ABB Installation Products 167RLR-H-5230 15kV 200 Amp, Loadbreak Replacement Elbow Connector, Repair Elbow has extended length…
UPC: 783786620678
Contact for Pricing
Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.
Overview
- 15kV voltage rating
- 200 Amp current rating
- Extended length contact and housing (+8-7/8 inches)
- Bi-metal contact for enhanced conductivity
- Accommodates cable insulation diameter 0.850" - 1.050"
Specifications
Amperage Rating | 200 A |
Application | Designed for connecting to and operating 15kV Class, 95kV BIL apparatus |
Color | Black |
Conductor Range | #1 STR/COMPR AWG , 1/0 SOL/COMPT AWG |
Connection Type | Loadbreak Replacement Elbow Connector |
Current Rating | 200 A |
Environmental Conditions | Fully Submersible |
Insulation | True |
Material | Housing - EPDM-Rubber |
Material | Bi-Metal |
Size | 0.850 inch to 1.050 inch |
Size | Cable Insulation Diameter 0.850 inch to 1.050 inch |
Special Features | Fully shielded, fully submersible molded rubber housing. 100 percent peroxide-cured insulation, insert and jacket. Provision for hot stick operation, Provision for ground wire connection. Wide cable range with minimum number of sizes. Extended length housing and compression lug plus 10-1/2 inch (266.7mm) |
Standard | ANSI/IEEE Standard 386 |
Temperature Rating, Maximum | 149 F |
Temperature Rating, Maximum | 65 C |
Temperature Rating, Minimum | -40 F |
Temperature Rating, Minimum | -40 C |
Type | Loadbreak Replacement Elbow Connector |
Voltage Rating | 15 kV |
Package Dimensions (L x W x H) | 0.01 IN x 0.01 IN x 0.01 IN |
Package Dimensions (L x W x H) | 0.0254 cm x 0.0254 cm x 0.0254 cm |
Package Weight (Imperial) | 4.2800 L |
Package Weight (Metric) | 1.9410 kg |

167RLR-G-5230
15kV 200 Amp, Loadbreak Replacement Elbow Connector, Repair Elbow has extended length contact and elbow housing resulting in a net gain of 8-7/8 inches in length. Bi-Metal Contact. Cable Insulation Diameter 0.760 inch to 0.950 inch. Conductor Size AWG Compressed Stranded #1/Solid 1/0 /mmSquared 42.41.
167RLR-J-5270
200 Amp, 15kV, Loadbreak Replacement Elbow Connector without Test Point, Cable Insulation Diameter 0.980 inch to 1.180 inch. Bi-Metal Compression Lug, Conductor Size AWG Compressed Stranded 4/0 /Solid 250 /mmSquared 126.67. Repair Elbow has extended length contact and elbow housing resulting in a net gain of 8-7/8 inches in length. Includes 00400X long Bi-Metal Contact.
273RLR-G-5220
25kV 200 Amp, Loadbreak Replacement Elbow Connector, Cable Insulation Diameter 0.760 inch to 0.950 inch. Bi-Metal Compression Lug. Conductor Size AWG Compressed Stranded #2/Solid #1/mmSquared 33.62.
167LRT-H-5270
15kV 200 Amp, Loadbreak Bolted Elbow with Tap. Cable Insulation Diameter 0.850 inch to 1.050 inch. Bi-Metal Compression Lug. Conductor Size AWG Compressed Stranded 4/0 /Solid 250 /mmSquared 126.67.
167RLR-F-5240
200 Amp, 15kV, Loadbreak Replacement Elbow Connector without Test Point, Cable Insulation Diameter 0.640 inch to 0.820 inch. Bi-Metal Compression Lug, Conductor Size AWG Compressed Stranded 1/0 /Solid 2/0 /mmSquared 53.49. Repair Elbow has extended length contact and elbow housing resulting in a net gain of 8-7/8 inches in length. Includes 00400X long Bi-Metal Contact.
168RLR-G-5240
15kV 200 Amp, Loadbreak Replacement Elbow Connector with Test Point. Cable Insulation Diameter 0.760 inch to 0.950 inch. Bi-Metal Compression Lug. Conductor Size AWG Compressed Stranded 1/0 /Solid 2/0 /mmSquared 53.49.
K151SP-GAB10AX
Straight Plug, 200 Amp, DeadBreak, 15/25KV, Cable Insulation Diameter 0.825 inch to 0.935 inch.Frequently Asked Questions
What contact is included with the 167RLR replacement elbow?
The 167RLR replacement elbow includes a long bi-metal contact, catalog number 00400X.
How much longer is the 167RLR replacement elbow?
The 167RLR replacement elbow provides a net gain of 8 7/8 inches in length compared to a standard elbow.
What cable insulation diameters does the 167RLR accommodate?
The 167RLR accommodates cable insulation diameters ranging from 0.640 inches to 1.310 inches, depending on the specific symbol (F, G, H, J, K).
What conductor sizes are compatible with the 167RLR?
The 167RLR is compatible with conductor sizes from #2 AWG to 250 kcmil.
What standards does the Elastimold elbow comply with?
The Elastimold 200 A loadbreak repair and replacement elbows are IEEE 386 compliant, ANSI certified, and Rural Utilities Service (RUS) accepted.
Where are these Elastimold elbows manufactured?
Elastimold 200 A repair and replacement elbows are designed, molded, and tested in Albuquerque, New Mexico, USA.
What is the voltage class for the 167RLR replacement elbow?
The 167RLR replacement elbow connector is designed for a 15 kV voltage class.
What is the current rating of these elbow connectors?
These elbow connectors are rated for 200 A loadbreak applications.
What conductor sizes are compatible with the 167RLR?
The 167RLR is compatible with conductor sizes from #2 AWG to 250 kcmil.
What contact is included with the 167RLR replacement elbow?
The 167RLR replacement elbow includes a long bi-metal contact, catalog number 00400X.
How to Install 167RLR/168RLR Loadbreak Replacement Elbow Connectors
This guide provides step-by-step instructions for the safe installation of Elastimold 167RLR and 168RLR Loadbreak Replacement Elbow Connectors, converting livefront terminations to deadfront for UD cable.
Estimated time: 1h 30m
Tools needed:
Probe Wrench, Wire brush, Crimping tool, Wire strippers/cable cutting tool, Hotstick
Supplies needed:
167RLR/168RLR Replacement Elbow Connector Housing, Compression Lug, Probe, Lubricant (supplied), Hose Clamp, No. 14 AWG (2.5mm) copper wire
- De-energize and Prepare for Installation
Ensure all apparatus is de-energized before beginning installation or removal of any parts. Read the entire installation instructions, check all package contents for completeness and damage, and verify component compatibility with the cable and mating products. Have all required tools ready and maintain cleanliness throughout the procedure. DANGER: All apparatus must be de-energized during installation or removal of part(s).
- Remove Existing Livefront Termination
Carefully remove the rubber cap from the existing terminator. Cut off the connector at the top of the terminator and disconnect the ground lead from its base. Finally, remove the terminator housing from the cable.
- Prepare the Cable
Train the cable to be straight and in-line with the bushing centerline. Measure and cut the cable to 10-1/2 inches from the bushing centerline. Verify the insulation shield measures less than 6-1/2 inches from the end of the cut cable. Remove 1-3/8 inches of cable insulation from the end, ensuring the cut is square and the conductor is not nicked.
- Install the Compression Lug
Wire brush the bare aluminum conductor immediately after preparation. Install the compression lug, rotating it to spread the inhibitor. Align the lug's threaded hole with the bushing bore. Crimp the lug according to the crimp chart provided, starting at the crimp line mark and rotating 180 degrees for each successive crimp. Carefully wipe off any excessive inhibitor from the lug and cable.
- Assemble the Elbow Housing
Lubricate the cable insulation and the inside of the elbow housing with the supplied lubricant; do not substitute. Slide the elbow connector onto the cable using a back-and-forth twisting motion, then wipe off all excess grease. Align the elbow with the compression lug’s threaded hole. Thread the probe into the lug by hand, ensuring it turns freely for approximately four turns before becoming snug. Tighten the probe with the supplied wrench until the wrench bends.
- Connect the Concentric Neutral
Insert one end of a No. 14 AWG (2.5mm) copper wire or equivalent through the grounding eye on the elbow and twist it tight, taking care not to damage the eye. Twist all neutral wires together and connect them to ground using an appropriate connector, ensuring adequate slack is provided for elbow operation. Add the supplied hose clamp as shown in the diagram and tighten it snugly, but do not overtighten.
- Connect Elbow to Bushing Plug
Lubricate the receptacle portion of the elbow connector and the mating bushing with the supplied lubricant. This lubrication must only be performed if the transformer and elbow are known to be de-energized. Once lubricated, the elbow can be connected to the bushing following the loadmake operating instructions, using a full insulated 'hotstick' type live-line tool. Do not operate by hand. DANGER: Lubricate only if known to be de-energized. DO NOT OPERATE BY HAND.
Frequently Asked Questions about ABB - Installation Products
How are Thomas and Betts products typically installed?
Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.
What accessories are available for Thomas and Betts products?
Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.
What environmental ratings do Thomas and Betts products have?
Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.
What communication protocols do Thomas and Betts products support?
Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.
What are the key features of Thomas and Betts products?
Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.
What are the main product lines offered by Thomas and Betts?
Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.
What technical support does Thomas and Betts offer?
Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.
What industries and applications are Thomas and Betts products used for?
Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.
What certifications and standards do Thomas and Betts products comply with?
Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.
What are the main product lines offered by Ocal?
Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.