The ABB STAR TECK XP fitting (SKU: STX075-465SPVC) is a steel cable gland designed for hazardous environments, particularly in petrochemical, oil, and gas industries. This fitting features a 3/4" hub size and accommodates outer jacket diameters from 0.725 to 0.885 inches, with a PVC coating for added corrosion resistance. The integral sealing chamber is designed for easy filling with liquid or putty sealants, eliminating the need for cement-based sealants. The disconnectable design reduces cable preparation time, simplifying installation in tight or complex layouts. This fitting meets the demands of hazardous area installations where reliable sealing and quick assembly are critical. The STAR TECK XP line was developed in collaboration with engineers from the petrochemical, oil, and gas sectors to address the challenges of cable management in explosive atmospheres. The fitting is part of ABB’s Installation Products portfolio, ensuring compatibility with industry-standard components. The steel construction provides robust durability for demanding applications. The PVC coating offers enhanced protection against environmental factors. The specific hub size of 3/4 inch ensures precise integration with compatible conduit systems. The specified range for outer jacket diameters ensures a secure and effective seal for a variety of cable types.
  • 3/4" hub size with PVC coating for corrosion resistance
  • Accommodates outer jacket diameters from 0.725 to 0.885 inches
  • Integral sealing chamber for easy liquid or putty sealant application
  • Disconnectable design reduces cable preparation time
  • Developed for petrochemical, oil, and gas hazardous environments

Specifications

Application
For Hazardous Locations
Color
Black
Finish
PVC
Material
Steel
Size
3/4 Inch
Standard
CSA 23086
Type
Teck Cable Fittings
Package Dimensions (L x W x H)
0.01 IN x 0.01 IN x 0.01 IN
Package Dimensions (L x W x H)
0.0254 cm x 0.0254 cm x 0.0254 cm
Package Weight (Imperial)
1.0500 L
Package Weight (Metric)
0.4760 kg
Tie Wire, Trade Size 0.06, Length 300 Feet, Working Load 125 Pounds, 16 Gauge Steel

CI8960

Tie Wire, Trade Size 0.06, Length 300 Feet, Working Load 125 Pounds, 16 Gauge Steel
Star Teck steel jacketed fitting PVC coated. Hub size of 1-1/2 inch. Range over jacket from 1.900 - 2.187 inches.

ST150-473SPVC

Star Teck steel jacketed fitting PVC coated. Hub size of 1-1/2 inch. Range over jacket from 1.900 - 2.187 inches.
Star Teck steel jacketed fitting PVC coated. Hub size of 3/4 inch. Range over jacket from 1.025 - 1.205 inch.

ST075-468SPVC

Star Teck steel jacketed fitting PVC coated. Hub size of 3/4 inch. Range over jacket from 1.025 - 1.205 inch.
Star Teck steel jacketed fitting PVC coated. Hub size of 1/2 inch. Range over jacket from 0.600 - 0.760 inch.

ST050-464SPVC

Star Teck steel jacketed fitting PVC coated. Hub size of 1/2 inch. Range over jacket from 0.600 - 0.760 inch.
Star Teck steel jacketed fitting PVC coated. Hub size of 1/2 inch. Range over jacket from 0.525 - 0.650 inch.

ST050-462SPVC

Star Teck steel jacketed fitting PVC coated. Hub size of 1/2 inch. Range over jacket from 0.525 - 0.650 inch.
Star Teck steel jacketed fitting PVC coated. Hub size of 1/2 inch. Range over jacket from 0.725 - 0.885 inch.

ST050-465SPVC

Star Teck steel jacketed fitting PVC coated. Hub size of 1/2 inch. Range over jacket from 0.725 - 0.885 inch.
Star Teck steel jacketed fitting PVC coated. Hub size of 1/2 inch. Range over jacket from 0.825 - 0.985 inch.

ST050-466SPVC

Star Teck steel jacketed fitting PVC coated. Hub size of 1/2 inch. Range over jacket from 0.825 - 0.985 inch.
Star Teck steel jacketed fitting PVC coated. Hub size of 3/4 inch. Range over jacket from 0.880 - 1.065 inch.

ST075-467SPVC

Star Teck steel jacketed fitting PVC coated. Hub size of 3/4 inch. Range over jacket from 0.880 - 1.065 inch.
Star Teck steel jacketed fitting PVC coated. Hub size of 1 inch. Range over jacket from 1.187 - 1.375 inch.

ST100-469SPVC

Star Teck steel jacketed fitting PVC coated. Hub size of 1 inch. Range over jacket from 1.187 - 1.375 inch.
Star Teck steel jacketed fitting PVC coated. Hub size of 1-1/4 inch. Range over jacket from 1.350 - 1.625 inch.

ST125-470SPVC

Star Teck steel jacketed fitting PVC coated. Hub size of 1-1/4 inch. Range over jacket from 1.350 - 1.625 inch.
Star Teck steel jacketed fitting PVC coated. Hub size of 1-1/4 inch. Range over jacket from 1.600 - 1.875 inch.

ST125-471SPVC

Star Teck steel jacketed fitting PVC coated. Hub size of 1-1/4 inch. Range over jacket from 1.600 - 1.875 inch.
Star Teck steel jacketed fitting PVC coated. Hub size of 1-1/2 inch. Range over jacket from 1.700 - 1.965 inch.

ST150-472SPVC

Star Teck steel jacketed fitting PVC coated. Hub size of 1-1/2 inch. Range over jacket from 1.700 - 1.965 inch.

Frequently Asked Questions

Are there specific installation code requirements?

Yes, the product must be installed in accordance with applicable national and local electrical codes.

Is the product suitable for wet and dry locations?

Yes, the product conforms to UL514B and CSA C22.2-18.3, making it suitable for both wet and dry locations.

What hazardous location classifications does it meet?

It conforms to CSA 22.2 and UL2225 for Class I Div1 ABCD, Class II Div1 EFG, and Class III Div1 hazardous locations.

What is the ingress protection rating?

The product has an ingress protection rating of Type 4 / 4X.

What is the operating temperature range?

The normal operating temperature range for this product is -40 to +90°C (-40 to +194°F).

When should I use SC4-KIT-1 vs SC65 sealing compound?

Use SC4-KIT-1 for shielded cables or cables with 5+ conductors. SC65 is for cables with a maximum of 4 conductors and is not recommended for shielded cables.

What materials is the STX075-465SPVC made from?

The STX075-465SPVC is made from zinc-plated steel with a PVC coating. Copper-free aluminum is another material option for the base product.

What cable types are compatible with this product?

This product is suitable for jacketed Teck and ACWU cables, armored control and instrument (ACIC Div2) cables, and Type MC jacketed corrugated metal clad cables.

What sealing compounds are required for installation?

The STX075-465SPVC must be installed with either SC4-KIT-1 liquid compound or SC65 putty sealing compound, which are sold separately.

What sealing compounds are required for installation?

The STX075-465SPVC must be installed with either SC4-KIT-1 liquid compound or SC65 putty sealing compound, which are sold separately.

How to Install the STX075-465PVC Cable Fitting for Shielded Cables

This guide provides detailed instructions for installing the STX075-465PVC Star Teck™ PVC cable fitting specifically for shielded data cables, including cable preparation, fitting assembly, and sealing with SC4-KIT-1 liquid compound.

Estimated time: 1h 30m

Tools needed:

Hacksaw, Strap wrenches, Wire strippers, Gloves

Supplies needed:

STX075-465PVC Cable Fitting, SC4-KIT-1 LIQUID SEALANT, Fiber damming material, Lubricant, Damp cloth, Shielded data cable, Proper PPE

  1. De-energize Circuits and Prepare for Installation

    WARNING: Risk of electrical shock. Before installing or performing maintenance, verify that all circuits are de-energized. Ensure installation is performed by a qualified electrician in accordance with national and local electrical codes. Gather all required tools and supplies, including the appropriate SC4-KIT-1 liquid sealing compound for hazardous locations.

  2. Prepare the Cable Armor and Outer Jacket

    Determine the working length of conductors required inside the enclosure. Remove a portion of the outer jacket to expose the cable armor. Cut the exposed armor using a hacksaw. CAUTION: Do not nick or cut the conductor insulation. Trim the outer jacket to expose the armor strip length as indicated in the product table (0.617-0.805 inches for STX075-465PVC).

  3. Prepare Shielded Data Cable Conductors

    Trim the inner jacket to a length of 1/8”-3/8” to expose the shielded conductor bundle. Remove the outer (overall) shield from the conductor bundle, taking care not to nick or damage the inner shields. Remove any filler materials, ensuring not to disturb or damage inner shields.

  4. Prepare the Cable Boot

    Unscrew the gland nut from the fitting body. Choose one method to prepare the cable boot: Method 1: Force the square-cut cable into the boot, then cut the boot in front of the cable end. Method 2: Strip the cable jacket off the armor, then progressively cut slices off the boot until the opening can snugly slide onto the armor. Apply lubricant where indicated prior to screwing the gland nut.

  5. Insert Cable and Secure Gland Nut

    Feed the prepared cable through the gland nut opening. Push the cable until the cable armor hits the end stop inside the fitting. Tighten the gland nut using strap wrenches until an appropriate seal is obtained or to the maximum torque of 600 in-lbs for STX075-465PVC. Ensure the bushing seals evenly around the cable’s outer jacket and the cable remains centered for an optimal seal.

  6. Disassemble for Sealing Compound Application

    Disassemble the hub from the body sub-assembly by loosening the union. Unscrew the sealing chamber from the body sub-assembly.

  7. Pack Fiber Damming Material and Reassemble Sealing Chamber

    Pack the fiber damming material tightly into all voids between the conductors and the body. Spread the strands of any uninsulated grounding conductor, if applicable. Screw the sealing chamber back onto the body subassembly until it completely seats on the body.

  8. Mix and Pour Liquid Sealing Compound

    Position the cable and fitting into a vertical orientation. Mix the SC4-KIT-1 liquid sealing compound according to the instructions provided on its package. Dispense the mixed sealing compound into the end of the sealing chamber until the level of compound stabilizes and fills to the top (for STX075-465PVC). CAUTION: Immediately remove all excess compound material from the outside of the sealing chamber with a damp cloth. Do not use abrasive cleaners such as powder cleaners, sandpaper, steel wool, or wire brush that may damage the flame path.

  9. Mount Hub and Finalize Assembly

    Allow the sealing compound to solidify for approximately 1 hour. Mount the hub in the desired location. Place the encapsulated assembly into the hub and secure it in position by tightening the union until it bottoms (metal to metal contact).

Frequently Asked Questions about ABB - Installation Products

How are Thomas and Betts products typically installed?

Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.

What accessories are available for Thomas and Betts products?

Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.

What environmental ratings do Thomas and Betts products have?

Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.

What communication protocols do Thomas and Betts products support?

Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.

What are the key features of Thomas and Betts products?

Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.

What are the main product lines offered by Thomas and Betts?

Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.

What technical support does Thomas and Betts offer?

Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.

What industries and applications are Thomas and Betts products used for?

Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.

What certifications and standards do Thomas and Betts products comply with?

Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.

What are the main product lines offered by Ocal?

Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.