ABB Installation Products K675LR-K2330 15/25kV, 900 Amps, Deadbreak Elbow without Test Point. Cable Insulation Diameter K…
UPC: 783786314164
Contact for Pricing
Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.
Overview
- 15/25kV voltage rating with 900A continuous current capacity
- Deadbreak design eliminates test point, simplifying installation and reducing failure points
- Supports cable insulation diameter K (1.090–1.310 inches / 27.689–33.274mm)
- Compatible with stranded/compressed 500 kcmil, solid/compact 600 kcmil, and 250/300 mmsq conductors
- Fully shielded, submersible molded rubber housing for harsh environments
Specifications
Amperage Rating | 900 A |
Application | 15/25kV, 900 Amp, Deadbreak Connector |
Color | Black |
Conductor Range | 500 kcmil , 600 kcmil |
Connection | Compression |
Connection Type | Deadbreak |
Current Rating | 900 A |
Environmental Conditions | All Weather Conditions, Fully Submersible |
Insulation | True |
Material | Copper, Poly |
Material | Housing - EPDM-Rubber |
Series | K |
Size | 10.36 inch X 13.00 inch from bottom to centerline of bushing, 3.38 inch Diameter |
Size | 1.090-1.310 inch (27.689-33.274mm) |
Special Features | Fully shielded, fully submersible molded rubber housing. 100 percent peroxide-cured construction includes insulation and conductive EPDM materials. Can be easily connected or disconnected using standard hand tools and equipment in a de-energized state |
Standard | ANSI/IEEE Standard 386 |
Temperature Rating, Maximum | 149 F |
Temperature Rating, Maximum | 65 C |
Temperature Rating, Minimum | -40 F |
Temperature Rating, Minimum | -40 C |
Type | Deadbreak Elbow Connector |
Voltage Rating | 15 to 25 kV |
Voltage Rating | 15/25kV |
Package Dimensions (L x W x H) | 0.01 IN x 0.01 IN x 0.01 IN |
Package Dimensions (L x W x H) | 0.0254 cm x 0.0254 cm x 0.0254 cm |
Package Weight (Imperial) | 7.2500 L |
Package Weight (Metric) | 3.2890 kg |

K675LR-L-2330-SG1
900 Amp, 15/25kV, 600 Series Elbow with Insulated Plug, Cap, Stud, Lug and Cable Adapter. Cable Insulation Diameter 1.180 inch to 1.465 inch. Copper Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 500 /Compacted Solid 600 /mmSquared Compact 250/300. Cold Shrinkable Seal with Copper Rod and Crimp Connector Included.
162LR-B5250-SG2
200 Amp, 15kV, Loadbreak Elbow Connector with Test Point, Cable Insulation Diameter 0.635 inch to 0.905 inch. Bi-Metal Compression Lug. Conductor Size AWG Compressed Stranded 2/0 /Solid 3/0 /mmSquared 67.43.
162LR-D2270
15kV, 200 Amps, Loadbreak Elbow Connector with Test Point. Cable Insulation Diameter .890-1.220 inches (22.61-30.99mm). Copper Compression Lug. Conductor Size 270 - 4/0 Stranded/Compressed or 250 kcmil Solid/Compact or 107.20 mmsq. No Sealing Kit. Includes Elbow Housing, Compression Lug, Probe, Probe Wrench, Tube of Lubricant, Crimp Chart, V.D. Cap - Peroxide, and Installation Instructions.
262LRJS-E5270
25kV, 200 Amps, Loadbreak Elbow, Built in Jacket Seal, Cable Insulation Diameter 1.090-1.310 inches, (27.69-33.27 mm), Bi-Metal Conductor, Conductor Size 4/0 Stranded/Compressed, 250 Solid/Compact. With Test Point. Kit Contains Elbow Connector Housing, Compression Lug, Probe, Probe Wrench, Lubricant, Installion Instruction Sheet and Crimp Chart.
262LRJS-A5210
25kV, 200 Amp Loadbreak Elbow with Test Point and Jacket Seal. Cable Insulation Diameter 0.575 - 0.740 inches (14.6-18.8mm). Bi-Metal Compression Lug. Conductor Size 210 - #3 Stranded/Compressed or #2 Solid/Compact. Kit Includes Elbow Connector Housing, Lug, Probe, Probe Wrench, Tube of Lubricant, Crimp Chart, V.D. Cap Peroxide and Installation Instructions.
376LR-K2240-S
200 Amp, 35kV, Loadbreak Elbow Connector with Test Point, Cable Insulation Diameter 1.090 inch to 1.310 inch. Copper Compression Lug, Conductor Size AWG Compressed Stranded 1/0, Solid 2/0, mmSquared 53.49. 200ECS Cold-Shrinkable Jacket Seal Included.Frequently Asked Questions
What is the K675LR designed for?
It provides fully shielded, dead-front submersible cable connections to high-voltage apparatus.
What are the 15kV operating voltage ratings?
For 15kV, the max phase-to-ground operating voltage is 8.3kV and max phase-to-phase is 14.4kV.
Is the K675LR suitable for submersible applications?
Yes, the K675LR features a fully shielded, fully submersible molded rubber housing.
What is the momentary current rating for K675LR?
The K675LR has a momentary current rating of 25kA Sym for 10 Cycles for both 15kV and 28kV voltage classes.
What is the continuous current rating for K675LR?
The K675LR has a continuous current rating of 900 Amp for both 15kV and 28kV voltage classes.
What are the 28kV operating voltage ratings?
For 28kV, the max phase-to-ground operating voltage is 16.2kV and max phase-to-phase is 28kV.
What other Elastimold products are compatible with K675LR?
The K675LR can be mated with K675CP, K675BIP, K675RTP, K675RTW, K675S1, K650J2, K650J3, and K650J4.
What insulation diameters does the K675LR support?
The K675LR supports insulation diameters from .640 inches to 1.935 inches.
What conductor sizes are compatible with K675LR?
It is compatible with #2 AWG to 1250 kcmil for aluminum and copper conductors.
What is the maximum voltage for the K675LR?
The K675LR can be used through 28kV.
How to Install 655/675LR and K655/K675LR Deadbreak Elbow Connectors
This guide provides step-by-step instructions for installing Elastimold 655/675LR and K655/K675LR deadbreak elbow connectors, designed for fully shielded, submersible cable connections to high voltage apparatus.
Estimated time: 1h 30m
Tools needed:
Cable cutting tool, Wire strippers, Wire brush, Crimping tool, Torque wrench, Hotstick, Suitable sensing device/meter
Supplies needed:
Elbow connector, Cable adapter, Compression lug, Insulating plug (optional), Lubricant, Threaded stud, No. 14 AWG Copper wire, Suitable grounding connector, Grounding device (optional), Waterproofing material, Tape marker, Cleaning supplies
- De-energize Apparatus and Inspect Components
DANGER: Ensure all apparatus is de-energized during installation or removal of parts. Do not touch or move energized products. Inspect all package contents to ensure they are complete and undamaged. Verify all components for proper fit with the cable and/or mating products. Have all required tools at hand and maintain cleanliness throughout the procedure.
- Prepare the Cable for Connection
Assemble the cable in its final position with enough slack for elbow removal. For concentric neutral cable, unwind the neutral wires. Cut the cable 1-3/4 inches (45mm) from the centerline of the mating product. Clean the outer surface of the cable for a distance of 24 inches (610mm) or up to the bent back concentric neutral wires. Remove the outer jacket (where applicable) and prepare the cable shield according to the specific cable type (e.g., Unishield, jacketed, non-jacketed, flat metallic tape, fabric tape, or longitudinally corrugated shield).
- Install and Lubricate Cable Adapter
Bevel the end of the cable insulation at a 45-degree angle, approximately 1/4 inch (6mm) back. Thoroughly clean and then lubricate the cable insulation, always working toward the semi-con shield. Install the cable adapter, small end first, until it is flush with the edge of the tape marker.
- Prepare and Measure Conductor
Remove the protruding cable insulation by cutting it even with the end of the cable adapter. Do not cut or nick the cable adapter or the conductor. Verify that the length of the exposed conductor is between 4-1/4 inches and 4-9/16 inches (108mm-116mm). If not, redo the assembly.
- Crimp Compression Lug
For copper conductors, fully insert the conductor into the compression lug. For aluminum conductors, wire brush the conductor and immediately fully insert it into the compression lug. Measure the 'Check Dimension' before crimping; it should be less than 6-3/8 inches. Crimp the compression lug according to the instructions supplied with the lug. Wipe all excess inhibitor from the compression lug and cable adapter surface after crimping. The distance from the end of the compression lug to the cable adapter after crimping should be between 6-3/8 inches to 7-1/8 inches (162mm-181mm). If not, redo the assembly.
- Install Elbow onto Cable Adapter
Lubricate the cable adapter and the inside of the elbow cable entrance. Install the elbow onto the cable adapter until it cannot advance further. Ensure the cable adapter remains flush with the tape marker. If not, reposition the cable adapter. Remove the tape marker.
- Connect Elbow to Mating Apparatus
DANGER: Do not connect or disconnect mating products while energized. Do not energize while disconnected. Remove protective caps from the elbow and the mating part. Hand tighten the threaded stud (supplied with the elbow) into the mating part if it is not already equipped with a stud. Clean and lubricate both the elbow and the mating part with the supplied lubricant. Push the elbow onto the mating part, aligning the hole in the compression lug with the stud. For the opposite end, clean and lubricate the mating part, insert it into the elbow, engage the threads, hand tighten, and then torque the mating part according to its specific instructions. CAUTION: When constructing 600amp L-Kits, tighten each component to the specified torque.
- Install Insulating Plug (If Applicable)
If an insulating plug is used as a mating part, clean and lubricate the inner surface of the voltage detection cap. Place the cap on the elbow and push down hard until it snaps into place.
- Ground the Cable Shield
Insert one end of a No. 14 AWG Copper wire (or equivalent ampacity) through the grounding eye and twist to form a small loop, taking care not to damage the eye. Connect this wire to ground using a suitable connector. The cable shield must be grounded either via a grounding device (following its instructions) or an alternate method if no device is used. It is also recommended to waterproof the cable jacket at this point to prevent moisture ingress.
- Perform Voltage Test
Remove the test point cap with a hotstick, peeling it off at an angle rather than pulling directly. WARNING: The voltage test point is a capacitance device, not directly connected to the conductor. Do not use conventional voltage measuring equipment. Use a suitable sensing device designed for capacitive test points to determine if the cable is energized. Treat the elbow as energized until a 'no voltage' indication is confirmed by other means, as contamination or incorrect equipment can provide false readings. After voltage detection, clean and lubricate the inside surface of the cap with silicone lubricant and replace it on the test point.
Frequently Asked Questions about ABB - Installation Products
How are Thomas and Betts products typically installed?
Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.
What accessories are available for Thomas and Betts products?
Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.
What environmental ratings do Thomas and Betts products have?
Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.
What communication protocols do Thomas and Betts products support?
Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.
What are the key features of Thomas and Betts products?
Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.
What are the main product lines offered by Thomas and Betts?
Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.
What technical support does Thomas and Betts offer?
Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.
What industries and applications are Thomas and Betts products used for?
Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.
What certifications and standards do Thomas and Betts products comply with?
Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.
What are the main product lines offered by Ocal?
Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.