ABB - Installation Products R2T15J1-N0220 - Ranger2 Termination. Type - Outdoor, 15kV, Cable Type - Concentric Neutral/Jacketed Concentric Neutral, Insulation Range - .64 inch - 1.12 inch, Connector Type - Aluminum 2-Hole Spade #2-1250 kcmil, Conductor Code - 220 -Stranded or Compressed #2 Compact or Solid #1.

ABB Installation Products R2T15J1-N0220 Ranger2 Termination. Type - Outdoor, 15kV, Cable Type - Concentric Neutral/Jacketed…

UPC: 075114130592


Documents & Media
Installation InstructionsSpecification SheetManufacturer Product Website

Contact for Pricing

Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.

Overview

The ABB Ranger2 Outdoor 15kV Termination (SKU R2T15J1-N0220) is a high-reliability medium-voltage cable termination designed for outdoor applications in utility, industrial, and commercial power distribution systems. This termination leverages shrink-fit technology and Elastimold’s pull-down jacket seal feature to deliver a versatile solution covering a wide range of cable types and sizes with minimal model variation. The termination accommodates insulation diameters from 0.64 inches (16 mm) to 2.10 inches (53 mm) and conductor sizes from #2 AWG to 1250 kcmil, supporting both stranded/compressed and solid conductors. Compatible cable types include XLP and EPR with concentric neutral or jacketed concentric neutral shielding. The termination features a non-tracking silicone housing with superior weathering characteristics and memory, ensuring long-term performance in field conditions. The shrink-fit housing simplifies installation with common procedures and cable preparation dimensions, while the field-removable center core enhances ease of use. The design includes four sheds for the 15kV outdoor model, optimizing creepage and strike distances for reliable operation. Optional insulating silicone sleeves are available for applications requiring additional creepage or wildlife protection. The aluminum 2-hole spade connector (#2-1250 kcmil) provides a secure, high-conductivity interface for medium-voltage power systems. The termination installs efficiently in restricted spaces and permits free-hanging applications where required. Optional accessories include connectors with copper stems, one-hole spade connectors, and support brackets in sizes ranging from 0.80 inches to 2.40 inches outer diameter. Ideal for utility substations, renewable energy installations, industrial facilities, and commercial power infrastructure, the Ranger2 Outdoor 15kV Termination ensures safe, efficient, and durable cable termination in outdoor environments.
  • 15 kV voltage rating with 9.5 kV max design voltage to ground
  • Accommodates insulation diameters from 0.64" to 2.10" and conductors from #2 AWG to 1250 kcmil
  • Shrink-fit housing with pull-down jacket seal for simplified installation
  • Non-tracking silicone housing with superior weathering and memory characteristics
  • Four sheds for optimized creepage and strike distances in outdoor environments

Specifications

Application
Cable Termination, Outdoor Application, 15kV
Cable Type
Concentric Neutral Wire
Color
Gray
Conductor Size
#2 STR AWG , #2 COMPR AWG , #1 SOL AWG , #1 COMPT AWG
Earthing
Products Includes Their Own Grounding System
Mounting
Product Need to have Cable Holder (not included)
Number Of Terminals
(1) Single Phase
Special Features
Silicone Rubber Housing. Lightweight, Compact Design. Pull-Down Tabs for Easy Installation. Thick Wall Construction
Standard
IEEE 48
Type
Cable Termination - Outdoor - Ranger2
Voltage Rating
15 kV
Package Dimensions (L x W x H)
0.01 IN x 0.01 IN x 0.01 IN
Package Dimensions (L x W x H)
0.0254 cm x 0.0254 cm x 0.0254 cm
Package Weight (Imperial)
1.0000 L
Package Weight (Metric)
0.4540 kg
15kV, Single Piece Terminator (Class 1), Two Hole Spade Lug. Power Cable Termination, Conductor Size - #2 Stranded/Compressed or #1 Compact/Solid, Use for Insulation Diameter Range from .640 to 1.070 inches.

PCT11220-3

15kV, Single Piece Terminator (Class 1), Two Hole Spade Lug. Power Cable Termination, Conductor Size - #2 Stranded/Compressed or #1 Compact/Solid, Use for Insulation Diameter Range from .640 to 1.070 inches.
Ranger2 Termination. Type - Outdoor, 15kV, Cable Type - Concentric Neutral/Jacketed Concentric Neutral, Insulation Range - .64 inch - 1.12 inch, Connector Type - Aluminum 2-Hole Spade #2-1250 kcmil, Conductor Code - 210 -Stranded or Compressed N/A Compact or Solid #2.

R2T15J1-N0210

Ranger2 Termination. Type - Outdoor, 15kV, Cable Type - Concentric Neutral/Jacketed Concentric Neutral, Insulation Range - .64 inch - 1.12 inch, Connector Type - Aluminum 2-Hole Spade #2-1250 kcmil, Conductor Code - 210 -Stranded or Compressed N/A Compact or Solid #2.
Ranger2 Termination for 15KV outdoor application, cable insulation diameter .64 - 1.12 inches for Concentric Neural and Jacketed Concentric Neutral Cable, includes Aluminum 1-Hole Spade connector for #2 to 500 kcmil. 4/0 Stranded or 250 kcmil Solid

R2T15J1-H0270

Ranger2 Termination for 15KV outdoor application, cable insulation diameter .64 - 1.12 inches for Concentric Neural and Jacketed Concentric Neutral Cable, includes Aluminum 1-Hole Spade connector for #2 to 500 kcmil. 4/0 Stranded or 250 kcmil Solid
Outdoor Ranger2 Cable Termination. 15kV, Cable Type - Concentric Neutral/Jacketed Concentric Neutral. Insulation Range - .64 inch - 1.12 inch. Aluminum 1-Hole Spade #2-500 kcmil, Conductor 1/0 Stranded/Compressed or 2/0 Compact/Solid

R2T15J1-H0240

Outdoor Ranger2 Cable Termination. 15kV, Cable Type - Concentric Neutral/Jacketed Concentric Neutral. Insulation Range - .64 inch - 1.12 inch. Aluminum 1-Hole Spade #2-500 kcmil, Conductor 1/0 Stranded/Compressed or 2/0 Compact/Solid
Ranger2 Termination for 15KV indoor application, cable insulation diameter 1.30 -2.10 inches for Cable Type - Tape Shield, Wire Shield, and Unshielded Cable, includes Aluminum 2-Hole Spade connector for #2-1250 kcmil, Stranded or Compressed 500 /Compact or Solid 600

R2IT15M4N0330

Ranger2 Termination for 15KV indoor application, cable insulation diameter 1.30 -2.10 inches for Cable Type - Tape Shield, Wire Shield, and Unshielded Cable, includes Aluminum 2-Hole Spade connector for #2-1250 kcmil, Stranded or Compressed 500 /Compact or Solid 600
Ranger2 Termination for 15KV outdoor application, cable insulation diameter .64 - 1.12 inches for Concentric Neural and Jacketed Concentric Neutral Cable, includes Aluminum 1-Hole Spade connector for #2 to 500 kcmil. #2 Stranded to #1 Solid

R2T15J1-H0220

Ranger2 Termination for 15KV outdoor application, cable insulation diameter .64 - 1.12 inches for Concentric Neural and Jacketed Concentric Neutral Cable, includes Aluminum 1-Hole Spade connector for #2 to 500 kcmil. #2 Stranded to #1 Solid
Ranger2 Termination. Type - Indoor, 15kV, Cable Type - Tape Shield/Wire Shield/ Unshield, Insulation Range - 1.30 inch - 2.10 inch, Connector Type - Aluminum 2-Hole Spade #2-1250 kcmil, Conductor Code - 440 -Stranded or Compressed 1250 Compact or Solid N/A.

R2IT15M4N0440

Ranger2 Termination. Type - Indoor, 15kV, Cable Type - Tape Shield/Wire Shield/ Unshield, Insulation Range - 1.30 inch - 2.10 inch, Connector Type - Aluminum 2-Hole Spade #2-1250 kcmil, Conductor Code - 440 -Stranded or Compressed 1250 Compact or Solid N/A.
Indoor Ranger2 Cable Termination. 15kV, Cable Type - Tape Shield/Wire Shield/UniShield. Insulation Range - 1.30 inch - 2.10 inch. Copper 2-Hole Spade #2-1250 kcmil, Conductor 1250 Stranded/Compressed

R2IT15M4-N2440

Indoor Ranger2 Cable Termination. 15kV, Cable Type - Tape Shield/Wire Shield/UniShield. Insulation Range - 1.30 inch - 2.10 inch. Copper 2-Hole Spade #2-1250 kcmil, Conductor 1250 Stranded/Compressed

Frequently Asked Questions

What cable insulation diameters are supported?

The termination supports insulation diameters from 0.64 inches (16 mm) to 2.10 inches (53 mm).

What is the ambient operating temperature range?

The ambient temperature range for operation is -22 to +149 °F (-30 to +65 °C).

How many sheds does the 15kV outdoor model have?

The 15kV outdoor model features four sheds.

What is the IEEE classification for this outdoor termination?

The IEEE classification for this outdoor termination is Class 1A.

What are the available mounting options?

The termination can be free hanging or mounted with an optional support bracket.

What is the maximum altitude for installation?

The maximum altitude for installation is 3300 feet (1005 m).

What is the maximum design voltage to ground?

The maximum design voltage to ground for this termination is 9.5 kV.

What is the voltage rating of the R2T15 termination?

The R2T15 termination has a voltage rating of 15 kV.

What cable types are compatible with this termination?

The units accommodate popular XLP and EPR cable types and various shield constructions.

What AWG cable sizes are compatible?

The termination accommodates cable sizes from #2 AWG through 1250 kcmil.

How to Install 15kV & 28kV Ranger 2 Cable Termination (R2T15/28J)

This guide provides step-by-step instructions for installing the Ranger 2 Silicone Rubber Cable Termination on concentric and jacketed concentric neutral cables for indoor/outdoor applications. Ensure all apparatus are de-energized before beginning.

Estimated time: 1h 30m

Tools needed:

Crimping tool, Measuring tape or ruler, Cable cutting tool, Wire strippers, Gloves

Supplies needed:

Silicone Rubber Termination kit, Lubricant (from kit), Grey Silicone Rubber Tape (from kit), Sealing Mastic (from kit), Connector (optional, if not included), Approved solvent, Aluminum oxide abrasive (grit 120 or finer), Silicone grease, Vinyl tape or binding wire

  1. Ensure Safety and Prepare Cable

    DANGER: De-energize all apparatus before starting installation. Verify that the cable size fits within the kit's range using the Termination Selection Chart. Train the cable into position and cut it to the required length, allowing sufficient neutral wire length for grounding. Prepare the cable using the specified dimensions, accounting for terminal lug depth and additional exposed conductor distance for aluminum lugs.

  2. Apply Mastic and Secure Neutral Wires

    Using 50% stretch, carefully wrap one band of sealing mastic around the cable jacket 1/4 inch (6mm) from the jacket end. Position it precisely as it serves as a marker, then cut it flush without overlapping. Bend the neutral wires back over the mastic and press them into it, securing them to the cable jacket 4-6 inches (100-150mm) from the cut edge using vinyl tape or binding wire. Apply a second mastic band over the neutral wires and the first mastic, again using 50% stretch and cutting flush. Finally, wrap two half-lapped layers of vinyl tape around the mastic seal, maintaining the 1/4 inch (6mm) dimension.

  3. Install Lug or Connector

    If using a lug that will not fit through the termination core, clean the insulation and slide the termination onto the cable before installing the lug (do not remove the core yet). Position the connector or lug and crimp it according to its directions, ensuring not to crimp the last 1/4 to 3/8 inch of the connector. After crimping, remove any excess oxide inhibitor and sharp crimp flashings.

  4. Clean Cable Insulation and Lug Barrel

    Wipe the cable insulation with an approved solvent, taking care not to let the solvent touch the semi-con insulation shield. If abrasive cleaning is necessary, use only aluminum oxide abrasive (grit 120 or finer) on the insulation, not on the semi-con shield. Be careful not to reduce the cable insulation diameter below the kit's allowed range.

  5. Install Termination Body

    Create a track-resistant moisture seal by wrapping a band of gray silicone rubber tape around the base of the terminal lug. If the barrel diameter is smaller than the cable primary insulation, use the tape to build up the band to equal the insulation diameter. Apply a liberal coating of silicone grease to the edge of the semi-con insulation shield to fill the step at the cut-off. For lower terminations with a fold-down skirt, pull the loose end of the removable core through the top until it is flush with the bottom of the termination. Slide the termination body onto the cable, aligning it with the forward edge of the mastic seal. Carefully remove the core by unwinding it counter-clockwise, starting with the loose end. Ensure the termination body, not the core, is butted against the leading edge of the mastic seal and avoid pushing or pulling the assembly during core removal.

  6. Complete Termination Seal and Grounding

    Apply a thin film of silicone lubricant to the skirt and mastic seal area, but do not lubricate the skirt tabs. Carefully fold down the skirt over the mastic seal. Complete the lug area moisture seal using the remaining gray silicone rubber tape, overlapping the termination insulator by approximately 1 inch and extending the tape wrapping over a non-crimped region of the lug/connector barrel with a half-lap configuration. Twist the concentric neutral wires together and connect them to the system ground. Finally, confirm that the High-K step does not exceed 1.5 inches.

Frequently Asked Questions about ABB - Installation Products

How are Thomas and Betts products typically installed?

Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.

What accessories are available for Thomas and Betts products?

Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.

What environmental ratings do Thomas and Betts products have?

Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.

What communication protocols do Thomas and Betts products support?

Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.

What are the key features of Thomas and Betts products?

Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.

What are the main product lines offered by Thomas and Betts?

Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.

What technical support does Thomas and Betts offer?

Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.

What industries and applications are Thomas and Betts products used for?

Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.

What certifications and standards do Thomas and Betts products comply with?

Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.

What are the main product lines offered by Ocal?

Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.