ABB Installation Products R2T15J4-N0330-B2 Ranger2 Termination for 15KV outdoor application, cable insulation diameter 1.30 - 2.10…
UPC: 783786960064
Contact for Pricing
Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.
Overview
- 15 kV voltage rating for outdoor applications
- Accommodates cable insulation diameters from 1.30 to 2.10 inches
- Includes Aluminum 2-Hole Spade connector for #2-1250 kcmil conductors
- Compatible with Stranded/Compressed 500 kcmil, Compact/Solid 600 kcmil
- Plated Mild Steel Mounting Bracket for 1.10 - 1.50 inch (28-38mm) cable diameters
Specifications
Application | Cable Termination, Outdoor Application, 15kV |
Cable Type | Concentric Neutral Wire |
Color | Gray |
Conductor Size | 500 to 600 kcmil |
Earthing | Products Includes Their Own Grounding System |
Mounting | Product Need to have Cable Holder (not included) |
Number Of Terminals | (1) Single Phase |
Special Features | Silicone Rubber Housing. Lightweight, Compact Design. Pull-Down Tabs for Easy Installation. Thick Wall Construction |
Standard | IEEE 48 |
Type | Cable Termination - Outdoor - Ranger2 |
Voltage Rating | 15 kV |
Package Dimensions (L x W x H) | 0.01 IN x 0.01 IN x 0.01 IN |
Package Dimensions (L x W x H) | 0.0254 cm x 0.0254 cm x 0.0254 cm |
Package Weight (Imperial) | 1.0000 L |
Package Weight (Metric) | 0.4540 kg |

R2IT15J2-N0330-B3
Ranger2 Termination. Type - Indoor, 15kV, Cable Type - Concentric Neutral/Jacketed Concentric Neutral, Insulation Range - .84 inch - 1.38 inch, Connector Type - Aluminum 2-Hole Spade #2-1250 kcmil, Conductor Code - 330 -Stranded or Compressed 500, Compact or Solid 600. Cable Mounting Bracket - B3 - Stainless Steel - Size 1.45 inch - 1.95 inch.
R2T35J4-N0330
Ranger2 Termination for 35KV outdoor application, cable insulation diameter 1.30 - 2.10 for Concentric Neural and Jacketed Concentric Neutral Cable, includes Aluminum 2-Hole Spade connector for #2 through 1250 kcmil. Conductor Code 330 - 500 kcmil Stranded/Compressed or 600 kcmil Compact/Solid.
R2T15J2-N0310-B3
Ranger2 Termination for 15KV outdoor application, cable insulation diameter .84-1.38 inches for Concentric Neural and Jacketed Concentric Neutral Cable, Aluminum 2 Hole Spade #2-1250kcmil, Stranded or Compressed 400 /Compact or Solid 500. Stainless Steel Mounting Bracket 1.45 inch - 1.95 inch (37-50mm)
R2T28M2T0240-B1
Ranger2 Termination, Outdoor, 25/28kV, Cable Type - Tape Shield/Wire Shield/UniSheild, Insulation Range .84-1.38 inch (21-35mm), Connector Type - Universal Aluminum Barrel for Aluminum or Copper with Copper Wire Lead #2-4/0. Conductor Code 240 - Stranded/Compressed 1/0 or Compact/Solid 2/0. Cable Mounting Bracket Size .80-1.25 inch (20-32mm), Bracket Material - Stainless Steel
R2T28J2T0240-B1
Ranger2 Termination, Outdoor, 25/28kV, Cable Type - Concentric Neutral/Jacketed Concentric Neutral Cable, Insulation Range .84-1.38 inch (21-35mm), Connector Type - Universal Aluminum Barrel for Aluminum or Copper with Copper Wire Lead #2-4/0. Conductor Code 240 - Stranded/Compressed 1/0 or Compact/Solid 2/0. Cable Mounting Bracket Size .80-1.25 inch (20-32mm), Bracket Material - Stainless Steel
R2T15M4-N2440
Outdoor, Ranger2 Termination, 15kV, Cable Type Tape Shield/Wire Shield/Unishield, Insulation Range 1.30 to 2.10 inch (33-53mm). Connector Type Copper 2-Hole Spade #2-1250 kcmil. Conductor Size 1250 Compressed/Stranded.
R2T15J2N2300
Ranger 2 Terminator, Outdoor, 15kV, Concentric Neutral/Jacketed Concentric Neutral Cable Type, Insulation Range .84 -1.38 inch (21-35mm) Connector Type - Copper 2-Hole Spade #2-1250 kcmil. 350 Stranded/Compressed or 400 Compact/Solid.
R2T15J2-N2270
15kV, Ranger2 Cable Termination, Outdoor, Cable Type - Concentric Neutral/Jacketed Concentric Neutral, Insulation Range - .84-1.38 inch (21-35mm), Connector Type - N2 - Copper 2-Hole spade #2-1250 kcmil, Conductor Code 270 - 4/0 Strandeed/Compressed or 250 Compact/Solid.Frequently Asked Questions
What is the voltage rating of this Ranger2 termination?
The ABB Ranger2 termination is rated for 15 kV applications.
What cable insulation diameters does this termination support?
This termination supports cable insulation diameters ranging from 1.30 to 2.10 inches.
What conductor sizes are compatible with the included spade connector?
The Aluminum 2-Hole Spade connector is compatible with conductor sizes from #2 AWG up to 1250 kcmil.
What types of 600 kcmil conductors can be used?
The connector is suitable for Compact 600 kcmil or Solid 600 kcmil conductors.
What is the size range for the mounting bracket?
The Plated Mild Steel Mounting Bracket is designed for cable diameters between 1.10 and 1.50 inches (28-38mm).
What type of cables is this termination designed for?
This termination is designed for Concentric Neutral and Jacketed Concentric Neutral cables.
How to Install the 15kV Ranger 2 Cable Termination (R2T15J4)
This guide provides detailed instructions for installing the 15kV Ranger 2 Cable Termination on concentric and jacketed concentric neutral cables for indoor/outdoor applications. It covers cable preparation, lug installation, cleaning, and the final termination installation.
Estimated time: 2h
Tools needed:
Wire strippers, Crimping tool, Vinyl tape, Approved solvent, Aluminum oxide abrasive (grit 120 or finer), Gloves
Supplies needed:
Silicone Rubber Termination, Lubricant, Grey Silicone Rubber Tape, Sealing Mastic, Terminal lug or connector, Silicone grease, Binding wire (optional)
- Prepare Cable for Termination
DANGER: All apparatus must be de-energized during installation. Verify the cable size fits within the kit's range using the Termination Selection Chart. Train the cable into position and cut to the required length, allowing sufficient neutral wire length for grounding. Prepare the cable using the dimensions shown, accounting for terminal lug depth and additional exposed conductor distance for aluminum lug crimping. Apply one band of sealing mastic 1/4" (6mm) from the jacket end, stretching 50%, and cut flush. Bend neutral wires back over the mastic, press them in, and secure to the cable jacket 4-6" (100-150mm) from the cut edge with vinyl tape or binding wire. Apply a second mastic band over the neutral wires, stretching 50%, and cut flush. Wrap two half-lapped layers of vinyl tape around the mastic seal, maintaining the 1/4" (6mm) dimension.
- Install Lug or Connector
If using lugs that do not fit through the termination core, clean the insulation and slide the termination onto the cable before installing the lug; do not remove the core at this time. Position the connector or lug and crimp it according to its specific directions. Do not crimp the last 1/4" to 3/8" of the connector. After crimping, remove any excess oxide inhibitor and sharp crimp flashings.
- Clean Cable Insulation and Lug Barrel
Wipe the cable insulation with an approved solvent, ensuring the solvent does not touch the semi-con insulation shield. If an abrasive is necessary, use it only on the insulation and not on the semi-con insulation shield. Use only aluminum oxide abrasive, grit 120 or finer, taking care not to reduce the cable insulation diameter below the kit's allowed range.
- Install the Termination Body
Create a track-resistant moisture seal between the termination insulator and the lug/connector by wrapping a band of gray silicone rubber tape around the base of the terminal lug. If the barrel diameter is smaller than the cable primary insulation, build up the tape band to the insulation diameter. Cover the edge of the semi-con insulation shield with a liberal coating of silicone grease to fill the step at the semi-con cut-off. For lower terminations with a fold-down skirt, pull the loose end of the removable core through the top until it is flush with the bottom. Slide the termination body onto the cable, aligning it with the forward edge of the mastic seal. Carefully remove the core by unwinding it counter-clockwise, ensuring the termination body is butted against the mastic seal. Do not push or pull the assembly during core removal. Apply a thin film of silicone lubricant to the skirt and mastic seal area (avoiding skirt tabs), then carefully fold down the skirt over the mastic seal. Complete the lug area moisture seal using the remaining gray silicone rubber tape, overlapping the insulator by approximately 1" and extending over a non-crimped region of the lug/connector barrel with a half-lap configuration. Twist concentric neutral wires together and connect to system ground. Confirm that the High-K step does not exceed 1.5".
Frequently Asked Questions about ABB - Installation Products
How are Thomas and Betts products typically installed?
Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.
What accessories are available for Thomas and Betts products?
Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.
What environmental ratings do Thomas and Betts products have?
Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.
What communication protocols do Thomas and Betts products support?
Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.
What are the key features of Thomas and Betts products?
Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.
What are the main product lines offered by Thomas and Betts?
Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.
What technical support does Thomas and Betts offer?
Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.
What industries and applications are Thomas and Betts products used for?
Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.
What certifications and standards do Thomas and Betts products comply with?
Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.
What are the main product lines offered by Ocal?
Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.