
ABB Installation Products R2T15M4N2330-B3 Ranger2 Termination. Type - Outdoor, 15kV, Cable Type - Tape Shield/Wire Shield/…
UPC: 075114145367
Contact for Pricing
Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.
Overview
- 15kV voltage rating with 9.5kV max design voltage to ground
- Accommodates 1.30"–2.10" insulation diameter cables (#2 AWG–1250 kcmil)
- Supports stranded/compressed 500 kcmil and solid 600 kcmil conductors
- Non-tracking silicone housing with four sheds for outdoor service
- Stainless steel B3 bracket for cable diameters 1.45"–1.95"
Specifications
Application | Cable Termination, Outdoor Application, 15kV |
Cable Type | Copper Tape Shielded Wire |
Color | Gray |
Conductor Size | 500 to 600 kcmil |
Connection Type | 2-Hole Spade |
Earthing | Products Includes Their Own Grounding System |
Material | Copper |
Mounting | Product Need to have Cable Holder (not included) |
Mounting Type | B3 - Stainless Steel |
Number Of Terminals | (1) Single Phase |
Series | Ranger2 |
Size | 1.30 inch - 2.10 inch |
Special Features | Silicone Rubber Housing. Lightweight, Compact Design. Pull-Down Tabs for Easy Installation. Thick Wall Construction |
Standard | IEEE 48 |
Type | Cable Termination - Outdoor - Ranger2 |
Voltage Rating | 15 kV |
Package Dimensions (L x W x H) | 0.01 IN x 0.01 IN x 0.01 IN |
Package Dimensions (L x W x H) | 0.0254 cm x 0.0254 cm x 0.0254 cm |
Package Weight (Imperial) | 1.0000 L |
Package Weight (Metric) | 0.4540 kg |

R2T35M4N2330
Ranger2 Termination for 35KV outdoor application, cable insulation diameter .84 - 1.38 inches for Cable Type - Tape Shield, Wire Shield, and Unshielded Cable, Copper 2-Hole Spade #2-1250kcmil, Stranded or Compressed 500/ Compact or Solid 600 .
R2T15M4-N2380-B3
Ranger2 Termination for 15KV outdoor application, cable insulation diameter 1.30 - 2.10 inches for Cable Type - Tape Shield/Wire Shield/Unshield Cable, Copper 2-Hole Spade #2-1250kcmil, Stranded or Compressed 750 /Compact or Solid 900. - Cable Mounting Bracket - Stainless Steel, 1.45 inch - 1.95 inch (37-50mm)
R2T15M4-N0380-B3
Ranger2 Termination for 15KV outdoor application, cable insulation diameter 1.30 - 2.10 inches for Cable Type - Tape Shield/Wire Shield/ UniShield. Includes Aluminum 2-Hole Spade connector for #2-1250 kcmil, Stranded or Compressed 750 /Compact or Solid 900 - Cable Mounting Bracket - Stainless Steel, 1.45 inch - 1.95 inch (37-50mm)
R2T15M4-N2350-B3
15 kv, Cable Terminator Ranger2, Outdoor, Cable Type - Tape Shield/Wire Shield/UniShield, Insulation Range 4 - 1.30 inch to 2.10 inch (33 mm to 53 mm), Connector Type N2 - Copper 2-Hole Spade #2-1250 kcmil, Conductor Code 350 - Compressed 600 or Compact 700, Cable Mounting Bracket B3 - Material Stainless Steel - Size - 1.45 inch to 1.95 inch (37mm - 50mm)
R2T15M4-N0380
Ranger2 Termination for 15KV outdoor application, cable insulation diameter 1.30 - 2.10 inches for Cable Type - Tape Shield/Wire Shield/ UniShield. Includes Aluminum 2-Hole Spade connector for #2-1250 kcmil, Stranded or Compressed 750 /Compact or Solid 900
R2T15M2N2330
Ranger2 Termination. Type - Outdoor, 15kV, Cable Type - Tape Shield/Wire Shield/ Unshield, Insulation Range - .84 inch - 1.38 inch, Connector Type - Copper 2-Hole Spade #2-1250 kcmil, Conductor Code - 330 -Stranded or Compressed 500 Compact or Solid 600.
R2T15M2N2310
Ranger2 Termination. Type - Outdoor, 15kV, Cable Type - Tape Shield/Wire Shield/ Unshield, Insulation Range - .84 inch - 1.38 inch, Connector Type - Copper 2-Hole Spade #2-1250 kcmil, Conductor Code - 310 -Stranded or Compressed 400 Compact or Solid 500.
R2T15M2-T0250
Ranger2 Termination for 15KV outdoor application, cable insulation diameter .84 - 1.38 inches for Tape Shield, Wire Shield, and Unshielded Cable, includes Universal Aluminum Barrel For AL or CU Conductor w/copper wire leadFrequently Asked Questions
What cable sizes does the R2T15 termination support?
The R2T15 termination supports cable insulation diameters from 0.64 in (16 mm) to 2.10 in (53 mm), covering #2 AWG through 1250 kcmil.
What power system frequency does the R2T15 support?
The R2T15 termination supports a power system frequency range of 48 to 62 Hz.
What is the creepage distance of the R2T15 termination?
The creepage distance for the R2T15 termination is 15.0 inches (381 mm).
How many sheds does the 15kV outdoor model have?
The 15kV outdoor model of the R2T15 termination has four sheds.
What is the maximum altitude for R2T15 installation?
The R2T15 termination can be installed at a maximum altitude of 3300 feet (1005 m).
What is the operating ambient temperature range?
The R2T15 termination operates within an ambient temperature range of -22 to +149 °F (-30 to +65 °C).
What is the maximum design voltage to ground?
The maximum design voltage to ground for the R2T15 termination is 9.5 kV.
What is the voltage rating of the R2T15 termination?
The R2T15 termination has a voltage rating of 15 kV.
What cable types are compatible with R2T15 terminations?
R2T15 units accommodate popular XLP and EPR cable types and shield constructions.
Where can I find installation instructions for R2T15?
Installation instructions are IS-1134 for R2T15J, IS-1135 for R2T15M, and IS-1136 for R2T15L.
How to Install the R2T15M4 Silicone Rubber Termination on Tape Shielded Cables
This guide provides detailed instructions for installing the R2T15M4 Ranger 2 Shrink-fit Silicone Rubber Termination on 15kV tape shielded cables, covering cable preparation, ground braid installation, lug connection, and termination placement.
Estimated time: 1h 30m
Tools needed:
Crimping tool, Wire strippers, Soldering iron, Cable preparation knife, Solvent applicator pads, Aluminum oxide abrasive (grit 120 or finer, if needed)
Supplies needed:
R2T15M4 Silicone Rubber Termination kit (includes termination, lubricant, gray silicone rubber tape, constant force spring, preformed ground braid, sealing mastic, copper foil tape, gloves), Terminal lug or connector (compatible with cable), Vinyl electrical tape, Approved solvent, Semi-conductive rubber tape (e.g., Scotcht No. 13, if cable has cloth or paper semi-con shield)
- De-energize and Prepare Cable
DANGER: De-energize all apparatus before beginning installation. Failure to do so may result in serious injury or death. Verify cable size fits within the termination kit's insulation range. Train the cable into position and cut it to the required length. Prepare the cable by removing the jacket, tape shield, and semi-conductive layer according to the specified dimensions, allowing for terminal lug depth and aluminum lug growth allowance. Secure the edge of the tape shield with a single wrap of the supplied copper foil tape.
- Install Ground Braid
Wrap one band of sealing mastic around the cable jacket 1/4 inch (6mm) from the jacket end, stretching it to 50%. Position the preformed ground braid with its short tail over the tape shield and the solder block centered over the mastic. Secure the ground braid to the cable jacket with vinyl tape and press the solder block into the mastic. Apply a second mastic band over the solder block and previous mastic, maintaining the 1/4 inch (6mm) dimension. Wrap two half-lapped layers of vinyl tape around the mastic seal. Wrap the ground braid around the cable tape shield once, trim excess, and secure it with the constant force spring, wrapping in the same direction. Cinch the spring and secure it with two wraps of vinyl tape. If the cable has a cloth or paper semi-conductive shield, overwrap it with one half-lapped layer of highly stretched semi-conductive rubber tape.
- Install Terminal Lug or Connector
Ensure the termination assembly can fit over the selected lug. If the lug will not fit through the termination core, clean the cable insulation and slide the termination onto the cable before installing the lug (do not remove the core at this time). Position the terminal lug or connector and crimp it according to the manufacturer's instructions, leaving the last 3/8 to 1/2 inch uncrimped. Remove any excess oxide inhibitor and sharp crimp flashings or edges following crimping.
- Clean Cable Insulation and Lug Barrel
Wipe the cable insulation with an approved solvent, ensuring no solvent touches the semi-conductive insulation shield. If abrasive cleaning is necessary, use only aluminum oxide abrasive (grit 120 or finer) on the insulation, avoiding the semi-conductive shield, and be careful not to reduce the cable insulation diameter below that allowed by the kit.
- Install and Seal the Termination
Create a track-resistant moisture seal by wrapping a band of gray silicone rubber electrical tape around the base of the terminal lug. Adjust the tape layers (max 2) or build up the band to match the insulation diameter if the lug barrel is smaller than the cable primary insulation. Liberally coat the edge of the semi-conductive insulation shield with silicone grease to fill the step. Pull the loose end of the removable core through the top of the termination until it is flush with the bottom. Slide the termination body onto the cable, aligning it with the forward edge of the mastic seal. Carefully remove the core by unwinding it counter-clockwise, ensuring the termination body (not the core) butts against the leading edge of the mastic seal. Continue removing the core without pushing or pulling the termination assembly. Apply a thin film of silicone lubricant to the skirt and mastic seal area (avoiding skirt tabs) and carefully fold down the skirt over the mastic seal. Complete the lug area moisture seal with the remaining gray silicone rubber electrical tape, overlapping the termination insulator by approximately 1 inch and extending over a non-crimped region of the lug/connector barrel with a half-lap configuration. Connect the ground braid to the system ground. Finally, confirm that the High-K step does not exceed 1.5 inches.
Frequently Asked Questions about ABB - Installation Products
How are Thomas and Betts products typically installed?
Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.
What accessories are available for Thomas and Betts products?
Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.
What environmental ratings do Thomas and Betts products have?
Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.
What communication protocols do Thomas and Betts products support?
Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.
What are the key features of Thomas and Betts products?
Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.
What are the main product lines offered by Thomas and Betts?
Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.
What technical support does Thomas and Betts offer?
Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.
What industries and applications are Thomas and Betts products used for?
Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.
What certifications and standards do Thomas and Betts products comply with?
Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.
What are the main product lines offered by Ocal?
Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.