ABB - Installation Products 162LR-D2270 - 15kV, 200 Amps, Loadbreak Elbow Connector with Test Point. Cable Insulation Diameter .890-1.220 inches (22.61-30.99mm). Copper Compression Lug. Conductor Size 270 - 4/0 Stranded/Compressed or 250 kcmil Solid/Compact or 107.20 mmsq. No Sealing Kit. Includes Elbow Housing, Compression Lug, Probe, Probe Wrench, Tube of Lubricant, Crimp Chart, V.D. Cap - Peroxide, and Installation Instructions.

ABB Installation Products 162LR-D2270 15kV, 200 Amps, Loadbreak Elbow Connector with Test Point. Cable Insulation Diameter…

UPC: 075114340618


Documents & Media
BrochureInstallation InstructionsManufacturer Product Website

Contact for Pricing

Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.

Overview

The ABB 162LR-D2270 is a 15kV, 200 Amp Loadbreak Elbow Connector designed for medium-voltage power distribution systems. This connector features a copper compression lug for secure, high-conductivity connections on conductors ranging from 270 - 4/0 AWG stranded/compressed, 250 kcmil solid/compact, or 107.20 mm². The elbow housing accommodates cable insulation diameters between 0.890 and 1.220 inches (22.61-30.99mm), making it compatible with a wide range of medium-voltage cables. A key feature of the 162LR-D2270 is the integrated test point, which enables safe circuit testing without system de-energization. This eliminates the need for temporary disconnections during maintenance or diagnostic procedures, reducing downtime and improving operational efficiency. The connector is part of ABB's Installation Products line, engineered for reliability in industrial and utility applications. The 162LR-D2270 includes all necessary installation components: elbow housing, copper compression lug, probe, probe wrench, lubricant tube, crimp chart, V.D. Cap (peroxide cured), and installation instructions. The compression lug is available in copper (standard) or bi-metal options, with conductor size codes ranging from 190 to 270 for precise matching. The catalog number selection follows a structured process: Step 1 determines insulation diameter (code D for 0.890-1.220"), Step 2 selects material code (5 for copper), and Step 3 chooses compression lug code (270 for 4/0 AWG or 250 kcmil). This loadbreak elbow connector is ideal for applications requiring safe, reliable medium-voltage connections, including switchgear, transformers, and cable terminations in industrial facilities, utilities, and commercial installations. The absence of a sealing kit makes it suitable for environments where additional environmental protection is not required.
  • 15kV rated, 200 Amp continuous current capacity
  • Integrated test point for safe circuit testing without de-energization
  • Copper compression lug for conductors 270 - 4/0 AWG stranded/compressed or 250 kcmil solid/compact
  • Cable insulation diameter compatibility: 0.890-1.220 inches (22.61-30.99mm)
  • Includes probe, wrench, lubricant, crimp chart, V.D. Cap, and installation instructions

Specifications

Amperage Rating
200 A
Application
15kV, 200 Amp, Loadbreak Connector
Color
Black
Conductor Range
4/0 STR/COMPR AWG , 250 kcmil
Connection
Push-In
Connection Type
LoadBreak Elbow Connector
Current Rating
200 A
Environmental Conditions
All Weather Conditions
Insulation
True
Material
Housing - EPDM-Rubber
Material
Copper
Series
162LR
Size
7.76 inch (197.1 mm) X 9.03 inch (229.4 mm), 2.92 inch (74.2 mm) Diameter
Size
0.890-1.220 inch insulation diameter
Special Features
15kV, 200 Amp Loadbreak Elbow. Fully shielded, fully submersible molded rubber housing. 100 percent peroxide-cured construction includes insulation and conductive EPDM materials. Provision for hot stick operation. Provision for ground wire connection. Wide cable range with minimum number of sizes. Long bi-metal compression lug is standard. Non-corrosive capacitive test point
Standard
ANSI/IEEE Standard 386
Temperature Rating, Maximum
149 F
Temperature Rating, Maximum
65 C
Temperature Rating, Minimum
-40 F
Temperature Rating, Minimum
-40 C
Type
Loadbreak Elbow Connector with Test Point
Voltage Rating
15 kV
Package Dimensions (L x W x H)
0.01 IN x 0.01 IN x 0.01 IN
Package Dimensions (L x W x H)
0.0254 cm x 0.0254 cm x 0.0254 cm
Package Weight (Imperial)
1.0000 L
Package Weight (Metric)
0.4540 kg
200 Amp, 15kV, Loadbreak Elbow Connector, Cable Insulation Diameter 0.805 inch to 1.060 inch. Bi-Metal Compression Lug. Conductor Size AWG Compressed Stranded 4/0 /Solid 250 /mmSquared 126.67. 200ECS Jacket Seal Included.

162LR-C5270-S

200 Amp, 15kV, Loadbreak Elbow Connector, Cable Insulation Diameter 0.805 inch to 1.060 inch. Bi-Metal Compression Lug. Conductor Size AWG Compressed Stranded 4/0 /Solid 250 /mmSquared 126.67. 200ECS Jacket Seal Included.
25kV, 200 Amps, Loadbreak Elbow, Built in Jacket Seal, Cable Insulation Diameter 1.090-1.310 inches, (27.69-33.27 mm), Bi-Metal Conductor, Conductor Size 4/0 Stranded/Compressed, 250 Solid/Compact. With Test Point. Kit Contains Elbow Connector Housing, Compression Lug, Probe, Probe Wrench, Lubricant, Installion Instruction Sheet and Crimp Chart.

262LRJS-E5270

25kV, 200 Amps, Loadbreak Elbow, Built in Jacket Seal, Cable Insulation Diameter 1.090-1.310 inches, (27.69-33.27 mm), Bi-Metal Conductor, Conductor Size 4/0 Stranded/Compressed, 250 Solid/Compact. With Test Point. Kit Contains Elbow Connector Housing, Compression Lug, Probe, Probe Wrench, Lubricant, Installion Instruction Sheet and Crimp Chart.
25kV, 200 Amp Loadbreak Elbow with Test Point and Jacket Seal. Cable Insulation Diameter 0.575 - 0.740 inches (14.6-18.8mm). Bi-Metal Compression Lug. Conductor Size 210 - #3 Stranded/Compressed or #2 Solid/Compact. Kit Includes Elbow Connector Housing, Lug, Probe, Probe Wrench, Tube of Lubricant, Crimp Chart, V.D. Cap Peroxide and Installation Instructions.

262LRJS-A5210

25kV, 200 Amp Loadbreak Elbow with Test Point and Jacket Seal. Cable Insulation Diameter 0.575 - 0.740 inches (14.6-18.8mm). Bi-Metal Compression Lug. Conductor Size 210 - #3 Stranded/Compressed or #2 Solid/Compact. Kit Includes Elbow Connector Housing, Lug, Probe, Probe Wrench, Tube of Lubricant, Crimp Chart, V.D. Cap Peroxide and Installation Instructions.
200 Amp, 35kV, Loadbreak Elbow Connector with Test Point, Cable Insulation Diameter 1.090 inch to 1.310 inch. Copper Compression Lug, Conductor Size AWG Compressed Stranded 1/0, Solid 2/0, mmSquared 53.49. 200ECS Cold-Shrinkable Jacket Seal Included.

376LR-K2240-S

200 Amp, 35kV, Loadbreak Elbow Connector with Test Point, Cable Insulation Diameter 1.090 inch to 1.310 inch. Copper Compression Lug, Conductor Size AWG Compressed Stranded 1/0, Solid 2/0, mmSquared 53.49. 200ECS Cold-Shrinkable Jacket Seal Included.
15/25kV, 600 Amp, Deadbreak Elbow Connector with Test Point, Cable Insulation Diameter 1.370-1.630 inches (34.798-41.402mm), Copper Lug, Conductor Size 330 - 500kcmil Stranded/Compressed, 600kcmil Solid/Compact. Kit Includes Elbow Connector Housing, Stud, Insulated Plug with Cap, Cable Adapter, V.D. Cap-Peroxide, Tube of Lubricant, Crimp Chart and Installations Instructions. 10.36 x 13.00 inches, 3.38 and 3.83 inch diameters.

K656LR-M2330

15/25kV, 600 Amp, Deadbreak Elbow Connector with Test Point, Cable Insulation Diameter 1.370-1.630 inches (34.798-41.402mm), Copper Lug, Conductor Size 330 - 500kcmil Stranded/Compressed, 600kcmil Solid/Compact. Kit Includes Elbow Connector Housing, Stud, Insulated Plug with Cap, Cable Adapter, V.D. Cap-Peroxide, Tube of Lubricant, Crimp Chart and Installations Instructions. 10.36 x 13.00 inches, 3.38 and 3.83 inch diameters.
35kV, 200 Amp, Loadbreak Elbow without Test Point, with Seal. Cable Insulation Diameter 0.850 - 1.050 inches (21.59-26.67mm). Copper Compression Lug. Conductor Size 260 - 3/0 Stranded/Compressed or 4/0 Solid/Compact. Kit Includes Elbow Connector Housing, Lug, Probe, Probe Wrench, Tube of Lubricant, Crimp Chart and Installation Instructions.

375LR-H2260-S

35kV, 200 Amp, Loadbreak Elbow without Test Point, with Seal. Cable Insulation Diameter 0.850 - 1.050 inches (21.59-26.67mm). Copper Compression Lug. Conductor Size 260 - 3/0 Stranded/Compressed or 4/0 Solid/Compact. Kit Includes Elbow Connector Housing, Lug, Probe, Probe Wrench, Tube of Lubricant, Crimp Chart and Installation Instructions.
200 Amp, 35kV, Loadbreak Elbow Connector with Test Point, Cable Insulation Diameter 1.090 inch to 1.310 inch. Copper Compression Lug, Conductor Size AWG Compressed Stranded 2/0, Solid 3/0, mmSquared 67.43. 200ECS Cold-Shrinkable Jacket Seal Included.

376LR-K2250-S

200 Amp, 35kV, Loadbreak Elbow Connector with Test Point, Cable Insulation Diameter 1.090 inch to 1.310 inch. Copper Compression Lug, Conductor Size AWG Compressed Stranded 2/0, Solid 3/0, mmSquared 67.43. 200ECS Cold-Shrinkable Jacket Seal Included.
25kV 200 Amp, Loadbreak Elbow Connector with Test Point, .890 inch - 1.220 Inch Cable Insulation Diameter, 4/0 Stranded Wire Size, Copper Compression Lug.

262LR-D2270

25kV 200 Amp, Loadbreak Elbow Connector with Test Point, .890 inch - 1.220 Inch Cable Insulation Diameter, 4/0 Stranded Wire Size, Copper Compression Lug.

Frequently Asked Questions

What is the purpose of the rigid probe support?

The internal rigid probe support ensures proper switching and easy probe installation.

What is the Elastimold 200 amp loadbreak elbow?

It is an enhanced 200 amp loadbreak elbow available in 15 kV and 25 kV series, designed for switching operations. It incorporates innovative design for safety, flexibility, and cost reduction.

What are the voltage ratings for this loadbreak elbow?

The Elastimold 200 amp loadbreak elbow is available for 15 kV and 25 kV applications.

What safety features does the enhanced elbow include?

It features improved insulation for 15 kV elbows, rigid probe support for proper switching, a no-stick interface with Elastimold bushings, a robust stainless-steel pulling eye, and dual grounding eye positions.

What standards and certifications does the product meet?

The enhanced Elastimold 200 amp loadbreak elbow is IEEE 386 compliant and has ANSI certification. It also has Rural Utilities Service (RUS) acceptance from the USDA.

How does the enhanced design improve product flexibility?

The enhanced design offers additional sizes, improved wider cable ranges, an easy order system, and an optional integral jacket seal.

Is an optional integral jacket seal available for the elbow?

Yes, the enhanced Elastimold 200 amp loadbreak elbow offers an optional integral jacket seal.

How does the elbow reduce life cycle costs?

It is optimized for switching operations, provides lifetime ease of operation and non-stick performance when used with Elastimold bushings, and has an improved seal system.

What material is the pulling eye made from?

The enhanced Elastimold 200 amp loadbreak elbow features a robust stainless-steel pulling eye.

What is the purpose of the rigid probe support?

The internal rigid probe support ensures proper switching and easy probe installation.

How to Install 161LR/162LR Loadbreak Elbow Connectors

This guide provides step-by-step instructions for the safe installation and initial setup of 161LR (without test point) and 162LR (with test point) Loadbreak Elbow Connectors on various UD cables. Ensure all safety precautions are followed.

Estimated time: 1h 30m

Tools needed:

Probe wrench, Wire brush, Crimp tool, Hotstick tool, Wire strippers, Cable cutting tool, Suitable voltage sensing device

Supplies needed:

Elbow Connector Housing, Compression Lug, Probe, Lubricant (Do Not Substitute), No. 14 AWG (2.5mm) copper wire, Appropriate neutral wire connector

  1. Perform Pre-Installation Safety Checks and Part Inspection

    DANGER: Ensure all apparatus are de-energized before beginning installation or removal of parts. This product must be installed only by competent personnel trained in high voltage electrical safety. Inspect all package contents to confirm they are complete and undamaged. Verify all components fit properly with the cable and mating products. Check the probe threads by hand-threading the probe into the compression lug; if resistance is encountered, replace the damaged component.

  2. Prepare the Cable for Termination

    Train the cable to ensure adequate slack for future operation. Depending on the cable type (non-jacketed, jacketed concentric neutral, jacketed with drain wires, or jacketed copper tape shield), prepare the neutral wires or shield according to the specific instructions for your cable type, including removing the outer jacket to the specified length (e.g., 9-5/8 inches for jacketed concentric neutral cable). Cut the excess cable squarely at the bushing centerline.

  3. Prepare Conductor and Insulation

    Remove 2-1/8 inches (55mm) of the shield and insulation from the cable end, cutting squarely and taking care not to nick the conductor. Wire brush bare aluminum conductors and immediately install the compression lug, rotating it to spread inhibitor. Position the lug so the contact threaded hole aligns with the bushing bore. Crimp the lug according to the manufacturer's chart, starting at the crimp line mark and rotating 180 degrees for each successive crimp. Carefully wipe off any excess inhibitor. Remove the insulation shield as shown in the diagram, and bevel the insulation end by a maximum of 1/8 inch (5mm). Thoroughly clean the insulation to remove all traces of dirt or excess inhibitor.

  4. Assemble the Elbow Connector

    Lubricate the cable insulation and the inside of the elbow housing with the supplied lubricant; DO NOT SUBSTITUTE other lubricants. Slide the elbow connector onto the cable using a back-and-forth twisting motion, then wipe off all excess lubricant. Align the elbow with the compression lug's threaded hole. Thread the probe into the lug by hand, ensuring it turns freely for approximately four turns before becoming snug. Tighten the probe with the supplied wrench until the wrench bends.

  5. Connect Grounding Wires

    Insert one end of a separate No. 14 AWG (2.5mm) copper wire or equivalent through the grounding eye on the elbow and twist it tightly, being careful not to damage the eye. Twist all neutral wires together and connect them to ground using an appropriate connector, ensuring adequate slack for elbow operation.

  6. Connect Elbow to Bushing Plug

    DANGER: CONFIRM THAT THE TRANSFORMER AND ELBOW ARE DE-ENERGIZED before proceeding. Lubricate the receptacle portion of the elbow connector and the mating bushing with the supplied lubricant. Securely fasten a hotstick to the loadbreak connector pulling eye. Insert the probe tip approximately 2 inches (50mm) into the bushing, then immediately push the elbow home with a fast, firm, straight motion to engage the internal lock. DO NOT OPERATE BY HAND.

  7. Perform Voltage Test (162LR only)

    If using a 162LR connector with a test point, remove the test point cap with a hotstick, peeling it off at an angle. WARNING: The voltage test point is a capacitance device and is not directly connected to the conductor. Do not use conventional voltage measuring equipment. Use a suitable sensing device designed for capacitive test points to determine if the cable is energized. Treat the elbow as energized until the 'no voltage' indication is confirmed by other means. After testing, clean the inside surface of the cap, lubricate it with silicone lubricant, and replace it on the test point.

Frequently Asked Questions about ABB - Installation Products

How are Thomas and Betts products typically installed?

Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.

What accessories are available for Thomas and Betts products?

Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.

What environmental ratings do Thomas and Betts products have?

Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.

What communication protocols do Thomas and Betts products support?

Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.

What are the key features of Thomas and Betts products?

Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.

What are the main product lines offered by Thomas and Betts?

Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.

What technical support does Thomas and Betts offer?

Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.

What industries and applications are Thomas and Betts products used for?

Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.

What certifications and standards do Thomas and Betts products comply with?

Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.

What are the main product lines offered by Ocal?

Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.