ABB - Installation Products 167RLR-F-5240 - 200 Amp, 15kV, Loadbreak Replacement Elbow Connector without Test Point, Cable Insulation Diameter 0.640 inch to 0.820 inch. Bi-Metal Compression Lug, Conductor Size AWG Compressed Stranded 1/0 /Solid 2/0 /mmSquared 53.49. Repair Elbow has extended length contact and elbow housing resulting in a net gain of 8-7/8 inches in length. Includes 00400X long Bi-Metal Contact.

ABB Installation Products 167RLR-F-5240 200 Amp, 15kV, Loadbreak Replacement Elbow Connector without Test Point, Cable…

UPC: 783786630523


Documents & Media
BrochureInstallation InstructionsSpecification SheetManufacturer Product Website

Contact for Pricing

Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.

Overview

The ABB 167RLR-F-5240 is a 200 Amp, 15kV loadbreak replacement elbow connector designed for medium-voltage cable systems requiring safe, reliable loadbreak operations. This elbow connector accommodates cable insulation diameters from 0.640 inch to 0.820 inch and supports conductor sizes ranging from 1/0 to 2/0 AWG compressed stranded or solid, as well as 53.49 mm². The unit features a bi-metal compression lug for secure conductor termination and includes the 00400X long bi-metal contact for extended electrical contact area. A key advantage of the 167RLR-F-5240 is its extended length contact and elbow housing, which provides an additional 8-7/8 inches in overall length. This design improves installation flexibility in tight spaces and enhances mechanical durability during repeated loadbreak operations. The elbow does not include a test point, making it suitable for applications where test point access is not required or where space constraints prevent its use.
  • Rated 200 Amps at 15kV for medium-voltage loadbreak applications
  • Accommodates cable insulation diameters from 0.640 inch to 0.820 inch
  • Supports conductor sizes: 1/0 to 2/0 AWG (compressed stranded or solid) and 53.49 mm²
  • Bi-metal compression lug with 00400X long bi-metal contact for secure termination
  • Extended length design adds 8-7/8 inches for improved installation flexibility

Specifications

Amperage Rating
200 A
Application
Designed for connecting to and operating 15kV Class, 95kV BIL apparatus
Color
Black
Conductor Range
1/0 STR/COMPR AWG , 2/0 SOL/COMPT AWG
Connection Type
Compression Lug
Current Rating
200 A
Environmental Conditions
Fully Submersible
Insulation
True
Material
Housing - EPDM-Rubber
Material
Bi-Metal Compression Lug
Series
167RLR-F
Size
Cable Insulation Diameter 0.640 inch to 0.820 inch
Special Features
Fully shielded, fully submersible molded rubber housing. 100 percent peroxide-cured insulation, insert and jacket. Provision for hot stick operation, Provision for ground wire connection. Wide cable range with minimum number of sizes. Extended length housing and compression lug plus 10-1/2 inch (266.7mm)
Standard
ANSI/IEEE Standard 386
Temperature Rating, Maximum
149 F
Temperature Rating, Maximum
65 C
Temperature Rating, Minimum
-40 F
Temperature Rating, Minimum
-40 C
Type
Loadbreak Replacement Elbow Connector
Voltage Rating
15 kV
Package Dimensions (L x W x H)
0.01 IN x 0.01 IN x 0.01 IN
Package Dimensions (L x W x H)
0.0254 cm x 0.0254 cm x 0.0254 cm
Package Weight (Imperial)
4.2800 L
Package Weight (Metric)
1.9410 kg
600 Amp, 15-25kV, 600 Series Deadbreak Straight Receptacle. Cable Insulation Diameter 0.850 inch to 1.050 inch. Aluminum Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 1/0 /Compacted Solid 2/0. Cold Shrinkable Seal with Copper Braid and Constant Force Spring Included.

K655YSR-H0240-SG3

600 Amp, 15-25kV, 600 Series Deadbreak Straight Receptacle. Cable Insulation Diameter 0.850 inch to 1.050 inch. Aluminum Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 1/0 /Compacted Solid 2/0. Cold Shrinkable Seal with Copper Braid and Constant Force Spring Included.
15kV 200 Amp, Loadbreak Replacement Elbow Connector with Test Point. Cable Insulation Diameter 0.760 inch to 0.950 inch. Bi-Metal Compression Lug. Conductor Size AWG Compressed Stranded 1/0 /Solid 2/0 /mmSquared 53.49.

168RLR-G-5240

15kV 200 Amp, Loadbreak Replacement Elbow Connector with Test Point. Cable Insulation Diameter 0.760 inch to 0.950 inch. Bi-Metal Compression Lug. Conductor Size AWG Compressed Stranded 1/0 /Solid 2/0 /mmSquared 53.49.
Straight Plug, 200 Amp, DeadBreak, 15/25KV, Cable Insulation Diameter 0.825 inch to 0.935 inch.

K151SP-GAB10AX

Straight Plug, 200 Amp, DeadBreak, 15/25KV, Cable Insulation Diameter 0.825 inch to 0.935 inch.
15kV 200 Amp, Loadbreak Replacement Elbow Connector with Test Point. Cable Insulation Diameter 0.640 inch to 0.820 inch. Bi-Metal Compression Lug. Conductor Size AWG Compressed Stranded #2/Solid #1/mmSquared 33.62.

168RLR-F-5220

15kV 200 Amp, Loadbreak Replacement Elbow Connector with Test Point. Cable Insulation Diameter 0.640 inch to 0.820 inch. Bi-Metal Compression Lug. Conductor Size AWG Compressed Stranded #2/Solid #1/mmSquared 33.62.
15kV 200 Amp, Loadbreak Bolted Elbow with Tap. Cable Insulation Diameter 0.640 inch to 0.820 inch. Bi-Metal Compression Lug. Conductor Size AWG Compressed Stranded #2/Solid #1/mmSquared 33.62.

167LRT-F5220

15kV 200 Amp, Loadbreak Bolted Elbow with Tap. Cable Insulation Diameter 0.640 inch to 0.820 inch. Bi-Metal Compression Lug. Conductor Size AWG Compressed Stranded #2/Solid #1/mmSquared 33.62.
25kV 200 Amp, Loadbreak Replacement Elbow Connector with Test Point. Cable Insulation Diameter 0.850 inch to 1.050 inch. Bi-Metal Compression Lug. Conductor Size AWG Compressed Stranded 1/0 /Solid 2/0 /mmSquared 53.49.

274RLR-H-5240

25kV 200 Amp, Loadbreak Replacement Elbow Connector with Test Point. Cable Insulation Diameter 0.850 inch to 1.050 inch. Bi-Metal Compression Lug. Conductor Size AWG Compressed Stranded 1/0 /Solid 2/0 /mmSquared 53.49.
15kV 200 Amp, Loadbreak Replacement Elbow Connector, Repair Elbow has extended length contact and elbow housing resulting in a net gain of 8-7/8 inches in length. Bi-Metal Contact. Cable Insulation Diameter 0.760 inch to 0.950 inch. Conductor Size AWG Compressed Stranded 1/0 /Solid 2/0 /mmSquared 53.49.

167RLR-G-5240

15kV 200 Amp, Loadbreak Replacement Elbow Connector, Repair Elbow has extended length contact and elbow housing resulting in a net gain of 8-7/8 inches in length. Bi-Metal Contact. Cable Insulation Diameter 0.760 inch to 0.950 inch. Conductor Size AWG Compressed Stranded 1/0 /Solid 2/0 /mmSquared 53.49.
200 Amp, 15kV, Loadbreak Replacement Elbow Connector with Test Point, Cable Insulation Diameter 0.760 inch to 0.950 inch. Bi-Metal Compression Lug, Conductor Size AWG Compressed Stranded 2/0 /Solid 3/0 /mmSquared 67.43. Repair Elbow has extended length contact and elbow housing resulting in a net gain of 8-7/8 inches in length. Includes 00400X long Bi-Metal Contact.

168RLR-G-5250

200 Amp, 15kV, Loadbreak Replacement Elbow Connector with Test Point, Cable Insulation Diameter 0.760 inch to 0.950 inch. Bi-Metal Compression Lug, Conductor Size AWG Compressed Stranded 2/0 /Solid 3/0 /mmSquared 67.43. Repair Elbow has extended length contact and elbow housing resulting in a net gain of 8-7/8 inches in length. Includes 00400X long Bi-Metal Contact.

Frequently Asked Questions

What is the current rating of the elbow connectors?

The elbow connectors are rated for 200 A loadbreak applications.

What voltage classes do these connectors support?

The ABB Elastimold loadbreak repair and replacement elbows are available for 15 kV and 25 kV voltage classes.

How much length does the repair elbow add?

The repair elbow features an extended housing and compression lug length that is 3 1/4 inches longer than the standard elbow.

How much length does the replacement elbow add?

The replacement elbow extends its housing and compression lug length to 8 7/8 inches over the standard elbow.

What material are the elbows constructed from?

The elbows are constructed from specially formulated, non-rigid ethylene propylene diene monomer (EPDM) rubber.

Are these elbow connectors certified?

Yes, these connectors are IEEE 386 compliant, ANSI certified, and Rural Utilities Service (RUS) accepted.

Where are Elastimold elbows manufactured?

Elastimold 200 A repair and replacement elbows are designed, molded, and tested in Albuquerque, NM, USA.

What is the test point cap catalog number?

The test point cap catalog number for elbows with a test point is 156-7.

Where are these elbow connectors manufactured?

These Elastimold 200 A repair and replacement elbows are designed, molded, tested, and assembled in Albuquerque, New Mexico, USA.

What type of product are these connectors?

These are Elastimold 200 A loadbreak repair and replacement elbow connectors.

How to Install Elastimold 167RLR/168RLR Loadbreak Replacement Elbow Connectors

This guide provides step-by-step instructions for the safe installation and initial setup of Elastimold 167RLR (without Test Point) and 168RLR (with Test Point) Loadbreak Replacement Elbow Connectors, converting livefront terminations to deadfront for UD cable.

Estimated time: 1h 30m

Tools needed:

Probe Wrench, Wire brush, Crimp tool, Hotstick, Suitable sensing device (for 168RLR)

Supplies needed:

Replacement Elbow Connector Housing, Compression Lug, Probe, Lubricant (supplied, Do Not Substitute), Hose Clamp, Copper wire (No. 14 AWG / 2.5mm or equivalent), Silicone grease (for 168RLR test point cap)

  1. De-energize Apparatus and Perform Initial Checks

    Before starting, ensure all apparatus is de-energized. Verify the package contents are complete and undamaged. Check all components for proper fit with the cable and mating products. Thread the probe into the compression lug to check for resistance; replace damaged components if resistance is encountered. Read all instructions and gather required tools.

  2. Remove Existing Livefront Termination

    Remove the rubber cap from the existing terminator. Cut off the connector at the top of the terminator. Disconnect the ground lead from the base of the terminator. Finally, remove the terminator housing from the cable.

  3. Prepare the Cable

    Train the cable to be straight and in-line with the bushing centerline. Cut the cable to measure 10-1/2 inches from the bushing centerline. If the insulation shield measures less than 6-1/2 inches from the end of the cut cable, proceed. If it's greater, consult an ELASTIMOLD representative. Remove 1-3/8 inches of cable insulation from the end, ensuring not to nick the conductor.

  4. Install the Compression Lug

    Wire brush the bare aluminum conductor immediately. Install the compression lug, rotating it to spread the inhibitor. Align the compression lug so the contact threaded hole aligns with the bushing bore. Refer to the crimp chart supplied with the lug for crimping information. Start crimping at the crimp line mark, rotating 180 degrees for each successive crimp. Carefully wipe any excessive inhibitor from the outside of the lug and cable.

  5. Assemble the Elbow Housing

    Lubricate the cable insulation and the inside of the elbow housing with the supplied lubricant; do not substitute. Slide the elbow connector onto the cable using a back and forth twisting motion. Wipe off all excess grease. Align the elbow with the compression lug's threaded hole. Thread the probe into the lug by hand, ensuring it turns freely for approximately four turns before becoming snug. Tighten the probe with the wrench until the wrench bends.

  6. Connect the Concentric Neutral

    Insert one end of a separate copper wire (No. 14 AWG / 2.5mm or equivalent) through the grounding eye on the elbow and twist it tight, taking care not to damage the eye. Twist all neutral wires together and connect them to ground using an appropriate connector, providing adequate slack for elbow operation. Add the supplied hose clamp as shown in the diagram and tighten it snugly, but do not overtighten.

  7. Connect the Elbow to the Bushing Plug

    Lubricate the receptacle portion of the elbow connector and the mating bushing with the supplied lubricant. IMPORTANT: Only lubricate if the transformer and elbow are known to be de-energized. Securely fasten a hotstick to the loadbreak connector pulling eye. Place the elbow connector receptacle area over the bushing plug, inserting the elbow male contact into the bushing until slight resistance is felt. Immediately push the elbow home with a fast, firm, straight motion to engage the internal lock.

  8. Perform Voltage Test (168RLR ONLY)

    For 168RLR models, remove the test point cap with a hotstick, peeling it off at an angle. WARNING: The voltage test point is a capacitance device and not directly connected to the conductor. Do not use conventional voltage measuring equipment. Use a suitable sensing device designed for capacitive test points and follow its manufacturer's directions. Treat the elbow as energized until the 'no voltage' indication is confirmed by other means. After testing, clean and lubricate the inside surface of the cap with silicone grease and replace it tightly on the test point.

Frequently Asked Questions about ABB - Installation Products

How are Thomas and Betts products typically installed?

Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.

What accessories are available for Thomas and Betts products?

Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.

What environmental ratings do Thomas and Betts products have?

Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.

What communication protocols do Thomas and Betts products support?

Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.

What are the key features of Thomas and Betts products?

Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.

What are the main product lines offered by Thomas and Betts?

Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.

What technical support does Thomas and Betts offer?

Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.

What industries and applications are Thomas and Betts products used for?

Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.

What certifications and standards do Thomas and Betts products comply with?

Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.

What are the main product lines offered by Ocal?

Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.