ABB Installation Products 167LRT-F5240 200 Amp, 15kV, Loadbreak Bolted Elbow with Tap, Cable Insulation Diameter 0.640 inch to…
UPC: 783786560523
Contact for Pricing
Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.
Overview
- 200 Amp current rating
- 15 kV voltage rating
- Bi-metal compression lug for superior conductivity
- Accommodates cable insulation diameters from 0.640" to 0.820"
- Suitable for AWG 1/0 Stranded / 2/0 Solid conductors (53.49 mm²)
Specifications
Amperage Rating | 200 A |
Application | 15kV, 200 Amps |
Color | Black |
Conductor Range | 1/0 STR/COMPR AWG , 2/0 SOL/COMPT AWG |
Environmental Conditions | Fully Submersible |
Insulation | True |
Material | Housing - EPDM-Rubber |
Size | Cable Insulation Diameter 0.640 inch to 0.820 inch |
Special Features | Includes 02800X Bi-Metal Contact |
Standard | ANSI/IEEE Standard 386 |
Temperature Rating, Maximum | 149 F |
Temperature Rating, Maximum | 65 C |
Temperature Rating, Minimum | -40 F |
Temperature Rating, Minimum | -40 C |
Type | Loadbreak Bolted Elbow with Tap |
Voltage Rating | 15 kV |
Package Dimensions (L x W x H) | 0.01 IN x 0.01 IN x 0.01 IN |
Package Dimensions (L x W x H) | 0.0254 cm x 0.0254 cm x 0.0254 cm |
Package Weight (Imperial) | 1.0000 L |
Package Weight (Metric) | 0.4540 kg |

252LR-C5240
25 kV, 200 Amp, Deadbreak, Elbow Connector with Test Point, Cable Insulation Diameter - .805-1.060 inch Bi-Metal Lug, Conductor Size 240 - 1/0 Stranded/Compressed or 2/0 Compact/Solid. Includes Elbow Connector Housing, Compression Lug, Probe, Probe Wrench, Bail Assembly, Tube of Lubricant, Installation Instructions, Crimp Chart and V.D. Cap-Peroxide.
K151SP-B0230
15/25kV 200 Amp, Deadbreak Straight Plug, Bails are required, but not included, order separately. Cable Insulation Diameter 0.635 inch to 0.905 inch. Aluminum Compression Lug. Conductor Size AWG Compressed Stranded #1/Solid 1/0 /mmSquared 42.41.
167RLR-F-5230
200 Amp, 15kV, Loadbreak Replacement Elbow Connector without Test Point, Cable Insulation Diameter 0.640 inch to 0.820 inch. Bi-Metal Compression Lug, Conductor Size AWG Compressed Stranded #1/Solid 1/0 /mmSquared 42.41. Repair Elbow has extended length contact and elbow housing resulting in a net gain of 8-7/8 inches in length. Includes 00400X long Bi-Metal Contact.
167RLR-H-5230
15kV 200 Amp, Loadbreak Replacement Elbow Connector, Repair Elbow has extended length contact and elbow housing resulting in a net gain of 8-7/8 inches in length. Bi-Metal Contact. Cable Insulation Diameter 0.850 inch to 1.050 inch. Conductor Size AWG Compressed Stranded #1/Solid 1/0 /mmSquared 42.41.
167RLR-J-5270
200 Amp, 15kV, Loadbreak Replacement Elbow Connector without Test Point, Cable Insulation Diameter 0.980 inch to 1.180 inch. Bi-Metal Compression Lug, Conductor Size AWG Compressed Stranded 4/0 /Solid 250 /mmSquared 126.67. Repair Elbow has extended length contact and elbow housing resulting in a net gain of 8-7/8 inches in length. Includes 00400X long Bi-Metal Contact.
273RLR-G-5220
25kV 200 Amp, Loadbreak Replacement Elbow Connector, Cable Insulation Diameter 0.760 inch to 0.950 inch. Bi-Metal Compression Lug. Conductor Size AWG Compressed Stranded #2/Solid #1/mmSquared 33.62.
167LRT-H-5270
15kV 200 Amp, Loadbreak Bolted Elbow with Tap. Cable Insulation Diameter 0.850 inch to 1.050 inch. Bi-Metal Compression Lug. Conductor Size AWG Compressed Stranded 4/0 /Solid 250 /mmSquared 126.67.
167RLR-F-5240
200 Amp, 15kV, Loadbreak Replacement Elbow Connector without Test Point, Cable Insulation Diameter 0.640 inch to 0.820 inch. Bi-Metal Compression Lug, Conductor Size AWG Compressed Stranded 1/0 /Solid 2/0 /mmSquared 53.49. Repair Elbow has extended length contact and elbow housing resulting in a net gain of 8-7/8 inches in length. Includes 00400X long Bi-Metal Contact.Frequently Asked Questions
What is the Impulse Withstand (BIL) rating?
The Impulse Withstand (BIL) rating is 95kV, based on a 1.2 x 50 microsecond wave.
What safety precaution is needed for the tap point?
The loadbreak-rated tap point must be covered with an insulated cap when it is not in use.
Is an installation tool provided with the product?
Yes, the 167LRT is installed using the installation tool supplied within the product kit.
What items are included in the 167LRT kit?
The kit contains the elbow connector housing, compression lug, stud extender, lubricant, installation tool, wrench, installation instructions, and a crimp chart.
What bushing wells are compatible with 167LRT?
The 167LRT mates with bushing wells that conform to ANSI Std. 386, Fig. 3.
What industry standards does the product meet?
The product conforms to ANSI/IEEE Standard 386, specifically Fig. 5.
What is the maximum operating voltage?
The maximum phase-to-ground operating voltage is 8.3 kV, and the maximum phase-to-phase voltage is 14.4 kV.
What are the main voltage and current ratings?
It is rated for 15kV voltage class and 200 Amp continuous and loadbreak current.
What is the 167LRT product type?
The 167LRT is a loadbreak elbow connector with a loadbreak tap, rated as a 200 Amp, 15kV deadbreak connector.
What is the 167LRT product type?
The 167LRT is a loadbreak elbow connector with a loadbreak tap, rated as a 200 Amp, 15kV deadbreak connector.
How to Install the 167LRT Loadbreak Bushing Tap
This guide provides step-by-step instructions for the safe and proper installation of the Elastimold 167LRT Loadbreak Bushing Tap, including cable preparation, assembly, and connection.
Estimated time: 1h
Tools needed:
Wrenches, Installation Tool, Wire brush, Crimp tool
Supplies needed:
Lubricant (Do Not Substitute), No. 14 AWG (2.5mm) copper wire or equivalent, Appropriate ground connector, HV insulated cap(s) or connector(s) (if replacing shipping covers), Mating products (e.g., Loadbreak Elbow, Insulated Cap, Grounding Elbow Connector)
- De-energize and Inspect Apparatus
DANGER: Ensure all apparatus is de-energized before beginning installation or removal of parts. Inspect all package contents and components for completeness, damage, proper rating, and compatibility with the cable and mating products. If the product is supplied with protective shipping cover(s), remove them and replace with appropriate HV insulated cap(s) or connector(s) before submerging or energizing the circuit.
- Train Cable
Train the cable as shown in the diagram to ease future operation. Cut excess cable squarely at the center line of the bushing, ensuring a minimum of 20 inches beyond the end of the cable.
- Prepare Cable
Unwrap and bind concentric neutral wires 8-1/2 inches back from the end of the cable. Remove the shield and insulation from the cable end, cutting squarely and taking care not to nick the conductor. Wire brush bare aluminum conductors and immediately install the compression lug, rotating to spread inhibitor. Position the compression lug so its contact threaded hole aligns with the bushing bore. Crimp the lug according to the crimp chart packaged with the compression lug, starting at the crimp line mark and rotating 180 degrees for each successive crimp. Carefully wipe excessive inhibitor from the outside of the lug and cable. Remove the semi-con shield as shown and bevel the insulation end 1/8 inch maximum. Thoroughly clean the insulation to remove all traces of conductive residue.
- Assemble Bushing Well Contact
Thread the well contact onto the bushing well stud by hand, taking care not to cross-thread. Tighten with the supplied wrench until the wrench bends, signifying proper torque.
- Assemble Bushing Tap
Remove the protective cap from the bushing tap and remove the socket contact stored inside the bushing tap housing. Lubricate the cable insulation and the inside of the bushing housing with the supplied lubricant; DO NOT SUBSTITUTE. Keep insulation clean of dirt and grime. Do not use excess grease and do not introduce any grease into the gap between the lug and the insulation. Slide the bushing tap onto the cable with a back and forth twisting motion and wipe off all excess grease. Align the bushing with the compression lug hole and assemble the socket contact into the bushing tap, ensuring the socket contact stud passes through the lug hole.
- Lubricate and Mount Bushing Tap
Inspect the apparatus bushing well to ensure it is dry and free from all contaminants. Lubricate the bushing well interface area of the bushing tap with the supplied lubricant or ELASTIMOLD approved lubricants. Place the lubricated portion of the bushing tap into the apparatus bushing well. Insert the installation tool into the bore of the bushing tap until fully seated. Insert the wrench through the wrench hole of the tool and turn in a clockwise direction until the wrench bends, signifying the proper assembly torque has been reached. Remove the wrench and installation tool from the bushing tap, cleaning the tool before re-insertion.
- Connect Concentric Neutral
Insert one end of a No. 14 AWG (2.5mm) copper wire or equivalent through the grounding eye on the bushing tap. Twist it tight, taking care not to damage the eye. Twist the neutral wires and connect them to ground using an appropriate connector.
- Final Lubrication and Mating Product Installation
Thoroughly wipe the bushing tap interface clean of any contaminants and apply a light, uniform coat of supplied lubricant, working it thoroughly into the surface. CAUTION: EXCESS LUBRICANT may prevent a loadbreak elbow from being fully seated in the 'locked on' position. Install the mating products to the bushing tap following the instructions supplied with the mating products. If the bushing tap is not to be immediately mated with an elbow connector, insulated cap or grounding elbow connector, replace the shipping cap. Do not energize or submerge the apparatus with the shipping cap on the bushing tap, as it is a protective cap only and is not insulated or watertight.
Frequently Asked Questions about ABB - Installation Products
How are Thomas and Betts products typically installed?
Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.
What accessories are available for Thomas and Betts products?
Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.
What environmental ratings do Thomas and Betts products have?
Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.
What communication protocols do Thomas and Betts products support?
Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.
What are the key features of Thomas and Betts products?
Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.
What are the main product lines offered by Thomas and Betts?
Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.
What technical support does Thomas and Betts offer?
Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.
What industries and applications are Thomas and Betts products used for?
Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.
What certifications and standards do Thomas and Betts products comply with?
Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.
What are the main product lines offered by Ocal?
Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.