ABB Installation Products R2T15M2-N2300 Ranger2 Termination. Type - Outdoor, 15kV, Cable Type - Tape Shield/Wire Shield/…
UPC: 075114185431
Contact for Pricing
Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.
Overview
- 15kV outdoor termination for medium-voltage power distribution
- Accommodates tape shield, wire shield, and unshielded cables (0.84-1.38" insulation)
- Copper 2-hole spade connector rated for 300-400 kcmil conductors
- Non-tracking silicone housing with superior weathering and memory
- Four-shed design for maximum creepage and strike distances
- Field-removable center core for easy installation
- Free-hanging or bracket-mounted installation options
- Operates in ambient temperatures from -22°F to +149°F (-30°C to +65°C)
- Lightning impulse withstand: 110 kV crest
- Max altitude: 3,300 feet (1,005 meters)
Specifications
Application | Cable Termination, Outdoor Application, 15kV |
Cable Type | Copper Tape Shielded Wire |
Color | Gray |
Conductor Size | 350 to 400 kcmil |
Connection Type | 2-Hole Spade |
Earthing | Products Includes Their Own Grounding System |
Material | Copper |
Mounting | Product Need to have Cable Holder (not included) |
Mounting Type | Outdoor |
Number Of Terminals | (1) Single Phase |
Series | Ranger2 |
Size | 0.84 inch - 1.38 inch |
Special Features | Silicone Rubber Housing. Lightweight, Compact Design. Pull-Down Tabs for Easy Installation. Thick Wall Construction |
Standard | IEEE 48 |
Type | Cable Termination - Outdoor - Ranger2 |
Voltage Rating | 15 kV |
Voltage Rating | 15kV |
Package Dimensions (L x W x H) | 0.01 IN x 0.01 IN x 0.01 IN |
Package Dimensions (L x W x H) | 0.0254 cm x 0.0254 cm x 0.0254 cm |
Package Weight (Imperial) | 1.0000 L |
Package Weight (Metric) | 0.4540 kg |

R2T15J2N2300
Ranger 2 Terminator, Outdoor, 15kV, Concentric Neutral/Jacketed Concentric Neutral Cable Type, Insulation Range .84 -1.38 inch (21-35mm) Connector Type - Copper 2-Hole Spade #2-1250 kcmil. 350 Stranded/Compressed or 400 Compact/Solid.
R2T15M2-N0330
Ranger2 Termination for 15KV outdoor application, cable insulation diameter 0.84 - 1.38 inches for Cable Type - Tape Shield/Wire Shield/ UniShield. Includes Aluminum 2-Hole Spade connector for #2-1250 kcmil, Stranded or Compressed 500 /Compact or Solid 600
R2T15M2-N0330-B2
Ranger2 Termination for 15KV outdoor application, cable insulation diameter 0.84 - 1.38 inches for Cable Type - Tape Shield/Wire Shield/ UniShield. Includes Aluminum 2-Hole Spade connector for #2-1250 kcmil, Stranded or Compressed 500 /Compact or Solid 600, Stainless Steel Mounting Bracket 1.10 inch - 1.50 inch
R2T15M2-N0280
Ranger2 Termination for 15KV outdoor application, cable insulation diameter 0.84 - 1.38 inches for Cable Type - Tape Shield/Wire Shield/ UniShield. Includes Aluminum 2-Hole Spade connector for #2-1250 kcmil, Stranded or Compressed 250 /Compact or Solid 300
R2T15M2-N0310
Ranger2 Termination for 15KV outdoor application, cable insulation diameter 0.84 - 1.38 inches for Cable Type - Tape Shield/Wire Shield/ UniShield. Includes Aluminum 2-Hole Spade connector for #2-1250 kcmil, Stranded or Compressed 400 /Compact or Solid 500
R2T15M2-N0300
Ranger2 Termination. Type - Outdoor, 15kV, Cable Type - Tape Shield/Wire Shield/ Unshield, Insulation Range - .84 inch - 1.38 inch, Connector Type - Aluminum 2-Hole Spade #2-1250 kcmil, Conductor Code - 300 -Stranded or Compressed 350 Compact or Solid 400.
R2T15M2-N0270
Ranger2 Termination for 15KV outdoor application, cable insulation diameter 0.84 - 1.38 inches for Cable Type - Tape Shield/Wire Shield/ UniShield. Includes Aluminum 2-Hole Spade connector for #2-1250 kcmil, Stranded or Compressed 4/0 /Compact or Solid 250
R2T15M1T0270
Ranger2 Termination. Type - Outdoor, 15kV, Cable Type - Tape Shield/Wire Shield/ Unshield, Insulation Range - .64 inch - 1.12 inch, Connector Type - Universal Aluminum Barrel for AL or CU Condutor with Copper Wire Lead #2-4/0, Conductor Code - 270 -Stranded or Compressed 4/0 Compact or Solid 250.Frequently Asked Questions
What cable sizes does the R2T15 termination cover?
The R2T15 termination covers cable insulation diameters from 0.64 in (16 mm) to 2.10 in (53 mm), accommodating #2 AWG through 1250 kcmil cables.
What is the voltage rating of the R2T15 termination?
The R2T15 termination has a voltage rating of 15 kV. Its maximum design voltage to ground is 9.5 kV.
What is the operating temperature range for R2T15?
The R2T15 termination operates within an ambient temperature range of -22 to +149 °F (-30 to +65 °C).
Where can I find installation instructions for R2T15?
Installation instructions are IS-1134 for R2T15J, IS-1135 for R2T15M, and IS-1136 for R2T15L.
What is the operating temperature range for R2T15?
The R2T15 termination operates within an ambient temperature range of -22 to +149 °F (-30 to +65 °C).
What is the voltage rating of the R2T15 termination?
The R2T15 termination has a voltage rating of 15 kV. Its maximum design voltage to ground is 9.5 kV.
Where can I find installation instructions for R2T15?
Installation instructions are IS-1134 for R2T15J, IS-1135 for R2T15M, and IS-1136 for R2T15L.
What cable sizes does the R2T15 termination cover?
The R2T15 termination covers cable insulation diameters from 0.64 in (16 mm) to 2.10 in (53 mm), accommodating #2 AWG through 1250 kcmil cables.
What is the voltage rating of the R2T15 termination?
The R2T15 termination has a voltage rating of 15 kV. Its maximum design voltage to ground is 9.5 kV.
What is the operating temperature range for R2T15?
The R2T15 termination operates within an ambient temperature range of -22 to +149 °F (-30 to +65 °C).
How to Install the 15kV & 28kV Ranger 2 Shrink Fit Silicone Rubber Termination
This guide provides step-by-step instructions for the safe and proper installation of the 15kV & 28kV Ranger 2 Shrink Fit Silicone Rubber Termination on tape shield, wire shield, or UniShield® cables, including cable preparation, ground braid installation, and termination sealing.
Estimated time: 1h 30m
Tools needed:
Crimping tool, Soldering iron, Wire strippers, Measuring tape or ruler, Utility knife or cable preparation tool, Aluminum oxide abrasive (grit 120 or finer), Solvent saturated pads or clean cloths
Supplies needed:
R2T15/28M Shrink Fit Silicone Rubber Termination Kit (includes: Silicone Rubber Termination, Lubricant, Gray Silicone Rubber Tape, Constant Force Spring, Preformed Ground Braid, Sealing Mastic, Copper Foil Tape, Gloves), Vinyl electrical tape, Approved electrical solvent, Terminal lug or connector, Scotch® No. 13 semi-conductive rubber tape (optional, for specific cable types), Cable support bracket (optional)
- Perform Pre-Installation Safety Checks and Preparations
DANGER: Ensure all apparatus is de-energized during installation or removal of parts. Do not touch or move energized products in the work area. Inspect the kit contents to ensure they are complete and undamaged. Verify all components for proper fit with the cable and/or mating products. Read the entire installation instructions before starting and have all required tools at hand, maintaining cleanliness throughout the procedure.
- Prepare the Cable
Train the cable into position, cut to the required length, and prepare the cable end according to the specific cable type (tape shield, wire shield, or UniShield®) and the dimensions provided in the Termination Selection Chart and Table 1. Allow for the depth of the terminal lug and any growth allowance for aluminum lugs. For tape shield cables, prevent unrolling with copper foil tape. For wire shield cables, bend shield wires back. For UniShield® cables, install and remove the constant force spring to aid jacket removal and bend shield wires back.
- Install the Ground Braid
Carefully wrap one band of mastic (using 50% stretch) around the cable jacket 1/4" (6mm) from the jacket end. Position the preformed ground braid with the short tail over the shield and the solder block centered over the mastic strip. Secure the ground braid to the cable jacket using vinyl tape and press the solder block into the mastic. Apply a second mastic band over the solder block and the first mastic, then wrap two half-lapped layers of vinyl tape over the mastic seal. Wrap the ground braid around the cable shield one complete wrap, trim excess, and secure it with the constant force spring, cinching it tightly and securing with two wraps of vinyl tape. SPECIAL NOTE: For cloth or paper semi-conductive insulation shields, overwrap with one half-lapped layer of highly stretched semi-conductive rubber tape such as Scotch® No. 13.
- Install the Lug or Connector
Check to ensure the termination assembly fits over the selected lug. If the lug will not fit through the termination core, clean the insulation and slide the termination onto the cable before installing the lug. Do not remove the core at this time. Position the connector/lug and crimp it according to the manufacturer's directions, ensuring not to crimp the last 3/8" to 1/2" of the connector. Remove any excess oxide inhibitor and all sharp crimp flashings and edges following crimping.
- Clean Cable Insulation and Lug Barrel
Wipe the cable insulation with an approved solvent, ensuring the solvent does not touch the semi-conductive insulation shield. If abrasive cleaning is necessary, use only aluminum oxide abrasive (grit 120 or finer) on the insulation only, avoiding the semi-conductive shield. Be careful not to reduce the cable insulation diameter below that allowed by the kit.
- Install the Termination Body
Create a track-resistant moisture seal between the termination insulator and the lug/connector by wrapping a band of gray silicone rubber electrical tape around the base of the terminal lug. Cover the edge of the semi-conductive insulation shield with a liberal coating of silicone grease to fill the step. Pull the loose end of the removable core through the top of the termination until the core is flush with the bottom of the termination. Slide the termination body onto the cable, aligning it with the forward edge of the mastic seal. Carefully begin to remove the core by unwinding it counter-clockwise, starting with the loose end. Make sure the termination body, not the core, is butted up to the leading edge of the mastic seal. Continue to remove the core, ensuring not to push or pull on the termination assembly while doing so.
- Complete Termination Sealing and Grounding
Apply a thin film of silicone lubricant to the skirt and mastic seal area, ensuring not to lubricate the skirt tabs. Carefully fold down the skirt over the mastic seal. Complete the lug area moisture seal using the remaining gray silicone rubber electrical tape, overlapping the termination insulator by approximately 1" and extending the tape wrapping over a non-crimped region of the lug/connector barrel with a half-lap configuration. Connect the ground braid to the system ground. Confirm that the High-K step does not exceed 1.5".
Frequently Asked Questions about ABB - Installation Products
How are Thomas and Betts products typically installed?
Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.
What accessories are available for Thomas and Betts products?
Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.
What environmental ratings do Thomas and Betts products have?
Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.
What communication protocols do Thomas and Betts products support?
Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.
What are the key features of Thomas and Betts products?
Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.
What are the main product lines offered by Thomas and Betts?
Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.
What technical support does Thomas and Betts offer?
Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.
What industries and applications are Thomas and Betts products used for?
Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.
What certifications and standards do Thomas and Betts products comply with?
Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.
What are the main product lines offered by Ocal?
Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.