Authorized ABB Distributor (Installation Products)
ABB - Installation Products R2T35J4-N0330 - Ranger2 Termination for 35KV outdoor application, cable insulation diameter 1.30 - 2.10 for Concentric Neural and Jacketed Concentric Neutral Cable, includes Aluminum 2-Hole Spade connector for #2 through 1250 kcmil. Conductor Code 330 - 500 kcmil Stranded/Compressed or 600 kcmil Compact/Solid.

ABB Installation Products R2T35J4-N0330 Ranger2 Termination for 35KV outdoor application, cable insulation diameter 1.30 - 2.10…

UPC: 783786959013


Documents & Media
Installation InstructionsSpecification SheetManufacturer Product Website

Contact for Pricing

Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.

Overview

The ABB Ranger2 Termination (SKU: R2T35J4-N0330) is a high-reliability outdoor termination kit designed for 35KV applications with concentric neutral or jacketed concentric neutral cables. This termination supports conductor insulation diameters from 1.30 to 2.10 inches and accommodates stranded/compressed conductors in the 330–500 kcmil range or compact/solid 600 kcmil conductors. The included aluminum 2-hole spade connector ensures secure electrical and mechanical connections for cable sizes from #2 AWG through 1250 kcmil, making it suitable for medium-voltage distribution systems in utility, industrial, and renewable energy installations. The termination is engineered for outdoor environments, providing weatherproof sealing and long-term dielectric integrity. It is part of ABB’s Ranger2 line, known for consistent performance in harsh conditions. For projects requiring compliant, field-proven terminations with minimal installation complexity, the R2T35J4-N0330 delivers certified reliability and compatibility with standard utility practices.
  • Rated for 35KV outdoor applications with concentric neutral or jacketed concentric neutral cables
  • Supports conductor insulation diameter range: 1.30 – 2.10 inches
  • Compatible with stranded/compressed conductors: 330 – 500 kcmil
  • Compatible with compact/solid conductors: 600 kcmil
  • Includes aluminum 2-hole spade connector for #2 AWG to 1250 kcmil

Specifications

Application
Cable Termination, Outdoor Application, 35kV
Cable Type
Concentric Neutral Wire
Color
Gray
Conductor Size
500 to 600 kcmil
Earthing
Products Includes Their Own Grounding System
Mounting
Product Need to have Cable Holder (not included)
Number Of Terminals
(1) Single Phase
Special Features
Silicone Rubber Housing. Lightweight, Compact Design. Pull-Down Tabs for Easy Installation. Thick Wall Construction
Standard
IEEE 48
Type
Cable Termination - Outdoor - Ranger2
Voltage Rating
35 kV
Package Dimensions (L x W x H)
0.01 IN x 0.01 IN x 0.01 IN
Package Dimensions (L x W x H)
0.0254 cm x 0.0254 cm x 0.0254 cm
Package Weight (Imperial)
1.0000 L
Package Weight (Metric)
0.4540 kg
Ranger2 Termination for 35KV outdoor application, cable insulation diameter .84 - 1.38 inches for Cable Type - Tape Shield, Wire Shield, and Unshielded Cable, Copper 2-Hole Spade #2-1250kcmil, Stranded or Compressed 500/ Compact or Solid 600 .

R2T35M4N2330

Ranger2 Termination for 35KV outdoor application, cable insulation diameter .84 - 1.38 inches for Cable Type - Tape Shield, Wire Shield, and Unshielded Cable, Copper 2-Hole Spade #2-1250kcmil, Stranded or Compressed 500/ Compact or Solid 600 .
Ranger2 Termination for 15KV outdoor application, cable insulation diameter .84-1.38 inches for Concentric Neural and Jacketed Concentric Neutral Cable, Aluminum 2 Hole Spade #2-1250kcmil, Stranded or Compressed 400 /Compact or Solid 500. Stainless Steel Mounting Bracket 1.45 inch - 1.95 inch (37-50mm)

R2T15J2-N0310-B3

Ranger2 Termination for 15KV outdoor application, cable insulation diameter .84-1.38 inches for Concentric Neural and Jacketed Concentric Neutral Cable, Aluminum 2 Hole Spade #2-1250kcmil, Stranded or Compressed 400 /Compact or Solid 500. Stainless Steel Mounting Bracket 1.45 inch - 1.95 inch (37-50mm)
Ranger2 Termination, Outdoor, 25/28kV, Cable Type - Tape Shield/Wire Shield/UniSheild, Insulation Range .84-1.38 inch (21-35mm), Connector Type - Universal Aluminum Barrel for Aluminum or Copper with Copper Wire Lead #2-4/0. Conductor Code 240 - Stranded/Compressed 1/0 or Compact/Solid 2/0. Cable Mounting Bracket Size .80-1.25 inch (20-32mm), Bracket Material - Stainless Steel

R2T28M2T0240-B1

Ranger2 Termination, Outdoor, 25/28kV, Cable Type - Tape Shield/Wire Shield/UniSheild, Insulation Range .84-1.38 inch (21-35mm), Connector Type - Universal Aluminum Barrel for Aluminum or Copper with Copper Wire Lead #2-4/0. Conductor Code 240 - Stranded/Compressed 1/0 or Compact/Solid 2/0. Cable Mounting Bracket Size .80-1.25 inch (20-32mm), Bracket Material - Stainless Steel
Ranger2 Termination, Outdoor, 25/28kV, Cable Type - Concentric Neutral/Jacketed Concentric Neutral Cable, Insulation Range .84-1.38 inch (21-35mm), Connector Type - Universal Aluminum Barrel for Aluminum or Copper with Copper Wire Lead #2-4/0. Conductor Code 240 - Stranded/Compressed 1/0 or Compact/Solid 2/0. Cable Mounting Bracket Size .80-1.25 inch (20-32mm), Bracket Material - Stainless Steel

R2T28J2T0240-B1

Ranger2 Termination, Outdoor, 25/28kV, Cable Type - Concentric Neutral/Jacketed Concentric Neutral Cable, Insulation Range .84-1.38 inch (21-35mm), Connector Type - Universal Aluminum Barrel for Aluminum or Copper with Copper Wire Lead #2-4/0. Conductor Code 240 - Stranded/Compressed 1/0 or Compact/Solid 2/0. Cable Mounting Bracket Size .80-1.25 inch (20-32mm), Bracket Material - Stainless Steel
Outdoor, Ranger2 Termination, 15kV, Cable Type Tape Shield/Wire Shield/Unishield, Insulation Range 1.30 to 2.10 inch (33-53mm). Connector Type Copper 2-Hole Spade #2-1250 kcmil. Conductor Size 1250 Compressed/Stranded.

R2T15M4-N2440

Outdoor, Ranger2 Termination, 15kV, Cable Type Tape Shield/Wire Shield/Unishield, Insulation Range 1.30 to 2.10 inch (33-53mm). Connector Type Copper 2-Hole Spade #2-1250 kcmil. Conductor Size 1250 Compressed/Stranded.
Ranger 2 Terminator, Outdoor, 15kV, Concentric Neutral/Jacketed Concentric Neutral Cable Type, Insulation Range .84 -1.38 inch (21-35mm) Connector Type - Copper 2-Hole Spade #2-1250 kcmil. 350 Stranded/Compressed or 400 Compact/Solid.

R2T15J2N2300

Ranger 2 Terminator, Outdoor, 15kV, Concentric Neutral/Jacketed Concentric Neutral Cable Type, Insulation Range .84 -1.38 inch (21-35mm) Connector Type - Copper 2-Hole Spade #2-1250 kcmil. 350 Stranded/Compressed or 400 Compact/Solid.
15kV, Ranger2 Cable Termination, Outdoor, Cable Type - Concentric Neutral/Jacketed Concentric Neutral, Insulation Range - .84-1.38 inch (21-35mm), Connector Type - N2 - Copper 2-Hole spade #2-1250 kcmil, Conductor Code 270 - 4/0 Strandeed/Compressed or 250 Compact/Solid.

R2T15J2-N2270

15kV, Ranger2 Cable Termination, Outdoor, Cable Type - Concentric Neutral/Jacketed Concentric Neutral, Insulation Range - .84-1.38 inch (21-35mm), Connector Type - N2 - Copper 2-Hole spade #2-1250 kcmil, Conductor Code 270 - 4/0 Strandeed/Compressed or 250 Compact/Solid.
15kV, Outdoor, Ranger2 Cable Termination, Cable Type - Concentric Neutral/Jacket Concentric Neutral. Insulation Range 0.64 to 1.12 iches, Connector Type H0 - Aluminum 1-Hole Spade #2-500kcmil. Conductor Size - 250 - 2/0 Stranded/Compressed or 3/0 Solid/Compact.

R2T15J1-H0250

15kV, Outdoor, Ranger2 Cable Termination, Cable Type - Concentric Neutral/Jacket Concentric Neutral. Insulation Range 0.64 to 1.12 iches, Connector Type H0 - Aluminum 1-Hole Spade #2-500kcmil. Conductor Size - 250 - 2/0 Stranded/Compressed or 3/0 Solid/Compact.

Frequently Asked Questions

What voltage rating does this termination support?

This termination is rated for 35KV outdoor applications.

What cable insulation diameter range does it accommodate?

The termination supports cable insulation diameters from 1.30 to 2.10 inches.

Which conductor sizes are compatible with this termination?

It supports stranded/compressed conductors from 330 to 500 kcmil and compact/solid 600 kcmil conductors.

What type of neutral cable does this termination work with?

This termination is designed for concentric neutral or jacketed concentric neutral cables.

What connector type is included with this termination?

The kit includes an aluminum 2-hole spade connector.

What conductor size range does the included connector support?

The 2-hole spade connector supports conductor sizes from #2 AWG through 1250 kcmil.

How to Install the R2T35J4-N0330 35kV Cable Terminator

Step-by-step guide for installing the R2T35J4-N0330 35kV Ranger 2 Cable Terminator on concentric and jacketed concentric neutral cables.

Estimated time: 45m

Tools needed:

Screwdriver, Wire strippers, Approved solvent, Aluminum oxide abrasive (grit 120 or finer, if needed)

Supplies needed:

Silicone Rubber Termination Halves, Lubricant, Strips Grey Silicone Rubber Tape, Strips Sealing Mastic, Gloves, Vinyl tape or binding wire, Terminal lug (if not included), System ground connection

  1. Prepare the Cable

    Verify the cable size is within the kit's range. Train the cable into position and cut to the required length, ensuring sufficient neutral wire length for grounding. Prepare the cable according to the specified dimensions, allowing for terminal lug depth and extra exposed conductor for crimping. Wrap one band of mastic around the cable jacket 1/4" (6mm) from the end, cut flush. Bend neutral wires back over the mastic and secure them to the cable jacket 4-6" (100-150mm) from the cut edge using vinyl tape or binding wire. Apply a second mastic band over the neutral wires and the first mastic, cut flush. Wrap two half-lapped layers of vinyl tape around the mastic seal, maintaining the 1/4" (6mm) dimension.

  2. Install Lug or Connector

    If using the included lug or connector, position it and crimp according to the manufacturer's directions. Do not crimp the last 1/4" to 3/8" of the connector. Remove excess oxide inhibitor and sharp crimp flashings. If a different lug is used and does not fit through the termination core, slide the termination onto the cable before installing the lug. Do not remove the core at this time.

  3. Clean Cable Insulation and Lug Barrel

    Wipe the cable insulation with an approved solvent, avoiding contact with the semi-conductive insulation shield. If abrasive is necessary, use only aluminum oxide abrasive (grit 120 or finer) on the insulation only, being careful not to reduce the cable insulation diameter below the kit's allowance.

  4. Install Termination - First Housing

    Wrap a band of gray silicone rubber tape around the base of the terminal lug to create a track-resistant moisture seal. The tape band should not exceed 2 layers if the barrel diameter is equal to or greater than the cable primary insulation. If the barrel diameter is smaller, use the tape strip to form a band equal to the insulation diameter. Apply a liberal coating of silicone grease to the edge of the semi-conductive insulation shield to fill the step at the cut-off. For the lower termination with a fold-down skirt, pull the loose end of the removable core through the top until it is flush with the bottom. Slide the termination body onto the cable, aligning it with the forward edge of the mastic seal. Carefully remove the core by unwinding counter-clockwise, ensuring the termination body, not the core, is butted against the mastic seal. Do not push or pull on the termination assembly during core removal.

  5. Install Termination - Second Housing

    Using the second housing, carefully pull the core down to within 1 coil of the bottom. Slide the terminator over the cable and carefully pull the core counterclockwise. Overlap the first terminator by 1-1/2" (40mm).

  6. Complete Termination Sealing

    Apply a thin film of silicone lubricant to the skirt and mastic seal area (do not lubricate skirt tabs). Carefully fold down the skirt over the mastic seal. Complete the lug area moisture seal using the remaining gray silicone rubber tape, overlapping the termination insulator by approximately 1" and extending the tape wrapping over a non-crimped region of the lug/connector barrel in a half-lap configuration. Confirm that the High-K step does not exceed 1.5".

  7. Connect Ground

    Twist the concentric neutral wires together and connect them to the system ground.

Frequently Asked Questions about ABB - Installation Products

How are Thomas and Betts products typically installed?

Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.

What accessories are available for Thomas and Betts products?

Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.

What environmental ratings do Thomas and Betts products have?

Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.

What communication protocols do Thomas and Betts products support?

Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.

What are the key features of Thomas and Betts products?

Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.

What are the main product lines offered by Thomas and Betts?

Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.

What technical support does Thomas and Betts offer?

Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.

What industries and applications are Thomas and Betts products used for?

Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.

What certifications and standards do Thomas and Betts products comply with?

Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.

What are the main product lines offered by Ocal?

Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.