Contact for Pricing
Overview
- Steel construction for durability
- 1-inch hub size
- Accommodates outer jacket diameters from 1.025 to 1.205 inches
- PVC coated for environmental protection
- Manufactured by ABB - Installation Products
Specifications
Application | For Hazardous Locations |
Color | Black |
Finish | PVC |
Material | Steel |
Size | 1 Inch |
Standard | CSA 23086 |
Type | Teck Cable Fittings |
Package Dimensions (L x W x H) | 6.12 IN x 4.62 IN x 3.25 IN |
Package Dimensions (L x W x H) | 15.5448 cm x 11.7348 cm x 8.255 cm |
Package Weight (Imperial) | 1.6200 L |
Package Weight (Metric) | 0.7350 kg |

ST150-473SPVC
Star Teck steel jacketed fitting PVC coated. Hub size of 1-1/2 inch. Range over jacket from 1.900 - 2.187 inches.
ST075-468SPVC
Star Teck steel jacketed fitting PVC coated. Hub size of 3/4 inch. Range over jacket from 1.025 - 1.205 inch.
ST050-464SPVC
Star Teck steel jacketed fitting PVC coated. Hub size of 1/2 inch. Range over jacket from 0.600 - 0.760 inch.
ST050-462SPVC
Star Teck steel jacketed fitting PVC coated. Hub size of 1/2 inch. Range over jacket from 0.525 - 0.650 inch.
ST050-465SPVC
Star Teck steel jacketed fitting PVC coated. Hub size of 1/2 inch. Range over jacket from 0.725 - 0.885 inch.
ST050-466SPVC
Star Teck steel jacketed fitting PVC coated. Hub size of 1/2 inch. Range over jacket from 0.825 - 0.985 inch.
ST075-467SPVC
Star Teck steel jacketed fitting PVC coated. Hub size of 3/4 inch. Range over jacket from 0.880 - 1.065 inch.
ST100-469SPVC
Star Teck steel jacketed fitting PVC coated. Hub size of 1 inch. Range over jacket from 1.187 - 1.375 inch.
ST125-470SPVC
Star Teck steel jacketed fitting PVC coated. Hub size of 1-1/4 inch. Range over jacket from 1.350 - 1.625 inch.
ST125-471SPVC
Star Teck steel jacketed fitting PVC coated. Hub size of 1-1/4 inch. Range over jacket from 1.600 - 1.875 inch.
ST150-472SPVC
Star Teck steel jacketed fitting PVC coated. Hub size of 1-1/2 inch. Range over jacket from 1.700 - 1.965 inch.How to Install an STX Series Star Teck PVC Cable Fitting for Shielded Cables
This guide provides step-by-step instructions for preparing, assembling, and sealing an STX Series Star Teck PVC cable fitting, specifically for shielded data cables, using liquid-type sealing compound.
Estimated time: 1h 30m
Tools needed:
Hacksaw, Strap wrenches, Damp cloth, Gloves
Supplies needed:
SC4-KIT-1 LIQUID SEALANT (1 unit), Lubricant, Fiber damming material, STX Series compatible cable
- De-energize Circuits and Prepare Cable
WARNING: Risk of electrical shock. Before installing, verify that all circuits are de-energized. Determine the working length of conductors required inside the enclosure or device. Remove a portion of the outer jacket to expose the armor, then cut the armor using a hacksaw. CAUTION: Do not nick or cut the conductor insulation. Trim the outer jacket to expose 1 inch of armor for the STX100-468PVC fitting.
- Prepare the Cable Boot
Unscrew the gland nut from the body. Choose a method to cut the cable boot: Method 1: Force the square-cut cable into the boot, then cut the boot in front of the cable. Method 2: Strip the cable jacket off the armor, then progressively cut slices off the boot until the opening can snugly slide onto the armor. Apply lubricant where indicated prior to screwing the gland nut.
- Feed and Seal the Cable
Feed the cable through the gland nut opening and push until the cable armor hits the end stop. Tighten the gland nut using strap wrenches until you obtain an appropriate seal or to the maximum torque of 600 in-lbs. Ensure the bushing seals evenly around the cable’s outer jacket and the cable remains centered to obtain an optimal seal.
- Disassemble for Sealing Compound Application
Disassemble the hub from the body sub-assembly by loosening the union. Unscrew the sealing chamber from the body sub-assembly.
- Prepare Shielded Data Cable Conductors
Trim the inner jacket to a length of 1/8 to 3/8 inches to expose the shielded conductor bundle. Carefully remove the outer (overall) shield from the conductor bundle, taking care not to nick or damage any inner shields. Remove any filler materials, ensuring not to disturb or damage the inner shields.
- Apply Liquid Sealing Compound (SC4-KIT-1)
Tightly pack fiber damming material into all voids between conductors and the body. Spread strands of any uninsulated grounding conductor where applicable. Screw the sealing chamber back onto the body subassembly until it completely seats on the body. Position the cable/fitting into a vertical position. Mix the SC4-KIT-1 liquid sealing compound following the instructions provided on its package. Dispense the sealing compound into the end of the sealing chamber until the level of compound stabilizes, filling it to the top. CAUTION: Remove all excess compound material from outside of the sealing chamber with a damp cloth. Do not use abrasive cleaners.
- Mount Hub and Secure Assembly
Mount the hub in the desired location. When the sealing compound is solidified (after approximately 1 hour), place the encapsulated assembly into the hub and secure it in position by tightening the union until it bottoms (metal to metal contact).
Frequently Asked Questions about ABB - Installation Products
How are Thomas and Betts products typically installed?
Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.
What accessories are available for Thomas and Betts products?
Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.
What environmental ratings do Thomas and Betts products have?
Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.
What communication protocols do Thomas and Betts products support?
Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.
What are the key features of Thomas and Betts products?
Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.
What are the main product lines offered by Thomas and Betts?
Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.
What technical support does Thomas and Betts offer?
Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.
What industries and applications are Thomas and Betts products used for?
Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.
What certifications and standards do Thomas and Betts products comply with?
Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.
What are the main product lines offered by Ocal?
Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.