Contact for Pricing
Overview
- Preloaded with 24 OS2 discrete pigtails (250µm) and splice kit
- Standard II cassette with removable bevel for simplified installation
- LC/APC connectors for OS2 single-mode fiber
- Supports 10G/40G/100G applications
- Manufactured in the US for industrial-grade reliability
Specifications
Connection Type | LC/APC |
Material | Plastic |
Material | Poly |
Mounting Type | Rack-Mount |
Mounting Type | Rack-mounted |
Series | Opticom |
Series | Opticom LC/APC Splice Cassette |
Size | Standard Il cassette |
Size | Standard II cassette |
Package Dimensions (L x W x H) | 9.2 IN x 4.5 IN x 2.6 IN |
Package Dimensions (L x W x H) | 23.368 cm x 11.43 cm x 6.604 cm |
Package Weight (Imperial) | 0.3500 L |
Package Weight (Metric) | 0.1588 kg |

FC2WO-12-10AS
The Opticom Fiber Cassette is OM5, and features 1 MPO to 6 duplex LC and supports 12 fibers total. It is optimized IL and uses Standard Method A polarity. The cassette has a black cover with a black MPO connector and 6 lime LC adapters.Frequently Asked Questions
What enclosures are compatible with these splice cassettes?
Opticom splice cassettes are compatible with all Opticom Enclosures (FRME* and FCE*) and patch panels.
What accessories are included with the splice cassettes?
The cassettes include splice protectors, splice holders, cable ties, and 1-meter pigtails for field splicing.
What fiber count and type does the FCS29N-24-LAP cassette have?
The FCS29N-24-LAP cassette has 24 fibers of OS2 singlemode type.
What connector type does the FCS29N-24-LAP cassette use?
The FCS29N-24-LAP cassette uses LC/APC duplex connectors.
What is the operating temperature range for these cassettes?
The operating temperature range for the splice cassettes is 0°C to 70°C (32°F to 158°F).
What is the storage and shipping temperature range?
The storage and shipping temperature range is -40°C to 75°C (-40°F to 167°F).
What is the insertion loss for the FCS29N-24-LAP cassette?
The FCS29N-24-LAP cassette has a standard OS2 insertion loss of 0.35dB plus splice loss.
What is the return loss performance for singlemode cassettes?
Singlemode cassettes have a return loss per fiber of greater than 55dB.
How durable are the connectors on these cassettes?
The connectors meet TIA/EIA-568C.3 A.4.9 and have a durability of 500 mating cycles.
What is the length of the pigtails included?
The splice cassettes include 1-meter pigtails.
How to Install and Splice the FCS29N-24-LAP Opticom LC Splice Cassette
This guide provides step-by-step instructions for preparing, splicing incoming fiber cables to, and installing the FCS29N-24-LAP Opticom LC Splice Cassette into a panel or enclosure.
Estimated time: 1h 30m
Tools needed:
#2 Phillips screwdriver, Scissors, Fiber strippers, Fiber cleaver, Fusion splicer
Supplies needed:
Pan-Ty Cable Ties, 1/4" Phillips Screws, Discrete Splice Sleeves, Isopropyl alcohol, Dust caps
- Prepare the Cassette for Splicing
Push down the Cover Removal Latch in the rear of the cassette and slide the Cover back until the 4 tabs clear, then remove it. If equipped with a Splice Tray, squeeze the two tabs on either side inward or pull the Base wall outward to release and remove the Splice Tray from the Base. Carefully set aside any coiled pigtail fiber ends. WARNING: UNMATED CONNECTORS MAY EMIT INVISIBLE LASER RADIATION. MAINTAIN DUST CAPS ON UNMATED CONNECTORS. CAUTION: Fiber optic cable is sensitive to excessive pulling, bending, and crushing forces. Consult the manufacturer’s cable specification sheet for the specific cable in use.
- Prepare and Secure Incoming Fiber Cables
Strip the incoming fiber cable outer jacket by 20 inches (0.5 meters). Secure the incoming fiber cable to the Base using two provided Pan-Ty Cable Ties. Cut off any excess cable tie material. Optionally, secure the incoming fiber cable's Aramid yarn to the Base using the provided 1/4” Phillips screw(s). Expose all fiber ends for splicing.
- Splice Fibers to the Cassette Base
Slide a discrete splice sleeve onto either the pigtail or field fiber. Strip approximately 1.375 inches (35mm) of coating from each fiber and clean with isopropyl alcohol. Cleave the fiber so that 0.400 inches (10mm) of bare fiber extends past the fiber coating. Do not clean the bare fiber after cleaving or let it contact any surfaces. Splice all fibers designated for the Base and heat the splice sleeve(s) according to your splicer manufacturer's instructions. Route the spliced fibers into the cassette, ensuring they are located under the Base fiber retention tabs. Secure the splice sleeves into the discrete Splice Sleeve Holders in the Base (capacity for 12 discrete splices).
- Install Splice Tray and Splice Remaining Fibers
Replace the Splice Tray into the Base, ensuring no fibers previously spliced onto the base protrude above the Base Fiber Retention Tabs. Push until an audible 'CLICK' is heard. Route the remaining incoming fiber cable (if a 24-fiber cable is being used) to the Splice Tray. Repeat the splicing steps (strip, clean, cleave, splice, heat, route, secure) for the remaining fibers on the Splice Tray (capacity for 12 discrete splices).
- Complete Cassette Assembly and Installation
After all splicing is complete, re-install the Cassette Cover by pushing it forward until the Cover Removal Latch 'clicks' into place. Install the assembled cassette directly to the front of a panel or enclosure by snapping the two grommets into the designated holes. Optionally, for rear installation, temporarily remove the Bezel by pushing the Bezel latch inward to release it, install the cassette through the rear of the panel/enclosure, then re-attach the Bezel and secure the grommets to the front.
Frequently Asked Questions about Panduit
What environmental ratings do Panduit products have?
Panduit products feature comprehensive environmental ratings across multiple standards, including UL 508A Type 1, 2, 3, 4, 4X, 12, and 13; CSA Type 1, 2, 3, 4, 4X, 12, and 13; and NEMA Type 1, 2, 3, 4, 4X, 12, and 13. They meet IEC 60529 IP66 rating, providing robust protection against dust, water, and corrosion in both indoor and outdoor environments, with operating temperatures ranging from -40°C to 130°C.
What certifications and standards do Panduit products comply with?
Panduit products are certified to multiple critical industry standards, including UL (Underwriters Laboratories) in the USA and Canada, CSA (Canadian Standard Association), EN IEC 61386, LVD 2006/G5/EC, and ARRA standards. Our products meet rigorous certifications for electrical safety, environmental compliance (WEEE and RoHS), and are designed to perform in extreme temperatures ranging from -55°C to 105°C, making them suitable for demanding industrial environments.
What industries and applications are Panduit products used for?
Panduit products are engineered for critical applications across multiple industries, including commercial construction, food and beverage, oil and gas, renewable energy, transportation, and safety-critical environments. Their solutions span electrical infrastructure, wire management, cable ties, power connectors, and safety systems designed to withstand extreme conditions like high vibration, temperature variations, UV exposure, and corrosive agents. Key industries include solar and wind energy, aerospace, heavy trucking, military, commercial transportation, and industrial manufacturing.
What are the main product lines offered by Panduit?
Panduit offers a comprehensive range of electrical infrastructure products including power connectors, cable ties, grounding connectors, identification products, safety solutions, terminals, cable cleats, wiring duct, and cable tie accessories. These products are engineered for industrial environments across multiple sectors like commercial construction, food and beverage, oil and gas, renewable energy, transportation, and safety applications.
What are the key features of Panduit products?
Panduit products are engineered for robust performance in heavy-duty industrial environments, featuring a comprehensive range of solutions including cable ties, power connectors, terminals, and identification products. Key features include proven quality performance, subject matter expertise, and customer-driven innovation across multiple industrial sectors such as commercial construction, food and beverage, oil and gas, renewable energy, transportation, and safety applications. The product line is designed to maximize productivity, reliability, and safety while meeting stringent industry standards.
What is Panduit's warranty policy?
Panduit provides a comprehensive Limited Product Warranty that can be fully reviewed on their official website at www.panduit.com/warranty. All Panduit products are subject to the terms, conditions, and limitations of this current warranty. Customers are advised to review the specific warranty details for their particular product, as Panduit requires buyers to determine product suitability for their intended use and assumes all associated risks.
What technical support does Panduit offer?
Panduit offers comprehensive technical support through their dedicated customer service team, accessible via phone at 1-800-777-3300. They provide expert assistance for their full range of industrial infrastructure products, including cable ties, power connectors, terminals, and identification solutions. Customers can also access additional technical resources and product information through their website at www.panduit.com.
What accessories are available for Panduit products?
Panduit offers a wide range of accessories across multiple product lines, including cable ties, cable tie accessories, cable tie tools, identification products, cable cleats, grounding connectors, and VeriSafe accessories like the VeriSafe Network Module and Insulation Piercing Connectors. For a comprehensive view of all available accessories, customers are recommended to visit www.panduit.com for the full product catalog.
How are Panduit products typically installed?
Panduit products are engineered for comprehensive installation across industrial environments, utilizing specialized tools and techniques for precise mounting. Installation methods vary by product line - from cable ties and power connectors to terminals and identification solutions - but all are designed for robust performance in heavy-duty settings. Technicians typically use Panduit's dedicated installation tools and follow manufacturer guidelines available at www.panduit.com to ensure proper fitting and maximum infrastructure reliability.