The Panduit FCS29N-12-03P Opticom SC Splice Cassette is a preloaded fiber optic splicing solution designed for data centers, telecom networks, and enterprise environments. This cassette is factory-equipped with 12 OS2 discrete SC pigtails (250µm) and includes a splice kit, significantly reducing deployment time by eliminating manual pigtail installation. The SC connection type ensures broad compatibility with standard fiber optic systems. Constructed from durable polycarbonate, this cassette offers robust protection against environmental factors. It features a standard insertion loss (IL) and a removable bezel for convenient access during maintenance or reconfiguration. Designed for rackmount applications, the FCS29N-12-03P integrates seamlessly into standard 19-inch racks or cabinets. The OS2 fiber type supports high-speed data transmission with low attenuation, making it ideal for high-density fiber deployments. Technicians benefit from a simplified splicing process that minimizes errors and accelerates installation workflows. This product is part of the Opticom SC Splice Cassette series, known for its reliability and ease of use in fiber optic infrastructure projects.
  • Preloaded with 12 OS2 discrete SC pigtails (250µm)
  • Includes splice kit for simplified installation
  • Durable polycarbonate construction
  • Standard insertion loss (IL) with removable bezel
  • Rack-mountable design for 19-inch racks

Specifications

Package Dimensions (L x W x H)
9.2 IN x 4.5 IN x 2.6 IN
Package Dimensions (L x W x H)
23.368 cm x 11.43 cm x 6.604 cm
Package Weight (Imperial)
0.3000 L
Package Weight (Metric)
0.1361 kg
Opticom LC Splice Cassette is Preloaded with 24 OM4 Discrete Pigtails(250Um)and splice kit, and has Optimized IL. Cassettes have removable bevel.

FCS2ZO-24-LSP

Opticom LC Splice Cassette is Preloaded with 24 OM4 Discrete Pigtails(250Um)and splice kit, and has Optimized IL. Cassettes have removable bevel.
This Opticom LC/APC Splice Cassette is Preloaded with 24 OS2 Discrete Pigtails (250Um) and Splice Kit, and has Standard Il. Cassette has removable bevel

FCS29N-24-LAP

This Opticom LC/APC Splice Cassette is Preloaded with 24 OS2 Discrete Pigtails (250Um) and Splice Kit, and has Standard Il. Cassette has removable bevel
This Opticom SC Splice Cassette is Preloaded with 12 OM4 Discrete Pigtails (250Um) and Splice Kit, and has Opt Il. Cassettes have removable bevel

FCS2ZO-12-03P

This Opticom SC Splice Cassette is Preloaded with 12 OM4 Discrete Pigtails (250Um) and Splice Kit, and has Opt Il. Cassettes have removable bevel
This fiber splice holder accommodates and protects up to 24 fusion splices. This part comes with one rubber splice holder with an adhesive backing. This part is intended to be used with any Panduit Opticom Enclosure.

FSC6

This fiber splice holder accommodates and protects up to 24 fusion splices. This part comes with one rubber splice holder with an adhesive backing. This part is intended to be used with any Panduit Opticom Enclosure.
The Opticom Fiber Cassette is OM5, and features 1 MPO to 6 duplex LC and supports 12 fibers total. It is ultra low loss IL and uses Universal polarity. The cassette has a black cover with a black MPO connector and 6 lime LC adapters.

FC2WA-12-10U

The Opticom Fiber Cassette is OM5, and features 1 MPO to 6 duplex LC and supports 12 fibers total. It is ultra low loss IL and uses Universal polarity. The cassette has a black cover with a black MPO connector and 6 lime LC adapters.
The HD Flex 4-to-1 Breakout Cassette is OM5 MPO to LC and supports 8 fibers total. It is ultra low IL and uses Method A polarity. The 4-port cassette has a black cover with a black MPO connector and 4 lime duplex LC adapters with integral shutters to prevent contamination.

FHC3WA-08H-10A

The HD Flex 4-to-1 Breakout Cassette is OM5 MPO to LC and supports 8 fibers total. It is ultra low IL and uses Method A polarity. The 4-port cassette has a black cover with a black MPO connector and 4 lime duplex LC adapters with integral shutters to prevent contamination.
The HD Flex Cassette is OM5 MPO to LC and supports 12 fibers total. It is optimized IL and uses standard Method A polarity. The cassette has a black cover with a black MPO connector and 6 lime duplex LC adapters with integral shutters to prevent contamination.

FHCWO-12-10AS

The HD Flex Cassette is OM5 MPO to LC and supports 12 fibers total. It is optimized IL and uses standard Method A polarity. The cassette has a black cover with a black MPO connector and 6 lime duplex LC adapters with integral shutters to prevent contamination.
The HD Flex Cassette is OM5 MPO to LC and supports 12 fibers total. It is optimized IL and uses Modified Method A polarity with flipped pairs. The cassette has a black cover with a black MPO connector and 6 lime duplex LC adapters with integral shutters to prevent contamination.

FHCWO-12-10AF

The HD Flex Cassette is OM5 MPO to LC and supports 12 fibers total. It is optimized IL and uses Modified Method A polarity with flipped pairs. The cassette has a black cover with a black MPO connector and 6 lime duplex LC adapters with integral shutters to prevent contamination.

Frequently Asked Questions

What fiber count does the FCS29N-12-03P cassette support?

The FCS29N-12-03P cassette supports a fiber count of 12.

What type of fiber is used in the FCS29N-12-03P cassette?

The FCS29N-12-03P cassette uses OS2 singlemode fiber.

What connector type does the FCS29N-12-03P cassette feature?

The FCS29N-12-03P cassette features SC duplex connectors.

What is the insertion loss for the FCS29N-12-03P cassette?

The standard insertion loss for the OS2 fiber in this cassette is 0.35dB plus splice loss.

What is the operating temperature range for these cassettes?

The operating temperature range for the cassettes is 0°C to 70°C (32°F to 158°F).

What is the storage temperature range for the splice cassettes?

The storage and shipping temperature range is -40°C to 75°C (-40°F to 167°F).

What is the return loss performance for singlemode cassettes?

Singlemode cassettes have a return loss per fiber of greater than 55dB.

How durable are the connectors in terms of mating cycles?

The connectors have a durability of 500 mating cycles.

What material is used for the split sleeves in OS2 cassettes?

The split sleeve material for OS2 singlemode cassettes is Zirconia Ceramic.

Are these splice cassettes compatible with other Panduit enclosures?

Yes, the cassettes are compatible with all Opticom Enclosures (FRME*, FCE*) and patch panels.

How to Install and Splice the FCS29N-12-03P Opticom SC Splice Cassette

This guide provides step-by-step instructions for preparing, splicing, and installing the FCS29N-12-03P Opticom SC Splice Cassette into a compatible fiber optic panel or enclosure.

Estimated time: 2h

Tools needed:

#2 Phillips screwdriver, Scissors, Fiber splicer, Fiber cleaver, Fiber strippers

Supplies needed:

Pan-Ty Cable Ties, 1/4” Phillips Screws, Discreet Splice Sleeves, Isopropyl alcohol, Lint-free wipes, Dust caps, Grommets

  1. Observe Safety Precautions

    WARNING: Unmated connectors may emit invisible laser radiation. Always maintain dust caps on unmated connectors. CAUTION: Fiber optic cable is sensitive to excessive pulling, bending, and crushing forces. Consult the manufacturer’s cable specification sheet for the specific cable in use.

  2. Remove Cassette Cover

    Push down the Cover Removal Latch located in the rear of the cassette. Slide the cover back until the four tabs clear the cassette base. Set the cover aside.

  3. Prepare Incoming Fiber Cable

    Strip the incoming fiber cable outer jacket approximately 20 inches (0.5 meters). Secure the incoming fiber cable to the cassette base using two provided Pan-Ty Cable Ties. Optionally, secure the incoming fiber cable's Aramid yarn to the base using the provided 1/4” Phillips screw(s).

  4. Prepare and Splice Fibers

    Expose all fiber ends for splicing. Slide a splice sleeve onto either the pigtail or field fiber. Strip approximately 1.375” (35mm) of coating from each fiber and clean with isopropyl alcohol. Cleave the fiber so that 0.400” (10mm) of bare fiber extends past the fiber coating. Do not clean bare fiber after cleaving. Splice all fibers according to your splicer manufacturer's best practices and heat the splice sleeve(s).

  5. Route and Secure Spliced Fibers

    Carefully route the spliced fibers into the cassette, ensuring they are located under the Base Fiber Retention Tabs. Secure the splice sleeves into the Discrete Splice Sleeve Holders on the base. The base has capacity for 12 discrete splice sleeves.

  6. Re-install Cassette Cover

    Align the cassette cover with the base and slide it forward until the Cover Removal Latch 'clicks' into place, ensuring all four tabs are engaged underneath the base tabs.

  7. Install Cassette into Panel or Enclosure

    Install the cassette onto the front of compatible panels or enclosures by snapping the two grommets into the designated holes. For rear installation, temporarily remove the bezel by pushing the bezel latch inward, install the cassette, then re-attach the bezel and secure grommets to the front.

Frequently Asked Questions about Panduit

What environmental ratings do Panduit products have?

Panduit products feature comprehensive environmental ratings across multiple standards, including UL 508A Type 1, 2, 3, 4, 4X, 12, and 13; CSA Type 1, 2, 3, 4, 4X, 12, and 13; and NEMA Type 1, 2, 3, 4, 4X, 12, and 13. They meet IEC 60529 IP66 rating, providing robust protection against dust, water, and corrosion in both indoor and outdoor environments, with operating temperatures ranging from -40°C to 130°C.

What certifications and standards do Panduit products comply with?

Panduit products are certified to multiple critical industry standards, including UL (Underwriters Laboratories) in the USA and Canada, CSA (Canadian Standard Association), EN IEC 61386, LVD 2006/G5/EC, and ARRA standards. Our products meet rigorous certifications for electrical safety, environmental compliance (WEEE and RoHS), and are designed to perform in extreme temperatures ranging from -55°C to 105°C, making them suitable for demanding industrial environments.

What industries and applications are Panduit products used for?

Panduit products are engineered for critical applications across multiple industries, including commercial construction, food and beverage, oil and gas, renewable energy, transportation, and safety-critical environments. Their solutions span electrical infrastructure, wire management, cable ties, power connectors, and safety systems designed to withstand extreme conditions like high vibration, temperature variations, UV exposure, and corrosive agents. Key industries include solar and wind energy, aerospace, heavy trucking, military, commercial transportation, and industrial manufacturing.

What are the main product lines offered by Panduit?

Panduit offers a comprehensive range of electrical infrastructure products including power connectors, cable ties, grounding connectors, identification products, safety solutions, terminals, cable cleats, wiring duct, and cable tie accessories. These products are engineered for industrial environments across multiple sectors like commercial construction, food and beverage, oil and gas, renewable energy, transportation, and safety applications.

What are the key features of Panduit products?

Panduit products are engineered for robust performance in heavy-duty industrial environments, featuring a comprehensive range of solutions including cable ties, power connectors, terminals, and identification products. Key features include proven quality performance, subject matter expertise, and customer-driven innovation across multiple industrial sectors such as commercial construction, food and beverage, oil and gas, renewable energy, transportation, and safety applications. The product line is designed to maximize productivity, reliability, and safety while meeting stringent industry standards.

What is Panduit's warranty policy?

Panduit provides a comprehensive Limited Product Warranty that can be fully reviewed on their official website at www.panduit.com/warranty. All Panduit products are subject to the terms, conditions, and limitations of this current warranty. Customers are advised to review the specific warranty details for their particular product, as Panduit requires buyers to determine product suitability for their intended use and assumes all associated risks.

What technical support does Panduit offer?

Panduit offers comprehensive technical support through their dedicated customer service team, accessible via phone at 1-800-777-3300. They provide expert assistance for their full range of industrial infrastructure products, including cable ties, power connectors, terminals, and identification solutions. Customers can also access additional technical resources and product information through their website at www.panduit.com.

What accessories are available for Panduit products?

Panduit offers a wide range of accessories across multiple product lines, including cable ties, cable tie accessories, cable tie tools, identification products, cable cleats, grounding connectors, and VeriSafe accessories like the VeriSafe Network Module and Insulation Piercing Connectors. For a comprehensive view of all available accessories, customers are recommended to visit www.panduit.com for the full product catalog.

How are Panduit products typically installed?

Panduit products are engineered for comprehensive installation across industrial environments, utilizing specialized tools and techniques for precise mounting. Installation methods vary by product line - from cable ties and power connectors to terminals and identification solutions - but all are designed for robust performance in heavy-duty settings. Technicians typically use Panduit's dedicated installation tools and follow manufacturer guidelines available at www.panduit.com to ensure proper fitting and maximum infrastructure reliability.