ABB Installation Products 252LR-B5230 15/25kV, 200 Amp, Deadbreak Elbow Connector with Test Point, Cable Insulation Diameter…
UPC: 075114345811
Contact for Pricing
Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.
Overview
- 15/25kV voltage class with 200 Amp continuous rating
- Integrated test point for safe circuit verification without de-energization
- Accommodates cable insulation diameters from 0.635 to 0.905 inches (16.13-22.99mm)
- Bi-metal lug supports 230 MCM to #1 stranded/compressed and 1/0 solid/compact conductors
- Fully shielded, dead-front molded rubber housing for submersible applications
- Compact 5.454 x 7.531 inch housing with 2.097 inch diameter for confined spaces
- Kit includes probe, wrench, bail assembly, lubricant, crimp chart, and installation instructions
Specifications
Amperage Rating | 200 A |
Application | 15/25kV, 200 Amp Deadbreak Connector |
Color | Black |
Conductor Range | #1 STR/COMPR AWG , 1/0 SOL/COMPT AWG |
Connection | Compression |
Connection Type | Deadbreak Elbow Connector |
Current Rating | 200 A |
Environmental Conditions | Fully Submersible |
Insulation | True |
Length | 7.531 in |
Length | 191.2874 mm |
Material | Housing - EPDM-Rubber |
Material | Bi-Metal Lug, Polyethylene (assumed from description) |
Series | 252LR |
Size | 5.454 x 7.531 inches, 2.097 inch diameter |
Special Features | Fully Shielded, fully Submersible Molded Rubber Housing. Provision for Hot Stick Operation. Non-Corrosive, Capacitive Test Point |
Standard | ANSI/IEEE Standard 386 |
Temperature Rating, Maximum | 149 F |
Temperature Rating, Maximum | 65 C |
Temperature Rating, Minimum | -40 F |
Temperature Rating, Minimum | -40 C |
Type | Deadbreak Elbow Connector with Test Point |
Voltage Rating | 15 to 25 kV |
Voltage Rating | 15/25 kV |
Width | 5.454 in |
Width | 138.5316 mm |
Package Dimensions (L x W x H) | 0.01 IN x 0.01 IN x 0.01 IN |
Package Dimensions (L x W x H) | 0.0254 cm x 0.0254 cm x 0.0254 cm |
Package Weight (Imperial) | 1.0000 L |
Package Weight (Metric) | 0.4540 kg |

K656YSR-H0230
600 Amp, 15/25kV, Deadbreak, Straight Receptacle with Test Point, Cable Insulation Diameter .850 inch to 1.050 inch. Aluminum Compression Lug. Conductor Size AWG Compressed Stranded #1 or Compacted Solid 1/0.
252LR-B5270
15/25kV, 200 Amp, Deadbreak Elbow Connector with Test Point, Cable Insulation Diameter 0.635-0.905 inches (16.13-22.99mm), Bi-Metal Lug, Conductor Size 270 - 4/0 Stranded/Compressed, 250kcmil Solid/Compact. Kit Includes Elbow Connector Housing, Lug, Probe, Probe Wrench, Bail Assembly, V.D. Cap-Peroxide, Tube of Lubricant, Crimp Chart and Installations Instructions. 5.454 x 7.531 inches, 2.097 inch diameter.
252LR-C5250
15/25kV, 200 Amp, Deadbreak Elbow Connector with Test Point, Cable Insulation Diameter 0.805-1.060 inches (20.45-26.92mm), Bi-Metal Lug, Conductor Size 250 - 2/0 Stranded/Compressed, 3/0 Solid/Compact. Kit Includes Elbow Connector Housing, Lug, Probe, Probe Wrench, Bail Assembly, V.D. Cap-Peroxide, Tube of Lubricant, Crimp Chart and Installations Instructions. 5.454 x 7.531 inches, 2.097 inch diameter.
K675LR-K2330
15/25kV, 900 Amps, Deadbreak Elbow without Test Point. Cable Insulation Diameter K - 1.090-1.310 inch (27.689-33.274mm). Copper Compression Lug. Conductor Size 330 - Stranded/Compressed 500 kcmil, Solid/Compact 600 kcmil, mmsq 250/300.
162LR-B5250-SG2
200 Amp, 15kV, Loadbreak Elbow Connector with Test Point, Cable Insulation Diameter 0.635 inch to 0.905 inch. Bi-Metal Compression Lug. Conductor Size AWG Compressed Stranded 2/0 /Solid 3/0 /mmSquared 67.43.
162LR-D2270
15kV, 200 Amps, Loadbreak Elbow Connector with Test Point. Cable Insulation Diameter .890-1.220 inches (22.61-30.99mm). Copper Compression Lug. Conductor Size 270 - 4/0 Stranded/Compressed or 250 kcmil Solid/Compact or 107.20 mmsq. No Sealing Kit. Includes Elbow Housing, Compression Lug, Probe, Probe Wrench, Tube of Lubricant, Crimp Chart, V.D. Cap - Peroxide, and Installation Instructions.
262LRJS-E5270
25kV, 200 Amps, Loadbreak Elbow, Built in Jacket Seal, Cable Insulation Diameter 1.090-1.310 inches, (27.69-33.27 mm), Bi-Metal Conductor, Conductor Size 4/0 Stranded/Compressed, 250 Solid/Compact. With Test Point. Kit Contains Elbow Connector Housing, Compression Lug, Probe, Probe Wrench, Lubricant, Installion Instruction Sheet and Crimp Chart.
262LRJS-A5210
25kV, 200 Amp Loadbreak Elbow with Test Point and Jacket Seal. Cable Insulation Diameter 0.575 - 0.740 inches (14.6-18.8mm). Bi-Metal Compression Lug. Conductor Size 210 - #3 Stranded/Compressed or #2 Solid/Compact. Kit Includes Elbow Connector Housing, Lug, Probe, Probe Wrench, Tube of Lubricant, Crimp Chart, V.D. Cap Peroxide and Installation Instructions.Frequently Asked Questions
Which industry standard does the 252LR connector meet?
The 252LR connector meets ANSI/IEEE Standard 386, Latest Revision.
Are there any recommended safety accessories for the connector?
For safety purposes, a sealing and grounding kit is highly recommended with the deadbreak elbow.
What types of conductors are compatible with the compression lugs?
Bi-metal compression lugs are suitable for both copper or aluminum conductors, while copper compression lugs are for copper conductors only.
What is the continuous current rating for this connector?
The 252LR-W5X deadbreak elbow connector has a continuous current rating of 200 Amps for both 15kV and 25kV voltage classes.
What are the operating voltage ranges for the connector?
For 15kV class, the maximum phase-to-ground operating voltage is 8.3kV. For 25kV class, it is 15.2kV.
What is the 252LR-W5X connector's primary function?
The 252LR-W5X is a 15/25kV, 200 Amp Class dead-break elbow connector with an integral voltage test point. It is fully shielded and submersible.
What is the continuous current rating for this connector?
The 252LR-W5X deadbreak elbow connector has a continuous current rating of 200 Amps for both 15kV and 25kV voltage classes.
What is the 252LR-W5X connector's primary function?
The 252LR-W5X is a 15/25kV, 200 Amp Class dead-break elbow connector with an integral voltage test point. It is fully shielded and submersible.
What are the operating voltage ranges for the connector?
For 15kV class, the maximum phase-to-ground operating voltage is 8.3kV. For 25kV class, it is 15.2kV.
What types of conductors are compatible with the compression lugs?
Bi-metal compression lugs are suitable for both copper or aluminum conductors, while copper compression lugs are for copper conductors only.
How to Install the 252LR Deadbreak Elbow Connector
This guide provides step-by-step instructions for the safe and proper installation of the Elastimold 252LR Deadbreak Elbow Connector on UD cable having concentric neutral and semi-con shielding.
Tools needed:
Wrench, Wire brush, Crimp tool, Hot stick, Suitable voltage sensing device
Supplies needed:
252LR Elbow Connector Housing, Compression Lug, Probe, Probe Contact, Lubricant (supplied), Hold-down Bail, UD cable, No. 14 AWG (2.5mm) copper wire, Grounding connector
- Prepare for Installation and Ensure Safety
DANGER: Ensure all apparatus is de-energized before beginning installation. Do not touch or move energized products. This product must be installed by competent personnel trained in high voltage safety practices. Inspect all parts for damage, rating, and compatibility. Check package contents, verify elbow housing and compression lug sizes fit the cable, and thread the probe into the lug to check for resistance. Read all instructions, gather tools, and maintain cleanliness. If the test point cap is not installed, lubricate and install it.
- Train and Prepare the Cable
Train the UD cable to ease operation, ensuring a minimum of 20 inches (508.0mm) beyond the end of the cable pad mount transformer. Cut excess cable squarely at the center line of the bushing. Unwrap and bind concentric neutral wires 8-1/2 inches (216.0mm) back from the cable end. Remove the shield and insulation from the cable end, cutting squarely without nicking the conductor. Wire brush bare aluminum conductors and immediately install the compression lug, rotating to spread inhibitor. Align the lug's threaded hole with the bushing bore and crimp according to the lug's chart, rotating 180 degrees for each successive crimp. Carefully wipe excessive inhibitor from the lug and cable. Remove the semi-con shield as shown in the template, and bevel the insulation end a maximum of 1/8 inch (3.2mm). Thoroughly clean the insulation to remove all traces of conductive residue.
- Assemble the Elbow Connector
Clean and lubricate the cable insulation and the inside of the elbow housing with the supplied lubricant. DO NOT SUBSTITUTE other lubricants. Slide the elbow connector onto the cable using a back-and-forth twisting motion. Wipe off any excess silicone lubricant. Align the elbow with the compression lug's threaded hole. Thread the probe into the lug by hand, taking care not to cross-thread. Tighten the probe with the supplied wrench until the wrench bends, indicating proper torque.
- Assemble and Connect the Hold-down Bail and Neutral
Place the hold-down bail into the hold-down bracket. Using a separate No. 14 AWG (2.5mm) copper wire or equivalent, insert one end through the grounding eye on the elbow. Twist the wire tightly, ensuring not to damage the eye. Twist all concentric neutral wires together and connect them to ground using an appropriate connector, providing adequate slack for elbow operation.
- Connect Elbow to Bushing Plug
Clean the receptacle portion of the elbow connector and the mating bushing. LUBRICATE ONLY IF THE TRANSFORMER AND ELBOW ARE KNOWN TO BE DE-ENERGIZED with the supplied lubricant. Use a fully insulated hot stick to safely place the elbow onto the bushing. DO NOT OPERATE BY HAND. DO NOT SEPARATE IF ENERGIZED.
- Secure the Elbow with the Bail
Pull the hold-down bail up over the crown or top of the elbow so that the eyebolt on the bail is directly over the operating eye. Tighten down on the elbow locator by turning the eyebolt in a clockwise direction. Adjust the nut on the eyebolt until it allows the eyebolt to seat securely in the locator. The nut should act as a stop to prevent the eyebolt from applying excessive force on the elbow. Once the nut is in its final position, it will not need to be readjusted when removing and replacing the elbow.
- Perform Voltage Test (Post-Installation Verification)
To establish if the circuit is energized, remove the test point cap with a hotstick, peeling it off at an angle. WARNING: The voltage test point is a capacitance device and not directly connected to the conductor. Do not use conventional voltage measuring equipment. Use a suitable sensing device designed for capacitive test points to determine if the cable is energized. Contamination or incorrect equipment can give a false 'no voltage' indication; treat the elbow as energized until confirmed by other means. After testing, clean and lubricate the inside surface of the cap with silicone grease and replace it on the test point.
Frequently Asked Questions about ABB - Installation Products
How are Thomas and Betts products typically installed?
Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.
What accessories are available for Thomas and Betts products?
Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.
What environmental ratings do Thomas and Betts products have?
Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.
What communication protocols do Thomas and Betts products support?
Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.
What are the key features of Thomas and Betts products?
Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.
What are the main product lines offered by Thomas and Betts?
Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.
What technical support does Thomas and Betts offer?
Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.
What industries and applications are Thomas and Betts products used for?
Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.
What certifications and standards do Thomas and Betts products comply with?
Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.
What are the main product lines offered by Ocal?
Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.