ABB - Installation Products 262LR-B5230 - 25kV 200 Amp, Loadbreak Elbow Connector with Test Point, .635 inch - .905 inch Cable Insulation Diameter, #1 Stranded Wire Size, Bi-Metal Compression Lug.
More images

ABB Installation Products 262LR-B5230 25kV 200 Amp, Loadbreak Elbow Connector with Test Point, .635 inch - .905 inch Cable…

UPC: 075114191913


Documents & Media
BrochureInstallation InstructionsSpecification SheetManufacturer Product Website

Contact for Pricing

Call (262) 252-1600 or email [email protected] for pricing and availability.

Overview

The ABB 262LR-B5230 Loadbreak Elbow Connector is a 25kV, 200 Amp rated device designed for underground distribution systems. It accommodates cable insulation diameters from 0.635 inches to 0.905 inches and supports #1 AWG stranded copper wire. The bi-metal compression lug ensures compatibility with both copper and aluminum conductors, providing reliable electrical continuity. The integrated test point allows for safe voltage verification without disconnecting the elbow, reducing downtime during maintenance or fault detection. This connector is part of ABB’s Installation Products line, known for compliance with industry standards for loadbreak separable connectors. Typical applications include pad-mounted transformers, switchgear, and underground residential or commercial distribution networks. The elbow design enables quick installation and removal, minimizing labor costs in confined spaces. Rated for 200 Amps continuous current, it meets the demands of medium-voltage distribution systems where safe, loadbreak operation is required. The connector’s compact form factor and durable construction support long-term reliability in outdoor or indoor environments.
  • 25kV rated, 200 Amp continuous current capacity
  • Loadbreak design for safe live-line disconnection
  • Test point for voltage verification without disassembly
  • Bi-metal compression lug for copper and aluminum conductors
  • Compatible with .635in to .905in cable insulation diameters

Specifications

Amperage Rating
200 A
Application
200 kV, 200 Amp
Color
Black
Conductor Range
#1 STR/COMPR AWG , 1/0 SOL/COMPT AWG
Environmental Conditions
All Weather Conditions
Insulation
True
Material
Housing - EPDM-Rubber
Size
9.03 inch (299.4 mm) X 8.20 inch (208.3 mm) not including probe, 2.86 inch (72.6 mm) Diameter
Special Features
28kV, 200 Amp Loadbreak Elbow. Fully shielded, fully submersible molded rubber housing. 100 percent peroxide-cured construction includes insulation and conductive EPDM materials. Provision for hot stick operation. Provision for ground wire connection. Wide cable range with minimum number of sizes. Long bi-metal compression lug is standard. Non-corrosive capacitive test point
Standard
ANSI/IEEE Standard 386
Temperature Rating, Maximum
149 F
Temperature Rating, Maximum
65 C
Temperature Rating, Minimum
-40 F
Temperature Rating, Minimum
-40 C
Type
Loadbreak Elbow Connector with Test Point
Voltage Rating
28 kV
Package Dimensions (L x W x H)
0.01 IN x 0.01 IN x 0.01 IN
Package Dimensions (L x W x H)
0.0254 cm x 0.0254 cm x 0.0254 cm
Package Weight (Imperial)
1.0000 L
Package Weight (Metric)
0.4540 kg
25kV, 200 Amps, Loadbreak Elbow, Cable Insulation Diameter 1.090-1.310 inches, (27.69-33.27 mm), Bi-Metal Conductor, Conductor Size #1 Stranded/Compressed, 1/0 Solid/Compact. With Test Point. 200ECS-G2 Jacket Seal and Grounding Kit Included. Kit Contains Elbow Connector Housing, Compression Lug, Probe, Probe Wrench, Lubricant, Installion Instruction Sheet and Crimp Chart.

262LR-E5230-SG2

25kV, 200 Amps, Loadbreak Elbow, Cable Insulation Diameter 1.090-1.310 inches, (27.69-33.27 mm), Bi-Metal Conductor, Conductor Size #1 Stranded/Compressed, 1/0 Solid/Compact. With Test Point. 200ECS-G2 Jacket Seal and Grounding Kit Included. Kit Contains Elbow Connector Housing, Compression Lug, Probe, Probe Wrench, Lubricant, Installion Instruction Sheet and Crimp Chart.
6MM2 BLACK CABLE FOR DISTRIBUTION BLOCK ROW TYPE LENGTH 320MM

54211116

6MM2 BLACK CABLE FOR DISTRIBUTION BLOCK ROW TYPE LENGTH 320MM
200 Amp, 15kV, Loadbreak Elbow Connector, Cable Insulation Diameter 0.805 inch to 1.060 inch. Bi-Metal Compression Lug. Conductor Size AWG Compressed Stranded 3/0 /Solid 4/0 /mmSquared 85.01. 200ECS-G3 Jacket Seal and Grounding Kit Included.

162LR-C5260-SG3

200 Amp, 15kV, Loadbreak Elbow Connector, Cable Insulation Diameter 0.805 inch to 1.060 inch. Bi-Metal Compression Lug. Conductor Size AWG Compressed Stranded 3/0 /Solid 4/0 /mmSquared 85.01. 200ECS-G3 Jacket Seal and Grounding Kit Included.
15kV 200 Amp, Loadbreak Elbow Connector with Test Point, .890 inch - 1.220 Inch Cable Insulation Diameter, 1/0 Stranded Wire Size, Bi-Metal Compression Lug

162LR-D5240

15kV 200 Amp, Loadbreak Elbow Connector with Test Point, .890 inch - 1.220 Inch Cable Insulation Diameter, 1/0 Stranded Wire Size, Bi-Metal Compression Lug
15kV 200 Amp, Loadbreak Elbow Connector with Test Point, .890 inch - 1.220 Inch Cable Insulation Diameter, 2/0 Stranded, 2/0 Solid Wire Size, Bi-Metal Compression Lug, No Sealing Kit

162LR-D5250

15kV 200 Amp, Loadbreak Elbow Connector with Test Point, .890 inch - 1.220 Inch Cable Insulation Diameter, 2/0 Stranded, 2/0 Solid Wire Size, Bi-Metal Compression Lug, No Sealing Kit
200 Amp, 15kV, Loadbreak Elbow Connector, Cable Insulation Diameter 0.805 inch to 1.060 inch. Bi-Metal Compression Lug. Conductor Size AWG Compressed Stranded 4/0 /Solid 250 /mmSquared 126.67. 200ECS Jacket Seal Included.

162LR-C5270-S

200 Amp, 15kV, Loadbreak Elbow Connector, Cable Insulation Diameter 0.805 inch to 1.060 inch. Bi-Metal Compression Lug. Conductor Size AWG Compressed Stranded 4/0 /Solid 250 /mmSquared 126.67. 200ECS Jacket Seal Included.
15kV 200 Amp, Loadbreak Elbow Connector with Test Point, .805 inch - 1.060 Inch Cable Insulation Diameter, 2/0 Stranded Wire Size, Bi-Metal Compression Lug

162LR-C5250

15kV 200 Amp, Loadbreak Elbow Connector with Test Point, .805 inch - 1.060 Inch Cable Insulation Diameter, 2/0 Stranded Wire Size, Bi-Metal Compression Lug
200 Amp, 15kV, Loadbreak Elbow Connector, Cable Insulation Diameter 0.805 inch to 1.060 inch. Bi-Metal Compression Lug. Conductor Size AWG Compressed Stranded 2/0 /Solid 3/0 /mmSquared 67.43. 200ECS-G3 Jacket Seal and Grounding Kit Included.

162LR-C5250-SG3

200 Amp, 15kV, Loadbreak Elbow Connector, Cable Insulation Diameter 0.805 inch to 1.060 inch. Bi-Metal Compression Lug. Conductor Size AWG Compressed Stranded 2/0 /Solid 3/0 /mmSquared 67.43. 200ECS-G3 Jacket Seal and Grounding Kit Included.

Frequently Asked Questions

What certifications does the loadbreak elbow have?

It is IEEE 386 compliant, ANSI certified, and has Rural Utilities Service (RUS) acceptance.

What is the ABB Elastimold product?

The product is an enhanced Elastimold 200 amp loadbreak elbow.

What are the voltage ratings for this elbow?

The loadbreak elbow is designed for 15 kV and 25 kV series applications.

What certifications does the loadbreak elbow have?

It is IEEE 386 compliant, ANSI certified, and has Rural Utilities Service (RUS) acceptance.

What is the ABB Elastimold product?

The product is an enhanced Elastimold 200 amp loadbreak elbow.

What are the voltage ratings for this elbow?

The loadbreak elbow is designed for 15 kV and 25 kV series applications.

What are the voltage ratings for this elbow?

The loadbreak elbow is designed for 15 kV and 25 kV series applications.

What is the ABB Elastimold product?

The product is an enhanced Elastimold 200 amp loadbreak elbow.

What certifications does the loadbreak elbow have?

It is IEEE 386 compliant, ANSI certified, and has Rural Utilities Service (RUS) acceptance.

What is the ABB Elastimold product?

The product is an enhanced Elastimold 200 amp loadbreak elbow.

How to Install 261LR/262LR Loadbreak Elbow Connectors

This guide provides step-by-step instructions for the safe and proper installation of 261LR and 262LR Loadbreak Elbow Connectors on various underground distribution cables. It covers cable preparation, lug installation, elbow assembly, grounding, and final connection to a bushing.

Estimated time: 1h

Tools needed:

Wire strippers, Cable cutting tool, Wire brush, Crimp tool, Probe wrench, Hotstick

Supplies needed:

Elbow Connector Housing, Compression Lug, Probe, Lubricant (Do Not Substitute), No. 14 AWG / 2.5mm Copper wire, Appropriate connector for neutral wires, Cold shrink tube (if using sealing kits), Conductive copper tape (if using 200ECS-G2 kit), Vinyl tape (if using Jacketed Cable with Drain Wires)

  1. Perform Pre-Installation Checks

    Check package contents to ensure they are complete and undamaged. Verify all components fit properly with the cable and/or mating products. Thread the probe into the compression lug to check for damage; it should turn freely for approximately four turns before becoming snug. Read all installation instructions thoroughly and gather all required tools. DANGER: All apparatus must be de-energized during installation or removal of parts. This product should only be installed by competent personnel trained in good safety practices involving high voltage electrical equipment.

  2. Prepare the Cable for Termination

    Train the cable to ensure sufficient slack for ease of operation. Prepare the neutral wires or grounding braid wire according to your specific cable type (non-jacketed concentric neutral, jacketed concentric neutral, jacketed with drain wires, or jacketed copper tape shield cable) to allow for connection to the tank ground and hotstick operation. This typically involves pulling extra cable, binding neutrals, or removing the outer jacket and unwrapping drain/neutral wires. Cut the excess cable squarely at the centerline of the bushing. If using a cold shrink sealing kit (e.g., 200ECS, 200ECS-G1, 200ECS-G2), slide the cold shrink tube onto the cable loose end first at this stage.

  3. Strip Cable and Install Compression Lug

    Remove the insulation shield and insulation 2-1/8 inches (55mm) from the cable end, cutting squarely and taking care not to nick the conductor. Wire brush bare aluminum conductors immediately. Install the compression lug, rotating it to spread inhibitor. Position the lug so the contact threaded hole aligns with the bushing bore. Crimp the lug according to the manufacturer's chart, starting at the crimp line mark and rotating 180 degrees for each successive crimp. Carefully wipe any excess inhibitor from the outside of the lug and cable. Remove the insulation shield 6-7/8 inches (175mm) back from the lug. Bevel the insulation end a maximum of 1/8 inch (5mm), ensuring it is straight, smooth, and squared without nicks. Thoroughly clean the insulation to remove all traces of dirt or excess inhibitor.

  4. Assemble the Elbow Connector

    Lubricate the cable insulation and the inside of the elbow housing with the supplied lubricant. DO NOT SUBSTITUTE other lubricants, as they may be harmful to this product or its mating product(s). Keep the insulation clean of dirt and grime. Slide the elbow connector onto the cable using a back-and-forth twisting motion. Wipe off all excess lubricant. Align the elbow with the compression lug’s threaded hole. Thread the probe into the lug by hand, taking care not to cross-thread. The probe must turn freely for approximately four turns before becoming snug. Tighten the probe with the probe wrench until the wrench bends, indicating proper torque.

  5. Connect Grounding and Neutrals

    Insert one end of a separate No. 14 AWG (2.5mm) copper wire or equivalent through the grounding eye on the elbow. Twist it tightly, taking care not to damage the eye. (If the elbow is preordered with ground wire, skip this part). Twist all neutral wires together and connect them to ground using an appropriate connector. Provide adequate slack in the wires for elbow operation. If using a cold shrink grounding kit, refer to the instructions supplied with that kit to complete the grounding installation.

  6. Connect Elbow to Bushing Plug

    DANGER: CONFIRM THAT THE TRANSFORMER AND ELBOW ARE DE-ENERGIZED before proceeding with this connection. Lubricate the receptacle portion of the elbow connector and the mating bushing with the lubricant supplied. Using a full insulated “hotstick” type live-line tool, connect the elbow to the bushing. DO NOT OPERATE BY HAND.

Frequently Asked Questions about ABB - Installation Products

How are Thomas and Betts products typically installed?

Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.

What accessories are available for Thomas and Betts products?

Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.

What environmental ratings do Thomas and Betts products have?

Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.

What communication protocols do Thomas and Betts products support?

Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.

What are the key features of Thomas and Betts products?

Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.

What are the main product lines offered by Thomas and Betts?

Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.

What technical support does Thomas and Betts offer?

Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.

What industries and applications are Thomas and Betts products used for?

Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.

What certifications and standards do Thomas and Betts products comply with?

Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.

What are the main product lines offered by Ocal?

Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.