ABB - Installation Products R2IT15M4N0330 - Ranger2 Termination for 15KV indoor application, cable insulation diameter 1.30 -2.10 inches for Cable Type - Tape Shield, Wire Shield, and Unshielded Cable, includes Aluminum 2-Hole Spade connector for #2-1250 kcmil, Stranded or Compressed 500 /Compact or Solid 600

ABB Installation Products R2IT15M4N0330 Ranger2 Termination for 15KV indoor application, cable insulation diameter 1.30 -2.10…

UPC: 783786055265


Documents & Media
Installation InstructionsSpecification SheetManufacturer Product Website

Contact for Pricing

Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.

Overview

The ABB Ranger2 Termination (SKU: R2IT15M4N0330) is designed for 15KV indoor applications, providing reliable cable termination for various cable types. This unit accommodates cable insulation diameters ranging from 1.30 to 2.10 inches, making it suitable for tape shield, wire shield, and unshielded cables. The termination kit includes a robust aluminum 2-hole spade connector, compatible with conductor sizes from #2 AWG up to 1250 kcmil. This connector supports both stranded and compressed conductors up to 500 kcmil, and solid conductors up to 600 kcmil. Engineered by ABB Installation Products, this termination ensures secure and efficient connection for medium-voltage power distribution systems. Key features include: * **Voltage Rating:** 15KV * **Application:** Indoor * **Insulation Diameter Range:** 1.30 - 2.10 inches * **Compatible Cable Types:** Tape Shield, Wire Shield, Unshielded * **Connector Type:** Aluminum 2-Hole Spade * **Connector Conductor Size:** #2 - 1250 kcmil (Stranded/Compressed 500 kcmil, Solid 600 kcmil) This termination solution is essential for maintaining the integrity and safety of electrical infrastructure in industrial and commercial settings.
  • 15KV indoor termination for medium voltage applications
  • Accommodates cable insulation diameters from 1.30 to 2.10 inches
  • Compatible with tape shield, wire shield, and unshielded cables
  • Includes aluminum 2-hole spade connector for #2-1250 kcmil conductors
  • Supports stranded/compressed 500 kcmil and solid 600 kcmil conductors

Specifications

Application
Cable Termination, Indoor Application, 15kV
Cable Type
Copper Tape Shielded Wire
Color
Gray
Conductor Size
500 to 600 kcmil
Connection Type
Aluminum 2-Hole Spade #2-1250 kcmil
Earthing
Products Includes Their Own Grounding System
Mounting
Product Need to have Cable Holder (not included)
Number Of Terminals
(1) Single Phase
Series
Ranger2
Size
1.30 inch - 2.10 inch
Special Features
Silicone Rubber Housing. Lightweight, Compact Design. Pull-Down Tabs for Easy Installation. Thick Wall Construction
Standard
IEEE 48
Type
Cable Termination - Indoor - Ranger2
Voltage Rating
15 kV
Package Dimensions (L x W x H)
0.01 IN x 0.01 IN x 0.01 IN
Package Dimensions (L x W x H)
0.0254 cm x 0.0254 cm x 0.0254 cm
Package Weight (Imperial)
1.0000 L
Package Weight (Metric)
0.4540 kg
Ranger2 Termination. Type - Outdoor, 15kV, Cable Type - Tape Shield/Wire Shield/ Unshield, Insulation Range - 1.30 inch - 2.10 inch, Connector Type - Copper 2-Hole Spade #2-1250 kcmil, Conductor Code - 330 -Stranded or Compressed 500 Compact or Solid 600. Cable Mounting Bracket - B3 - Stainless Steel - Size 1.45 inch - 1.95 inch.

R2T15M4N2330-B3

Ranger2 Termination. Type - Outdoor, 15kV, Cable Type - Tape Shield/Wire Shield/ Unshield, Insulation Range - 1.30 inch - 2.10 inch, Connector Type - Copper 2-Hole Spade #2-1250 kcmil, Conductor Code - 330 -Stranded or Compressed 500 Compact or Solid 600. Cable Mounting Bracket - B3 - Stainless Steel - Size 1.45 inch - 1.95 inch.
Ranger2 Termination for 15KV outdoor application, cable insulation diameter .64 - 1.12 inches for Concentric Neural and Jacketed Concentric Neutral Cable, includes Aluminum 1-Hole Spade connector for #2 to 500 kcmil. #2 Stranded to #1 Solid

R2T15J1-H0220

Ranger2 Termination for 15KV outdoor application, cable insulation diameter .64 - 1.12 inches for Concentric Neural and Jacketed Concentric Neutral Cable, includes Aluminum 1-Hole Spade connector for #2 to 500 kcmil. #2 Stranded to #1 Solid
Ranger2 Termination. Type - Indoor, 15kV, Cable Type - Tape Shield/Wire Shield/ Unshield, Insulation Range - 1.30 inch - 2.10 inch, Connector Type - Aluminum 2-Hole Spade #2-1250 kcmil, Conductor Code - 440 -Stranded or Compressed 1250 Compact or Solid N/A.

R2IT15M4N0440

Ranger2 Termination. Type - Indoor, 15kV, Cable Type - Tape Shield/Wire Shield/ Unshield, Insulation Range - 1.30 inch - 2.10 inch, Connector Type - Aluminum 2-Hole Spade #2-1250 kcmil, Conductor Code - 440 -Stranded or Compressed 1250 Compact or Solid N/A.
Indoor Ranger2 Cable Termination. 15kV, Cable Type - Tape Shield/Wire Shield/UniShield. Insulation Range - 1.30 inch - 2.10 inch. Copper 2-Hole Spade #2-1250 kcmil, Conductor 1250 Stranded/Compressed

R2IT15M4-N2440

Indoor Ranger2 Cable Termination. 15kV, Cable Type - Tape Shield/Wire Shield/UniShield. Insulation Range - 1.30 inch - 2.10 inch. Copper 2-Hole Spade #2-1250 kcmil, Conductor 1250 Stranded/Compressed
Ranger2 Termination for 15KV indoor application, cable insulation diameter 1.30 - 2.10 inches for Cable Type - Tape Shield, Wire Shield, and Unshielded Cable, Copper 2-Hole Spade #2-1250kcmil, Stranded or Compressed 750 /Compact or Solid 900.

R2IT15M4-N2380

Ranger2 Termination for 15KV indoor application, cable insulation diameter 1.30 - 2.10 inches for Cable Type - Tape Shield, Wire Shield, and Unshielded Cable, Copper 2-Hole Spade #2-1250kcmil, Stranded or Compressed 750 /Compact or Solid 900.
Ranger2 Termination for 15KV indoor application, cable insulation diameter 1.30 - 2.10 inches for Cable Type - Tape Shield, Wire Shield, and Unshielded Cable, Aluminum 2-Hole Spade #2-1250kcmil, Stranded or Compressed 1000.

R2IT15M4-N0410

Ranger2 Termination for 15KV indoor application, cable insulation diameter 1.30 - 2.10 inches for Cable Type - Tape Shield, Wire Shield, and Unshielded Cable, Aluminum 2-Hole Spade #2-1250kcmil, Stranded or Compressed 1000.
Ranger2 Termination. Type - Outdoor, 15kV, Cable Type - Concentric Neutral/Jacketed Concentric Neutral, Insulation Range - .64 inch - 1.12 inch, Connector Type - Aluminum 2-Hole Spade #2-1250 kcmil, Conductor Code - 220 -Stranded or Compressed #2 Compact or Solid #1. Cable Mounting Bracket - B1 - Stainless Steel - Size .80 inch - 1.25 inch.

R2T15J1-N0220-B1

Ranger2 Termination. Type - Outdoor, 15kV, Cable Type - Concentric Neutral/Jacketed Concentric Neutral, Insulation Range - .64 inch - 1.12 inch, Connector Type - Aluminum 2-Hole Spade #2-1250 kcmil, Conductor Code - 220 -Stranded or Compressed #2 Compact or Solid #1. Cable Mounting Bracket - B1 - Stainless Steel - Size .80 inch - 1.25 inch.
Ranger2 Termination. Type - Indoor, 15kV, Cable Type - Tape Shield/Wire Shield/ Unshield, Insulation Range - 1.30 inch - 2.10 inch, Connector Type - Aluminum 2-Hole Spade #2-1250 kcmil, Conductor Code - 380 -Stranded or Compressed 750 Compact or Solid 900.

R2IT15M4-N0380

Ranger2 Termination. Type - Indoor, 15kV, Cable Type - Tape Shield/Wire Shield/ Unshield, Insulation Range - 1.30 inch - 2.10 inch, Connector Type - Aluminum 2-Hole Spade #2-1250 kcmil, Conductor Code - 380 -Stranded or Compressed 750 Compact or Solid 900.

Frequently Asked Questions

What is the voltage rating of the R2IT15 termination?

The R2IT15 cable termination has a voltage rating of 15 kV. Its maximum design voltage to ground is 9.5 kV.

What cable sizes are compatible with the R2IT15 termination?

The R2IT15 termination accommodates cables from #2 AWG through 1250 kcmil. It covers insulation diameters from 0.64 in (16 mm) to 2.10 in (53 mm).

What is the operating temperature range for the R2IT15?

The R2IT15 termination operates within an ambient temperature range of -22 to +149 °F (-30 to +65 °C).

What is the operating temperature range for the R2IT15?

The R2IT15 termination operates within an ambient temperature range of -22 to +149 °F (-30 to +65 °C).

What cable sizes are compatible with the R2IT15 termination?

The R2IT15 termination accommodates cables from #2 AWG through 1250 kcmil. It covers insulation diameters from 0.64 in (16 mm) to 2.10 in (53 mm).

What is the voltage rating of the R2IT15 termination?

The R2IT15 cable termination has a voltage rating of 15 kV. Its maximum design voltage to ground is 9.5 kV.

What cable sizes are compatible with the R2IT15 termination?

The R2IT15 termination accommodates cables from #2 AWG through 1250 kcmil. It covers insulation diameters from 0.64 in (16 mm) to 2.10 in (53 mm).

What is the voltage rating of the R2IT15 termination?

The R2IT15 cable termination has a voltage rating of 15 kV. Its maximum design voltage to ground is 9.5 kV.

What is the operating temperature range for the R2IT15?

The R2IT15 termination operates within an ambient temperature range of -22 to +149 °F (-30 to +65 °C).

What is the maximum altitude for R2IT15 installation?

The R2IT15 cable termination can be installed at a maximum altitude of 3300 feet (1005 m).

How to Install the R2IT15M 15kV Ranger 2 Shrink Fit Silicone Rubber Termination for Tape Shielded Cables

This guide provides step-by-step instructions for the indoor installation of the R2IT15M 15kV Ranger 2 Shrink Fit Silicone Rubber Termination on tape shielded cables, covering cable preparation, ground braid installation, and termination placement.

Estimated time: 1h 30m

Tools needed:

Cable preparation tools, Crimping tool, Solvent saturated pads, Aluminum oxide abrasive (grit 120 or finer), Measuring tape or ruler

Supplies needed:

R2IT15M 15kV Ranger 2 Shrink Fit Silicone Rubber Termination Kit (includes termination, preformed ground braid, constant force spring, silicone lubricant, copper foil tape, gloves), Terminal lug or connector, Vinyl electrical tape, Solvent, Oxide inhibitor

  1. Prepare the Cable

    WARNING: All apparatus must be de-energized during installation or removal of parts. This product should be installed only by competent personnel trained in good safety practices involving high voltage electrical equipment. Inspect all parts for damage and compatibility. First, verify the cable size fits within the insulation range specified in the Termination Selection Chart. Train the cable into its final position and cut it to the required length. Prepare the cable according to the dimensions provided in the instructions, ensuring to account for the depth of the terminal lug and any growth allowance for aluminum lugs. To prevent the tape shield from unrolling, secure its edge with a single wrap of the supplied copper foil tape.

  2. Install the Ground Braid

    Carefully wrap one band of vinyl tape around the cable jacket 1/4 inch (6mm) from the jacket end; this serves as a marker. Position the preformed ground braid with its short tail over the tape shield and the solder block centered over the vinyl tape strip. Secure the ground braid to the cable jacket using vinyl tape. Apply a second vinyl tape band directly over the original tape marker and ground braid solder block, maintaining the 1/4 inch (6mm) dimension. Wrap the ground braid around the cable tape shield one complete wrap, trim any excess to prevent overlap, and secure it in place with the constant force spring, wrapping the spring in the same direction as the ground braid. Cinch (tighten) the spring after wrapping the final winding, then secure the spring with two wraps of vinyl tape.

  3. Install the Lug or Connector

    Before proceeding, check to ensure the termination assembly will fit over the selected lug. If the lug will not fit through the termination core, clean the insulation and slide the termination onto the cable before installing the lug, but do not remove the core at this time. Position the connector or lug and crimp it according to the manufacturer’s directions, ensuring not to crimp the last 3/8 to 1/2 inch of the connector. After crimping, remove any excess oxide inhibitor and all sharp crimp flashings or edges.

  4. Clean Cable Insulation and Lug Barrel

    Wipe the cable insulation thoroughly with solvent-saturated pads. Exercise caution to prevent the solvent from touching the semi-conductive insulation shield. If abrasive cleaning is necessary, use it only on the insulation and ensure it is aluminum oxide abrasive, grit 120 or finer. Be careful not to reduce the cable insulation diameter below the specifications allowed by the kit.

  5. Install the Termination

    Apply a liberal coating of silicone grease to the edge of the semi-conductive insulation shield; this silicone will fill the step at the semi-con cut-off. Slide the termination body onto the cable, aligning its edge with the forward edge of the vinyl tape marker. Carefully begin to remove the core by pulling counter-clockwise. Recheck the termination position and continue to remove the core. Do not push or pull on the termination assembly while removing the core. Finally, connect the ground braid to the system ground.

Frequently Asked Questions about ABB - Installation Products

How are Thomas and Betts products typically installed?

Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.

What accessories are available for Thomas and Betts products?

Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.

What environmental ratings do Thomas and Betts products have?

Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.

What communication protocols do Thomas and Betts products support?

Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.

What are the key features of Thomas and Betts products?

Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.

What are the main product lines offered by Thomas and Betts?

Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.

What technical support does Thomas and Betts offer?

Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.

What industries and applications are Thomas and Betts products used for?

Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.

What certifications and standards do Thomas and Betts products comply with?

Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.

What are the main product lines offered by Ocal?

Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.