
ABB Installation Products 167LRT-H-5270 15kV 200 Amp, Loadbreak Bolted Elbow with Tap. Cable Insulation Diameter 0.850 inch to…
UPC: 783786624140
Contact for Pricing
Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.
Overview
- 15kV voltage rating
- 200 Amp continuous current rating
- Accommodates 0.850" to 1.050" cable insulation diameter
- Bi-metal compression lug for conductor connection
- Suitable for 4/0 AWG compressed stranded or 250 AWG solid conductors
Specifications
Amperage Rating | 200 A |
Application | 15kV, 200 Amps |
Color | Black |
Conductor Range | 4/0 STR/COMPR AWG , 250 kcmil |
Environmental Conditions | Fully Submersible |
Insulation | True |
Material | Housing - EPDM-Rubber |
Size | Cable Insulation Diameter 0.850 inch to 1.050 inch |
Special Features | Includes 02800X Bi-Metal Contact |
Standard | ANSI/IEEE Standard 386 |
Temperature Rating, Maximum | 149 F |
Temperature Rating, Maximum | 65 C |
Temperature Rating, Minimum | -40 F |
Temperature Rating, Minimum | -40 C |
Type | Loadbreak Bolted Elbow with Tap |
Voltage Rating | 15 kV |
Package Dimensions (L x W x H) | 0.01 IN x 0.01 IN x 0.01 IN |
Package Dimensions (L x W x H) | 0.0254 cm x 0.0254 cm x 0.0254 cm |
Package Weight (Imperial) | 3.0000 L |
Package Weight (Metric) | 1.3610 kg |

162LR-D5270-S
200 Amp, 15kV, Loadbreak Elbow Connector, Cable Insulation Diameter 0.890 inch to 1.220 inch. Bi-Metal Compression Lug. Conductor Size AWG Compressed Stranded 4/0 /Solid 250 /mmSquared 126.67. 200ECS Jacket Seal Included.
167RLR-F-5240
200 Amp, 15kV, Loadbreak Replacement Elbow Connector without Test Point, Cable Insulation Diameter 0.640 inch to 0.820 inch. Bi-Metal Compression Lug, Conductor Size AWG Compressed Stranded 1/0 /Solid 2/0 /mmSquared 53.49. Repair Elbow has extended length contact and elbow housing resulting in a net gain of 8-7/8 inches in length. Includes 00400X long Bi-Metal Contact.
168RLR-G-5240
15kV 200 Amp, Loadbreak Replacement Elbow Connector with Test Point. Cable Insulation Diameter 0.760 inch to 0.950 inch. Bi-Metal Compression Lug. Conductor Size AWG Compressed Stranded 1/0 /Solid 2/0 /mmSquared 53.49.
K151SP-GAB10AX
Straight Plug, 200 Amp, DeadBreak, 15/25KV, Cable Insulation Diameter 0.825 inch to 0.935 inch.
168RLR-F-5220
15kV 200 Amp, Loadbreak Replacement Elbow Connector with Test Point. Cable Insulation Diameter 0.640 inch to 0.820 inch. Bi-Metal Compression Lug. Conductor Size AWG Compressed Stranded #2/Solid #1/mmSquared 33.62.
167LRT-F5220
15kV 200 Amp, Loadbreak Bolted Elbow with Tap. Cable Insulation Diameter 0.640 inch to 0.820 inch. Bi-Metal Compression Lug. Conductor Size AWG Compressed Stranded #2/Solid #1/mmSquared 33.62.
274RLR-H-5240
25kV 200 Amp, Loadbreak Replacement Elbow Connector with Test Point. Cable Insulation Diameter 0.850 inch to 1.050 inch. Bi-Metal Compression Lug. Conductor Size AWG Compressed Stranded 1/0 /Solid 2/0 /mmSquared 53.49.
167RLR-G-5240
15kV 200 Amp, Loadbreak Replacement Elbow Connector, Repair Elbow has extended length contact and elbow housing resulting in a net gain of 8-7/8 inches in length. Bi-Metal Contact. Cable Insulation Diameter 0.760 inch to 0.950 inch. Conductor Size AWG Compressed Stranded 1/0 /Solid 2/0 /mmSquared 53.49.Frequently Asked Questions
What tool is needed for installation?
The 167LRT is installed using the installation tool supplied within the product kit.
What are the primary applications of the 167LRT?
The 167LRT is designed for connecting to and operating 15kV-class, 95BIL distribution apparatus.
What is the momentary and fault close rating?
The momentary and fault close rating is 10kA Symmetrical for 10 cycles.
What functions does the loadbreak interface provide?
The loadbreak operating interface provides functions for phasing, grounding, testing, or arrester protection.
What standards does the elbow conform to?
The elbow conforms to ANSI Std. 386, Fig. 5 and mates with bushing wells conforming to ANSI Std. 386, Fig. 3.
What is the 15-minute DC withstand voltage?
The 15-minute DC withstand voltage is 53kV.
What is the corona extinction voltage?
The corona extinction voltage is 11kV AC at 3pC sensitivity.
What is the one-minute AC withstand voltage?
The one-minute AC withstand voltage is 34kV.
What is the Basic Impulse Level (BIL)?
The Basic Impulse Level (BIL) is 95kV impulse withstand (1.2 x 50 microsecond wave).
What is the maximum phase-to-phase voltage?
The maximum phase-to-phase voltage is 14.4 kV.
How to Install the 167LRT Loadbreak Bushing Tap
This guide provides step-by-step instructions for the safe and proper installation of the Elastimold 167LRT Loadbreak Bushing Tap, designed for terminating UD cable and interfacing with 15kV class loadbreak elbows or accessories.
Estimated time: 3h
Tools needed:
Wrenches, Crimp tool, Wire brush, Installation tool
Supplies needed:
Lubricant (Do Not Substitute), UD cable (concentric neutral and semi-con shielding), No. 14 AWG (2.5mm) copper wire, Grounding connector, Mating loadbreak elbow or accessory, Insulated cap or grounding elbow connector
- Prepare for Installation and Ensure Safety
De-energize all apparatus before beginning installation. Inspect all parts for damage, rating, and compatibility. Confirm installation is performed by competent, trained personnel. Gather all required tools and supplies, ensuring cleanliness throughout the procedure. If the product is supplied with protective shipping covers, remove them and replace with appropriate HV insulated caps or connectors before submerging or energizing the circuit.
- Prepare the Cable
Train the UD cable to ease operation, ensuring a minimum of 20 inches beyond the end of the cable pad mount transformer. Cut the excess cable squarely at the center line of the bushing. Unwrap and bind concentric neutral wires 8-1/2 inches back from the cable end. Remove the shield and insulation from the cable end, cutting squarely without nicking the conductor. Wire brush bare aluminum conductors and immediately install the compression lug, rotating to spread inhibitor. Align the compression lug's contact threaded hole with the bushing bore. Crimp the lug according to the crimp chart, starting at the crimp line mark and rotating 180 degrees for each successive crimp. Wipe excessive inhibitor from the outside of the lug and cable. Remove the semi-con shield as shown in the template and bevel the insulation end a maximum of 1/8 inch. Thoroughly clean the insulation to remove all traces of conductive residue.
- Assemble the Bushing Well Contact
Thread the well contact onto the bushing well stud by hand, taking care not to cross-thread. Tighten the well contact with a wrench until the wrench bends, which signifies the proper assembly torque has been reached.
- Assemble the Bushing Tap
Remove the protective cap from the bushing tap and retrieve the socket contact stored inside the bushing tap housing. Lubricate the cable insulation and the inside of the bushing housing with the supplied lubricant ONLY; do not substitute. Keep insulation clean and avoid introducing excess grease into the gap between the lug and insulation. Slide the bushing tap onto the cable using a back-and-forth twisting motion, then wipe off all excess grease. Align the bushing with the compression lug hole and assemble the socket contact into the bushing tap, ensuring the socket contact stud passes through the lug hole.
- Mount the Bushing Tap
Inspect the apparatus bushing well to ensure it is dry and free from all contaminants. Lubricate the bushing well interface area of the bushing tap with the supplied lubricant or ELASTIMOLD approved lubricants. Place the lubricated portion of the bushing tap into the apparatus bushing well. Insert the installation tool into the bore of the bushing tap until fully seated. Insert a wrench through the wrench hole of the tool and turn in a clockwise direction until the wrench bends, signifying the proper assembly torque has been reached. Remove the wrench and installation tool from the bushing tap.
- Connect the Concentric Neutral
Insert one end of a No. 14 AWG (2.5mm) copper wire or equivalent through the grounding eye on the bushing tap. Twist the wire tight, taking care not to damage the eye. Twist the neutral wires and connect them to ground using an appropriate connector.
- Finalize and Mate the Bushing Tap
Thoroughly wipe the bushing tap interface clean of any contaminants. Apply a light, uniform coat of the supplied lubricant to the interface, working it thoroughly into the surface. CAUTION: Excess lubricant may prevent a loadbreak elbow from being fully seated in the “locked on” position. Install the mating loadbreak elbow or accessory device to the bushing tap, following the instructions supplied with the mating products. If the bushing tap is not to be immediately mated, replace the shipping cap. Do not energize or submerge the apparatus with the shipping cap, as it is a protective cap only and is not insulated or watertight.
Frequently Asked Questions about ABB - Installation Products
How are Thomas and Betts products typically installed?
Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.
What accessories are available for Thomas and Betts products?
Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.
What environmental ratings do Thomas and Betts products have?
Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.
What communication protocols do Thomas and Betts products support?
Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.
What are the key features of Thomas and Betts products?
Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.
What are the main product lines offered by Thomas and Betts?
Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.
What technical support does Thomas and Betts offer?
Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.
What industries and applications are Thomas and Betts products used for?
Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.
What certifications and standards do Thomas and Betts products comply with?
Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.
What are the main product lines offered by Ocal?
Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.