Authorized ABB Distributor (Installation Products)
ABB - Installation Products 162LR-B5250-SG2 - 200 Amp, 15kV, Loadbreak Elbow Connector with Test Point, Cable Insulation Diameter 0.635 inch to 0.905 inch. Bi-Metal Compression Lug. Conductor Size AWG Compressed Stranded 2/0 /Solid 3/0 /mmSquared 67.43.

ABB Installation Products 162LR-B5250-SG2 200 Amp, 15kV, Loadbreak Elbow Connector with Test Point, Cable Insulation Diameter…

UPC: 075114339292


Documents & Media
BrochureInstallation InstructionsSpecification SheetManufacturer Product Website

Contact for Pricing

Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.

Overview

The ABB 162LR-B5250-SG2 is a 200 Amp, 15kV loadbreak elbow connector designed for reliable power distribution applications. This connector features a built-in test point for safe and efficient voltage testing, crucial for maintenance and troubleshooting in electrical systems. Engineered for cable insulation diameters ranging from 0.635 inches to 0.905 inches, it ensures a secure and dependable connection. The integrated bi-metal compression lug is suitable for compressed stranded conductors from 2/0 AWG up to 3/0 AWG solid (67.43 mm²), providing robust electrical contact. This connector is a key component for underground distribution systems, substations, and industrial power infrastructure where reliable loadbreak capabilities are essential. The ABB Installation Products brand signifies a commitment to quality and performance in electrical connection solutions. SKU: 162LR-B5250-SG2. UNSPSC Code: 39121421.
  • 200 Amp, 15kV Loadbreak Elbow Connector
  • Integrated Test Point for Voltage Testing
  • Accommodates Cable Insulation Diameter: 0.635" - 0.905"
  • Bi-Metal Compression Lug for Conductor Sizes: 2/0 AWG Stranded / 3/0 AWG Solid (67.43 mm²)
  • Manufacturer: ABB - Installation Products

Specifications

Amperage Rating
200 A
Application
15kV, 200 Amp
Color
Black
Conductor Range
2/0 STR/COMPR AWG , 3/0 SOL/COMPT AWG
Connection
Push-In
Environmental Conditions
All Weather Conditions
Insulation
True
Material
Housing - EPDM-Rubber
Size
7.76 inch (197.1 mm) X 9.03 inch (229.4 mm), 2.92 inch (74.2 mm) Diameter
Special Features
15kV, 200 Amp Loadbreak Elbow. Fully shielded, fully submersible molded rubber housing. 100 percent peroxide-cured construction includes insulation and conductive EPDM materials. Provision for hot stick operation. Provision for ground wire connection. Wide cable range with minimum number of sizes. Long bi-metal compression lug is standard. Non-corrosive capacitive test point
Standard
ANSI/IEEE Standard 386
Temperature Rating, Maximum
149 F
Temperature Rating, Maximum
65 C
Temperature Rating, Minimum
-40 F
Temperature Rating, Minimum
-40 C
Type
Loadbreak Elbow Connector with Test Point
Voltage Rating
15 kV
Package Dimensions (L x W x H)
0.01 IN x 0.01 IN x 0.01 IN
Package Dimensions (L x W x H)
0.0254 cm x 0.0254 cm x 0.0254 cm
Package Weight (Imperial)
1.0000 L
Package Weight (Metric)
0.4540 kg
200 Amp, 15kV, Loadbreak Elbow Connector, Cable Insulation Diameter 0.635 inch to 0.905 inch. Bi-Metal Compression Lug. Conductor Size AWG Compressed Stranded 2/0 /Solid 3/0 /mmSquared 67.43. 200ECS-G3 Jacket Seal and Grounding Kit Included.

162LR-B5250-SG3

200 Amp, 15kV, Loadbreak Elbow Connector, Cable Insulation Diameter 0.635 inch to 0.905 inch. Bi-Metal Compression Lug. Conductor Size AWG Compressed Stranded 2/0 /Solid 3/0 /mmSquared 67.43. 200ECS-G3 Jacket Seal and Grounding Kit Included.
15kV, 200 Amps, Loadbreak Elbow Connector with Test Point. Cable Insulation Diameter .890-1.220 inches (22.61-30.99mm). Copper Compression Lug. Conductor Size 270 - 4/0 Stranded/Compressed or 250 kcmil Solid/Compact or 107.20 mmsq. No Sealing Kit. Includes Elbow Housing, Compression Lug, Probe, Probe Wrench, Tube of Lubricant, Crimp Chart, V.D. Cap - Peroxide, and Installation Instructions.

162LR-D2270

15kV, 200 Amps, Loadbreak Elbow Connector with Test Point. Cable Insulation Diameter .890-1.220 inches (22.61-30.99mm). Copper Compression Lug. Conductor Size 270 - 4/0 Stranded/Compressed or 250 kcmil Solid/Compact or 107.20 mmsq. No Sealing Kit. Includes Elbow Housing, Compression Lug, Probe, Probe Wrench, Tube of Lubricant, Crimp Chart, V.D. Cap - Peroxide, and Installation Instructions.
25kV, 200 Amps, Loadbreak Elbow, Built in Jacket Seal, Cable Insulation Diameter 1.090-1.310 inches, (27.69-33.27 mm), Bi-Metal Conductor, Conductor Size 4/0 Stranded/Compressed, 250 Solid/Compact. With Test Point. Kit Contains Elbow Connector Housing, Compression Lug, Probe, Probe Wrench, Lubricant, Installion Instruction Sheet and Crimp Chart.

262LRJS-E5270

25kV, 200 Amps, Loadbreak Elbow, Built in Jacket Seal, Cable Insulation Diameter 1.090-1.310 inches, (27.69-33.27 mm), Bi-Metal Conductor, Conductor Size 4/0 Stranded/Compressed, 250 Solid/Compact. With Test Point. Kit Contains Elbow Connector Housing, Compression Lug, Probe, Probe Wrench, Lubricant, Installion Instruction Sheet and Crimp Chart.
25kV, 200 Amp Loadbreak Elbow with Test Point and Jacket Seal. Cable Insulation Diameter 0.575 - 0.740 inches (14.6-18.8mm). Bi-Metal Compression Lug. Conductor Size 210 - #3 Stranded/Compressed or #2 Solid/Compact. Kit Includes Elbow Connector Housing, Lug, Probe, Probe Wrench, Tube of Lubricant, Crimp Chart, V.D. Cap Peroxide and Installation Instructions.

262LRJS-A5210

25kV, 200 Amp Loadbreak Elbow with Test Point and Jacket Seal. Cable Insulation Diameter 0.575 - 0.740 inches (14.6-18.8mm). Bi-Metal Compression Lug. Conductor Size 210 - #3 Stranded/Compressed or #2 Solid/Compact. Kit Includes Elbow Connector Housing, Lug, Probe, Probe Wrench, Tube of Lubricant, Crimp Chart, V.D. Cap Peroxide and Installation Instructions.
200 Amp, 35kV, Loadbreak Elbow Connector with Test Point, Cable Insulation Diameter 1.090 inch to 1.310 inch. Copper Compression Lug, Conductor Size AWG Compressed Stranded 1/0, Solid 2/0, mmSquared 53.49. 200ECS Cold-Shrinkable Jacket Seal Included.

376LR-K2240-S

200 Amp, 35kV, Loadbreak Elbow Connector with Test Point, Cable Insulation Diameter 1.090 inch to 1.310 inch. Copper Compression Lug, Conductor Size AWG Compressed Stranded 1/0, Solid 2/0, mmSquared 53.49. 200ECS Cold-Shrinkable Jacket Seal Included.
15/25kV, 600 Amp, Deadbreak Elbow Connector with Test Point, Cable Insulation Diameter 1.370-1.630 inches (34.798-41.402mm), Copper Lug, Conductor Size 330 - 500kcmil Stranded/Compressed, 600kcmil Solid/Compact. Kit Includes Elbow Connector Housing, Stud, Insulated Plug with Cap, Cable Adapter, V.D. Cap-Peroxide, Tube of Lubricant, Crimp Chart and Installations Instructions. 10.36 x 13.00 inches, 3.38 and 3.83 inch diameters.

K656LR-M2330

15/25kV, 600 Amp, Deadbreak Elbow Connector with Test Point, Cable Insulation Diameter 1.370-1.630 inches (34.798-41.402mm), Copper Lug, Conductor Size 330 - 500kcmil Stranded/Compressed, 600kcmil Solid/Compact. Kit Includes Elbow Connector Housing, Stud, Insulated Plug with Cap, Cable Adapter, V.D. Cap-Peroxide, Tube of Lubricant, Crimp Chart and Installations Instructions. 10.36 x 13.00 inches, 3.38 and 3.83 inch diameters.
35kV, 200 Amp, Loadbreak Elbow without Test Point, with Seal. Cable Insulation Diameter 0.850 - 1.050 inches (21.59-26.67mm). Copper Compression Lug. Conductor Size 260 - 3/0 Stranded/Compressed or 4/0 Solid/Compact. Kit Includes Elbow Connector Housing, Lug, Probe, Probe Wrench, Tube of Lubricant, Crimp Chart and Installation Instructions.

375LR-H2260-S

35kV, 200 Amp, Loadbreak Elbow without Test Point, with Seal. Cable Insulation Diameter 0.850 - 1.050 inches (21.59-26.67mm). Copper Compression Lug. Conductor Size 260 - 3/0 Stranded/Compressed or 4/0 Solid/Compact. Kit Includes Elbow Connector Housing, Lug, Probe, Probe Wrench, Tube of Lubricant, Crimp Chart and Installation Instructions.
200 Amp, 35kV, Loadbreak Elbow Connector with Test Point, Cable Insulation Diameter 1.090 inch to 1.310 inch. Copper Compression Lug, Conductor Size AWG Compressed Stranded 2/0, Solid 3/0, mmSquared 67.43. 200ECS Cold-Shrinkable Jacket Seal Included.

376LR-K2250-S

200 Amp, 35kV, Loadbreak Elbow Connector with Test Point, Cable Insulation Diameter 1.090 inch to 1.310 inch. Copper Compression Lug, Conductor Size AWG Compressed Stranded 2/0, Solid 3/0, mmSquared 67.43. 200ECS Cold-Shrinkable Jacket Seal Included.

Frequently Asked Questions

Is the product ANSI certified?

Yes, the enhanced Elastimold 200 amp loadbreak elbow has ANSI certification.

Is the product IEEE 386 compliant?

Yes, the enhanced Elastimold 200 amp loadbreak elbow is IEEE 386 compliant.

What is the expected operational ease with Elastimold bushings?

It offers lifetime ease of operation and remains non-stick when used with Elastimold bushings.

Is an integral jacket seal available?

Yes, an optional integral jacket seal is available for the enhanced Elastimold 200 amp loadbreak elbow.

What material is the pulling eye made of?

The pulling eye is made of robust stainless steel, promoting durable hotstick control.

Does the elbow prevent sticking with bushings?

Yes, it features a no-stick interface when used with Elastimold bushings, which has been NEETRAC tested.

Does the product have RUS acceptance?

Yes, the enhanced Elastimold 200 amp loadbreak elbow has Rural Utilities Service (RUS) acceptance from the USDA. This authorizes its use in rural infrastructure construction.

What is the product's current and voltage rating?

The product is a 200 amp loadbreak elbow designed for 15 kV and 25 kV systems.

Is the product IEEE 386 compliant?

Yes, the enhanced Elastimold 200 amp loadbreak elbow is IEEE 386 compliant.

Does the elbow prevent sticking with bushings?

Yes, it features a no-stick interface when used with Elastimold bushings, which has been NEETRAC tested.

How to Install 161LR/162LR Loadbreak Elbow Connectors

This guide provides step-by-step instructions for the safe and proper installation of 161LR and 162LR Loadbreak Elbow Connectors, including cable preparation, assembly, and grounding procedures.

Estimated time: 1h

Tools needed:

Probe wrench, Wire brush, Crimp tool, Wire strippers, Hotstick tool

Supplies needed:

Lubricant (supplied), Compression lug, Probe, Copper wire (No. 14 AWG / 2.5mm) or equivalent, Appropriate neutral wire connector, Cold shrink tube (if applicable), Conductive copper tape (if applicable), Vinyl tape (if applicable)

  1. Perform Initial Checks and Safety Review

    DANGER: Ensure all apparatus is de-energized during installation or removal of parts. This product must be installed only by competent personnel trained in high voltage electrical equipment safety practices. Inspect all package contents for completeness and damage. Verify all components are compatible with the cable and mating products. Check the probe threads by hand-threading the probe into the compression lug; replace any damaged components if resistance is encountered.

  2. Prepare Cable for Termination

    Train the cable to ensure adequate slack for operation. Prepare the cable end according to its type (non-jacketed, jacketed concentric neutral, jacketed with drain wires, or jacketed copper tape shield) by removing the outer jacket and/or shield to the specified lengths (e.g., 9-5/8 inches for jacketed cables). Unwrap and bind neutral or drain wires as required. Remove 2-1/8 inches (55mm) of shield and insulation from the cable end, cutting squarely without nicking the conductor. Bevel the insulation end a maximum of 1/8 inch (5mm). Thoroughly clean the insulation to remove all dirt or excess inhibitor.

  3. Install Compression Lug

    Wire brush bare aluminum conductors immediately before installation. Install the compression lug, rotating it to spread inhibitor. Position the compression lug so its contact threaded hole aligns with the bushing bore. Refer to the crimp chart supplied with the lug for recommended crimp tool information. Start crimping at the crimp line mark, rotating 180 degrees for each successive crimp. Carefully wipe any excess inhibitor from the outside of the lug and cable.

  4. Assemble Elbow Connector

    Lubricate the cable insulation and the inside of the elbow housing with the supplied lubricant; DO NOT SUBSTITUTE. Slide the elbow connector onto the cable using a back-and-forth twisting motion. Wipe off all excess lubricant. Align the elbow with the compression lug's threaded hole. Thread the probe into the lug by hand, ensuring it turns freely for approximately four turns before becoming snug. Tighten the probe with a wrench until the wrench bends.

  5. Ground the Elbow and Neutral Wires

    Insert one end of a separate copper wire (No. 14 AWG / 2.5mm) or equivalent through the grounding eye on the elbow. Twist it tightly, taking care not to damage the eye. Twist all neutral wires together and connect them to ground using an appropriate connector. Ensure adequate slack in the wires for elbow operation. If using a cold shrink grounding kit, refer to its specific instructions.

  6. Connect Elbow to Bushing Plug

    DANGER: CONFIRM THAT THE TRANSFORMER AND ELBOW ARE DE-ENERGIZED before proceeding. Lubricate the receptacle portion of the elbow connector and the mating bushing with the supplied lubricant. Operate the connection using a full insulated hotstick type tool; DO NOT OPERATE BY HAND. Securely fasten the hotstick to the loadbreak connector pulling eye. Insert the probe tip approximately 2 inches (50mm) into the bushing, then immediately push the elbow home with a fast, firm, straight motion, using sufficient force to engage the internal lock.

Frequently Asked Questions about ABB - Installation Products

How are Thomas and Betts products typically installed?

Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.

What accessories are available for Thomas and Betts products?

Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.

What environmental ratings do Thomas and Betts products have?

Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.

What communication protocols do Thomas and Betts products support?

Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.

What are the key features of Thomas and Betts products?

Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.

What are the main product lines offered by Thomas and Betts?

Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.

What technical support does Thomas and Betts offer?

Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.

What industries and applications are Thomas and Betts products used for?

Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.

What certifications and standards do Thomas and Betts products comply with?

Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.

What are the main product lines offered by Ocal?

Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.