal Compression Lug.

262LRJS-D5250

25kV 200 Amp, Loadbreak Jacket Seal Elbow Connector with Test Point, .890 inch - 1.220 Inch Cable Insulation Diameter, 2/0 Stranded Wire Size, Bi-Metal Compression Lug.
25kV 200 Amp, Loadbreak Jacket Seal Elbow Connector with Test Point, .890 inch - 1.220 Inch Cable Insulation Diameter, 4/0 Stranded Wire Size, Bi-Metal Compression Lug.

262LRJS-D5270

25kV 200 Amp, Loadbreak Jacket Seal Elbow Connector with Test Point, .890 inch - 1.220 Inch Cable Insulation Diameter, 4/0 Stranded Wire Size, Bi-Metal Compression Lug.
25kV 200 Amp, Loadbreak Jacket Seal Elbow Connector with Test Point, .890 inch - 1.220 Inch Cable Insulation Diameter, 3/0 Stranded Wire Size, Bi-Metal Compression Lug.

262LRJS-D5260

25kV 200 Amp, Loadbreak Jacket Seal Elbow Connector with Test Point, .890 inch - 1.220 Inch Cable Insulation Diameter, 3/0 Stranded Wire Size, Bi-Metal Compression Lug.
25kV 200 Amp, Loadbreak Jacket Seal Elbow Connector with Test Point, .635 inch - .905 Inch Cable Insulation Diameter, 2/0 Stranded/Compressed or 3/0 Compact/Solid Wire Size, Bi-Metal Compression Lug.

262LRJS-B5250

25kV 200 Amp, Loadbreak Jacket Seal Elbow Connector with Test Point, .635 inch - .905 Inch Cable Insulation Diameter, 2/0 Stranded/Compressed or 3/0 Compact/Solid Wire Size, Bi-Metal Compression Lug.
15/25kV, 200 Amp, Deadbreak Elbow Connector with Test Point, Cable Insulation Diameter 0.890-1.220 inches (22.61-30.99mm), Bi-Metal Lug, Conductor Size 230 - #1 Stranded/Compressed or 1/0 Solid/Compact. Kit Includes Elbow Connector Housing, Lug, Probe, Probe Wrench, Bail Assembly, V.D. Cap-Peroxide, Tube of Lubricant, Crimp Chart and Installations Instructions. 5.454 x 9.03 inches tall, 2.097 inch diameter. Includes Cold Shrink-Fit Jacket Seal Kit

262LR-D5230-S

15/25kV, 200 Amp, Deadbreak Elbow Connector with Test Point, Cable Insulation Diameter 0.890-1.220 inches (22.61-30.99mm), Bi-Metal Lug, Conductor Size 230 - #1 Stranded/Compressed or 1/0 Solid/Compact. Kit Includes Elbow Connector Housing, Lug, Probe, Probe Wrench, Bail Assembly, V.D. Cap-Peroxide, Tube of Lubricant, Crimp Chart and Installations Instructions. 5.454 x 9.03 inches tall, 2.097 inch diameter. Includes Cold Shrink-Fit Jacket Seal Kit
200 Amp, 25kV, Loadbreak Elbow with Test Point, Cable Insulation Diameter 0.805 inch to 1.060 inch. Bi-Metal Compression Lug, Conductor Size AWG Compressed Stranded 3/0 /Solid 4/0 /mmSquared 85.01

262LR-C5260

200 Amp, 25kV, Loadbreak Elbow with Test Point, Cable Insulation Diameter 0.805 inch to 1.060 inch. Bi-Metal Compression Lug, Conductor Size AWG Compressed Stranded 3/0 /Solid 4/0 /mmSquared 85.01

Frequently Asked Questions

What is the purpose of the rigid probe support?

The internal rigid probe support ensures proper switching and easy probe installation.

Is an optional integral jacket seal available?

Yes, the enhanced design includes an optional integral jacket seal for increased flexibility.

What material is the pulling eye made from?

The pulling eye is made from robust stainless steel, promoting durable hotstick control.

Does the elbow have a no-stick interface?

Yes, it features a no-stick interface when used with Elastimold bushings, which has been NEETRAC tested.

What standards and certifications does it meet?

The product is IEEE 386 compliant and has ANSI certification, along with Rural Utilities Service (RUS) acceptance.

Is the Elastimold elbow RUS accepted?

Yes, the enhanced Elastimold 200 amp loadbreak elbow has Rural Utilities Service (RUS) acceptance from the U.S. Department of Agriculture (USDA).

What are the voltage ratings for this elbow?

The enhanced Elastimold 200 amp loadbreak elbow is available for 15 kV and 25 kV series.

What is the Elastimold 200 amp loadbreak elbow?

It's an enhanced loadbreak elbow for 15 kV and 25 kV systems, designed for easier switching and improved safety.

Is an optional integral jacket seal available?

Yes, the enhanced design includes an optional integral jacket seal for increased flexibility.

What are the voltage ratings for this elbow?

The enhanced Elastimold 200 amp loadbreak elbow is available for 15 kV and 25 kV series.

How to Install the 262LR Loadbreak Elbow Connector

This guide provides step-by-step instructions for the safe and proper installation of the 262LR Loadbreak Elbow Connector, including cable preparation, assembly, and grounding. It is designed for competent personnel trained in high voltage electrical equipment.

Estimated time: 1h 30m

Tools needed:

Wire brush, Crimp tool, Probe wrench, Hotstick, Voltage sensing device (for capacitive test points)

Supplies needed:

Elbow Connector Housing, Compression Lug, Probe, Lubricant (Do Not Substitute), Copper wire (No. 14 AWG / 2.5mm or equivalent), Appropriate connector (for neutral wires), Optional sealing kit components (e.g., cold shrink tube, conductive copper tape), Electrical tape

  1. Review Safety and Inspect Components

    DANGER: Ensure all apparatus is de-energized during installation or removal of parts, except for test point caps and indicators. This product must be installed only by competent personnel trained in high voltage safety practices. Inspect all package contents and components for completeness, damage, proper fit with cable, and compatibility with mating products. Check probe threads by hand-threading into the compression lug to ensure free movement without resistance.

  2. Prepare the Cable for Termination

    Train the cable to ensure adequate slack for operation. Based on your cable type (non-jacketed/jacketed concentric neutral, jacketed with drain wires, or jacketed copper tape shield), follow specific instructions to prepare neutral/ground wires and remove the outer jacket. For example, remove 9-5/8" (240mm) of the outer jacket and 7-1/8" (180mm) of copper tape shield for jacketed copper tape shield cable. Cut the cable squarely at the bushing centerline. If using a sealing kit, slide the cold shrink tube onto the cable loose end first.

  3. Prepare Conductor and Insulation

    Remove the shield and insulation 2-1/8" (55mm) from the cable end, ensuring a square cut without nicking the conductor. Wire brush bare aluminum conductors thoroughly and immediately install the compression lug, rotating to spread inhibitor. Position the lug so its threaded hole aligns with the bushing bore. Crimp the lug according to the crimp chart, starting at the crimp line mark and rotating 180 degrees for each successive crimp. Carefully wipe off excess inhibitor. Remove the insulation shield 6-7/8" (175mm) back from the lug, beveling the insulation end 1/8" (5mm) maximum. Thoroughly clean the insulation.

  4. Assemble the Elbow Connector

    Lubricate the cable insulation and the inside of the elbow housing with the supplied lubricant. DO NOT SUBSTITUTE. Slide the elbow connector onto the cable using a back-and-forth twisting motion, then wipe off all excess lubricant. Align the elbow with the compression lug's threaded hole. Thread the probe into the lug by hand, ensuring it turns freely for approximately four turns before becoming snug. Tighten the probe with the supplied wrench until the wrench bends.

  5. Establish Grounding Connections

    Insert one end of a separate copper wire (No. 14 AWG / 2.5mm or equivalent) through the grounding eye on the elbow and twist tightly, taking care not to damage the eye. Twist all neutral wires together and connect them to ground using an appropriate connector. Ensure adequate slack in the wires for elbow operation. If using a cold shrink grounding kit, refer to its specific instructions.

  6. Connect Elbow to De-energized Bushing

    CONFIRM THAT BOTH THE TRANSFORMER AND ELBOW ARE DE-ENERGIZED before proceeding. Lubricate the receptacle portion of the elbow connector and the mating bushing with the supplied lubricant. Securely fasten a full insulated hotstick to the loadbreak connector pulling eye. Carefully insert the elbow connector onto the bushing with a fast, firm, straight motion, ensuring sufficient force to engage the internal lock. DO NOT OPERATE BY HAND.

  7. Perform Voltage Test (Optional Initial Setup)

    If your 262LR connector has an integral capacitance test point, you can use it to determine if the circuit is energized. Remove the test point cap with a hotstick, peeling it off at an angle. WARNING: The voltage test point is a capacitance device; do not use conventional voltage measuring equipment. Use a suitable sensing device designed for capacitive test points and follow its manufacturer's directions. Treat the elbow as energized until the 'no voltage' indication is confirmed by other means. After testing, clean the inside surface of the cap, lubricate with silicone lubricant, and replace it.

Frequently Asked Questions about ABB - Installation Products

How are Thomas and Betts products typically installed?

Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.

What accessories are available for Thomas and Betts products?

Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.

What environmental ratings do Thomas and Betts products have?

Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.

What communication protocols do Thomas and Betts products support?

Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.

What are the key features of Thomas and Betts products?

Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.

What are the main product lines offered by Thomas and Betts?

Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.

What technical support does Thomas and Betts offer?

Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.

What industries and applications are Thomas and Betts products used for?

Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.

What certifications and standards do Thomas and Betts products comply with?

Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.

What are the main product lines offered by Ocal?

Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.